• Title/Summary/Keyword: fire scene

Search Result 139, Processing Time 0.021 seconds

A Study on the Recognition of Effectiveness and Safety of the Helicopter Aerial Fire Attack (헬기에 의한 산불공중진화 효과 및 안전성 인식 연구)

  • Bae, Taek-Hoon;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.97-104
    • /
    • 2012
  • Forest fires were easy to be larger in Korea. So the utilization of aircrafts, especially helicopters, for forest fire attack would be increased gradually. In the forest fire attack process, the improvement of the helicopter aerial fire attack technique and safety were the chief element for efficient forest fire attack. In this study, we surveyed the recognition of pilots who worked in Forest Aviation Office which was responsible for aerial forest fire attack in Korea. Using these survey results, we suggested more efficient and safer method for aerial fire fighting based on actual experience of air attack at the scene of forest fire burning.

Qualitative Analysis of Ignitable Liquid Residues in Extracts from Fire Debris Samples (유류화재증거물의 정성적 분석 기법 연구)

  • Han, Dong-Hun;Rhee, Sung-Ryong;Kim, Soo-Young
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.14-20
    • /
    • 2011
  • It is very difficult for fire investigators to analyze the fire debris in fire scene to figure out the reason of fire. ASTM E 1618 method with Gas Chromatoghraphy-Mass Spectrometry was used to analyze the ignitable liquid residues in fire debris prepared in our laboratory. According to fire cases, sample handling procedure methods and fire debris store time, different total ion chromatograms were obtained. We wish the study will be helpful to fire investigators to figure out the reason of fire.

The Study on the Countermeasure Plans about Leakage, Explosion and Fire Accidents of Atmospheric Storage Tank (옥외저장탱크 누출, 폭발 및 화재사고 대응방안에 관한 고찰)

  • Lee, Gab-Kyoo
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.48-56
    • /
    • 2016
  • A crude oil leakage from a large atmospheric storage tank occurred on 4 April 2014 at 14:50 in Ulsan City, while storing the crude oil in the tank. Emergency Rescue Control Group was deployed in the scene. The company, Fire Service Headquarters and associated agencies got together in Command Post (CP) for discussing an effective corresponding strategy. Many solution plans were drafted in the debate such as power down, stopping the facilities, checking the density of inflammable gas, suppressing oil evaporation, moving the leaked crude oil to a nearby tank and a processing plant and avoiding marine pollution. All the solutions were carried out in cooperation with several agencies and partners. The oil leakage accident was successfully settled up within the process of responding, The Fire Service Headquarters and the company thought that the most important thing was the suppression of oil evaporation and the elimination of ignition source. With Fire Service Headquarters and several agencies' every effort, an explosion and a fire didn't occurred in the scene. This study suggest the improvement of the operating system in Emergency Rescue Control Group in case of petroleum leakage, explosion and fire accidents of atmospheric storage tank, different from a ordinary disaster. Assuming that petroleum leakage in atmospheric storage tank develop the explosion and fire accidents, the spreading speed of the flame and the burning time was experimented and compared with each other. Furthermore, this study concentrates on the effective field response plan prepared for the afterward explosion and fire accidents from petroleum leak in a storage tank, with the database experimented and analyzed in accordance with the angle of radiation in the foam nozzle and the pressure of pumping in a fire engine.

The study on performance evaluation of heat resistance and smoke control system using air-curtain system in tunnel (터널용 에어커튼 시스템의 내열 및 제연 성능 평가 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Yang-Kyun;Kim, Hwi-Seong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.4
    • /
    • pp.743-755
    • /
    • 2018
  • Tunnel is a semi-closed structure similar to underground space where the smoke generated from fire fills the space fast while escaping from the space slow. Because of such characteristics, when the fire breaks out by traffic accident, the vehicles are jammed making it difficult for the people to evacuate from the scene as well as for the fire engine to gain access to the scene. For such reasons, tunnels are globally categorized into some disaster classes for differentiated facilities and operation approaches. In Korea, less than a 1 km-long tunnel accounts for 80.0% and such a short tunnel which is categorized into Class III is not required to have smoke control system. In this study, a full-scale fire test was conducted in a bid to apply air curtain system using heat-resistant sirocco fan to a less than 1 km-long tunnel. To that end, heat resistance test to verify the normal operation at $250^{\circ}C$ for 60 minutes was conducted. Consequently, despite of rapid rising-temperature and increasing-carbon dioxide inside the air curtain (direction of fire in tunnel), initial condition was found to have been sustained outside the air curtain (opposite direction of fire in tunnel).

Electrical Fire Cause Diagnosis System Using a Knowledge Base

  • Lee, Jong-Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.27-32
    • /
    • 2007
  • For last several decades with the achievement of fast economic development, the electrical fires occupies over 30 percent of total fire incidents almost every year in Korea and not decreased in spite of much times and efforts. Electrical fire cause diagnostics are to confirm a cause for the fire by examination of fire scene. Cause diagnosis methods haven't been systematized yet, because of limits for available information, investigator's biased knowledge, etc. Therefore, in order to assist the investigators and to find out the exact causes of electrical fires, required is research for an electrical fire cause diagnosis system using DB, computer programming and some mathematical tools. The electrical fire cause diagnosis system has two functions of DB and electrical fire cause diagnosis. The cause diagnosis is conducted by a case-based reasoning on a case base and rule-based reasoning on a rule base. For the diagnosis with high reliability, a mixed reasoning approach of a case-based reasoning and fuzzy rule-based reasoning has been adopted. The electrical fire cause diagnosis system proposes the electrical fire causes inferred from the diagnosis processes, and possibility of the causes as well.

A Study on Determination of Fire Origin by Shadow analysis (화염 그림자 분석을 통한 최초 발화지점 확인에 관한 연구)

  • Lee, Seunghun;Choi, Minki;Choi, Donmook
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.165-173
    • /
    • 2014
  • This study is about determination of fire origin by using analysis of shadow that was recorded CCTV data at the fire scene. This analysis is based on straight and radiate nature of light. At fire experiment with about 1m flame, we conformed that 2-dimensional extension line is focused at the bottom of the fire. If the fire is burning at the same level with shadow, it indicate the point of origin exactly. In 3-dimensional analysis that connect extensional line between distinctive points the shadow and the objet, the line focused in the ${\emptyset}$ 50cm-circle. We estimate the reason of that is because of the character of combustion of gases. The line indicate not the point of origin but the flame that is over the point of origin. thus, you have to consider the line indicate the flame when you do 3-dimensional analysis.

The Cause of Fire from Incomplete Electric Contact and Identifying It (불완전 접촉에 의한 발화원인 및 식별방법에 관한 연구)

  • Choi, S.B.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.9-22
    • /
    • 2008
  • We identified objectively the ignition spot of real fire scene and electrical machinery and appliances in sections which were acted for fire cause. By pointing out the actual condition of dealing electronic devices and researching the way of solution, I will presents the fundamental materials which will help to prevent recurrence.

  • PDF

A research of the development plan for a highly adaptable FSR(Fire Safety Robot) in the scene of the fire (화재현장에 적합한 소방방재로봇의 개발 방향 탐색)

  • Kim, Kook-Rae;Kim, Jin-Taek
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.231-237
    • /
    • 2010
  • 소방방재로봇이 2009년 9월부터 대구시 산하 소방서에 배치되어 시범적으로 운용되고 있다. 운용자인 소방관을 대상으로 심층면담과 설문 등을 통해 각종 문제점들과 기능 개선사항을 분석함으로써 현장 적응성, 실효성 있는 로봇의 개발방향을 제시하고자 했다. 소방관 보조로봇은 조종 편의성을 높이고, 장애물 통과 및 이동성이 용이하도록 바퀴 성능을 우선적으로 개선하여야 하며, 소방 필드로봇은 조종 편의성을 높이고, 무게의 경량화와 아울러 제어 통신선 꼬임을 방지하기 위한 무선통신방식을 안정화할 필요가 있는 것으로 분석되었다. 현재 운용중인 로봇에 대한 기능 만족도는 전반적으로 낮으며, 보조로봇에 대해서는 현장 투입의사가 8.4% 수준으로 미미하였다. 이에 소방방재로봇의 조기 상용화를 이루기 위해서는 현장에서의 사용 활성화가 우선되어야 하며 이를 통해 국내 로봇산업의 성장과 경쟁력을 높일 수 있을 것이다.

  • PDF

Integrated Fire Monitoring System Based on Wireless Multi-Hop Sensor Network and Mobile Robot (무선 멀티 홉 센서 네트워크와 이동로봇을 이용한 통합 화재 감시 시스템)

  • Kim, Tae-Hyoung;Seo, Gang-Lae;Lee, Jae-Yeon;Lee, Won-Chang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.2
    • /
    • pp.114-119
    • /
    • 2010
  • Network technology has been developed rapidly for digital service in these days. ZigBee, one of the IEEE 802.15.4 protocols, supporting local communication has become the core technology in the wireless network area. In this paper we designed an integrated fire monitoring system using a mobile robot and the ZigBee sensor nodes which are deployed to monitor fires. When a fire breaks out, the image information of the scene of a fire is transmitted by an autonomous mobile robot and we also monitor the current position of the robot. Furthermore, the data around the place where the fire breaks out and the positions of the sensor nodes can be transmitted to a server via the multi-hop communication in the real time.

Copper Oxide Growing Characteristics of PVC Insulated Wire and Application to the Fire Investigation (비닐절연전선의 산화물 성장 특성과 화재조사에의 적용)

  • Kim, Hyang-Kon;Choi, Chung-Seog;Kim, Dong-Ook;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.37-44
    • /
    • 2007
  • This paper describes characteristics for copper oxide growth of polyvinyl chloride(PVC) insulated wires by series arc. In this experiment, 600V IV wires were used, and characteristics of oxide growth and ignition process were analyzed in case load was 300W, 460W and 600W, respectively. In the result of experiment, covering materials were molten, carbonized and ignited, whereas, oxidized materials were grown in conducting material. During copper oxide was growing, contact voltages and power dissipations increased. When there is copper oxide growth, the waveform of current showed sinusoidal waveform, and the waveform of voltage showed modified waveform. Oxidized materials were heated at about $905^{\circ}C$, surface structure showed irregular shapes, and cross-section showed multiple cracks. And, the results of this experiment were applied to the fire cause analysis of fire evidence collected at the fire scene.