• Title/Summary/Keyword: fire scene

Search Result 139, Processing Time 0.024 seconds

A Study on the Discrimination of Fire Pattern by the Phenomenological Observation (Focused on the Fire Cases) (현상학적 관찰에 의한 연소패턴의 식별에 관한 연구(사례를 중심으로))

  • Choi, Don-Mook;Choi, Sung-Bok;Choi, Jae-Soung
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.98-110
    • /
    • 2009
  • The burned patterns of fire are changed very diversely according to the direction of wind, conditions of combustibles, shape of buildings and so on in the fire scenes. And careful attentions are required on the determining of ignition point and fire causes. In this study, we examined that the burned pattern of fuel controlled fires and ventilation controled fires that impose a heavy burden on fire investigators, carbonized marks of floor, formed by flammable liquids, and combustion marks of falling firing materials through the fire cases. We suggest a proper fire investigation method.

Performance Comparison of Thermal Imagers with Uncooled and Cooled Detectors For Fire Fighting Application (비냉각형 적외선 센서를 이용한 열상시스템과 냉각형 적외선 센서를 이용한 열상시스템의 화재 진압 시 성능 비교)

  • Kim, Byung-Hyuk;Jung, Han;Kim, Young-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.128-132
    • /
    • 2007
  • Thermal Imaging systems are reported to be crucial for fire fighting and beginning to be used by fire fighters. The performance of thermal imaging system is determined by both the radiation of infrared from the target and the attenuation of infrared signal in the optical path by the absorption, scattering, diffraction and reflection. In the scene of fire, water drops with various sizes such as vaporized water, wafer mist from sprinkler, and wafer to suppress the fire reside with various gas generated by burning. To measure the transmission of infrared radiation in the scene of fire, fire simulating system and thermal imagers with cooled detector which detects $3{\sim}5{\mu}m$ infrared and uncooled detector fabricated by the MEMS technology which detects $8{\sim}12{\mu}m$ infrared. are made. With thermal imagers and Ire simulating system, the change of thermal image with respect to the change of visibility controlled with the burned fas was measured. It was found that the transmission of infrared was not reduced by the burned gas, which could be explained by the long wavelength of infrared ray compared with visible ray. However, the transmission of infrared ray was largely reduced by the combination of burned gas and water mist supplied by sprinkler. This is contrary to the results of calculated transmission through the pure water mist and shows that the transmission of infrared ray is mostly affected by the compounds of water mist and burned gas. In this case, it was found that the uncooled detector which detects $8{\sim}12{\mu}m$ infrared ray is better than cooled detector which detects $3{\sim}5{\mu}m$ infrared ray for fire fighting.

A Phenomenological Studies on Ignition Characteristics of Wires by Local Impact, Over Loading and Overcurrent (국부적 충격, 과부하 및 과전류에 의한 전선의 발화특성에 관한 현상학적 연구)

  • Lee, Jeong-Jin;Lee, Chang-Woo;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.53-60
    • /
    • 2010
  • When a fire breaks out, it is difficult to find out the causes of the fire, because combustible things around fire scene are usually burnt away. Among many causes of fires are electronic wires, this thesis deal with the destroyed sheath of electronic wires caused by fire. It was studied with the use of measurement devices focusing on the distinctions of wires and conductors. This study especially emphasized the process of deterioration, burning pattern, and composition of electronic wire conductor. It also has a phenomenological approach to the distinctive cause of fire by some partial force. The fire prevention methods have been suggested through the analysing results of fire patterns. This study is expected to be a useful material for analyzing various electrical fires.

A Study on the Actual Problems of Field Fire Supervision System(Focus to Dajeon City) (상주 소방감리업무의 현실적 문제점에 대한 연구 -대전지역을 중심으로-)

  • Choi, Man-Chul;Kim, Byung-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • In this study, supervision resides fire mission against problems associated with case studies and surveys done through the side of the field work, technical personnel, fire management, including fire code aspects classified into three kinds of items dealt with the issue. Started at the scene of the problem in terms of performance, the issue of the construction process, mainly dealt with the issue at the time of completion. Fire management side, supervisor of technical personnel, human resources management issues, contract issues, fire code level, the frequent revisions of fire regulations, supervision, processing delays of the resulting report, the problem resides with the expansion of Fire Supervision target was mentioned. Finally, the target for each hierarchical supervision, and resident supervisor of the need for supervision of work performance test was carried out by the correlation.

Development of a Classification System for an Electrical Fire Investigation (전기화재 조사를 위한 분류체계 개발)

  • Lee, Jong-Ho;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.53-57
    • /
    • 2005
  • This paper presents development of a classification system for an electrical fire investigation. In order to reduce an electrical fires and establish detailed prevention plans, the collection of an electrical fire causes and base data are very important. Based on this data, a new classification system for an electrical fire investigation was developed and the direction to the classification system was suggested by fundamental analysis. All of the collected information is analyzed by bottom-up method. Criteria items which based on base data were categorized to classify items. The classification of items were found out as follows : basic condition fire scene condition, fire sign, fire cause. Particularly, the fire cause category is classified. A new developed classification system for an electrical fire investigation will be used to analyse electrical fires easily and efficiently.

A study on Fire Hazard of Electric Radiant Heating Systems with Thermal Storage Using Off-peak Electricity (심야용 축열식 전기온풍기의 화재 위험성에 관한 연구)

  • Park, Min-Yeong;Mun, Yong-Su
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.8 no.1
    • /
    • pp.41-48
    • /
    • 2006
  • The purpose of this study is to identify the fire danger of the electric radiant heating system and check the way how to use it and the problems that could be possible through a actual case. We carry out an experiment to identify the possibility of the fire in the similar condition of the actual fire case. The results of this study are as follows. It is a possible condition to fire if the air blast of the electric radiant heating system is blocked by some combustible materials such as plastic bags continuously. A temperature sensor and a residual current device are necessary to disconnect the power source. It is also necessary to attach a notice in front of the electric radiant hearing system that shows users the fire danger to forbid the possible fire. Fires could be happened by internal defects of the electronic products. However, we can also find many external reasons to happen fires. Therefore, we need to check all reasons to make fires in the scene of a fire.

  • PDF

Public Safety & Security Unmanned Aerial Vehicle Heat resistance Environmental Test used in case of Building Fire (건축물 화재발생시 사용되는 재난치안용 무인기의 내열성 환경시험)

  • Kim, Da-Kyung;Bang, Hong-Soon;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.119-120
    • /
    • 2020
  • Recently, a building fire has occurred due to various influences. Accordingly, we are developing an public safety & security unmanned aerial vehicle for fire prevention and initial response to fire. The public safety & security unmanned aerial vehicle is used to grasp the traffic route to enter the fire engine in the event of a fire in a dense structure and to determine the scale of the fire and the area of danger of collapse around the fire site. In this study, an environmental test of the public safety & security unmanned aerial vehicle's heat resistance was performed in an environment simulating a fire scene.

  • PDF

The effects of prehospital care on on-scene time in patients with major trauma (중증외상환자에서 병원전 외상 처치가 현장체류시간에 미치는 영향)

  • Yang, Jin-Cheol;Moon, Jun-Dong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.1
    • /
    • pp.67-76
    • /
    • 2020
  • Purpose: Effective time management, as well as life-saving care, are important in maximizing the prognosis of patients who have sustained major traumas. This study evaluated the appropriateness of emergency medical system (EMS) provider's essential care and how this care impacted on-scene time in patients with major traumas. Methods: This retrospective observational study analyzed the EMS major trauma documents, classified according to the physiological criteria (Glasgow coma scale <14, systolic blood pressure <90mmHg, Respiration rate <10 or >29) in Daejeon, from January, 2015 to December, 2018. Results: Of the 707 major trauma cases, the mean on-scene time was 7.75±4.64 minutes. According to EMS guidelines, essential care accuracy was 67.5% for basic airway, 36.4% for advanced airway, 91.2% for cervical collar, 81.5% for supplemental oxygen, 47.0% for positive pressure ventilation, 19.9% for intravenous access and fluid administration, and 96.0% for external hemorrhage control. Factors affecting on-scene time were positive pressure ventilation (p<.004), and intravenous access and fluid administration (p<.002). Conclusion: Adherence to guidelines was low during advanced airway procedures, positive pressure ventilation, intravenous access, and fluid administration. In addition, the on-scene time was prolonged when the practitioner provided positive pressure ventilation, intravenous access, and fluid administration; however, these durations did not exceed the recommended 10 minutes.

The Behavior Analysis on Arson Crime Scene (방화현장에 대한 행동분석)

  • Lee, Sang-Jun;Kim, Yun-Hee
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.8 no.1
    • /
    • pp.25-39
    • /
    • 2006
  • Recently the arson crime is increased remarkably in comparison with different violent crimes and the pace of increase is very quick. But Social interest about the crime is still slight, it is a fact that the scientific and professional approaches about the crime is insufficient. This problem causes lower arrest rate of the arson crime than the other crime. So, we need to infer the behavior of a arsonist at the crime scene and analyze the profile and psychological state of the suspect from unique point at the crime scene scientifically and professionally. After arresting the arsonist, we interviewed him and compared a product of interview with our analysis previous to arrest.

  • PDF