• Title/Summary/Keyword: fire safety equipment

Search Result 336, Processing Time 0.03 seconds

The Way for improvement of facility to strengthen accessibility of the site for fire department (소방대의 현장접근성 강화를 위한 설비의 개선방안)

  • Oh, Taek-Hum;Sung, Ja-Man;Pak, Chan-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.67-75
    • /
    • 2012
  • Because recently(July 14, 2011) fire occurred in the engine room of a moving taxi under Namsan Tunnel 1, 51 vehicles' driver and more than 250 passengers in the road tunnel were urgently evacuated with abandoned vehicles. Vehicle fires in Namsan Tunnel that day, Sufferers struggled to escape quickly difficult to escape the two-way by abandoned vehicles on the road and to fear many casualties by using vehicle fuel and combustible interior and the driver who is ignorant of vehicle accident continuous entered in the road tunnel had accessibility the site of fire department was more difficult. In this study, It is to investigate structure and basic materials, such as fire extinguish equipment and facilities for damage prevention and to analyze the problems and to plan improvement method of fire extinguish equipment, facilities for damage prevention and transportation facilities(Large traffic signs, Breaker, etc.) on the Namsan Tunnel that in the long-term plan is prepared to strengthen for accessibility of the site of fire department in case of Vehicle's fire.

A Study on the Problem and Improvement of the Fire Detector Test in the Field (화재감지기 현장점검의 문제점 및 개선방안에 관한 연구)

  • Ok, Kyung-Jea;Cha, Ha-Na;Kim, Shi-Kuk;Lee, Chun-Ha
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.180-184
    • /
    • 2008
  • Fire prevention strategies should be aimed at the prevention of structured fire since average annual rates of structured fire have been increased due to economic growth resulted in increasing high rise buildings and multipurpose occupancies over the past ten years. Hence, this study mainly focused on the improve method and problems in the field test of fire detector in compliances with experimental consideration. And it leads us to the flowing conclusions : Firstly, it is necessary to formulate a safety standards on field test. Nowadays, the test enforced in many ways without formulated standard. Therefore it is necessary to be complete the arrangements standardized and how to do the test with formulated safety standards. Second, it is necessary to establish the regal guidance with regard to inspection equipment, ie density, component and temperature of test equipment should be considered. Also the equipment is need to be standardized and improved. Third, fire inspector's competency in their practice should be enhanced. The problems arising from the lack of knowledge and competence regarding inspection could be settled by providing professional education to ensure proficiency in their practice. Specialized training, as has been noted, should be offered in accordance with occupancy type, scale and fire protection system in the fire facilities.

  • PDF

Fire and Evacuation Analysis in Environmental Energy Facilities (환경에너지 시설내 화재 및 피난해석)

  • Jeon, Yong-Han;Kim, Jong-Yoon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.84-90
    • /
    • 2019
  • In this study, a fire and evacuation inside an electronic equipment room in environmental energy facilities were conducted and evaluated using a numerical analysis method. In the fire simulation, the visual distance, temperature distribution, and CO concentration distribution were analyzed using FDS. Based on the results, the Pathfinder program, which is an evacuation simulation, was used to calculate the evacuation time of the occupants and derive an evacuation safety evaluation. As a result, the Available safe Egress time (ASET) of P-01 and P-05 was 203.3 and 398.6 s, respectively. For the Required safety Egress time (RSET) results, all evacuees were evacuated at all points and the safety of the evacuee was secured this simulation showed that the safety evaluation is based on the non - operation of the fire - fighting equipment to improve the safety, making it possible to secure better evacuation safety performance owing to the fire of other fire - fighting facilities.

Analysis of Vehicle Fire Accident Caused by Defect of Optionally Established Equipment (부가적으로 설치된 장치 결함으로 인한 차량화재 사고사례 분석)

  • Park, Nam-Kyu;Kim, Jin-Pyo;Nam, Jung-Woo;Song, Jae-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.40-46
    • /
    • 2014
  • This paper deal with due to the additional equipment established on the vehicle fire accident cases. Recently, vehicle was recognized as other living spaces and it was increasing installation of additional devices such as a black box, multivision, additional battery and so on. However, these additional devices were established on the vehicle by non-specialists such as the general public user or manufacturing and distributors of additional devices since the vehicle factory. Resulting from the additional equipments due to installation errors in these additional equipments connected to the electrical wiring insulation damage or electrical breakdown occurs, and finally leading to a fire caused by the additional equipments. Therefore, additional equipment established on the vehicle due to a fire in order to prevent accidents during the manufacturing process of these devices are installed. If not installed unless the manufacturing process, the installation of additional equipments established by professional who knows the vehicle structure that will be able to prevent the fire.

Case Studies of Firefighter Burns Safety Accident during Fire-fighting Activities (현장 소방활동 중 소방공무원 화상사고 사례 분석 연구)

  • Sin-woong, Choi;So Yun, Lee
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.136-147
    • /
    • 2022
  • The purpose of this study is to analyze four cases of firefighter burns in various fire scenes and to find prevention measures to decrease firefighter injuries. Among the analysis reports prepared by the National Fire Research Institute of Korea from 2016 to 2020, four burn-related accidents are summarized and the main causes are conveyed. The four accidents include second-degree burns from using extinguishers during containment of fires; nine firefighters burned due to re-ignition in the LPG car repair shop; two firefighters injured with third-degree burns from using fire extinguishers during life-saving events in residential housing; and injuries from the radiant heat of the tank BLEVE near the factory fire. These cases are comprehensively investigated in their respective scenes and analyzed based on the fire site investigation reports from the fire department and related theoretical explanations of risk for each accident scene. In the third case study, some experimental research is conducted to evaluate the risk involved with the use of safety gloves. This is evaluated by reviewing Fire Tactics and Standard Operational Procedures (SOP) to determine improvements and recommendations for an efficient firefighting response. Results show that the main causes of burn accidents are the insufficient use of personal protective equipment (PPE), such as safety gloves, and the failure to follow firefighting tactics or SOPs. Through the accident investigation and assessment, it is concluded that to reduce the frequency of burn accidents, the performance of firefighting equipment, SOPs, protection tactics, and safety policy systems require improvement.

A Study on the Effective Method of Fire Safety Management of Geriatric Hospitals (요양병원 소방안전관리의 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.83-88
    • /
    • 2016
  • Currently many geriatric hospitals have been built in Korea because increasing aging rapidly. However the increasing geriatric hospitals make the increasing safety accidents. Therefore this study is conducted by survey and face-to-face talk with the fire safety managers for analyzing safety problem of geriatric hospitals which number is twelve among 15 geriatric hospitals in the north of Chung-buk area. The result of this study is that geriatric hospitals are very old. Fire safety managers holding the fire safety license are a level 2 issued by the Korea Fire Safety Association(KFSA). And the fire safety inspection ability of them is normal (58%). Furthermore a fire safety budget ratio is 83% (A little) in the company yearly budget. And ratio having the fire inspection equipment in the building is 42% (A little) and 33% (Nothing). Satisfaction ratio of their duty is 66% and they also get stress from heavy duty and heavy responsibility. In conclusion, CEO needs to invest and interest the improvement of job performance, satisfaction ratio and fire safety facility. Also government needs the improvement of system to support and supervise the fire safety of geriatric hospitals consistently.

A Study on the Safety Assessment of Water-based Firefighting Training Center using Fire Dynamics Simulation (FDS를 활용한 수소화 훈련장 안전성 평가에 관한 연구)

  • Doyoeng Park;Junho Kim
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.4
    • /
    • pp.317-323
    • /
    • 2024
  • According to the section A-VI/3 of the International Convention on Standards of Training, Certification and Watchkeeping for Seafarers (STCW), Water-based firefighting training center is mandatory to obtain onboard certificates. This space, being similar to fire situations on ships requires that safety measures be quantified to ensure occupant safety and establish operational standards. For fire safety evaluation, cases were designed based on the presence or absence of smoke control equipment using Pyrosim based on Fire Dynamics Simulation (FDS). Vector analysis was performed to evaluate flow of smoke and heat. Available safe escape time / required safe escpae time (ASET/RSET) analysis was conducted to evaluate safety by comparing the interpreted numerical results through Pathfinder. During safety evaluation of the current operational condition, the appropriateness of the function of each smoke control equipment was numerically and visually indicated. The emergency situation with dust collector stopped was expressed by each evacuation time and safety margin of 111.2 seconds, suggesting that be used as a standard of evacuation time.

Performance Assessment Model for Fire Safety Protection of Office Building (사무소 건축물의 화재안전 성능 평가모델)

  • Yang, Eun-Bum;Hwang, Young-Sam;Lee, Chan-Sik
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.69-74
    • /
    • 2004
  • This study is to suggest a performance assessment model for fire safety protection of office building 34 asessment elements were chosen by interviewing with experts, reviewing several codes and existing relevant models, assessment elements included in this model are comprised of five categories which are 'performace of protected area', 'performance of fire partition', 'safety performance of fire escape', 'performace of smoke control system' and 'performace of fire fighting equipment'. The weight of each element was computed by systematic approach like an AHP (analytical hierarchy process), which was conducted by experts who work in the field of fire protection. This model would be utilized as a part of assessment model for the overall performace of domestic office building.

The Characteristics of the Fatal Accidents Caused by Fire, Explosion and Asphyxiation during Welding and Flame Cutting in the Manufacturing Industry (제조업에서의 용접·용단 작업 중 화재·폭발·질식 사망사고 특성)

  • Seo, Dong-Hyun;Han, Ou-Sup;Lee, Keun-Won
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.21-27
    • /
    • 2019
  • Many accidents have been occurring during welding and flame cutting work related to maintenance and repair as the domestic manufacturing facilities gradually become decrepit. However, it is not easy to find the accurate statistics and analysis data on accidents occurring during welding or flame cutting operations related to maintenance and repair of machinery and equipment. Therefore, in this study, the fatal accident cases of fire/explosion and asphyxiation that occurred during the welding and flame cutting work in the manufacturing industry were collected and their characteristics were analyzed. Then, we tried to find the connection of the accidents according to the machinery/equipment and the work content, and to provide the materials and measures that can be used to prevent the similar accidents. We collected 329 cases of the fatal accidents related to fire/explosion and leakage/contact of chemical substances in the domestic manufacturing industry during the last 10 years (2008 ~ 2017). Among them, 72 accidents occurred during welding or flame cutting were extracted and the related reports were investigated whether they occurred during usual work or unusual work. Also, the machinery/equipment and the work content related to the accidents were classified and analyzed based on the criteria. The analysis results showed that 31 cases of the fire/explosion accidents occurred during usual work and 32 cases during unusual work, and it was found that 9 cases of asphyxiation death occurred during usual work. Then, from the analysis results, the connections of the machinery/equipment and the work contents related to the accidents were schematized into a accident tree.