• Title/Summary/Keyword: fire safety equipment

Search Result 336, Processing Time 0.028 seconds

A Study on the Current State and Improvement of Operation of Fire Investigation Teams (화재조사 실태 분석과 개선방안에 관한 연구)

  • Lee, Tae-Geun;Chae, Jong-Min
    • Journal of forensic and investigative science
    • /
    • v.1 no.1
    • /
    • pp.45-53
    • /
    • 2006
  • The purposes of fire investigation are to identify and analyze the causes of fire and, using the results in promoting fire fighting policies, ultimately to prevent fires caused by similar causes and to protect people's life and properties from fire. However, although the patterns of fire are getting more diverse and complicated with the rapid development of industry, complicated with the rapid development of industry, fire fighting organizations are continuing traditional superficial fire investigation without operating a fire investigation department for the reason of insufficient manpower, equipment and budget, losing public confidence. Thus, the present study purposed to propose plans to improve the technicality of fire investigation and win public confidence in fire investigation. First, the technicality of fire investigation should be improved by operating a department and personnel exclusively for fire investigation. Second, fire investigation should be more scientific and precise using high tech fire investigation equipment. Lastly, responsible fire fighting administration should be realized through statistical analysis of the causes of fire and computerization. The results of this study are expected to contribute to the safety and security of our society.

  • PDF

A Study of Classification of Road Tunnel for Fire Safety (안전성 향상을 위한 도로터널 등급에 관한 연구)

  • Yoo, Ji-Oh;Rie, Dong-Ho;Shin, Hyun-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.112-119
    • /
    • 2005
  • In road tunnel, in order to prevents an accident and minimize the damage of an accident in the case of fire, safety facilities and equipments are integral parts. The type and amount of safety facilities are based on tunnel type and length, traffic flow rate, etc. Therefore many countries use a tunnel classification system that categories tunnel into groups, and specifies the necessary emergency equipment for each group. In this study, for the purpose of classifying tunnel based on tunnel ist investigated the domestic and foreign standards and regulations for safety of road tunnel. As a results, we suggest the method of classification of tunnel by traffic performance, tunnel grade, the volume of traffic, fraction of HGV, rules or regulations for transports of dangerous good through tunnel.

Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Bookstore - (건축물의 적재가연물 특성에 관한 연구 -대형서점의 적재가연물 연소발열성상-)

  • Nam, Dong-Gun;Yuji, Hasemi;Jung, Jong-Jin;Lim, Woo-Sub;SaKong, Seong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.3-6
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in bookstore. In this report, burning behavior of typical combustible objects in bookstore are studied by measuring heat release rates of bookshelf with book.

  • PDF

A Study on Authoritativeness of Electric Fire by Activating of Fire Damaged MCCB (소손된 배선용 차단기 동작상태에 의한 전기화재 규명의 신뢰성에 관한 연구)

  • Lee, Jong-Hwa;Mun, Yong-Soo;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • In the fire there are fusion signs and damage by fire, and insulation aging and carbonization of the electric wiring in the ignition spot because of special characteristic of the appliance in the electricity fire. Because of the physical factor applied in the damage of fire, the decision of ignition spot by eye investigation is insufficient. In this paper, the cause of electricity fire is researched. The focus is on the operation state of operated MCCB(Molded Case Circuit Breaker) at the time of electricity fire. Through grasping the operation principle of MCCB and the experiment, the state of MCCB after fire suppression is discriminated. The distinction possibility on the exist of electricity fire is proposed.

The fire resistance performance test methods and equipment overview on the marine plant (해양플랜트 기자재의 화재저항 성능에 관한 시험방법 및 설비의 개요)

  • Jeon, Jun-Pyo;Kim, Jung-Sik;Choi, Tai-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.113-116
    • /
    • 2012
  • 플랜트란 산업 기계, 전기 통신 기계등 여러 가지를 생산하는 공장을 의미하고 있다. 해양플랜트는 바다위에 설치된 시설이라고 볼 수 있으며 주로 원유 및 가스를 채취하여 시중에서 사용할 수 있도록 정유공정까지 거치는 대규모 설비라고 할 수 있다. 따라서 가연성 물질을 생산, 적재함으로 화재 및 폭발의 위험성이 상존하며 화재가 발생하면 인화성 물질로 인한 대규모 화재와 폭발로 인하여 인명과 재산피해의 규모 또한 가름하기가 어렵다. 본 논문에서는 해양플랜트 화재시 화재와 폭발 두 가지 위험성 중 제트화재에 저항을 가지는 기자재를 평가할 수 있는 ISO 22899-1 시험방법과 설비에 대하여 설명하고자 한다.

  • PDF

A Study on Clean Agent Fire Extinguishing Ability Using Nitrogen and Novec Mixtures Gas (질소와 노벡 혼합가스를 이용한 청정소화약제의 소화성능에 관한 연구)

  • Lim, Woo-Sub;Jung, Jong-Jin;Nam, Dong-gun;SaKong, Seong-Ho;Kim, Jong-Won;Choi, Kenu-Joo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.76-83
    • /
    • 2008
  • In the course of increasing in human and material damage caused by fire, it is an important research field to develop clean extinguishing agent which does no harm to global environment as well as has a good extinguishing efficiency. This research is a basic step to develop a new clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using nitrogen and Novec mixtures gas which are inert gas and new clean extinguishing agent. We used Cup Burner Test made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test, and the fuels used in the test are n-heptane, methanol, ethanol, iso-propanol and 1-butanol. The experimental results of flame extinguishing concentration are n-heptane 6.54%, methanol 8.47%, ethanol 6.98%, isopropanol 6.10% and butanol 6.54% by pure Novec agent. So the finding is that a new clean agent, Novec has an efficient extinguishing ability in a state of gas. Also, in a test as to mixtures gas of nitrogen and Novec, it has a good result for minimum oxygen concentration is under 16%.

A Study on Risk Evaluation and Classification of Fire Equipments for Certification (소방용품의 강제인증을 위한 위험도평가 및 품목분류에 관한 연구)

  • Choi, Gi-Heung
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.7-12
    • /
    • 2009
  • This study focuses on the classification of fire equipments for certification based on the risk evaluation. In general, known statistics on fire equipment-related accidents needs to be used for risk evaluation. When statistics is not available, however, expected frequency and severity of accident for individual equipment can be taken into account in evaluating the related risks. Based on the level of inherent risks, each equipment is then classified into three categories for certification. For equipments that risk evaluation is not possible, characteristics of those products such as reliability are considered for classification. Once classified, each equipment is assigned an appropriate certification module.

Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor Factory (반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계)

  • Han, Su-Jin;Kang, Kyung-Sik
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.11a
    • /
    • pp.325-336
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room (FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design (PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

  • PDF

Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor factory(1) (반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계(1))

  • Han, Su-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.5
    • /
    • pp.211-229
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room(FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design(PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

Detection of Current Signal and Thermal Characteristics of Electric Fan Operated in Various Situations (선풍기의 운전 상황별 발열특성 및 전류신호 검출)

  • Kim, Doo-Hyun;Lee, Heung-Su
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.20-27
    • /
    • 2014
  • Cooling equipment is the frequent occurrence of fire despite the absence of the heating element. National fire statistics in 2013 show that a total of 263 fires occurred in the cooling equipment and the number of electric fan has 145 fire cases. This is accounted for 55.1% of the whole. Electric fan is the electrical appliance that the heat is generated on the winding wire and the iron core. If such characteristic is not controled properly, fire would break out at the electric fan. also there is a gap filled with an insulator between connection terminals of the capacitor in the electric fan. But in case that the gap on the capacitor is covered with some conductive material such as dust, there would be a fire as well caused by electrical heating locally. Although many studies related with those have been conducted, electric fan fire is continuously occurred. In this study, thermal characteristics and current signal in various conditions such as the heat generation of windings including iron cores of the motor and the dielectric breakdown of terminals on the capacitor connected to the motor were detected. In order to measure the maximum temperature, "third level" wind velocity button was pushed and the time selection switch to "continuation" was set. Analyzed data would be available for the fire safety of the electric fan.