• 제목/요약/키워드: fire risk reduction

검색결과 62건 처리시간 0.034초

공장건물의 화재리스크 경감방안에 관한 연구 (A Study on Factory Building Fire Risk Reduction Management)

  • 정의수;강경식
    • 대한안전경영과학회지
    • /
    • 제10권3호
    • /
    • pp.43-53
    • /
    • 2008
  • This study is carried out for the fire safety of the factory building, the fire risk reduction measure in compliance with an example approached in fire risk reduction systematically, contribute to reduce the fire risk. The analytical fire risk process of discovering, identifying, estimating and evaluating risk and control measure as risk reduction measures are core concept, applies loss prevention with loss control techniques. The painting process in the workplace where the fire hazard and death accident accompanies coexists. Loss prevention problem of creation prevention of dangerous atmosphere at workplace is health and human services problem of normal circumstances, must be inspected with problem of combustible gases at the time of fire explosion. Static electricity measure accomplished the risk control process thoroughly as the fire risk reduction process model with the ignition sources measure which is presented. Fire risk from within organizing will be able to classify with each field by detailedly but risk treatment process will be able to apply basically all the same concept. Consequently about risk management example from before, this study is proposed risk management techniques that standardized rightly in the actual condition of organization with one plan, with discovery of fire risk, the feedback process in compliance with a fire risk reduction and the review which control the result is joint responsibility of engineer, technical expert and manager as part of safety management to practice with the fact must be supervised.

위험 인식이 위험성 수용 기준 설정에 미치는 역할 (The role of risk perception for the definition of acceptable risk)

  • 노삼규
    • 한국화재소방학회논문지
    • /
    • 제9권2호
    • /
    • pp.3-9
    • /
    • 1995
  • Acceptable risk problem are decision problems they requires a choice among different estimations of technological risks. The alternative option includes a threat to life among its consequences. However, the definition used to ignore the public's perceived risk which should be identified as acceptable risk. The study examine the role of perception of risk as acceptable risk between different situations of estimated consequence and probability of risk. The cost benefit principle for the reduction of risk applied to find the possible solutions with in decision making process.

  • PDF

토지이용의 위험성 제어계획 -사용 밀도에 따른 기준치 설정의 접근방법- (Planning Controls for Land Use Safety)

  • 노삼규
    • 한국화재소방학회논문지
    • /
    • 제10권2호
    • /
    • pp.20-27
    • /
    • 1996
  • This paper discussed the limit of existing safety controls where the use of land around hazardous industry. There is a gap between engineering evaluation of acceptable criteria for loss reduction and risk exposure to the areas of high risk outside plants from the aspects of risk perception. The paper performed how land use safety could be designed between the density of uses with the duration of risk exposure by type of land use. It concluded the needs of multi-dimensional presentation for an appropriate risk controls on existing and future land use safety.

  • PDF

기능적 안전을 고려한 FSA기반 기관 구역 화재 안전성 평가 및 개선 (Fire Safety Assessment Based on FSA and Risk Reduction of Machinery System Considering Functional Safety)

  • 서성원;양영순;정소연;유원선
    • 대한조선학회논문집
    • /
    • 제49권3호
    • /
    • pp.239-246
    • /
    • 2012
  • It is the well-known fact that most part of goods transported are moved on the unfavorable ocean and even a small amount of accident on sea is extremely dangerous for human lives, financial losses, and social responsibility. Among the several causes of accidents, those by fire have occurred frequently and their damage has been highly serious. The aim of this paper is to assess the risk of fires due to oil leakage in the machinery space. To define the possible fire scenario, our team has performed the search of casualty database and reviewed the previous and various studies in the field. As a result, it is noted that the quantitative risk of the fire scenario have been evaluated on the ground of the FSA risk model. The expected frequency of a fire amounts to incidents during the life of a ship, and the expected financial damage amounts to 5,654 USD per a ship. By adopting Safety Instrumented System (SIS) introduced in IEC 61508 and IEC 61511, SIS model is designed to prevent oil leakage fire as a risk reduction method. It is concluded that System Integrity Level (SIL) 1 seems to be appropriate level of SIS.

건축물 지진화재위험도 평가기법의 국산화 전략 (Localization Strategy of Building Fire Following Earthquake Risk Assessment Method)

  • 강태욱;김수빈;김예은;강재도;김혜원;신지욱
    • 한국공간구조학회논문집
    • /
    • 제23권3호
    • /
    • pp.57-69
    • /
    • 2023
  • In this study, in order to establish a strategy for developing an fire following earthquake risk assessment method that can utilize domestic public databases(building datas, etc.), the method of calculating the ignition and fire-spread among the fire following earthquake risk assessment methodologies proposed by past researchers is investigated After investigating and analyzing the methodology used in the HAZUS-MH earthquake model in the United States and the fire following earthquake risk assessment methodology in Japan, based on this, a database such as a domestic building data utilized to an fire following earthquake risk assessment method suitable for domestic circumstances (planned) was suggested.

철도터널 화재 시 피난개시시간지연 및 화재성장곡선이 정량적 위험도에 미치는 영향 (Effects of evacuation delay time and fire growth curve on quantitative risk for railway tunnel fire)

  • 유지오;김효규;이후영
    • 한국터널지하공간학회 논문집
    • /
    • 제20권5호
    • /
    • pp.809-822
    • /
    • 2018
  • 철도터널의 방재시설 설계 시 성능위주설계의 일환으로 화재위험을 정량적으로 평가하는 정량적 위험도평가기법이 도입되어 적용되고 있다. 그러나 각종 위험인자가 위험도에 미치는 영향을 검토하기 위한 연구는 부족한 실정이다. 이에 본 연구에서는 피난개시 시간지연(210~873초) 및 화재성장곡선(1량 화재, 1량 화재지속, 화재중첩)이 정량적 위험도 평가에 미치는 영향을 검토하기 위해서 모델터널(연장: 15 km, 경사도 1.5%, 단면적 $57m^2$, 단굴 양방향 터널)을 대상으로 위험도 평가를 수행하였으며, 다음과 같은 결과를 얻었다. 시나리오(270개)에 대한 분석결과, 사망자는 주로 화재연기의 이동방향과 동일한 방향으로 대피하는 경우가 발생하고 있으며, FED가 0.3을 초과한 후에는 최대 10분 이내에 최대인원이 사망하는 것으로 나타났다. 위험도가 비교적 낮은 범위에서는 피난연결통로간격 및 피난개시시간, 화재성장곡선이 위험도에 영향을 미치는 것으로 나타나고 있으나, 위험도가 한계치에 도달하는 조건에서는 이들의 영향이 거의 없는 것으로 나타났다. 특히 본 연구에서는 피난연결통로의 간격이 1,500 m 이상인 경우에는 피난개시시간지연의 축소나 화재강도 및 화재지속시간의 감소효과가 거의 나타나지 않는 것으로 평가되었다.

How to Reduce Fire Fatalities in Residential Occupancies on the Way to a Rapidly Aging Society?

  • Sekizawa, Ai
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2006년도 춘계학술논문발표회 논문집
    • /
    • pp.29-40
    • /
    • 2006
  • Everybody may be vulnerable to fires depending on the time, place, and circumstances. Fire statistics show that the occurrence of fire death depends not only on the severity of a fire itself, but also largely on the conditions of occupants such as physical functions, the environment around occupants, and the type of facility where are fire occurs. The review of fire safety from the viewpoint of vulnerable populations does not simply mean additional special attention and care only to high risk groups, but instead it means significant review of fire safety design and systems for all people from a more universal standpoint. Therefore, in order to examine the strategies of a fire death-reduction program, safety measures suitable for the relevant high-risk groups considering the type of vulnerable person, the type of fire, and the type of building in residential occupancies. Solutions will require strenuous multilateral effort and flexibility.

  • PDF

조선시대 전통건축에서의 화방벽(火防壁) 사용에 대한 연구 (A Study on the Usage of Hwabangbyeok wall in Traditional Architecture in Joeson Dynasty)

  • 조상순
    • 건축역사연구
    • /
    • 제29권3호
    • /
    • pp.7-14
    • /
    • 2020
  • It can be meaningful that this study attempted to analyze the use cases and forms based on the literature on the painting walls of the J oseon Dynasty, and attempted basic research to prevent disaster damage using traditional elements. This study summarizes the use of the Hwabangbyeok wall of J oseon Dynasty as follows. First, Hwabangbyeok wall was used from the early J oseon Dynasty and was adopted by palaces and other major state facilities to cope with fire and theft. Second, the Hwabangbyeok Wall was also referred to as the wall below the lower part of the wall, and was constructed with the purpose of preventing disasters from outside. Third, in an analysis of the Daeseongjeon shrine of Hyanggyo, many construction cases were identified mainly in the Gyeonggi area, which is assumed to be based on production and construction conditions along with local climatic factors. Fourth, it can be said that the Hwabangbyeok wall was basically adopted to prevent comprehensive disaster risk reduction in case of external intrusion and fire.

터널 방재설비의 합리적 설치를 위한 분석적 연구 (An analysis study for reasonable installation of tunnel fire safety facility)

  • 박진욱;유용호;박병직
    • 한국터널지하공간학회 논문집
    • /
    • 제17권3호
    • /
    • pp.243-248
    • /
    • 2015
  • 최근 국내에서는 도로 및 철도 터널의 건설이 꾸준히 증가하고 있으며, 교통체증 해소 및 도시계획 그리고 개량공사 등에 따라 터널이 더 깊은 지하에 위치하거나 장대화되고 있는 추세이다. 이러한 경우 터널 내부사고 중 인명피해에 가장 큰 위험요소인 화재사고가 발생할 경우 대형사고로 이어질 확률이 굉장히 높아진다. 본 연구에서는 정량적 위험도 분석 기법인 QRA(Quantitative Risk Analysis)를 터널에서의 방재설계에 적용하고자 국내 QRA 사례분석을 수행하고, QRA 기법의 적용 유무에 따른 비용 산출을 비교하였다. 그리고 AHP(Analytic Hierachy Process)기법을 사용하여 터널 방재시설의 위험도 저감 효과를 분석하여 터널 화재시 위험도를 낮출 수 있는 중요 인자들에 대한 우선순위를 제시 하였다. 그 결과로부터 QRA가 적용된 사례에서 상당한 비용절감 효과가 나타났으며, 그로 인해 합리적인 방재시설의 설계가 가능할 것으로 판단하였다. 그리고 방재시설별 비용대비 위험도 저감효과를 통한 방재시설 우선순위는 송수관설비, 비상조명, 대피통로, 제연설비의 순으로 분석되었다.