• 제목/요약/키워드: fire risk assessment

검색결과 352건 처리시간 0.025초

119 구급대원 구급활동의 근골격계 증상 및 위험실태 (A Survey of Musculoskeletal Symptoms & Risk Factors for the 119 Emergency Medical Services (EMS) Activities)

  • 김대성;문명국;김규상
    • 대한인간공학회지
    • /
    • 제29권2호
    • /
    • pp.211-216
    • /
    • 2010
  • Fire service personnel and ambulance paramedics suffer musculoskeletal disorders as they lift and carry patients while performing Emergency Medical Services (EMS). The objective of the current study was performed to examine the association between working environment and musculoskeletal disorders of 119 paramedics and to analysis the EMS activities for them through basic survey (including task characteristics, risk factors, symptoms and illnesses). Observational job analysis of EMS activities indicated the squatting posture during first-aid performed on floor and the abrupt use of force during carrying heavy load including stretcher with patients on as hazard factors, and excessive low back twisting and bending during stairway transfer was observed. In addition, work-physiological assessment revealed various but rather high lumbar muscle usage rate among the study subjects, being 14.6~32.8% compared with Maximum Voluntary Contraction (MVC) during patients transfer work. Resting heart rate showed 65/min, on the other hand, heart rate on mobilization indicated maximum 124~156/min. Therefore, the results of analysis to the EMS activities, rescuer activities and medical tasks were accompanied with high possibility of accident and musculoskeletal disorders. Also, EMS activities indicated high muscle fatigue and energy consumption, and accumulated muscle fatigue with during continued work.

중·소 화학공장에 적합한 위험성 평가 기법 개발에 관한 연구 (A Study on Hazard Identification Method for Small and Medium Chemical Industries)

  • 이재민;유진환;고재욱
    • Korean Chemical Engineering Research
    • /
    • 제45권1호
    • /
    • pp.103-108
    • /
    • 2007
  • HAZOP 기법은 전문가의 경험과 지식을 기초로 브레인스토밍(brainstorming) 방식을 적용함으로써 체계적으로 잠재 위험을 분석, 평가하는 방법으로 검토 시 누락의 가능성을 배제하고 비교적 객관화된 평가서를 작성할 수 있는 장점으로 인하여 널리 이용되고 있다. 그러나 대규모 화학공장에서는 HAZOP 기법을 이용한 위험성 평가의 실시 및 그 결과의 활용이 잘 이루어지고 있으나, 중 소 화학공장들의 경우 기법 적용이 용이하지 못하여 현실적으로 많은 어려움을 겪고 있다. 이에 본 연구에서는 기존에 많이 사용되고 있는 위험성 평가 기법들의 장 단점을 분석 검토하여 중 소 화학공장의 현장에 적용하기 쉬운 위험성 평가 기법을 제시함으로써 사업장 위험 관리 수준의 향상에 기여하고자 하였다.

수소 압축 개질공정의 정성적 위험성 평가 (Qualitative Risk Assessment of Hydrogen Compression Reforming Process)

  • 신단비;서두현;김태훈;이광원;이동민;김현기;홍성철
    • 한국수소및신에너지학회논문집
    • /
    • 제33권1호
    • /
    • pp.61-66
    • /
    • 2022
  • In order to introduce the hydrogen economy and increase supply, research in the field of hydrogen production is being actively conducted. Among the hydrogen production methods, the method of steam reforming from natural gas and producing it currently accounts for about 50% of the global hydrogen production. In the method of steam reforming process, hydrogen can be produced by adding a reformer to an existing natural gas supply pipe. Because of these advantages, it is evaluated as a realistic production method at present in Korea, where the city gas supply chain is well established. But there is concern in that it is highly likely to be installed in downtown areas and residential spaces. In this study, the risk of the process of steam reforming to produce hydrogen was reviewed.

Task-specific Noise Exposure Assessment of Firefighters

  • Kang, Taesun
    • 한국환경보건학회지
    • /
    • 제45권6호
    • /
    • pp.569-576
    • /
    • 2019
  • Objectives: The main purpose of this study was to assess firefighters' daily personal noise exposure and explore noise levels related to specific tasks and their contributions to total noise exposure using 24-hour full-shift noise exposure measurements with task-based data. Methods: Noise exposure was assessed for eight firefighters (two rescuers, two drivers, and four suppressors) using time-activity diaries. We collected a total of 24 full-shift personal noise sample sets (three samples per a firefighter). The 24-hour shift-adjusted daily personal noise exposure level (Lep,d), eight weekly personal noise exposures (Leq,w), and 40 task-specific Leq values (Leq activity) were calculated via the ISO/NIOSH method. Results: The firefighter noise-sample datasets showed that most firefighters are exposed to noise levels above EU recommended levels at a low-action value. The highest noise exposure was for rescuers, followed by drivers and suppressors. Noise measurements with time-at-task information revealed that 82.3% of noise exposure occurred when checking equipment and responding to fire or emergency calls. Conclusions: The results indicate that firefighters are at risk of noise-induced hearing loss. Therefore, efforts at noise-control are necessary for their protection. This task-specific noise exposure assessment also shows that protective measures should be focused on certain tasks, such as checking and testing equipment.

실습선 재난 시 피난 시나리오 별 위험구역 평가 (Evaluation of Hazardous Zones by Evacuation Scenario under Disasters on Training Ships)

  • 임상진;이윤호
    • 해양환경안전학회지
    • /
    • 제30권2호
    • /
    • pp.200-208
    • /
    • 2024
  • 승선 인원이 많은 실습선은 화재가 발생하는 경우 대형 인명피해로 확장될 수 있으며 이에 따라 선원법 및 Safety Life At Sea(SOLAS)에서는 퇴선 훈련에 대한 중요성을 강조해 왔다. 따라서 본 연구에서는 승선 인원이 많은 국립목포해양대학교의 세계로호를 대상선박으로 선정하여 preliminary hazard analysis(PHA) 정성적 위험성 평가 기법을 통해 각 deck의 화재 사고 위험빈도와 심각성에 대하여 예측하였다. 또한 위험성이 높은 구역에서의 화재를 가정 한 뒤, 그 위험성을 정량적으로 예측하기 위하여 대피 시간 및 인구 밀도에 대한 시뮬레이션을 수행하였다. 그 결과, 총 대피시간이 인구 분포가 한 구역에 집중되어 있던 식사 시간을 가정한 시나리오에서 501초로 가장 길게 예측되었으며 시나리오에 따라 일부 deck에서 1.4pers/m2 이상의 상대적으로 높은 인구밀도를 나타내며 대피 인원이 정체되는 현상을 보였다. 본 연구 결과는 다양한 피난 시나리오에 따른 대피시간 및 인구밀도를 정량화하여 실습선의 상황에 맞는 훈련 시나리오를 개발하기 위한 기초자료로서 사용될 것으로 보이며 추후 수학적 모델과 실험값의 비교를 통하여 연구를 확장할 수 있을 것으로 예상된다.

인적오류 저감을 위한 인간 신뢰도 분석 체계 및 평가에 관한 연구 (Development and Evaluation of Human Reliability Analysis Model for the Reduction of Human Errors)

  • 정경희;변승남;조재립
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.2048-2051
    • /
    • 2010
  • Almost all companies have paid much attention to the safety management ranging from maintenance to operation even at the stage of designing in order to prevent accidents, but fatal accidents continue to increase throughout the world. In particular, it is essential to systematically prevent such fatal accidents as fire, explosion or leakage of toxic gas at factories in order to not only protect the workers and neighbors but also prevent economic losses and environmental pollution. In addition, HRA may be used to detect the human errors which may cause accidents or trace back to any mistake on the part of workers. Usually, HRA technique is used in association with other risk assessment techniques. Moreover, it can serve to enumerate the human errors which may occur during operation or down-time or correct the existing system to reduce the mistakes. This work focuses on the coincidence of human error and mechanical failure for management of human error, and on some important performance shaping factors to propose a method for improving safety effectively of the process industries.

  • PDF

Characteristics of a Corona between a Wiring Clamp (Dead End Clamp) and a Porcelain Insulator Used in a 154kV Power Receptacle

  • Han, Woon-Ki
    • International Journal of Safety
    • /
    • 제7권1호
    • /
    • pp.21-25
    • /
    • 2008
  • The occurrence of a corona is that electrical discharge due to the heterogeneity that occurs when an electrical field is concentrated in an electrode due to a cusp formed on said electrode. Wire treatment at the end of a 154kV dead end clamp for end users accelerates the occurrence of corona, which in turn leads to power loss and noise. In this study, the characteristics of the corona which occurs between porcelain insulators and support clamps of overhead lines used in l54kV power receiving facilities for end users were investigated. The corona, which cannot be identified by one common method, was measured utilizing a UV image camera. A risk assessment for fire damage and its status was suggested. The stress distribution of the electrical field by length of bare wire was suggested by means of the finite element method (FEMLAB). As a result, it was found to affect a porcelain insulators. These results can be utilized for the enhancement of clamp installation and safety in power facilities.

교육시설 재난사고 실태 분석에 따른 재난안전 평가 방향에 관한 연구 (A Study on the Disaster Safety Assessment on the Analysis of Educational Facilities due to Disasters)

  • 허병이;김성중
    • 교육녹색환경연구
    • /
    • 제11권3호
    • /
    • pp.25-35
    • /
    • 2012
  • Even though newly formed schools do struggle to strengthen their security in safety, existed schools have limitations for active response against natural disaster. From analyzing the results of accident cases and states in misfortune and the safety supervision of school facilities, it is said that damages by wind, flood and fire are typical types of disaster accidents. Also, according to the basic law of misfortune and the safety supervision, it emphasizes education, training, and actions that prevent from being a victim of natural disaster. In terms of these finding, establishing disaster safety organization, control system and having students an opportunity to learn how to response against disaster should be critical component in managing disaster safety of school facilities.

소규모 건설현장에서 위험유발요인과 안전점검이 재해 저감 대책에 미치는 인과 관계 (Causal Relationship between the Risk-inducing Factors and Safety Inspection and Accident Reduction in Small Construction Sites)

  • 문필재;공하성
    • 문화기술의 융합
    • /
    • 제6권2호
    • /
    • pp.55-70
    • /
    • 2020
  • 이 연구는 소규모 건설현장 구조물 공사 참여 근로자들을 대상으로 위험유발요인과 안전점검이 재해 저감 대책에 미치는 영향을 밝히고자 하였으며, 연구결과는 다음과 같다. 첫째, 위험유발요인이 인적요인에 미치는 영향에서 작업준비와 거푸집 해체, 그리고 조치 여부, 기록유지가 통계적으로 유의미한 영향을 미쳤다. 이는 안전점검은 위험유발요인이 인적요인에 미치는 영향에서 부분 매개 효과가 있음을 알 수 있었다. 둘째, 위험유발요인이 설비적요인에 미치는 영향에서 작업준비와 조치 여부가 유의미한 영향을 미쳤다. 따라서 안전점검은 위험유발요인이 설비적요인에 미치는 영향에서 부분 매개 효과가 있음을 알 수 있었다. 셋째, 위험유발요인이 관리적 요인에 미치는 영향에서 동바리설치와 위험성 평가가 유의미한 영향을 미쳤다. 따라서 안전점검은 위험유발요인이 관리적 요인에 미치는 영향에서 부분 매개 효과가 있음을 알 수 있었다. 넷째, 위험유발요인이 작업적요인에 미치는 영향에서 동바리설치에서만 유의미한 영향을 미쳤다. 따라서 안전점검은 위험유발요인이 작업적요인에 미치는 영향에서 완전매개 효과가 있음을 알 수 있었다. 마지막으로, 위험유발요인이 재해 저감 대책에 미치는 영향에서 작업준비와 동바리설치 그리고 조치 여부가 유의수준에서 유의미한 정(+)의 영향을 미쳤다. 마지막으로 기록유지는 유의수준에서 유의미한 부(-)의 영향을 미치는 것으로 나타났다. 결론적으로 안전점검은 위험유발요인이 관리적 요인에 미치는 영향에서 부분 매개 효과가 있음을 알 수 있다.

지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가 (Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels)

  • Ko, Jaesun
    • 한국재난정보학회 논문집
    • /
    • 제11권1호
    • /
    • pp.135-147
    • /
    • 2015
  • 최근 지하공동구(Underground Common Utility Tunnels)는 도시민이 일상생활을 영위하는데 필요한 전기, 통신, 상수도, 도시 가스, 하수도뿐만 아니라 냉난방시설, 진공 집진관, 정보처리케이블 등의 시설물을 2종 이상 공동으로 수용하기 위한 지하시설물로서 국가의 중추기능을 담당하는 시설이지만, 화재 사고시 신속한 대처가 힘들고 각종 케이블 연소시 발생하는 유독가스 및 연기에 의해 공동구 내에 진입하여 진압하기가 힘들다. 따라서 화재발생시 막대한 재산피해 및 통신두절 등 국가의 중추신경이 마비됨은 물론 시민불편사항을 초래하게 된다. 따라서 본 논문은 지금까지 발생 되어온 국내,외 공동구 화재사례에서 화재발생의 주요원인으로 전기공사로 인한 합선 및 가연성케이블에 의한 열화접촉으로 화재가 발생하는 것이 대다수를 차지하고 있음에 착안하여 실제 공동구 모형을 제작하고 화재를 재현함으로서 과학적으로 화재의 성상을 분석하는데 그 목적이 있다. 화재실험은 지하공동구 내에 정온식 감지선형 감지기(Line type fixed temperature detector), 방화문(Fire door), 연결살수설비(Connection deluge set), 및 환기설비를 설치하고, 송 배전케이블은 일정구간 내화(Fireproof)도료로 도장하며, 난방관은 내화 피복된 상태에서 실험하였다. 그 결과 Type II의 경우 최고온도가 $932^{\circ}C$로 측정되었고, 일정한 온도에서 정온식감지선형감지기가 화재위치를 정확하게 수신반에 표시되었다. 그리고 Type III의 경우인 송 배전케이블은 일정구간 내화도료로 도장한 것은 내화성능이 없는 것으로 나타났고, 내화피복(Fireproof covered)된 난방관은 약 30분 정도의 내화성능이 있는 것으로 나타났다. 또한 화재뮬레이션 결과는 실물화재시험시의 화재하중(Fire load)을 입력하여 실시한 결과로서 최고온도가 $943^{\circ}C$로 실물화재실험시의 $932^{\circ}C$와 거의 일치 하였다. 따라서 공동구 화재하중만으로 화재시뮬레이션을 실시하여 화재성상에 대한 예측이 가능한 것으로 판단되며 시뮬레이션으로 얻은 열방출률(Heat release rate), 연기층의 높이, 산소(O2), 일산화탄소(CO), 이산화탄소(CO2)의 농도 등의 결과 값들은 실제 화재실험시의 값으로 적용시킬 수 있는 것으로 판단된다. 향후 본 연구에서 구축한 국내 지하공동구 화재사고에 대한 실험자료 및 매년 지속적으로 화재사례들을 분석하여 축적하고 법 규정 및 관리 메뉴얼 등을 보완함으로써 국내 지하공동구 화재사고에 대한 보다 신뢰성 있는 정보를 제공해 줄 수 있을 것이며, 효과적이고 체계적으로 지하공동구의 신설 및 유지 관리 보수에 기여할 것으로 기대된다.