• Title/Summary/Keyword: fire point

Search Result 633, Processing Time 0.023 seconds

Studies on Overglaze Stain (釉上彩色料에 關한 硏究)

  • Lee, Chong-Keun;Park, Yong-Wan
    • Journal of the Korean Chemical Society
    • /
    • v.4 no.1
    • /
    • pp.27-37
    • /
    • 1957
  • High-fire stain is influenced by the conditions of glaze, firing atmosphere, etc. On the contrary, low fire stain is not influenced by those conditions but obtainable in arbitrary colors and it is indispensable for pottery decoration. It is difficult for us to study into the color in the sphere of result publication method and expression of color. Looking over the literature on this subject, I have been confronted with much difficulties, accordingly, I made a basic and systematic experiment as to six low-firing stains (blue, green, blue-green, brown black and yellow) and made it proper to be applied in these studies. On pigment, I confirmed the influence of the assistant coloring matter by mixing up the coloring matter and the assistant coloring matter in various proportions. On flux, I measured the melting point by making PbO-$SiO_2$ system and PbO-$B_2O_3-SiO_2$ system and decided the range of usage. Also I checked the coloring by making the pigment on laze with pigment and flux manufactured, and concluded the pigment and flux adaptation to it.

  • PDF

Study on Privatization of First-aid Service Systems in Korea (우리나라 구급제도의 민영화 도입방안에 관한 연구)

  • Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.108-115
    • /
    • 2008
  • This research put the point on deducing problems of our first-aid system and proposing improvement program. Now first-aid system has lots of weakness, such as short of speciality, limitation to raise finance. To improve these first-aid infrastructure must be expanded and improved, and it also needs enough effort for improvement of quality and arrangement of emergency medical treatment speciality. We should introduce commission to first-aid system so raise fund and make use of speciality. And also we should organize private partnership with hospitals or insurance companies, so that we can construct united system of first-aid system.

Design for Pressurizing System about Vestibule by Stack Effect & Engineering Analysis - Focused on Case Study - (굴뚝효과와 공학적분석에 의한 부속실 가압시스템 설계 - 사례를 중심으로 -)

  • Kim, Yong-Kwang
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.145-153
    • /
    • 2009
  • We are generally applicate smoke control only vestibule about special escape staircase, it is one of some smoke control model of NFSC 501A. But there are some point at issue in this system. The smoke control system on supervision field of writer is smoke control only vestibule same as the other resemble field. Writer studied in the concrete to find a solution at this issue, and derived a conclusion the most reasonable system on the field is "same time smoke control for staircase and vestibule" by the engineering analysis considering stack effect.

A Study on the Electrical Unique point due to the Dielectric breakdown at the Surface of a Circuit Breaker (차단기의 표면에서 절연파괴에 의한 전기적 특이점에 관한 연구)

  • Kim, Dong-Ook;Kim, M.G.;Kim, M.S.;Kim, H.S.
    • Congress of the korean instutite of fire investigation
    • /
    • 2010.12a
    • /
    • pp.239-248
    • /
    • 2010
  • 2008년도 사고설비별 전기화재 발생현황을 살펴보면 전기화재중 전기배선 및 배선기구에서 발화한 화재가 2,540건으로 전기화재 발생 중 25.95 %를 점유하였다. 또한 사고전압별 전기화재 발생현황으로 220/380 V에서 화재가 6,320건(64.4 %)으로 전기화재의 대부분을 점유하였다. 전기화재는 단락, 과전류, 접촉불량, 트래킹 등 9가지로 분류할 수 있다. 이러한 전기로부터 재해를 막기 위하여 누전차단기나 배선용차단기를 사용하여 일부의 전기화재 원인을 차단할 수 있으나 차단기 자체에서 발생하는 원인에 대하여는 보호할 전기기기가 부재하다. 본 논문에서는 최근 실화법의 적용으로 일반적으로 전기화재로 취급되어지지만 보다 세밀히 조사하면 제조결함, 사용자 부주의, 설치 및 환경에 따른 위험성을 분석하고 전기설비에서의 화재 발생에 대한 예방대책에 활용할 수 있도록 연구하였다.

  • PDF

An Study on control of explosion pressure in enclosure (내압 폭발 압력 조정에 관한 연구)

  • Kim, Hong-Sik;Oh, Dae-Hee;Oh, Kyu-Hyung;Choi, Beom-Shik;Lee, Sung-Eun;Moon, Young-Gil
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.189-193
    • /
    • 2008
  • A Control variables of explosion pressure in enclosure are a type of explosive gas, concentration of mixture, open area in enclosure. In this study, be performed to test inner explosion pressure of Blast Proof Door by the control variables of explosion pressure. and this real explosion test of Blast Proof Door have a good point in test of the against pressure method that can be obtained dynamic pressure or not static pressure.

  • PDF

Risk Evaluation of Biodiesel (바이오디젤연료 위험성평가)

  • Kwon, Kyung-Ok
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.79-82
    • /
    • 2008
  • Biodiesel is manufactured from vegetable oils, etc. in reaction with methanol so that the product of biodiesel may be dangerous due to the methanol remained of it. The risks of methanol remained in biodiesel were studied by measuring flash points and dynamic viscosity to some samples of biodiesel by adding methanol to a certain percentage of. The results of flash points of biodiesel are decreased in accordance with increasing of methanol in biodiesel and also decreasing the dynamic viscosity. It was shown that the risks of explosion of biodiesel are significantly high due to lower flash points resulted from methanol remained in biodiesel fuel as a reactant or adding to biodiesel for reduction of viscosity.

A Study on Lighting Emergency Lamp using Photovoltaic Generation System (태양광발전시스템을 이용한 유도등용 헝광램프의 점등에 관한 연구)

  • 이상집;성낙규;이승환;오봉환;백동현;이훈구;한경희
    • Fire Science and Engineering
    • /
    • v.14 no.1
    • /
    • pp.22-26
    • /
    • 2000
  • Emergency lamp is installation usage on an emergency situation or firing. It's an offer at least of brightness. It's lighting to common source usually. It's transferred to reserve battery on power stoppage. This emergency lamp is lighted from solar cell system. The solar cell should be operated at the maximum power point. This paper proposes the new control method that half-bridge inverter using the solar cell can operate emergency lamp.

  • PDF

Study on the Flash Point and Spontaneous Ignition Determination of 2-Propanol and O-xylene Mixtures (2-프로판올과 O-xylene 혼합물질의 인화점과 자연발화 측정에 관한 연구)

  • Kim, Tae-Young;Mok, Yeon-Su;Choi, Jae-Wook
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.360-363
    • /
    • 2011
  • 본 연구는 2-Propanol과 O-xylene의 혼합물의 인화점과 자연발화에 관한 연구이다. 인화점의 경우 2-Propanol과 O-xylene의 혼합비를 변화하여 측정하였으며, 2-Propanol은 $12^{\circ}C$를 구하였고, O-xylene는 $32^{\circ}C$를 구하였다. 자연발화의 경우 2-Propanol과 O-xylene의 농도를 변화시켜 혼합한 시료를 만들어 최저발화온도와 순간발화온도를 측정하였다.

  • PDF

Analysis of Defense Industry Infrastructure in Fire Power Area Using Multidimensional Preference Analysis (다차원선호도분석을 이용한 화력분야 방위산업기반 분석)

  • Choi, Myung-Jin;Lee, Sang-Heon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.99-104
    • /
    • 2010
  • MDPREF(Multidimensional Preference Analysis) is a program for analysis of preferences. It is what is known as a vector model. This means that the objective of the MDPREF analysis is to identify a perceptual map displaying subject(attribute) vectors. To form the subject vectors visually, lines are drawn from the origin of the plot to each subject point. We analysis the defense industry infrastructure in fire power area by using MDPREF.

The study of the efficiency augmentation model under Urban system - a point Taegu subway fire accident probelm and countermeasure - (대구지하철 화재사고를 통한 도시철도의 효율성 증대 모형에 관한 연구)

  • Jung Ye-Seoung
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.239-250
    • /
    • 2003
  • It explained the cause and a process of Taegu subway fire accident in this report. Will reach and to lead it analyzed the structure and actual proof problem which it follows in Urban construction and the operation of Korea. The Urban is operated efficiently to be respected, it demands a security division order to become fixed the culture which it uses, it intercepts the misfortune due to the human being the setup for with the destroyer it is possible. This report will become the place help which reappraises all systems against the construction and the operation of the Urban system.

  • PDF