• 제목/요약/키워드: fire point

검색결과 638건 처리시간 0.034초

Bayesian Change-point Model for ARCH

  • Nam, Seung-Min;Kim, Ju-Won;Cho, Sin-Sup
    • Communications for Statistical Applications and Methods
    • /
    • 제13권3호
    • /
    • pp.491-501
    • /
    • 2006
  • We consider a multiple change point model with autoregressive conditional heteroscedasticity (ARCH). The model assumes that all or the part of the parameters in the ARCH equation change over time. The occurrence of the change points is modelled as the discrete time Markov process with unknown transition probabilities. The model is estimated by Markov chain Monte Carlo methods based on the approach of Chib (1998). Simulation is performed using a variant of perfect sampling algorithm to achieve the accuracy and efficiency. We apply the proposed model to the simulated data for verifying the usefulness of the model.

노말트리데칸의 연소특성치의 적정성 고찰 (The Investigation of Compatibility of Combustible Characteristics for n-Tridecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.83-88
    • /
    • 2012
  • For the safe handling of n-tridecane, the lower flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. Also lower explosion limits by the lower flash points were calculated. The lower flash points of n-tridecane by using closed-cup tester were experimented $92^{\circ}C$ and $96^{\circ}C$. The lower flash points and fire point of n-tridecane by using open cup tester were experimented 100 oC and 103 oC, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-tridecane. The experimental AIT of n-tridecane was 223 oC. The calculated lower explosion limit by using measured lower flash point 92 oC for n-tridecane was 0.6 Vol.%.

첨가제 사용에 의한 Epoxy Resin 용액의 인화점 측정 (Measurement of Flash Points of Epoxy Resin Solutions by Using Additives)

  • 하동명
    • 한국안전학회지
    • /
    • 제22권3호
    • /
    • pp.22-27
    • /
    • 2007
  • The knowledge of the flash point of the various liquid substances is required because of process safety and control in industrial fire protection. The epoxy resin is one of versatile resins that has wide selection of using curing agents and additives to achieve various applications such as coatings, adhesives, interior materials, reinforced plastics and electrical insulation. In this study, the lower flash points for p-xylene+epoxy resin, o-xylene+epoxy resin and n-butanol+epoxy resin systems were measured by using Pensky-Martens closed cup tester. The lower flash points for p-xylene+epoxy resin, o-xylene+epoxy resin and n-butanol+epoxy resin systems rapidly increased 80wt%, 90wt% and 95wt% of epoxy resin concentration, respectively. This results serve as a guide to estimate flash point of any epoxy resin solution.

전기장판 열선 결함에 의한 전기화재 원인분석 (Fire Cause Analysis on Electric Pad Due to Defect of Hot Wires)

  • 송재용;사승훈;남정우;김진표;조영진;오부열
    • 한국안전학회지
    • /
    • 제27권2호
    • /
    • pp.7-12
    • /
    • 2012
  • This paper describes electrical fire on electric pad caused by defect of hot wires. We analyzed two type electric pad using by carbon type hot wire and magnetic shielded type hot wire. First, a carbon type hot wires electric pad is virtually impossible to connect hot wire as a method of electrical welding or soldering. In order to connect between hot wires, that has to splice carbon type material connector. If junction of hot wires was occurrence of poor connection on electric pad, it increase contact resistance on this junction point. With increasing contact resistance, junction of hot wires on electric pad generates local heating and finally leads to electrical fire. An electric pad using by a magnetic shielded type hot wire happened local heating on signal wire for sensing temperature-rise caused by applying current for magnetic shielded. With increasing local heating of signal wire, insulated coating of hot wire was melted. Finally the magnetic shielded type hot wire electric pad lead to electrical fire with breakdown between signal wire and hot wire. In this paper, we analyzed shape of damage in hot wire caused by electrical local heating and investigated fire cause on electric pad due to defect of hot wires.

휘도비 측정을 통한 유도등의 경년변화 연구 (A Study on the Aging Change of Exit Light by Measuring the Ratio of Luminance)

  • 정종진
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.181-185
    • /
    • 2019
  • 본 연구에서는 유도등의 광원과 경년변화에 따른 휘도성능을 분석하기 위하여 사무실, 상가, 병원, 공장 등에 설치된 유도등을 발취하여 CCFL, LED광원별 경년변화에 따른 휘도성능을 분석하였다. 이는 유도등과 같은 전기적 특성을 갖는 소방제품은 설치된 곳의 주위온도나 습도, 먼지 등이 그 성능에 변화를 줄 수 있기 때문에 설치장소별로 발취하여 그 특성을 분석하였다. 실험결과, CCFL유도등은 대형, 중형, 소형 모두 '휘도비 2'정도의 값을 나타내었다. 기술기준 규정값이 '휘도비 9이하'인 점을 감안할 때 매우 양호한 값을 나타냈으며, 경년변화에 의한 휘도비 변화도 거의 없음을 확인할 수 있었다. LED유도등은 '휘도비 5'정도의 값을 나타냈으며, 이는 표시면의 빛이 균일하지 못함을 뜻한다. 또한 경년변화에 의한 휘도비 변화는 거의 없으나, 휘도비의 값은 LED유도등보다 크게 나타났다. 이는 시각적인 측면에서는 만족스럽지 못한 결과이다. 이를 개선하기 위해서는 LED광원의 빛 분산이 필요하며 휘도비 관련 규정을 강화할 필요가 있다.

A Study on Evacuation Safety of Trainingship HANBADA using FDS & maritimeEXODUS

  • KIM, Won-Ouk;HAN, Ki-Young;KIM, Dae-Hee
    • 해양환경안전학회지
    • /
    • 제23권3호
    • /
    • pp.266-272
    • /
    • 2017
  • In this study, it was simulated and analyzed the evacuation safety to identify the cadets' evacuation time by using maritimeEXODUS which is applied IMO MSC.1/Circ.1238 theory as well as the trim and heel which are the major factor of reducing the ship evacuation speed. In addition, this study carried out a simulation through the special program for fire analysis - FDS (Fire Dynamics Simulator) in order to find the effective evacuation time, i.e. life survival time. Particularly, this study did comparative analysis of the influence on the survival of cadets based on the collected simulation data by fire size and sort. As a result of the analysis, It was analyzed the Evacuation Allowable Limit Temperature $60^{\circ}C$ and resulted that there is no influence in evacuation by temperature. As a result of the analysis on visibility evacuation limit 5 m, it was found that the only one evacuation rallying point could not meet the evacuation safety. However, it derived the perfect evacuation safety under the condition of two rallying points available on wood fire. In case of Kerosene, it was satisfied the evacuation safety if the heeling was under $10^{\circ}$. Moreover, it could not meet the evacuation safety by evacuating through upper deck although there were two evacuation rallying points. When it was set by the lifeboat descending maximum angle-$20^{\circ}heel$ and $10^{\circ}trim$ which was described in SOLAS regulation, it was simulated that the wood fire having two evacuation rallying points in the center of the ship satisfied the evacuation safety.

특별피난계단 부속실 제연설비의 방연풍속 측정 방법에 관한 연구 (Study on Measurement Method of Air Egress Velocity in Vestibule of Smoke Control System)

  • 이수경;홍대화
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.85-90
    • /
    • 2011
  • 본 연구는 국내 고층건물 특별피난계단의 부속실에 설치되는 급기가압 제연시스템에서 화재 발생 시 피난을 위하여 출입문이 개방되었을 경우 형성되는 방연풍속의 특성을 FDS를 이용하여 해석하였고, 해석 결과를 분산분석으로 기류의 특성에 따른 측정 방안을 분석하고자 한다. 부속실과 같은 구획공간의 설계 조건에서 급기댐퍼에서 토출되는 보충량은 심한 와류를 형성하고 형성된 와류의 범위 안에 출입문이 존재할 경우 비정상적인 기체의 유동이 출입문지점에 발생한다는 것을 선행연구를 통하여 확인할 수 있었다. 국가화재안전기준 NFSC 501A에서 방연풍속을 측정할 때에는 출입문의 개방에 따른 개구부를 대칭적으로 균등 분할하는 10 이상의 지점에서 측정하는 풍속의 평균치로 할 것으로 정하고 있으나 이러한 조건에서는 출입구 상부 지점에 기류의 유입 현상을 파악하기 어렵고 풍속의 편차가 심하기 때문에 측정점을 공기조화설비의 시험조정 평가 기술기준에서 제시하는 64점 이상으로 세분화하여 측정하여야 할 것이다.

PTC 서미스터의 온도특성을 이용한 전기안전 제어장치 개발에 관한 연구 (A Study on Development of Electric Safety Control Apparatus by Using Thermal Characteristics of PTC Thermistor)

  • 곽동걸;정도영
    • 한국화재소방학회논문지
    • /
    • 제21권4호
    • /
    • pp.65-71
    • /
    • 2007
  • 본 논문에서는 PTC 서미스터의 전기적 특성과 온도특성을 이용하여 각종 전기화재 및 전기사고를 예방 보호하는 전기안전 제어장치에 대해 연구된다. PTC(Positive Temperature Coefficient) 서미스터는 온도변화에 따른 저항특성이 정(+)온도계수를 갖는 특징이 있다. 이러한 PTC는 정온도계수를 갖는 $BaTiO_3$계 세라믹스의 정방정계-입방정계 구조를 가지고 상변이점인 큐리(Curie)온도 이상으로 온도가 증가하면 저항이 급격히 증가하는 현상을 보인다. 본 논문에서는 이러한 정저항 온도특성과 자체 발열특성을 갖는 PTC 서미스터를 전기단락사고나 과부하사고 등의 전기사고의 감지센서로 이용하여 전기화재사고로부터 보호하는 제어시스템에 대해 제안한다. 그 결과 기존에 상용되는 차단기들의 빈번한 오동작과 비신뢰성, 저응답특성 등으로 발생되는 전기화재 및 전기재해의 문제점을 해결한다. 또한 제안한 전기안전장치는 다양한 실험결과를 통해 이론적 해석의 타당성이 입증된다.

LP가스 폭발로부터 화재로의 천이에 관한 연구 (A Study on the Explosion to Fire Transition Phenomena of Liquidfied Petroleum Gas)

  • 오규형;이춘하
    • 한국안전학회지
    • /
    • 제8권4호
    • /
    • pp.107-113
    • /
    • 1993
  • Small rectangular explosion chamber of its size 25cmX25cmX32cm with a circular bursting diaphram at the top was used to study the mechanism of gas explosion to fire transition phenomena, the process of ignition of solid combustibles during a gas explosion. To visulize the explosion to fire transition phenomena, transparent acryl window and high speed camera system were used. The test piece of solid combustible in this experiments was a 5cm$\times$5cm square sheet of newspaper which was placed in the explosion chamber filled with a LPG-air mixture. The mixture was ignited by an electric spark at the center of the chamber. Explosion to fire transition phenomena and the behavior of out flow and in flow of gas through the opening yielded by bursting the diaphram was visualized with shlieren system and without shlieren system. Diameter of a bursting dlaphram at the top of the explosion chamber was varied 5cm, 10cm, and 15cm, and the position of test piece were varied with 6 point. Explosion pressure was measured with strain type pressure transducer, and the weight difference of the test piece before and after each experimental run was measured. By comparing the weight difference of solid combustibles before and after the experiment and the behavior of out flow and inflow of gas after explosion, it was found that the possibility of ignition was depends on the LPG-air mixture concentration and the exposure period of test piece to the burnt gas. Test result of this experiments it was found that the main factor of this phenomena are that heat transfer to the test piece, and the pyrolysis reaction of test piece. Based on the results, the mechanism of the explosion to fire transition phenomena were inferred ; gas explosion- heat transfer to solid combustibiles ; pyrolysis reaction of solid combutibles : air inflow ; mixing of the pyroly gas with air ignition.

  • PDF

Loop형 스프링클러 설비의 수리계산 방법에 대한 제시 (A Presentation on the Manual Hydraulic Calculation Method of the Loop Type Fire Sprinkler System)

  • 정기신
    • 한국화재소방학회논문지
    • /
    • 제29권1호
    • /
    • pp.73-79
    • /
    • 2015
  • 스프링클러 설비의 설계방법은 크게 3가지로 분류한다. 가지관을 서로 연결하여 사다리형태로 배관을 설치하는 Grid형과 가지관은 연결하지 않고 교차배관만을 연결하는 Loop형 그리고 가장 일반적으로 사용되는 Tree형이 있다. 이 중 Grid형은 아주 간단한 것을 제외하고는 컴퓨터프로그램으로 마찰손실을 계산하여야 하지만 Loop형의 경우는 프로그램의 도움 없이 설계자가 직접 계산하여 마찰손실에 따른 필요압력과 소요유량을 산출할 수 있다. Loop형 설비의 경우 소화수 공급이 2방향으로 분리되어 마찰손실이 작아지고 헤드간 방출압력의 차이가 Tree형보다 작게 되어 살수분포가 우수하게 되며 작은 마찰손실에 의한 소구경의 배관을 사용하여 자재비와 인건비가 절감되므로 Loop형에 의한 스프링클러의 설계가 Tree형 설비에 비해 성능과 경제성에서 우수한 설계 방법이다. 하지만 Loop형 설비의 설계는 설계방법이 잘 알려져 있지 않아 거의 이루어지지 않고 있다. 본 논문에서는 Tree형 보다 우수한 Loop형 설비의 설계방법을 설명하여 많은 설계자가 성능과 경제면에서 우수한 Loop형 설계를 쉽게, 널리 사용하게 하고자 하였다.