• Title/Summary/Keyword: fire gap control

Search Result 13, Processing Time 0.022 seconds

Fine Gap Control Using Pneumatic Servo System (공압서보시스템에 의한 미세 간극제어 시스템 설계)

  • 김동환;김영진;정대화
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.45-56
    • /
    • 2002
  • A pneumatic servo system requiring a fine gap control in a photo-electric sensor which is used for a LCD array detection device is introduced. The gap controlled by the pneumatic servo system remains within around 50~80 ${\mu}{\textrm}{m}$, and the system possesses an effect to eliminate undesirable particles on the LCD plate by blowing air out. The air flow rate is initially controlled by a servo valve and expanded by a booster valve, thus the controlled air pressure contributes to maintaining an appropriate gap between the LCD plate and photo-electric sensor An air floating plate of two degrees of freedom is designed and fabricated, and a fine tilting motion control is also implemented by assigning different gap commands. The pressure control and direct gap control are proposed, and each performance is verified experimentally.

Planning Controls for Land Use Safety (토지이용의 위험성 제어계획 -사용 밀도에 따른 기준치 설정의 접근방법-)

  • 노삼규
    • Fire Science and Engineering
    • /
    • v.10 no.2
    • /
    • pp.20-27
    • /
    • 1996
  • This paper discussed the limit of existing safety controls where the use of land around hazardous industry. There is a gap between engineering evaluation of acceptable criteria for loss reduction and risk exposure to the areas of high risk outside plants from the aspects of risk perception. The paper performed how land use safety could be designed between the density of uses with the duration of risk exposure by type of land use. It concluded the needs of multi-dimensional presentation for an appropriate risk controls on existing and future land use safety.

  • PDF

Study of Smoke Behavior and Differential Pressure in the Refuge Safety Area According to Damper Capacity of Smoke Control (제연댐퍼 송풍량에 따른 피난 안전 구역 차압 및 연기 거동 특성 연구)

  • Lee, Jae-Bin;Moon, Joo-Hyun;Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2011
  • In this study, we calculated the smoke movement at the fire area of the refuge floor which has the refuge safety area in case of fire in the high rise building by using a computational fluid dynamics (CFD) code of FLUENT (ver. 13.0). The buoyancy plume was applied using the temperature and flow velocity which represent 10 MW heat release rate in order to describe the fire, and the smoke movement was predicted using a species conservation equation. The pressurization system of smoke control was adopted with smoke control damper in refuge safety area, at the result, it is confirmed that the damper capacity was enough to smoke control in which the flow rate of supply was applied 25 $m^3/s$ in the case of the door at fire area opened only, and 50 $m^3/s$ in the doors at the fire area and lobby both opened case. They were satisfied in NFSC 501-A. Even though the door of fire area closed, there were smoke leakages at the gap between the door and wall. In addition, the refugee could be isolated in the fire area when the door of fire area closed during smoke control in the case of using the high damper flow rate of supply, 50 $m^3/s$. Therefore the proper damper flow rate of supply are needed in order to prevent the damage of refugee and this study proposes the suitable condition of damper capacity according to refuge scenario.

Vegetation Change after A Forest Fire in a Rural Japanese Red Pine Forest and Applications of Effective Microorganism (농촌 소나무림에서 산불에 의한 식생변화와 유용미생물의 적용)

  • Yeo, Ji Sean;Kim, Kee Dae
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.4
    • /
    • pp.46-56
    • /
    • 2008
  • This study examined the natural restoration of vegetation through monitoring of the development of a vegetation community from 2006 through 2007 after a forest fire. Approximately 5,000 $m^2$ in a forest near Topyeon-ri, Kangnae-myeon, Chungcheongbuk-do with Japanese red pine (Pinus densiflora) forest and its floor vegetation had been completely burned by a fire in April 2005. This area and another nearby Japanese red pine forest were selected as the experiment site and the control site, respectively. Vegetation survey was conducted at the experiment site and the control site. A seed bank experiment was carried out in the greenhouse to examine underground vegetation. Effective microorganism(EM) was applied to the seed bank experiment to estimate its effects on the direction of ecological succession. According to the results, a total of 36 plant species including shrub and herbaceous species were discovered in the experiment site. Quercus serrata, Lespedeza cyrtobotrya, and Castanea crenata, Rubus crataegifolius, Oplismenus undulatifolius, and Carex lanceolata were among the most abundant species. Biomass in the experiment site reached 2.4 times biomass than those in the control site, indicating the productivities of shrub and herbaceous layers are better in the experiment site. According to the result of the soil seed bank experiment of the experiment site, a total of 182 plants of 14 species were recorded. In addition, a total of 13 plants of 2 species were found from soil seed bank of the experiment site applied by EM. If EM is applied to the burned site, it will control the budding of herbaceous plants, creating the gap between herbaceous plants. This loss of competition is expected to help the restoration of trees in the burned area.

The Leakage Crack Calculation of the Fire Door and the Stack Effect Analysis (방화문의 누설틈새 계산 및 연돌효과 분석)

  • Kim, Il-Young;Kwon, Chang-Hee
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.46-53
    • /
    • 2013
  • The architecture environment has changed. The corresponding design criteria should be changed. From July 27th, 2005 the Korea Standard of the fire door changed concerning the smoke resistance test which made the door gap structure more elaborate. However the National Fire Safety Codes are applied by the old data's of England. Which in case differs in the actual construction to the blue print, making the safety standard too excessive. Analyze the results and the phenomenon that occurs due to the difference between design and reality. The National Fire Safety Codes should be revised to leakage crack calculation is presented. Difference of the air flow for the smoke protection due to the stack effect analyzed. Living patterns and evacuation patterns of the apartment reflect and reasonable air flow measurement method are presented.

Planning for Safely Control on Hazardous Material Distribution Depot.

  • Roh, S.K.;Jun, S.W.;Kang, T.H.;Seo, Y.M.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.260-268
    • /
    • 1997
  • The safety of LPG vessel storage has been simply designed and controled with blast wave barrier structure concept regardless of its quantity or hazardous situation. The limit of regal controls on LPG vessel storage need to be identified in terms of safety buffer distance from LPG explosion. The level of overpressure effect and heat radiation In the safety structure and neighbouring human activity required to be estimated to find the gap between existing controls on such storage. To this content the paper discuss the issues on the approach In the blast wave barrier and safety separation distances.

  • PDF

Planning for Safety Control on LPG Distribution Depot (LPG 판매업소의 위험성 제어계획)

  • 노삼규;전성우;강태희;서영민
    • Fire Science and Engineering
    • /
    • v.12 no.4
    • /
    • pp.21-30
    • /
    • 1998
  • The safety of LPG vessel storage has been simply designed and controled with blast wave barrier structure concept regardless of its quantity or hazardous situation. The limit of regal controls on LPG vessel storage need to be identified in terms of safety buffer distance from LPG explosion. The level of overpressure effect and heat radiation to the neighbouring structure and human activity required to be estimated to find the gap between existing controls on such storage. PHAST and IAEA manual for risk rankings and assessment had been applied to get the required safety distance for neighbouring facilities, Japanese legal control for such facilities were also investigated. To this context the issues on LPG vessel storage required additional safety distance between existing blast wave barrier structure and safety separation distances.

  • PDF

A Study on the Relation between Knowledge and Attitude on Coronavirus Disease-19 (COVID-19) and Infection Control Performance of Paramedic students (응급구조(학)과 대학생의 코로나바이러스감염증-19(COVID-19)에 대한 지식 및 태도와 감염관리 수행도 간의 관련성 연구)

  • Park Dae-Sung;Kim Gap-Seon;Lee Man-Jin;Kim Ye-Rim
    • Journal of Advanced Technology Convergence
    • /
    • v.2 no.3
    • /
    • pp.25-32
    • /
    • 2023
  • This study was conducted to find out the relationship between knowledge and attitudes about COVID-19 and infection control performance among college students in paramedicine. The subjects of the study were 154 university students attending a 3-4 year paramedicine located in Gwangju Metropolitan City, Jeollabuk-do Province, and the collected data were frequency, percentage, sum, average and It was analyzed by standard deviation, t-test, ANOVA(Scheffe), Pearson's Correlation Coefficient, and Multiple Linear Regression. The order of attitude and knowledge about COVID-19 affected the infection control performance of college students in the paramedicine. Therefore, it is necessary to develop and apply regular or non-regular curriculum and multidisciplinary curriculum that can improve knowledge and attitudes about COVID-19 in order to improve the infection control performance of paramedic students.

Producing Firefighting Vulnerability Maps Using GIS - A Case Study of Dalseo-gu, Daegu - (GIS를 이용한 화재진압 취약성 지도 제작 - 대구광역시 달서구를 사례로 -)

  • KIM, Sung-Jae;CHOI, Gap-Yong;CHANG, Eun-Mi;SONG, Wan-Young
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.3
    • /
    • pp.11-20
    • /
    • 2015
  • Fire incidents, which occur every year, cause huge damage to properties and humans. Significant time and costs have been invested in minimizing and responding to such accidents. With the recent advances in the development of spatial information, in the firefighting field, studies have been conducted to effectively bring fires under control using GIS(Geographic Information System). Most of such studies, however, focused on individual analyses of firefighting-related factors, but comprehensive research on the vulnerability factors in fire control activities, a major part of firefighting activity, has yet to be done. This study sought to pinpoint and analyze the factors that obstruct fire controlling, and to gather relevant data and create GIS-based databases. Based on such database, GIS-based overlay analysis was conducted to produce a fire control vulnerability map. The findings of this study will enable a quantitative analysis of firefighting obstruction factors to assist the personnel engaging in firefighting in rational decision-making, such as in formulating a firefighting operation plan for securing golden time.