목조 문화재 건축물의 화재 방재를 위한 조사 연구 (A Study on the Methods of Fire-Safety in Cultural Property Wooden Buildings)

  • 장형순;조원석;김흥기
    • 한국농촌건축학회논문집
    • /
    • 제10권4호
    • /
    • pp.25-32
    • /
    • 2008
  • The prevention of disasters in cultural property is very important management and historical duties. The reason can't be measured values with monetary scale of our contemporary. Therefore, this paper was considered fire-safety as one of terrible threat-disasters about the wooden buildings. This research deal with 47 cases cultural property wooden building by whole investigation(field survey and interview) in Gangnung province. The most buildings have basic fire extinguisher; ABC powder. A few buildings are rarely installed fire extinguishing equipments; outdoor fire hydrant, heat sensor, ground sprinkler, CO2-hose-reel. But these state is very insufficient for the fire-safety in cultural property wooden buildings. Specially as particular attention in province, forest fire of regional characteristic have close relation with cultural property fire. The majority of factor against forest and building fire is to provide monitoring and security system; CCTV, Fence, Sensor, Alarm and paid guard man against incendiary. Ultimately it is necessary to construct comprehensive disaster prevention system with the organic cooperation such as National Emergency Management Agency, Cultural Heritage Administration, Forest Service, local government officials and regional citizen.

  • PDF

소화약제를 이용한 자동차 엔진룸 화재 실험에 관한 연구 (An Experimental Study on the Automobile Engine Room Fire Using the Extinguishing Agents)

  • 한용택;김동호;권성필
    • 한국화재소방학회논문지
    • /
    • 제28권4호
    • /
    • pp.1-7
    • /
    • 2014
  • 자동차의 엔진룸의 내부를 살펴보면 여러 가지의 장치 및 장비가 복잡하게 설치되어 있고 각종 오일 등의 인화물질을 포함하고 있어 재발화 가능성이 매우 높다. 또한, 폭발가능성도 높기 때문에 운전자나 탑승자가 보닛을 열고 엔진룸에 직접 분말 소화기를 분사하는 방식으로는 한계가 있다. 따라서 엔진룸 내부에서 화재를 감지하여 소화약제를 분사한 뒤, 화재를 진화하는 소화시스템과 엔진룸 내부의 고열에 견딜 수 있고, HFC-227ea를 포함하는 충분한 점성을 가진 폼 형태의 소화약제를 개발 및 시험하였다. 그리고 포소화약제가 가지고 있는 소화원리인 질식 및 냉각효과와 HFC-227ea가 가진 부촉매효과를 동시에 이끌어 내고, 소화 후에도 분말 소화기처럼 잔존물에 의한 2차 피해가 없는 맞춤형 소화약제를 개발하였으며, 차량을 이용한 충돌실험을 통하여 방출이 완료된 후에도 이물질 없이 소화약제를 제거할 수 있는 장점이 존재하는 실험결과를 획득하였다.

자동확산소화장치의 이격거리에 따른 소화성능평가연구 (Fire Extinguishing Capability of an Automatic Spreading Fire Extinguisher in Accordance with Horizontal Distance from a Fire Source)

  • 곽지현;김동석;구재현
    • 한국화재소방학회논문지
    • /
    • 제27권5호
    • /
    • pp.38-43
    • /
    • 2013
  • 보일러실이나 세탁소, 또는 음식점과 다중이용업소의 주방에 주로 설치하는 자동확산소화장치는 화재발생 시 화염이나 열에 의해 자동으로 약제가 방출되어 화재를 진압하는 소화기구 중 하나이다. 이 소화장치는 공칭방호면적에 해당하는 소화능력을 가지고 있으므로 방호대상물이 이 범위를 벗어나 있으면 유효한 화재진압이 보장되지 않지만 현행 기준에는 바닥면적에 따른 설치갯수만 요구하고 있다. 따라서 방호대상물과의 이격거리에 따라 소화성능은 달라지게 되며 이에 대한 특성을 고찰하고자 천장높이가 2.5 m인 모형화재실에 본 소화장치를 설치하고 A급, B급 모형가연물과의 수평이격거리에 따른 소화실험을 실시하였다. 실험결과 일반가연물과 유류가연물을 모두 확실하게 소화할 수 있는 최대수평이격거리는 약 30 cm인 것으로 나타났다.

실내 화재 진압 및 인명구조 기술 개발 (Development of Eire Extinguishment and Life-saving Technology for Indoor Environment)

  • 오주환;최재석;이우준
    • 제어로봇시스템학회논문지
    • /
    • 제13권2호
    • /
    • pp.108-113
    • /
    • 2007
  • The robot introduced in this paper is the Fire-Extinguishing Rescue Robot for indoor work which is considered to be a part of the Operation for Future Developmental Power. It is briefly introduced about the background of how we began this project, our goals, where we are today and what we would like to achieve from now on. Main contents include introduction to the equipments for Fire-Extinguishing Rescue robots that have been developed in advanced countries and the compositional concept of the developmental process, the GUI schematic, searching methods for fire inside a house, mechanical schematic and the present conditions of how the core technologies are developing through.

태양광 발전 시스템의 화재 위험 감소 방안에 관한 이론적 연구 (Study on Theoretical Research to Reduce Fire Risk of Solar Power System)

  • 박경진;이근출;이봉우
    • 한국산업융합학회 논문집
    • /
    • 제23권2_2호
    • /
    • pp.219-224
    • /
    • 2020
  • This study is based on the principle of solar power system and fire breakout. The result of the survey indicates that a solar power system is vulnerable to fire due to lack of maintenance after the installation. Currently the national fire safety agency does not have standards and legal provisions for the installation and maintenance of solar power facilities. Therefore, it increases the risk of fire breakouts as well as possibility of electric shock for the firefighters during fire fighting. This results possible damages to the human and equipments. In this study is proposing an automatic fire extinguishing system to reduce the power generation of solar panels during fire breakouts. Also, propose an over load current alarm system and fire prevention measures for fire fighters. The results of this study will be used as basic data for further fire testing of solar power systems.

오픈소스 하드웨어를 사용한 저비용 열화상 잔불탐지 장치 개발 (Development of a Low-Cost Thermal Image Hidden Fire Detector Using Open Source Hardware)

  • Moon, Sangook
    • 한국정보통신학회논문지
    • /
    • 제23권12호
    • /
    • pp.1742-1745
    • /
    • 2019
  • Hidden flame detection after allegedly extinguishing a fire cannot be emphasized enough. There are a few commercial hidden fire detection equipments which are imported, but the cost is relatively high. In this contribution, we propose a development of a low-cost, high-performance hidden flame detector using open-source hardware/software. We use Raspberry-pi based hardware board equipped with a TFT touch-screen LCD, a 3G modem, and an attachable battery device altogether integrated in a plastic case fabricated with a 3D printer. The proposed hidden flame detector shows the same performance of a commercial product FLIR E5 while consuming less than a half of the cost.

원자력발전소 화재방호와 소방시설 기술기준 적용에 대한 고찰 (A Study on Fire Protection in Nuclear Power Plants and Application of the Code and Standards for Fire Protection Systems)

  • 김위경;정기신
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.38-44
    • /
    • 2012
  • 원자력발전소 화재방호의 목표는 화재 시 원자로의 안전정지 상태를 유지하여 환경으로의 방사성물질 누출을 최소화하며, 종사자 인명안전 및 재산을 보호하는데 있다. 소방시설은 발생된 화재를 조기 감지 및 진압하여 화재로 인한 피해를 완화시킬 수 있는 심층방어개념에 입각한 중요한 방어수단의 하나이다. 그러나 소방방재청에서 제시하고 있는 소방시설 설치기준이 원자력발전소에 특화되어 있지 않아 인허가 시 별도의 심의 절차가 요구되고 있다. 또한, 성능위주설계와 같은 규정은 작업자의 인구밀도가 비교적 낮은 원자력발전소에 적용하는데 어려움이 있다. 이 논문에서는 원전 화재방호와 관련된 법령의 상세 검토를 통하여 도출된 근본적인 문제점과 KEPIC FPN의 국내 원전 적용성에 대한 평가를 통하여 소방시설에 대한 기술기준에 대한 개선방향을 제시하였다.

진화거리에 따른 산불 진화 장비의 정량화 평가 (Quantitative Evaluation of Forest Fire Suppression Equipments as the Extinguishing Distance)

  • 김정훈;김장환;김경하;이병두;신재연
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.426-429
    • /
    • 2011
  • 산불 발생 시 진화를 위해 사용되는 주력 지상 진화장비 중 동력펌프 2종과 진화 차량을 대상으로 수원지로부터 발화 지점까지 진화거리에 따른 주요 성능을 측정하였다. 성능 측정은 분당 토출량, 토출 최대압력, 수평 분사거리, 수직 분사거리의 4개 항목이었으며, 노즐의 종류에 따른 영향을 동시에 고려하였다. 산불 진화 시 적정 거리를 측정한 결과 소형펌프의 경우 600m, 중형펌프의 경우 800~1000m 정도인 것으로 나타났다. 또한 분당 토출량은 3가지 펌프 모두 50m에서 1000m로 연결할 경우 52~62% 감소가 일어나며, 최대 토출압력은 26~30% 상승되어 부하 발생시 고압호스의 파손 우려도 있는 것을 알 수 있었다. 실험을 통해 소형펌프의 경우는 주 산불진화에 적합하지 않으며, 중형펌프의 경우 고압호스의 성능에 따라서 1000m이상의 거리에서도 사용이 가능할 것으로 사료된다.

  • PDF

소방관의 근골격계 증상과 직무 스트레스에 관한 연구 (The study for musculoskeletal symptoms and job stress in firemen)

  • 김정만;서병성;정갑열;김동일;김원술;조한석;김진욱;권재;윤동영;김정일;노영만
    • 한국산업보건학회지
    • /
    • 제17권2호
    • /
    • pp.111-119
    • /
    • 2007
  • Firemen are directly exposed to various harmful chemicals, physical factors and mental stress during rescue and fire-fighting. In fire extinguishing, unstable posture, poisonous gas, dust, high temperature and heavy equipments are possible hazardous factors. The alertness for emergency, shift work, job strain and stress are also possibly hazardous. Therefore, this study aimed to investigate the prevalence of musculo-skeletal symptoms and job stress and to determine risk factors in firemen. This study was carried out in a group of 226 firemen in Busan City, Korea. Standardized Nordic Questionnaire was used to investigate the prevalence of musculo-skeletal symptoms and Psycho-social Well-being Index (abbreviated PWI) was used to investigate the prevalence of job stress. General and occupational characteristics were included education, marital status, alcohol and smoking history, working duration, and work shift system. Body mass index (BMI) scores were calculated by physical examination including height and weight. Concerning musculo-skeletal complaints, the commonest site was neck, and shoulder, lower back, upper back were the next. Complaint site above one area of body was about 80%. From multiple logistic regression analysis, working duration was significant variable in musculo-skeletal symptoms. Odds ratio were 15.4 in working duration. About 16.8% was high risk stress group. From multiple logistic regression analysis, shift work and alcohol drinking were significant variables in PWI scores. Odds ratios were 2.25 in shift work. Accordingly, interventions are needed for health promotion of long term and shift worker.