• Title/Summary/Keyword: fire event

Search Result 342, Processing Time 0.032 seconds

A Study on the Prediction of City Gas Accident Damage by Consequence Analysis (Consequence Analysis를 통한 도시가스 사고 피해 예측에 관한 연구)

  • An, Jung-sik;Kim, Jihye;Yu, Jihoon;Kim, Jongkyoung;Kang, Subi;Cho, Donghyun
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.4
    • /
    • pp.36-40
    • /
    • 2022
  • Recently, the biggest topic in the industry is the area of industrial safety and health management. Since city gas is flammable gas and has a high risk of fire and explosion, much effort is required to prevent serious industrial and citizenry disasters. As part of city gas safety management, this study attempted to quantitatively predict the scope and degree of damage in the event of an explosion accident caused by city gas leakage through the Consequence Analysis. As a result, there was a difference in the accident result value according to various leakage conditions such as pressure and weather conditions. Through this study, a scenario of explosion due to city gas leakage will be prepared when performing city gas safety management work and used to prepare more effective accident prevention and emergency action plans.

Implementation of Public Address System Using Anchor Technology

  • Seungwon Lee;Soonchul Kwon;Seunghyun Lee
    • International journal of advanced smart convergence
    • /
    • v.12 no.3
    • /
    • pp.1-12
    • /
    • 2023
  • A public address (PA) system installed in a building is a system that delivers alerts, announcements, instructions, etc. in an emergency or disaster situation. As for the products used in PA systems, with the development of information and communication technology, PA products with various functions have been introduced to the market. PA systems recently launched in the market may be connected through a single network to enable efficient management and operation, or use voice recognition technology to deliver quick information in case of an emergency. In addition, a system capable of locating a user inside a building using a location-based service and guiding or responding to a safe area in the event of an emergency is being launched on the market. However, the new PA systems currently on the market add some functions to the existing PA system configuration to make system operation more convenient, but they do not change the complex PA system configuration to reduce facility costs, maintenance, and management costs. In this paper, we propose a novel PA system configuration for buildings using audio networks and control hierarchy over peer-to-peer (Anchor) technology based on audio over IP (AoIP), which simplifies the complex PA system configuration and enables convenient operation and management. As a result of the study, through the emergency signal processing algorithm, fire broadcasting was made possible according to the detection of the existence of a fire signal in the Anchor system. In addition, the control device of the PA system was replaced with software to reduce the equipment installation cost, and the PA system configuration was simplified. In the future, it is expected that the PA system using Anchor technology will become the standard for PA facilities.

A Survey of Medical Environments in Regional Public Hospitals Respond to Disasters (지역거점공공병원의 재난 대비 안전한 의료환경 실태조사 연구)

  • Lee, Hyunjin;Song, Sanghoon;Kim, Taeyun;Kim, Youngaee
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.30 no.2
    • /
    • pp.35-46
    • /
    • 2024
  • Purpose: It is the responsibility of public healthcare to respond quickly to infectious disease outbreaks and disasters such as MERS, COVID-19, the Syrian earthquake, and the Miryang Sejong Hospital fire accident. It is very important to secure safe medical facilities and protect lives through emergency medical support and disaster response systems. The purpose of this study is to investigate the safety status of regional medical facilities that play a central role in the event of a disaster. Methods: The target was 41 local public hospitals, including 35 regional medical centers and 6 Red Cross hospitals nationwide. We delivered a questionnaire to 41 medical facilities and collected data from 32 regional public hospitals that received responses. Results: In order to respond to safety accidents, a survey was conducted on infections, falls, patient identification, and incorrect connections for medical accidents, and for in-hospital accidents, a survey was conducted on entrapment, collision, water leaks, falling objects, and crime prevention. For natural disasters, we investigated the response environment for typhoons, floods, and snow damage, and for social disasters, we investigated the response environment for fire, power outages, and radiation damage. Implications: We hope that it will be used as basic data for developing standards and creating hospital facilities and environments that are safe for everyone to respond to various disasters and prevent patient safety accidents in the future.

Research on non-welding door frame assembly method that allows on-site assembly (현장조립이 가능한 무용접 도어프레임 조립방식에 대한 연구)

  • Lee, Joo-Won;Lim, Bo-Hyeok;Lee, Gwang-Woo;Lee, Hae-Yeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.155-156
    • /
    • 2023
  • In the case of steel door frames commonly found in general buildings, there are various assembly methods such as rivets, bolts, and welding, but the welding method is generally used. However, this welding joint method has many problems, such as distortion due to heat and damage due to external shock. In particular, when used as a fire door, problems may occur in the event of a fire due to distortion caused by heat from welding and the weak welded joint area. In the case of rivet or welded joints, when moved after assembly, joint loosening due to external shock may occur. Problems may arise where the bonding strength becomes weak. In addition, with the recent increase in high-rise buildings and larger buildings, when assembly is completed and brought to the site, a place is needed to store it, and in addition, there is a problem in that it has to be transported several times in small quantities to the installation site, which is another problem of time and cost loss. This is coming to the fore. In order to fundamentally solve this problem, we have researched and developed a non-welding door frame that can be assembled on site. We have researched and developed three assembly methods: screw-type, insert-type, and protrusion-type. Non-welded door frames are small in size and easy to package, making them advantageous for domestic and overseas exports.

  • PDF

Spatial Patterns and Temporal Variability of the Haines Index related to the Wildland Fire Growth Potential over the Korean Peninsula (한반도 산불 확장 잠재도와 관련된 Haines Index의 시.공간적 특징)

  • Choi Cwang-Yong;Kim Jun-Su;Won Myoung-Soo
    • Journal of the Korean Geographical Society
    • /
    • v.41 no.2 s.113
    • /
    • pp.168-187
    • /
    • 2006
  • Windy meteorological conditions and dried fire fuels due to higher atmospheric instability and dryness in the lower troposphere can exacerbate fire controls and result in more losses of forest resources and residential properties due to enhanced large wildland fires. Long-term (1979-2005) climatology of the Haines Index reconstructed in this study reveals that spatial patterns and intra-annual variability of the atmospheric instability and dryness in the lower troposphere affect the frequency of wildland fire incidences over the Korean Peninsula. Exponential regression models verify that daily high Haines Index and its monthly frequency has statistically significant correlations with the frequency of the wildland fire occurrences during the fire season (December-April) in South Korea. According to the climatic maps of the Haines Index created by the Geographic Information System (GIS) using the Digital Elevation Model (DEM), the lowlands below 500m from the mean sea level in the northwestern regions of the Korean Peninsula demonstrates the high frequency of the Haines Index equal to or greater than five in April and May. The annual frequency of the high Haines Index represents an increasing trend across the Korean Peninsula since the mid-1990s, particularly in Gyeongsangbuk-do and along the eastern coastal areas. The composite of synoptic weather maps at 500hPa for extreme events, in which the high Haines Index lasted for several days consecutively, illustrates that the cold low pressure system developed around the Sea of Okhotsk in the extreme event period enhances the pressure gradient and westerly wind speed over the Korean Peninsula. These results demonstrate the need for further consideration of the spatial-temporal characteristics of vertical atmospheric components, such as atmospheric instability and dryness, in the current Korean fire prediction system.

Development of the National Integrated Daily Weather Index (DWI) Model to Calculate Forest Fire Danger Rating in the Spring and Fall (봄철과 가을철의 기상에 의한 전국 통합 산불발생확률 모형 개발)

  • Won, Myoungsoo;Jang, Keunchang;Yoon, Sukhee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.4
    • /
    • pp.348-356
    • /
    • 2018
  • Most of fires were human-caused fires in Korea, but meteorological factors are also big contributors to fire behavior and its spread. Thus, meteorological factors as well as topographical and forest factors were considered in the fire danger rating systems. This study aims to develop an advanced national integrated daily weather index(DWI) using weather data in the spring and fall to support forest fire prevention strategy in South Korea. DWI represents the meteorological characteristics, such as humidity (relative and effective), temperature and wind speed, and we integrated nine logistic regression models of the past into one national model. One national integrated model of the spring and fall is respectively $[1+{\exp}\{-(2.706+(0.088^*T_{mean})-(0.055^*Rh)-(0.023^*Eh)-(0.014^*W_{mean}))\}^{-1}]^{-1}$, $[1+{\exp}\{-(1.099+(0.117^*T_{mean})-(0.069^*Rh)-(0.182^*W_{mean}))\}^{-1}]^{-1}$ and all weather variables significantly (p<0.01) affected the probability of forest fire occurrence in the overall regions. The accuracy of the model in the spring and fall is respectively 71.7% and 86.9%. One integrated national model showed 10% higher accuracy than nine logistic regression models when it is applied weather data with 66 random sampling in forest fire event days. These findings would be necessary for the policy makers in the Republic of Korea for the prevention of forest fires.

Explorative Study on Movement Patterns in Uljin-gun and Samcheok-si Wildfire Event (경북 울진·강원 삼척 등 산불에 따른 인구 이동 패턴에 대한 탐색적 연구)

  • Jeong, Ji Hye;Hwang, Woosuk;Pyo, Kyungsoo
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_3
    • /
    • pp.1805-1815
    • /
    • 2022
  • In 2022, wildfires broke out in Uljin-gun and Samcheok-si, which set the record for the longest forest fire in Korea, but there were no casualties. To protect local residents from wildfires, they must evacuate. Predicting the demand for evacuation in the event of wildfires is essential for the efficiency of disaster management. The purpose of this study is to analyze the human mobility patterns according to the occurrence of Uljin-gun and Samcheok-si wildfires. SKT floating population data was used in this study to analyze the human mobility patterns in Uljin-gun and Samcheok-si. The main findings are as follows. First, while the movement of the resident and visiting population decreased, the movement of the worker population was found to be similar to normal. Second, the resident population of Buk-myeon, Uljin-gun moved to the surrounding area to avoid the wildfires. Third, the region is an area judged to be safe from wildfires, and this mobility patterns are related to emergency disaster text messages. This study confirmed human mobility patterns of the population in the area where the wildfires through the floating population data, which is quantitative data. This suggests that it is important to guide residents to shelters through emergency text messages to minimize damage in the event of wildfires.

WSN Lifetime Analysis: Intelligent UAV and Arc Selection Algorithm for Energy Conservation in Isolated Wireless Sensor Networks

  • Perumal, P.Shunmuga;Uthariaraj, V.Rhymend;Christo, V.R.Elgin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.3
    • /
    • pp.901-920
    • /
    • 2015
  • Wireless Sensor Networks (WSNs) are widely used in geographically isolated applications like military border area monitoring, battle field surveillance, forest fire detection systems, etc. Uninterrupted power supply is not possible in isolated locations and hence sensor nodes live on their own battery power. Localization of sensor nodes in isolated locations is important to identify the location of event for further actions. Existing localization algorithms consume more energy at sensor nodes for computation and communication thereby reduce the lifetime of entire WSNs. Existing approaches also suffer with less localization coverage and localization accuracy. The objective of the proposed work is to increase the lifetime of WSNs while increasing the localization coverage and localization accuracy. A novel intelligent unmanned aerial vehicle anchor node (IUAN) is proposed to reduce the communication cost at sensor nodes during localization. Further, the localization computation cost is reduced at each sensor node by the proposed intelligent arc selection (IAS) algorithm. IUANs construct the location-distance messages (LDMs) for sensor nodes deployed in isolated locations and reach the Control Station (CS). Further, the CS aggregates the LDMs from different IUANs and computes the position of sensor nodes using IAS algorithm. The life time of WSN is analyzed in this paper to prove the efficiency of the proposed localization approach. The proposed localization approach considerably extends the lifetime of WSNs, localization coverage and localization accuracy in isolated environments.

A study on the economic analysis of the SL(Self Leveling) Inorganic Floor covering (SL 무기질 바닥재의 경제성 분석에 관한 연구)

  • Park, Ho-Geun;Hong, Seong-Wook;Yang, Je-Yong;Kim, Sang-Won;Shin, Chan-Ho;Choe, Min-Kwon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.105-109
    • /
    • 2011
  • This study is concerned with the development of the SL inorganic floor covering. First, volatile organic compounds, inorganic test profile on the SL through the flooring is environment-friendly inorganic noncombustible floor finishes the event of fire toxic gases (such as volatile organic compounds) emissions have been identified as not at all. Second, SL-breathable material, the concrete floor to prevent aging, long life, which are three levels of noise, shock-absorbing function was decreased. Third, SL economic analysis of mineral flooring terrazzo tile floors compared with the normal material. On a terrazzo tile cost 13,500 won ~ 24,500 won, but It have found that, in terms of labor SL 36,899 won ~ 38,899 won flooring mineral balance. Occurs in the total amount when compared with terrazzo tile floors and 25,399 won 3T, 5T and economical analysis concludes that the original 12,399 won.

  • PDF

Function Analysis for the active surveillance system of urban transit (도시철도의 능동적 감시체계를 위한 기능 분석)

  • An, Tae-Ki;Shin, Jeong-Ryul;Lee, Woo-Dong;Han, Seok-Yoon;Kim, Moon-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1027-1028
    • /
    • 2008
  • Most of the urban transit operation company in Korea have a passive surveillance system to monitor the status of the passengers and facilities in the urban transit service area. The surveillance system is based on CCTV, closed circuit television, and several sensors, such as a fire sensor. However, this system has some limitations to prevent and cope with the emergency quickly. So the urban transit operation companies have plans to be change their surveillance system to be active. The active surveillance system has an intelligent function to detect the event predefined by managers automatically. To construct the active surveillance system, there are a standard concept design and a function analysis. In this paper, we propose the classification of the functions of the active surveillance system for urban transit. We divide the functions into five parts, ordinary monitoring, safety monitoring, environment monitoring, administration support, and record management. And we describe the systems related to the every functions to clarify the classified functions.

  • PDF