• Title/Summary/Keyword: fire criteria

Search Result 295, Processing Time 0.083 seconds

A Study on an Improvement of the Fire-Protection System Category under the Enforcement of Housing Performance Rating System (주택 성능등급 표시제도 시행에 따른 소방시설 항목 개선에 관한 연구)

  • Lee, Su-Kyung;Lee, Dong-Yong;Hong, Dae-Hwa
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.126-132
    • /
    • 2010
  • The Housing Performance Rating System, enacted on 9 January 2006, an active measure containing provisions on improved quality and advanced performance of the Fire-Protection System for equalized ability to secure safety of life to some extent, is a desirable policy in fire-safety regard. The study of theoretical background of each performance rating section for the purpose of active and wide application of The Fire-Protection System category of the Housing Performance Rating System currently in effect internally. In accordance with the result of the study, the reform measures for the currently detailed evaluation criteria have been suggested to improve the performance of the Fire-Protection area of The Housing Performance Rating System currently being in force based on the assumption of prior settlement of the following; upward settlement of the point distribution standards on the performance ratings of each head backed up by an institutional Government policy with overriding priority; and urgently enacted Fire-Protection related laws and regulations.

Impact Assessment of the Damage by a Pool Fire in Yard Storage Facilities of a Container Terminal (컨테이너 터미널 옥외저장소에서의 액면화재에 대한 피해영향 평가)

  • Hwang, Man Woong;Lee, Ik Mo;Hwang, Yong Woo;Chun, Young Woo
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.33-42
    • /
    • 2016
  • Domestic harbor yard storage facilities are a place specifically located in a container terminal for import and export of packaged dangerous goods, and due to the recent relaxed criteria for the secured open area, concerns for the extended damage upon accidents are increasing. In this study, the impact of damages by radiant heat was analyzed through a simulation of a pool fire caused by the leakage of flammable liquids from a tank container. As a result, it was analyzed that the distance of radiant heat according to threshold damage levels was beyond the current criteria of the secured open area, and the structural damage of adjacent containers could happen within a very short time if they were exposed to the early pool fire continuously. It is considered that this study will be helpful in preparing the proper criteria for the secured open area between yard storage facilities in a container terminal.

A Study on Technical Trend of Fire Safety on Railway Vehicles for Launch CEN/TS 45545 (CEN/TS 45545 출범에 따른 철도차량 화재안전 기술 동향에 대한 연구)

  • Sung, Si-Young;Woo, Yee-Wan;Park, Jea-Hong
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1768-1773
    • /
    • 2010
  • CEN/TS 45545 is Europe consolidation standard for fire safety on railway behicles. This is based on the International Union of Railways(UIC) and different European countries. It is intended to protect passengers and staff in railway in the event of a fire on board. It will be prepared in 2012. Based on this consolidate standard, they are going to make single market, for raising technical competitiveness, technical innovation and globalization of that standard. For this reason, European academies, manufacturers, and sub-manufacturers confer and stady animated about CEN/TS 45545. In Korea, get out the safety assessment for ues incombustible interior material, the needs of quantitative analysis on fire protection, demand on recognition of fire protection scenario, and define about fire load analysis are becomin more and more important. Therefore, this paper will estimate and compare Flammability, Smoke Density, Toxicity Index( this is the key point for appraised fire safety performance of material) between CEN/TS45545 and fire standards on railway vehicle. Then suggest criteria for fire safety on railway vehicles.

  • PDF

Numerical analysis to determine fire suppression time for multiple water mist nozzles in a large fire test compartment

  • Ha, Gaghyeon;Shin, Weon Gyu;Lee, Jaiho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1157-1166
    • /
    • 2021
  • In this study, a numerical sensitivity analysis was performed to determine the fire suppression time for a large number of water mist nozzles in a large fire compartment. Fire simulations were performed using FDS (Fire dynamics simulator) 6.5.2 under the same condition as the test scenario 5 of the International Maritime Organization (IMO) 1165 test protocol. The sensitivities of input parameters including cell size, extinguishing coefficient (EC), droplets per second (DPS), and peak heat release rate (HRR) of fuel were investigated in terms of the normalized HRR and temperature distribution in the compartment. A new method of determining the fire suppression time using FDS simulation was developed, based on the concept of the cut-off time by cut-off value (COV) of the heat release rate per unit volume (HRRPUV) and the cooling time by the HRR cooling time criteria value (CTCV). In addition, a method was developed to determine the average EC value for the simulation input, using the cooling time and cut-off time.

Related Laws and Performance Criteria for Public Service Drones for Disaster Safety (재난안전드론 도입을 위한 법규 및 성능기준 기초연구)

  • Kim, Noh Joon;Lee, Sung Eun;Kim, Hwang Jin
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.150-155
    • /
    • 2016
  • This study is to suggest legislation and criteria for public service drones for disaster safety in order to enhance the research and development of the drones by helping setting right direction of the R&D. Many foreign governments are now conducting research and development on using drones as public service for disaster safety. Although there are also some efforts to using drones for public service in Korea, domestic laws and performance criteria for the drones for the purpose have not prepared yet. To set a right direction of the R&D, the laws and criteria shall be legislated and established immediately and then we can enhance the efforts to develop related technology for the drone. So this study proposed a performance criteria to fit various circumstances and situations by analyzing the aviation law in overseas. We hope this study can help R&D on the public service drones for disaster safety.

A study on the evaluation of fire safety according to the ventilation mode in a train fire at the subway platform (지하철 승강장에서 열차 화재시 제연모드에 따른 화재 안전성 평가 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.3
    • /
    • pp.293-310
    • /
    • 2020
  • The purpose of this study is to present the most effective smoke exhaust mode by comparing the quantitatively evaluated risks according to the smoke exhaust mode when a train fire occurs in a subway platform. Therefore, applying the typical subway platform as a model, train fire scenarios are developed with the evacuation start time and location of the fire train for each exhaust mode. The fire accident rates (F) are calculated and the number of fatalities (N) was quantitatively estimated by fire analysis and evacuation analysis for each scenario. In addition, the F/N curve compared with the social risk assessment criteria and the following conclusions were obtained. In the event of a train fire at the subway station platform, the evacuation must start up within 600 s in maximum to ensure the evacuees' safety. To secure evacuation safety, it is advantageous to operate the HVAC system of the platform in the air-supply mode at station without TVF. Comparing the F/N curve for each exhaust mode with the social risk criteria, it turned out that the risk significantly exceeds the social risk criteria in case of no mechanical ventilation. As a result, this paper shows that the ventilation mode in which TVF are exhausted and HVAC system is operated in the pressurized mode are the most effective smoke exhaust mode for ensuring evacuation safety.

Risk Acceptability and Criteria for multiple fatality in Urban disaster (도시재해의 위험성 수용한계와 위험성 범주의 선택)

  • 노삼규
    • Fire Science and Engineering
    • /
    • v.11 no.1
    • /
    • pp.11-19
    • /
    • 1997
  • The paper review of the methods used to present in a quantitative way of risk to the public in the vicinity of hazardous operation within urban area. The study concentrated on the calculation, presentation and interpretation of societal risk where multiple concerned population at large. It is also compared the way to use of risk criterias in various countries where the different population density concerned. It is recommended societal risk criteria need to be vastly apply to the exposed population.

  • PDF

An experimental study on the fireproof performance of fire damper in accordance with insulation conditions on the coaming and blade (코밍 방열 두께 및 블레이드 방열 유무에 따른 방화 댐퍼의 내화성능에 관한 실험적 연구)

  • Choi, Tai-Jin;Kim, Joung-Sik;Choi, Kyeong-Kwan;Lim, Young-Soo;Kim, You-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.431-437
    • /
    • 2013
  • In this paper, Fire resistance test was carried out to obtain class H-120 thermal insulation of fire dampers according to a hydrocarbon fire conditions. Specimens were fabricated three different types according to the change of the insulation system applied to damper blade and coaming which were measured surface temperature by performing the fire resistance test. As a test result, specimen-1, 2 of an uninsulated damper blade were exceeded thermal insulation acceptance criteria at 21 minutes, 46 minutes respectively, but specimen-3 of an insulated damper blade was satisfied thermal insulation acceptance criteria during 120 minutes. The test results showed that the insulation of the damper blade is an important factor in the fireproof performance of fire dampers concerning the coaming length minimum 500 mm on the unexposed side as specified test standard.

Analysis of the Sedimentation Status Test for Type-3 Dry Chemical Powder with Changes in Internal Pressure of the Dry Chemical Extinguisher (분말소화기의 내부압력 변화에 따른 제3종 분말소화약제의 침강도 시험)

  • Ju-Dal Son;Seo-Young Kim;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.1
    • /
    • pp.67-74
    • /
    • 2023
  • This study aims to measure sedimentation status change with the changes in internal pressure for dry chemical extinguishers of various use periods and analyze the suitability of the fire extinguishers' performance criteria. When the internal pressure of the fire extinguisher is 0%, 2 out of 10 new dry chemical powders for the 5 elapsed years were noted to be suitable, including 3 recycled dry chemical powders with 5 elapsed years that were found eligible. One out of 10 new dry chemical powders for 10 elapsed years was shown as suitable. Also, one new dry chemical powder for 13 elapsed years was suitable. When the internal pressure of the fire extinguisher was 50%, all 10 out of 10 new dry chemical powders for 5 years, recycled one with 5 elapsed years, and a new one with 10 elapsed years were found to be suitable, while 9 new dry chemical powders for 13 years were shown as suitable. When the internal pressure of the fire extinguisher was normal, new ones with 5 elapsed years, recycled ones with 5 elapsed years, new ones with 10 elapsed years, and new ones with 13 elapsed years were all 10 out of 10 samples noted as suitable. In summarizing the experiment results, it was found that the sedimentation status, one of the fire extinguisher's physical properties experiments, affects the fire extinguisher's performance criteria rather than the change with use periods.

Tests of Fire and Flame Retardant Performance for Membrane Materials (막재료의 난연 및 방염성능 실험에 대한 연구)

  • Kim, Gee-Cheol;Choi, Kwang-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.55-60
    • /
    • 2016
  • The Membrane structure has a number of problems in the application of a fireproof code based on general buildings codes. Thus, the fireproof code of membrane structure is necessary to activate the construction of the membrane structure. Because it requires a systematic classification of fire retardant and flame proof performance of membrane material. Fire retardant and flame proof tests are conducted on membrane materials mostly used in current construction to propose the fire and flame retardant performance criteria of membrane materials. Fire and flame retardant tests results, PTFE membrane material with the glass fiber fabric have a limit-combustible performance. PVDF membrane material with the polyester fabric does not ensure the fire retardant performance, but this membrane material has the flame retardant performance of a thick fabric. Also, ETFE does not ensure the fire retardant performance, but this membrane material has the flame retardant of a thin fabric.