• Title/Summary/Keyword: fire characteristic

Search Result 340, Processing Time 0.029 seconds

Thermal Characteristics of Foams and Discharge of Fire-Protection Foam Spray Nozzle (폼 분무 노즐 방사 분포 및 폼의 열적 특성 연구)

  • Kim, Hong-Sik;Kim, Youn-Jea
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.151-158
    • /
    • 2005
  • A characteristic of discharge for a foam spray nozzle with various parameters was investigated. The discharge patterns from a fire foam spray nozzle are important to evenly spray over a maximum possible floor area. Two parameters of a foam spray nozzle were chosen, and compared with those from the standard one. Also, in order to evaluate the performance of discharged foam agents used to protect structures from heat and fire damages, the thermal characteristics of fire-protection foams were experimentally investigated. A simple repeatable test for fire-protection foams subjected to fire radiation was developed. This test involves foam generation equipment, a fire source for heat generation, and data acquisition techniques. Results show that the bubble size of foam is increased by large inside diameter of orifice or closed air hole, but phenomenon of discharge angle and expansion ratio is opposite. For the case of the open air hole, liquid film of a circular cone discharges with formation, growth, split and fine grain. In case of the closed air hole, a pillar of foam solution discharges with that. Though the temperature gradient in the foam increases with increased foam expansion ratio. it is not change with increased intensity of heat flux.

Characteristic Analysis of Forest Fire Burned Area using GIS (GIS를 이용한 산불피해지역 특성분석)

  • Lee, Si-Young;Kang, Yong-Seok;An, Sang-Hyun;Oh, Jeong-Soo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.5 no.1
    • /
    • pp.20-26
    • /
    • 2002
  • The forest fire occurrences and burned area are increasing every year since 1990 in Korea, of which 65% is covered by forest. This study attempts to analyze topographic characteristics of forest fire burned area using GIS, and we also applied the statistical analysis based on the fire characteristics such as weather, forest as fuels and topography in small and large forest fire burned areas. The result of the statistical analysis shows that the size of forest fire was related to the slope length, slope degree, wind speed, forest type, and forest continuity.

  • PDF

A Study on Ship Evacuation Safety Consequent on the Size and Sort of Fire (화재의 크기와 종류에 따른 선박 피난 안전 연구)

  • KIM, Won-Ouk;KIM, Dae-Hee
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.5
    • /
    • pp.1358-1364
    • /
    • 2016
  • Maritime accidents caused by a ship include collisions, sinking, stranding and fire etc. This study is intending to consider fire accidents among such diverse marine accidents. It is much likely that various sorts of fires break out because crewmen are living in a narrow space for long periods of time consequent on the ship's characteristic of sailing on the sea. According to the ship fire survey, about 50% of the total fire accidents occurred at an engine room, and the main fire origin was analyzed to be oil. In addition, ship fire breaks out in the order of baggage racks and living quarter. In short, the survey indicates that all sorts of fires belonging to A, B, C and D-class have occurred. This study, targeting an actual passenger ship 'A', found the response time to evacuation, during which the people on board a ship recognize the outbreak of fire, and act, and the travel time for evacuation which is the actual travel time. In addition, this study carried out a simulation through the special program for fire analysis - FDS (Fire Dynamics Simulator) in order to find the effective evacuation time, i.e. life survival time. Particularly, this study did comparative analysis of the influence on the survival of passengers and crew based on the collected simulation data by fire size and sort. As a result of the analysis, it was found that when examining the only actual evacuation movement time excepting the response time to evacuation, people are safe by completing evacuation before the effective evacuation time only in case fire size is 100Kw among all sorts of fires. In other words, in case of the outbreak of fire more than 1 MW, it was found to fail to meet evacuation safety regardless of fire size.

A Study on Fire Hazard Analysis and Smoke Flowing for the Semiconductor Manufacturing Process (반도체 제조공정의 연기유동에 관한 연구)

  • Han, Soo-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.1
    • /
    • pp.197-211
    • /
    • 2007
  • The power of semiconductor, Korea is continuously constructing semiconductor production line for keeping a front-runner status. however, studies and data about potential risks in semiconductor factory are still short. If fire does not initially suppressed, the fire causes a great damage. To decrease fire risk factors, in addition to fire fighting safety equipment, more important thing is how to design and construct fire protection system. The current fire protection codes about semiconductor factory come under functional law, and this law is short of consideration about particularity of factory. The existing prescriptive fire codes depending on experience compose without evident engineering verifications, thus equipments which is created by the current prescriptive fire code may bring about a variety of problems. For example, the design under the current regulation can not cope with the excessive investments, low efficiencies, and the diversifying construction designs and be applied to the quick changes of new technologies. Ergo, an optimal design for fire protection is to equip fire protection arrangements with condition and environment of production field. Manufacturing factory of semiconductors is a windowless airtight space. And for cleanliness, there exists strong flow of cooperation. Therefore, there is a need for fire safety design that meets the characteristic of a clean room. Accordingly, we are to derive smoke flow according to cooperation process within a clean room and construction plan of an optimal sensor system. In this study, in order to confirm the performance of proposed smoke-exhaust equipment and suggest efficient smoke exhaust device when there is a fire of 1MW of methane in the clean room of company H, we have implemented fire simulation using fluid dynamics computation.

Effects of Characteristic Length Variation for Thrust Chamber on the Hot-fire Performance of Hydrazine Thruster (하이드라진 추력기의 추력실 특성길이 변화가 연소성능에 미치는 영향)

  • Kim, Jong Hyun;Jung, Hun;Kim, Jeong Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.2
    • /
    • pp.144-149
    • /
    • 2014
  • A ground firing test for hot-fire performance evaluation according to the characteristic length($L^*$) variation of thrust chamber was carried out for the hydrazine thruster which may be employed in space launch vehicles. A scrutiny into the performance characteristics of each thruster is made in terms of thrust, specific impulse, response characteristics, and characteristic velocity at steady-state firing mode with propellant inlet pressure of 2.41 MPa (350 psia). Through the test results, it has been verified that performance of characteristic velocity and specific impulse degrades as the characteristic length deviates from that of the standard model. Thus, it is confirmed that the thrust chamber configuration of standard model was suitably designed for the requirement specified.

Combustion Performance of a Pintle Injector Rocket Engine with Canted Slit Shape by Characteristic Length and Total Momentum Ratio (Canted Slit 형상의 핀틀 인젝터 로켓엔진의 특성길이와 운동량비에 따른 연소성능)

  • Yu, Isang;Kim, Sunhoon;Ko, Youngsung;Kim, Sunjin;Lee, Janghwan;Kim, Hyungmo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.1
    • /
    • pp.36-43
    • /
    • 2017
  • In this study, a pintle injector rocket engine which uses kerosene and liquid oxygen as propellants was manufactured by collecting basic design data and establishing a design procedure. Combustion performance of the liquid rocket engine was investigated by characteristic velocity efficiency with characteristic length of the combustion chamber and total momentum ratio. As a result of hot fire tests, it showed that the engine had shorter characteristic length comparing to those of other type injectors, which was known as recommended value with the propellant combination. Also, the characteristic velocity efficiency was greatly affected by total momentum ratio and almost constant within 1.0~1.5.

Fire Combustion Characteristics of Membrane Materials According to the Height and Heat Generation Rate (막재료의 설치높이와 발열량에 따른 화재연소특성)

  • Cho, Seung-Ho;Choi, Kwang-Ho;Roh, Young-Sook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.84-90
    • /
    • 2016
  • Various form of membrane structures are being built in recent years. However, there is no appropriate fire proofing standards which can be applied each specific membrane structures. Therefore, existing fire protection standards are in establishment state and they need to be revised. In the current study, commonly used membrane materials(ETFE, PVF, PTFE) has been selected to investigate its fire resistance behavior with the change of fire duration time. In addition to this, heat generation rate of the membrane materials in correlation with the height of membrane has been investigated. And these fire combustion characteristics of membrane materials can be used in future practice for the fire prevention regulations of membrane structures.

Mechanical Deterioration Characteristics of ACSR due to a Flame (화염으로 인한 ACSR의 기계적 열화 특성)

  • 박창기;이광식;강지원;김영달
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.160-168
    • /
    • 2003
  • In Korea, a large portion of aerial power-transmission cables is installed in the mountains. In the case of a fire in the mountains, steel wires coated with zinc and aluminum wires of those power cables exposed to the fire or near around will be deteriorated by the blaze and the high temperature. Deterioration proceeds by interactions of a variety of factors like quality, manufacturing process, the condition of installation and exposure environment of a wire, and so on. Generally, the characteristic of a conductor affect by a forest fire can not be analyzed without the effect through simulating a forest fire. However, there are little research accomplishments of that kind of simulation about it, and there's been no analysis of a sample exposed to an actual forest fire. This thesis shows the experimental results that apply to a new wire by an artificial flame-maker because it's difficult to directly analyze the characteristic of deterioration by a forest fire. Those results include the intensity of extension and wrench for a conductor. In addition, there's been an experiment and analysis about the mechanical characteristics of the wire of ACSR 480[$\textrm{mm}^2$] which was removed from Pohang area by a forest fire. Then, the database will be made to predict the state of deteriorated wires by a forest fire using those two data, and data necessary to diagnose the life state of an ACSR wire affected by a forest fire will be given.

Experiments for Combustion Analysis of Hybrid Motor (하이브리드 모터의 연소해석을 위한 실험연구)

  • 하윤호;장선용;이창진
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.262-265
    • /
    • 2003
  • This Study is focused on the instrumenting Hybrid Rocket Motor of ACPL at Konkuk University and researching combustion instability by measuring regression rate versus oxidizer mass flux. In the result of experiment, test fire was moderate and we could acquire data of pressure, thrust, and temperature of combustion chamber. In the future, studying unsteady change of regression rate and pressure characteristic analysis of combustion chamber through hundreds of experiments should be performed. furthermore, researching characteristic velocity by taking a measurement of combustion temperature will be inevitable.

  • PDF

A Study about Research on the Actual Condition for Fire Counterplan of Main Temple Wooden Cultural Properties (중요사찰목조문화재의 소방대책을 고려한 실태조사에 관한 연구)

  • Back, Min-Ho;Shin, Ho-Jun
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.121-130
    • /
    • 2009
  • This study is researched about the field trip of temples and the data for fire extinguishment manual of fire stations: it is done from June 2008 to December 2008 the 80 main temple wooden cultural properties among the 124 main wooden cultural properties appointed by the Cultural Heritage Administration. Cultural properties appointment classification, location classification, temple area, building area in a temple, building area of appointment cultural properties, a fire engine drive direction for fire suppression in a fire, distance from a fire station, and present condition of a fire administrator are researched. The cultural properties possess characteristic is in 2 cases: the whole things in a temple are appointed as cultural properties and only the wooden building is. The cultural properties are classified: the transport is possible or not. The special quality of cultural properties are classified for early correspondence and cultural properties transport in a fire and the basic data are arranged for damage limitation.