• Title/Summary/Keyword: finishing materials

Search Result 898, Processing Time 0.038 seconds

Analysis of the Types of External Wall and Roof Structure Layer Composition of CLT Building (CLT 건축물의 외벽 및 지붕 구조체 레이어 구성 유형 분석)

  • Yoo, Dong-Wan;Lee, Tae-Goo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.4
    • /
    • pp.71-78
    • /
    • 2020
  • Today, the whole world is going through a big chaos due to the COVID-19, but paradoxically, the emergence of COVID-19 has been leading to the need for sustainable development, such as Green New Deal that can improve global warming and carbon emissions, and the need for sustainable architecture is growing bigger and bigger in the architectural field as well. The level of CLT buildings in Korea is at a very rudimentary stage, while CLT buildings remedying existing wooden buildings are getting the spotlight among European countries for sustainable architecture. This study was conducted to categorize structure layer compositions of overseas CLT buildings and analyze architectural techniques and materials applied by collecting and analyzing information about CLT structure layer compositions of overseas CLT building-related institutions, companies and cases. When classifying structure layer compositions of foreign CLT buildings depending on the roles of layers. it was revealed that exterior wall structure layers were combined and organized within a sequence of external finishing, ventilation, waterproof, board, external insulation, airtightness, structure, airtightness, interior insulation, interior finishing, sloped roof structure layers were external finishing, ventilation, waterproof, board, external insulation, airtightness, structure, airtightness, interior insulation, interior finishing, flat roof structure layers were external finishing, ventilation, waterproof, planking wood, external insulation, waterproof, external insulation, airtightness, structure, airtightness, interior insulation, interior finishing.

A Study on the Remodeling of Apartment Housing Unit according to the Size - Focusing on the Data Analysis of Apartment Housing Unit Remodeling- (아파트의 규모에 따른 리모델링 실태 연구 - 아파트 주호의 개조자료 분석을 중심으로 -)

  • Shin Kyung-Joo;Lee Jee-Young;Jang Sang-Ock
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.6
    • /
    • pp.82-90
    • /
    • 2004
  • The purpose of this study is to investigate the remodeling of apartments housing unit according to the area type and size in order to provide useful information for future plans for more consumer-friendly dwelling units. To achieve this goal quantitative data analyses were employed. The sample was a total of 100 apartments analysed in previous researches conducting case studies on apartments remodeling. The data were analyzed by SPSS WIN program package in terms of frequency, percentage, and x2-test. The results of the study are as follows: The change of finishing materials were made in almost all of the sample. 6.4, 8.6 and 10.6 categories were altered in the small, medium, and large apartments respectively out of 21 remodeling categories. In the case of communal areas, change of finishing materials and installation, removal, and change of lighting fixtures were most frequent. The most frequent alteration in private areas was also observed In change of finishing materials and installation, removal and change of lighting fixtures.

Real Survey on Interior Surface Area and Applied Finishes in Recently-Planned Apartment Houses (공동주택의 실내부 표면적 및 사용 마감재 구성 실태분석)

  • Lee, Ji-Soon
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.115-121
    • /
    • 2010
  • This paper is an outgrowth of many years of practicing real interior work projects and one of my responses to the question not only about the actual dimension of interior work surface but also about the classification of contemporary finishing materials in basic interior project of high-rise apartment houses. For this purpose, 8 conventional apartment units which are already-built or designed have been surveyed and the results are interpreted in the form of proportion of space and finishes. The data can be applied to make up a schematic design in the selection of environment-friendly interior works and assessment of the degree of sustainability. For further study, the basic data provided here can be used as an index to differentiate the occupants' desire toward green interior design for their own apartment spaces, comparing to the conventional interior work in the Korean market. Not surprisingly, wall paper is dominated to make the interior surface in apartment houses. In the percentile of the utilization of finishing materials, wood-flooring and coating materials like wet paint also ranked at the upper position.

Theoretical Analysis on Heat Transfer Characteristics and Heat Flux Performance in Ondol Systems of Dried Type (건식온돌시스템의 전열특성 및 방열성능에 관한 이론적 분석)

  • Jang, Yong-Sung;Yu, Ki-Hyung;Cho, Dong-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.176-181
    • /
    • 2007
  • This study aims to evaluate theoretically heat transfer characteristics and heat flux performance in ondol system of dried type is composed of panel of ceramics to improve of thermal conductivity and fin to expand heat. To this end, we analyzed effect of design factors(temperature of hot water, set temperature of room and thermal conductivity of finishing materials) in ondol system of dried type by heat transfer analysis. The main results of this study are summarized as follows; The deviation of heat flux and temperature was reduced by heat expansion from fin decreasing heat loss generated in air layer. The temperature and heat flux in upper finishing materials surface linearly increased according to temperature increment of hot water, but the temperature distribution in upper surface was assessed uneven. The greater heat resistance value of upper finishing materials, the deviation of maximum temperature and minimum temperature was decreased. Also, we suggested a basic design data about ondol system of dried type through an analysis of simulation results on heat transfer characteristics and heat flux performance.

  • PDF

Dual-curable Flame-Retardant Finish of Silk Fabrics Using a Water-soluble Cyclophosphazene Derivative (수용성 Cyclcophosphazene 유도체를 이용한 견섬유의 이중경화형 방염가공)

  • Kim, Jeong-Hwan;Baek, Ji-Yun;Jang, Jinho
    • Textile Coloration and Finishing
    • /
    • v.34 no.4
    • /
    • pp.217-223
    • /
    • 2022
  • Flame-retardant finished silk fabrics could release carcinogenic formaldehyde resulting from the conventional finishing agents. New water-soluble cyclophosphazene derivative can be used as a formaldehyde-free flame retardant for the silk protein. Dichloro tetrakis{N-[3-dimethylamino)propyl]methacrylamido}cyclophosphazene(DCTDCP) can be cured by heat or UV irradiation as a durable flame retardant for the silk fabrics. Treatment conditions were optimized including curing temperature and time, finishing formulations, and UV energy. At the 30% DCTDCP application, peak HRR and THR decreased by 42.6% and 49.6% respectively compared to the pristine silk fabrics. Also char residue increased up to 48% from 11% indicating solid-phase retarding mechanism. The flame-retardant silk fabrics showed a LOI of 31.1 and the washed sample maintained a LOI of 26.8 even after ten laundering cycles.

A study on the Probabilistic Carbonation Progress for Existing RC Structure Apartment by Surface Finishing Materials (표면 마감재를 시공한 RC조 아파트의 확률론적 탄산화 평가 연구)

  • Lee, Hyung-Min;Min, Sang-Ho;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.7-8
    • /
    • 2017
  • As the importance of maintenance of reinforced concrete structure recently has emerged, the attention of durability of structure has been increasing. There are many studies about durability decline especially due to the carbonation. In order to study carbonation progress after surface repair of carbonated concrete, each carbonation penetration velocity from different repair materials of concrete structure is compared through the experiment of carbonation accelerating CO2 concentration to 5%. As carbonation infiltration progress is predicted through this study, the counterplan of service life evaluation will be prepared on selection of repair materials of concrete structure.

  • PDF

Influence of Surface Finishing Material Types to Formaldehyde and Volatile Organic Compounds Emission from Plywood

  • Kim, Ki-Wook;Oh, Jin-Kyoung;Lee, Byoung-Ho;Kim, Hyun-Joong;Lee, Young-Kyu;Kim, Sung-Hun;Kim, Gwan-Eui
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.39-45
    • /
    • 2008
  • Formaldehyde and volatile organic compounds (VOCs) are emitted from wood-based panels that have been made using wood particles, wood fiber, wood chips, formaldehyde-based resins and so on. In this study, we examined formaldehyde and total VOCs (TVOC) emission behaviors for plywood overlaid with water-soluble phenolic resin impregnated linerboard (PL), and two kinds of surface materials (decorative veneer and pre-impregnated finishing foil) that were adhered onto the PL that named DPL and PPL. EVA (ethyl vinyl acetate) was used to overlay the decorative veneer and pre-impregnated finishing foil on the plywood with water-soluble phenolic resin impregnated linerboard by a hot press instrument. The debonding test and accelerated aging test were conducted to assess their mechanical properties. Formaldehyde and TVOC emission concentrations were measured using the FLEC method and a VOC Analyzer, respectively. The debonding test results of PL, DPL and PPL were 1.2, 1.5, and $0.5N/mm^2$, respectively. The surface appearance of the samples were not changed after the accelerated aging test. The PL and DPL exhibited reduced formaldehyde and TVOC emission levels, respectively. In the case of PPL, the VOC value was relatively higher than those of PL and DPL.

Analysis of Heat Transfer Characteristics by Materials in Closed Conditions Using Acrylic Hemisphere (I): Comparison of Interior Finishing Materials (아크릴 반구를 이용한 밀폐 조건에 따른 재료별 열 이동 특성 분석(I): 실내마감재 종류에 따른 비교)

  • YANG, Seung Min;LEE, Hyun Jae;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.2
    • /
    • pp.217-230
    • /
    • 2020
  • Global warming has increased interest in reducing greenhouse gas emissions. And a policy has effort to reduce energy consumption as a greenhouse gas reduction plan. In Korea, 25% of total energy is consumed in the building sector. In order to reduce energy consumption of buildings, it is possible to expand the utilization of wood as a structural material or thermal insulation materials with low thermal conductivity. It is also reported that when used as an interior finishing material, the energy consumption of the building is reduced by up to 7% by insulation performance. In this study, the heat transfer characteristics and the heat capacity were compared according to the three type of finishing materials(cement, paulownia coreana, medium density fiberboard) normally used as indoor finish materials. Through this study, most of the heat transfer volumes are transferred in the form of radiant heat, and the result was derived from the highest amount of energy and heat transfer in the use of paulownia coreana. When indoor finishing materials are used as wood, it is deemed that energy efficiency inside the building will be improved.

Human Risk Assessment for Exposure to Heavy Metals within Finishing Materials of Playground Facilities for Children in Gwangju (광주지역 어린이 놀이시설 마감재의 중금속 노출에 의한 인체 위해성평가)

  • Sang-Hoon Yoon;So-Young Kim;Eun Cho;Tae-Hui Nam;Jin-Hwan Park;Hwa-Jin Kong;Ki-Won Lee;Gwang-Yeob Seo;Jeong-Hun Park;Kyoung-Woo Min
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.2
    • /
    • pp.146-156
    • /
    • 2024
  • Background: Children who use playground facilities are exposed to potential risks due to the high concentration of heavy metals contained in the finishing materials of facilities in children's playgrounds. Objectives: The purpose of this study was to investigate the concentration of heavy metals in the finishing materials of outdoor children's playgrounds where harmful heavy metals exist in Gwangju and to conduct human risk assessment for children and adults by age to find the risks and limitations. Methods: The bottom and top layers of double-painted paint were peeled off and collected together from the finishing materials of children's play facilities such as slides, swings, and seesaws in 147 children's parks in Gwangju. Heavy metals were analyzed using ICP-OES, etc., and human risk assessment was performed using the concentrations of heavy metals. Results: Based on 1.0E-04, which requires legal regulation, CTE was found to pose a carcinogenic risk for preschool children and no carcinogenic risk for the rest of the age groups. However, RME showed that both men and women of all ages had a carcinogenic risk. For reference, when the carcinogenic risk was based on 1.0E-06, CTE was found to pose a carcinogenic risk from infants to elementary school students, and RME was found to have a carcinogenic risk in all age groups. It was judged that there is a non-carcinogenic risk if the non-carcinogenic risk exceeds 1 based on the hazard index (HI) 1. In CTE, there was no non-carcinogenic risk, and RME for preschooler males (1.49E+00) and females (1.56E+00) were found to have non-carcinogenic risk. Conclusions: This study was meaningful in that it examines the differences in the current management of heavy metals concentration standards and potential carcinogenic and non-carcinogenic risks to the human body and discusses the relationship between heavy metals and human health effects.