• 제목/요약/키워드: filtration performance

검색결과 375건 처리시간 0.02초

여과형 비점오염 처리장치의 오염물질 제거특성 및 역세척 분석 (The Performance of Pollutant Removal Using Nonpoint Treatment Filtration Device and Analysis of the Filter Backwashing Effect)

  • 이준호;양승호;방기웅
    • 한국물환경학회지
    • /
    • 제31권5호
    • /
    • pp.523-532
    • /
    • 2015
  • Hydrocyclone is widely used in industry, for its simple design, high capacity, low maintenance and low operational cost. The objective of this study is to develop hydrocyclone coagulation and filtration system. The system is made of hydrocyclone ballasted coagulation with polyaluminium chloride silicate (PACS) and upflow filter to treat micro particles in urban storm runoff. Roadside sediment particles (< $200{\mu}m$) was mixed with tap water to make various turbid suspensions to simulate urban storm runoff. The filter cartridge was filled with polyethylene media system and ran 1hr per everyday and total operation time were 8.19hrs and backwashing everyday after end of operation. The operation condition of flowrate was $8.2{\sim}11.9m^3/day$ (mean $10.1m^3/day$) and surface overflow rate (SOR) based on filter surface area was $45.5{\sim}65.9m^3/m^2/day$ (mean $55.7m^3/m^2/day$). The range of PACS dosage concentration was 14.0~31.5 mg/L. As the results of operation, the range of removal efficiency of turbidity, SS were 81.0~95.8% (mean 89.5%) 81.8~99.0% (mean 91.4%), respectively. An increase of filtration basin retention time brought on increased of removal efficiency of turbidity and SS, and increase of SOR brought on decreased of removal efficiency. During the first flush in urban area, storm runoff have an high concentration of SS (200~600 mg/L) and the filtration bed becomes clogged and decreased of removal efficiency. Backwashing begins when the drainage pipe valve at the filtration tank bottom is completely open (backwashing stage 1). Backwashing stage 2 was using air bubbles and water jet washing the media for 5 mins and open the drainage valve. After backwashing stage 1, 2, 61.83~64.04%, 18.53~27.51% of SS loading was discharged from filtration tank, respectively. Discharged SS loading from effluent was 7.12~14.79% and the range of residual SS loading in fliter was 2.26~5.00%. The backwashing effects for turbidity, SS were 89.5%, 91.4%, respectively. The hydrocyclone coagulation and filtration with backwashing system, which came out to solve the problems of the costly exchange filter media, and low efficiency of removing micro particles of filter type nonpoint treatment devices, is considered as an alternative system.

홍수터여과에서 집수관의 최적설계 연구 (A Study on the Optimum Design of Horizontal Collectors in Floodplain Filtration)

  • 피성민;김승현
    • 대한환경공학회지
    • /
    • 제34권6호
    • /
    • pp.430-437
    • /
    • 2012
  • 홍수터여과에서 집수관의 설계에 대한 자료를 얻기 위해 실험실 규모의 모래통 실험을 수행하였으며, 집수관의 직경, 모래의 투수계수, 집수정의 수위 그리고 지표에서의 원수공급률 등의 변화에 따른 집수관에서의 수두분포와 지하수면 분포를 측정하였다. 측정결과를 수치해석코드에 적용하여 집수관 각 부위에서의 여과수 유입률도 파악하였다. 이들 자료로부터 홍수터여과에서 집수정의 운영수위를 낮춤으로 인한 부작용은 없을 것으로 예상되었으며, 적절한 회수능력에 비해 원수공급률이 큰 경우 대수층에서의 수평방향의 흐름이 발달하여 수평집수관의 통수능 부족을 보완함을 알 수 있었다. 이 경우 여과수의 토양중 이동거리가 늘어나므로 여과수의 수질개선에도 도움이 될 것으로 판단되었고, 따라서 홍수터여과에서는 강변/하상여과에서보다 더 작은 직경의 수평집수관을 사용할 수 있음을 알 수 있었다. 전체 수두손실중 수평집수관에서의 수두손실이 차지하는 비율이 수평집수관 출구유속과 비례함을 알 수 있었으며, 이를 이용하면 홍수터여과에서 수평집수관의 설계와 평가가 가능할 것으로 판단되었다.

활성슬러지조내 부직포 여재 관형필터의 고액분리 특성 평가 (Evaluation of Tubular Type Non-woven Fabric Filter for Solid-liquid Separation in Activated Sludge Reactor)

  • 서규태;이택순;박영미
    • 대한환경공학회지
    • /
    • 제30권2호
    • /
    • pp.234-238
    • /
    • 2008
  • 활성슬러지 공정에 막을 침지한 MBR(Membrane Bioreactor)공정에서 고가의 막을 대체하여 부직포 같은 섬유 여과막을 이용한 연구가 수행되었다. 부직포는 저렴한 가격, 저압에서 높은 투과유속의 확보 등 막을 대체할 수 있는 대안으로서 가치가 높다. 그러나 부직포 여과막 모듈은 막에 비하여 비표면적이 현저하게 작기 때문에 이를 증가시키는 노력이 필요하다. 본 연구에서는 활성슬러지 공정에 부직포 여과 관형 막모듈을 침지하여 설치형태와 관직경에 따라 여과압력에 미치는 영향을 실험적으로 검토하였다. 관형 필터의 직경이 같을 때, 반응조내 필터 모듈의 설치형태가 여과압력 변화에 미치는 영향은 없었다. 그러나 필터의 관 직경이 작을수록 여과압력의 상승이 빠르게 나타났고 이는 관내 수리학적 손실에 기인된 것으로 해석되었다. 따라서 관형 부직포 여과막은 관경 10 mm 이상에서 비표면적을 고려하여 설계하고, 반응조내 수직형으로 설치함이 적정한 것으로 나타났다.

모듈형 이동식 물생산 시스템 운전 성능 및 자연 유기물 제거 거동 평가 (Evaluation of the performance and the removal characteristics of natural organic matter in a modular mobile water production system)

  • 황유훈;양필제;송지민;홍민지;최창형;고석오;김도군
    • 상하수도학회지
    • /
    • 제32권1호
    • /
    • pp.55-65
    • /
    • 2018
  • It is necessary to develop a mobile water production system in order to provide stable water supply in case of disasters such as floods or earthquakes. In this study, we developed a modular mobile water production system capable of producing water for various uses such as domestic water and drinking water while improving applicability in various raw water sources. The water production system consists of three stages of filtration (sand filtration - activated carbon filtration - pressure filtration) to produce domestic water and an additional reverse osmosis process to produce drinking water. In laboratory and field experiments, the domestic water production system showed excellent treatment efficiency for particulate matter, but showed limitations in the treatment of dissolved substances such as dissolved organic matter. In addition, ultraviolet irradiation was considered as additional disinfection step, because it does not form precipitates of manganese oxides after disinfection. Reverse osmosis process was added to increase the removal efficiency of dissolved substances and the treated water satisfied drinking water quality standards. Fluorescence analysis of dissolved organic matter showed that the fulvic acid-like substances in raw water was successfully removed in the reverse osmosis process. The mobile water production system developed in this study is expected to be used not only in water supply in case of disaster, but also widely used in islands and rural area.

Optimization and Validation of a Virus Filtration Process for Efficient Removal of Viruses from Urokinase Solution Prepared from Human Urine

  • Kim, In-Seop;Choi, Yong-Woon;Lee, Sung-Rae
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권1호
    • /
    • pp.140-147
    • /
    • 2004
  • Urokinase is an enzyme with fibrinolytic activity (plasminogen activator) isolated from fresh urine of healthy men. Viral safety is an important prerequisite for clinical preparation of the protein from urine. In order to increase the viral safety of a high purity urokinase in regard to non-enveloped viruses, a virus removal process using a novel polyvinylidene fluoride membrane filter (Viresolve NFP) has been optimized. Urokinase was able to pass through the filter with recoveries of 95% in the production scale process. No substantial changes were observed in physical and biochemical characteristics of the filtered urokinase in comparison with those of the enzyme before filtration. A 47-mm disk membrane filter was used to simulate the process performance of the production scale cartridges and tested if it could remove several experimental model viruses for human pathogenic viruses, including porcine parvovirus (PPV), human hepatitis A virus (HAV), murine encephalomyocarditis virus (EMCV), bovine viral diarrhoea virus (BVDV), and bovine herpes virus (BHV). Non-enveloped viruses (PPV, HAV, and EMCV) as well as enveloped viruses (BVDV and BHV) were completely removed during filtration. The log reduction factors achieved were $\geq$4.86 for PPV, $\geq$4.60 for HAV, $\geq$6.87 for EMCV, $\geq$4.60 for BVDV, and $\geq$5.44 for BHV. These results indicate that the virus filtration process successfully improved the viral safety of the final products.

Improvement of Virus Safety of an Antihemophilc Factor IX by Virus Filtration Process

  • Kim, In-Seop;Choi, Yong-Woon;Kang, Yong;Sung, Hark-Mo;Sohn, Ki-Whan;Kim, Yong-Sung
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권7호
    • /
    • pp.1317-1325
    • /
    • 2008
  • Viral safety is an important prerequisite for clinical preparations of plasma-derived pharmaceuticals. One potential way to increase the safety of therapeutic biological products is the use of a virus-retentive filter. In order to increase the viral safety of human antihemophilic factor IX, particularly in regard to non-enveloped viruses, a virus removal process using a polyvinylidene fluoride membrane filter (Viresolve NFP) has been optimized. The most critical factor affecting the filtration efficiency was operating pH and the optimum pH was 6 or 7. Flow rate increased with increasing operating pressure and temperature. Recovery yield in the optimized production-scale process was 96%. No substantial changes were observed in the physical and biochemical characteristics of the filtered factor IX in comparison with those before filtration. A 47-mm disk membrane filter was used to simulate the process performance of the production-scale cartridges and to test if it could remove several experimental model viruses for human pathogenic viruses, including human hepatitis A virus (HAV), porcine parvovirus (PPV), murine encephalomyocarditis virus (EMCV), human immunodeficiency virus type 1 (HIV), bovine viral diarrhea virus (BVDV), and bovine herpes virus (BHV). Non-enveloped viruses (HAV, PPV, and EMCV) as well as enveloped viruses (HIV, BVDV, and BHV) were completely removed during filtration. The log reduction factors achieved were $\geq$6.12 for HAV, $\geq$4.28 for PPV, $\geq$5.33 for EMCV, $\geq$5.51 for HIV, $\geq$5.17 for BVDV, and $\geq$5.75 for BHV. These results indicate that the virus filtration process successfully improved the viral safety of factor IX.

침지형 막결합 연속회분식 반응기의 운전에서 폐수의 도입단계가 제거효율과 여과성능에 미치는 영향 (The Effect of Filling Step on the Removal Efficiency and Filtration Performance in the Operation of Submerged Membrane-Coupled Sequencing Batch Reactor)

  • 김승건;이호원;강영주
    • 멤브레인
    • /
    • 제21권3호
    • /
    • pp.263-269
    • /
    • 2011
  • 침지식 막결합형 연속회분식 생물반응기에서 폐수의 도입단계가 제거효율과 여과성능에 미치는 영향을 조사하였다. 호기성 단계의 초기에 공급할 경우(Mode-1)와 무산소 단계의 초기에 공급할 경우(Mode-2)에 대하여 89일 동안 동시에 운전하였다. COD 제거효율과 여과성능은 2가지 운전방식 간에 큰 차이가 없었다. 그러나 영양염류(총질소와 총인)의 제거효율에 있어서 Mode-2가 Mode-1에 비해 보다 효과적이었다. Mode-2의 경우 COD, 총질소 및 총인의 제거율은 각각 99.1, 73.3 및 77.7%이었다.

주기적인 약품역세를 적용한 침지형 MBR 시스템의 운전성능에 관한 연구 (Operational Performance of Submerged Membrane Bioreactor Combined with Periodic Chemical Backwash)

  • 김관엽;이의종;송준섭;김지훈;김형수
    • 상하수도학회지
    • /
    • 제22권1호
    • /
    • pp.87-92
    • /
    • 2008
  • Purposes of this study were to evaluate operational performance of submerged membrane bioreactor (MBR) combined with periodic chemical backwash. Five lab-scale submerged MBRs were performed in accordance with NaOH dose, backwash solution volume. While filtration resistance of MBR system without backwash (Control) was increased persistently from startup, those of four MBR systems (RUN 1-4) with chemical backwash were maintained at $(1.4{\pm}0.16){\times}10^{12}$, $(8.6{\pm}0.90){\times}10^{11}$, $(1.9{\pm}0.10){\times}10^{12}$, $(1.4{\pm}0.10){\times}10^{12}l/m$, respectively. Under chemical backwash condition of 0.0230 M, 375 mL, permeability of membrane was highest at flux of $30L/m^2/hr$. According to results from experiment that changing condition of dose and volume, it was estimated that effect of chemical dose acts more greatly than backwash solution volume. Because COD removal rates of all MBR systems with chemical backwash were more than 96%, it was proved that NaOH added to backwash solution did not affect microorganism.

평막을 이용한 침지형 막여과시스템에서 고농도 분말활성탄 주입에 의한 수처리성능 개선 효과 (The Effects of PAC (Powdered Activated Carbon) on Water Treatment Performance of an Immersed Membrane System Using Flat-sheet Membrane Module)

  • 가이샹쥐안;김한승
    • 상하수도학회지
    • /
    • 제21권2호
    • /
    • pp.195-201
    • /
    • 2007
  • A submerged flat-sheet membrane separation system integrated with PAC (powdered activated carbon) was used in this research in order to investigate the effects of PAC on the efficiencies of operation and treatment and to evaluate the performance of the system. The experiments were carried out under operating conditions of a filtration rate of 0.38 m/d, water temperature of $20-28^{\circ}C$, and PAC dose of 0 g/L (Run-A) and 20 g/L (Run-B). The influent concentrations of TOC (total organic carbon), $NH_4{^+}-N$ (ammonia nitrogen) and $UV_{254}$ (UV absorbance at 254 nm) were 2.48 mg/L, 1.4 mg/L and 2.53 1/m, respectively. TOC removal of 43.2 and 73.6%, ammonia nitrogen removal of 4.9 and 15.9%, and $UV_{254}$ removal of 20.6 and 31.6% were obtained for Run-A and Run-B, respectively. During an experimental period of 33 days, no change was found in TMP (Run-B), but the TMP in Run-A increased by 5 kPa after 29 days. This research showed that the filtrate quality and the performance efficiency were enhanced when PAC was introduced into the filtration system.

다목적 여과저류지에서의 하상여과용 인공하천 설계연구 (A Study on the Design of Artificial Stream for Riverbed Filtration in Multi-purpose Filtration Pond)

  • 손동훈;박재영;김승현
    • 대한환경공학회지
    • /
    • 제33권7호
    • /
    • pp.536-543
    • /
    • 2011
  • 다목적 여과저류지에 하상여과를 적용하기 위한 인공하천의 최적설계를 찾기 위해서 하천수의 에너지경사와 Manning의 평균유속공식을 이용하여 물 흐름에 대한 수학적 모델을 수립하였고, Euler의 방법을 이용한 수치해법으로 해석하였다. 모델을 이용하여 다양한 시나리오에 대한 모사를 수행함으로써 하상여과용 인공하천의 여러 설계요소를 검토하였다. 검토결과 면적이 100 ha인 강변저류지의 경우, 인공하천의 종단경사는 2/10,000, 하상에서의 침투율은 $2.5m^3/m^2-day$가 적당한 것을 알 수 있었다. 이 경우 수심은 1 m 이내이고 하상에서의 Manning의 조도계수는 0.026 정도로 예측되었으며, 인공하천의 길이가 길수록 유리함을 알 수 있었다. 한편, 인공하천에 빠른 유속을 발생시킴으로써 하상여과에 수반하는 하상의 폐색을 방지하는 방법은 효율적이지 않음을 알 수 있었고, 낙차가 큰 보의 주변에서 본 설비의 효율이 더 좋아짐을 알 수 있었다.