• Title/Summary/Keyword: filtration performance

Search Result 375, Processing Time 0.028 seconds

Treatment of Phosphorus and Suspended Solid in Reject Water of Sewage Using an Integrated Slow Mixing/Sedimentation and Net Fit Fiber Filtration System (일체형 완속교반/침전 그물망 압착식 섬유여과장치를 이용한 하수처리장 반류수 내 고농도 인 및 부유물질 처리)

  • Kim, Jeongsook;Kim, Min-Ho;Kim, Mi-Ran;Jang, Jeong-Gook
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.816-821
    • /
    • 2017
  • An integrated slow mixing/sedimentation and net fit fiber filtration system has been developed to reduce the high concentrations of suspended solid (SS) and total phosphorus (T-P) in the reject water from sewage/wastewater. A filtration device used in this experiment consists of coagulation, in-line mixing, air injection, slow mixing/sedimentation, and filtration processes. The performance test using this device was carried out with six operational modes for reject water from sewage treatment plant. Experimental conditions used were 16.7, 33.3, 41.7 and 50.0 ton/day of flow rate and 2~4 of Al/P molar ratio. By injection of coagulant in each operational mode, the high removal efficiencies of SS and T-P were obtained, but continuous operation time was decreased to 7.8~11.4 min in most modes. However, when the Mode 5 of the developed filtration device was applied, the continuous operation time was maintained up to 88.2 min. Also, it was found that the continuous operation time in the Mode 5 using the developed system was increased from 8 to 11.3 times longer than those in other modes. Backwashing flow rate was also very low at 5.4% of total filtered water. Therefore, it can be concluded that the Mode 5 of the developed filtration system was the most efficient treatment method for the removal of high concentrations of SS and T-P.

The Effect of Coagulant on Filtration Performance in Submerged MBR System (침지형 MBR 공정에서 응집제가 여과성능에 미치는 영향)

  • Kim Kwan-Yeop;Kim Ji-Hoon;Kim Young-Hoon;Kim Hyung-Soo
    • Membrane Journal
    • /
    • v.16 no.3
    • /
    • pp.182-187
    • /
    • 2006
  • The purpose of this study was to investigate effect of coagulation on filtration performance of membrane in submerged MBR system and influence of continuous aeration to reduce fouling of membrane surface on coagulated floc. For this purpose, aeration tank sludge of MBR system was compared with jar-test sludge. The experimental results were analysed in terms of floc size and SRF (Specific resistance of Filtration). The more alum was added, the more content of floc below $10{\mu}m$ reduced and SRF decreased. But compared with jar-test results, it was found that effect of coagulation on MBR floc was reduced. Operation time of membrane in alum added MBR was longer than that in control MBR. But operation time was not proportional to alum dose. It was thought that the result was reason that floc below $10{\mu}m$ was not reduced sufficiently by shear force of continuous aeration. Moreover it was founded that if alum is added more than proper dose, it brings filtration resistance to increase.

Industrial dairy wastewater purification by shear-enhanced membrane filtration: The effects of vibration

  • Kertesz, Szabolcs
    • Membrane and Water Treatment
    • /
    • v.5 no.2
    • /
    • pp.73-86
    • /
    • 2014
  • Membrane fouling is a major challenge limiting the use of membrane applications. In this study high induced shear rates were utilized at the membrane surface in order to reduce the organic and inorganic scaling by using the torsional vibration of flat sheet membranes. The performances of a vibratory shear-enhanced processing (VSEP) system for the ultrafiltration (UF), nanofiltration (NF) and reverse osmosis (RO) membrane filtration of industrial dairy wastewater were investigated. The vibration and non-vibration methods were compared with the same membrane and operational parameters during the purification of real dairy industrial process wastewater. In the initial experiments, short-term tests were carried out in which the effects of vibration amplitude, recirculation flow rate and transmembrane pressure were measured and compared. The permeate flux, turbidity, conductivity and chemical oxygen demand (COD) reduction of dairy wastewater were investigated by using UF, NF and RO membranes with vibration and non-vibration methods. In the subsequent experiments, concentration tests were also carried out. Finally, scanning electron microscopy (SEM) revealed that the vibration method gave a better performance, which can be attributed to the higher membrane shear rate, which reduces the concentration of solids at the membrane, and the transmission.

Study on Electrospun Activated Carbon Mats for the Filtration of Particulate Matter and Volatile Organic Compound in the Air (공기 중 미세먼지와 휘발성유기화합물 제거를 위한 활성탄 전기방사 필터 연구)

  • Han, Sangil
    • Korean Chemical Engineering Research
    • /
    • v.56 no.3
    • /
    • pp.356-360
    • /
    • 2018
  • The negative effects on ecosystem are getting serious due to the increase of particulate matters (PM) in the air by the increase of the number of population and the industrial activities. Thus, there have been a lot of environmental policies and researches of air purification system and filter mask to relieve the environmental problem. In this research, activated carbon impregnated cellulose acetate fiber filters produced using an electrospinning technique are studied for air purification. NaCl aqueous solution was used to generate PM and the humid air with NaCl PM was dried using a dehumidifier for the filter performance test. Filtration efficiency was increased with the increase of activated carbons, and acetone adsorption capacity was enhanced.

Development and Performance Evaluation of Electrodewatering System for Sewage Sludge Recycling

  • Lee, Jae-Keun;Lee, Jung-Eun;Shin, Hee-Soo;Park, Chan-Jung;Lee, Chang-Gun;Kim, Young-Hwan;Kim, Man-Jong
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.443-447
    • /
    • 2001
  • A laboratory-scale electrodewatering system for enhancing conventional filter pressure dewatering by an electric field has been developed to decrease the water content of sludge generated in the wastewater treatment. It consists of a piston-typed filter press, a power supply and data acquisition system. The offset of electrodewatering is investigated as a function of applied pressure, applied voltage, sludge type and filtration time. Also the optimal conditions for maximizing the dewatering efficiency in the eletrodewatering system are investigated. Electric field strength and mechanical pressure are in the range of from 0 to 120 V/cm and from 98.1 to 392.4 kPa. The dewatering rates increased with increasing electric strength. These experiments produced a final sludge cake with water content of 60 wt% using electrodewatering technology, compared with a 80 wt% using pressure filtration alone. The conventional filtration system using the electrodewatering shows the potential to be effective method for improving dewatering Sludge.

  • PDF

Characterization of depth filter media for gas turbine intake air cleaning

  • Park, Young Ok;Hasolli, Naim;Choi, Ho Kyung;Rhee, Young Woo
    • Particle and aerosol research
    • /
    • v.5 no.4
    • /
    • pp.159-170
    • /
    • 2009
  • A depth filter medium was newly designed in order to achieve high collection of dust and low pressure drop in this work. Multilayer depth filter media consist of an upstream layer of highly porous structure which allows particles to pass through and to follow by one or more downstream layers to hold the particles inside the media. For each filter media, flat sheet and pleated module were made of newly developed depth filter media and filter media of commercial products. Commercial depth filter cartridge for gas turbine air intake cleaning were used as reference for filtration area and pleat geometry of pleated modules. This work attempts to evaluate and compare the newly developed depth filter medium and two commercial filter media in terms of filtration parameters such as air permeability, initial pressure drop, particle retention and pressure drop variation with dust loading. According to the close examination the newly developed depth filter showed better performance compared to the commercial depth filter media.

  • PDF

Efficiency Evaluation of Different Processes in Drinking Water Treatment (정수처리에서 서로 다른 공정의 처리효율에 대한 비교분석연구)

  • Kim, Hyung-Suk;Lee, Byoung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.597-604
    • /
    • 2011
  • This study was performed to compare finished water quality among three different processes. A detailed assessment of performance was carried out during the five months of operation. Finished water quality was evaluated on the basis of parameters such as Dissolved organic carbon (DOC), $UV_{254}$ absorbance, haloacetic acid formation potential (HAAFP), geosmin, 2-methylisoborneol (2-MIB), heterotrophic bacteria and total coliform bacteria. The treatment processes were Process 1 (coagulation-flocculation-sedimentation-sand filtration-ozone-GAC), Process 2 (coagulation-flocculation-sedimentation -microfiltration-ozone-GAC), and Process 3 (coagulation-flocculation-sedimentation- sand filtration-GAC), compared side by side in the pilot testing. Process 2 was found to have better removal efficiency of DOC, $UV_{254}$ absorbance, HAAFP and heterotrophic bacteria in comparison with process 1 and process 3 under identical conditions. Geosmin, 2-MIB and total coliform bacteria were not detected in finished water from each process.

Micro-Filtration Performance of Metal Membrane md Fouling Reduction by Intermittent Ozonation (금속 막의 정밀 여과 특성 및 간헐적 오존 처리에 의한 막 오염 저감)

  • 김종오;정종태
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.66-74
    • /
    • 2004
  • Total resistance of membrane in a micro-filtration system using a metal membrane was mainly attributed to the permeate resistance of cake layer($R_c$), which was formed by deposited particles from the physico-chemical interactions of solids on membrane surface. Intermittent back ozonation was highly effective than the air backwashing for fouling reduction. As far the operational effect, under same ozone injection, the increase of gas flow-rate was more favorable than the increase of injection time far the recovery of permeation flux. As the filtration time was longer, the effect of flux recovery by intermittent back-ozonation decreased. Therefore, it is preferable to operate membrane cleaning before the foulant is consolidated on membrane surface.

A Study on Backwashing of Granular Fiters Used in Water Treatment (정수처리를 위한 여과지의 역세척에 관한 연구)

  • Lee, Jung Taek;Ahn, Jong Ho;Choi, Keun Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.3
    • /
    • pp.61-72
    • /
    • 1999
  • To obtain the experimental data for design and operation of actual filtration processes, a sand filter and three kinds of dual media filters in pilot-plant scale were operated in this study. We analyzed the effect of filter medium composition on the filter performance and the effects of backwash water flow rates, length of stream line and air flow rate on the filter backwash efficiency. We also compared the efficiencies of the combined air-water backwashing and the water backwashing in dual media filters. As the backwash water flow rates or the length of stream line increased, the final turbidity of backwash water was decreased and the filtration duration time after backwash was increased. In the case of the combined air-water backwashing, the backwash water quantity needed for backwashing the dual media filters could be decreased. The total volume of filtered water for the dual media filters during filter run was over three times larger than that for the sand filter. The dual media filters could be operated at a high filtration rate of 360 m/day.

  • PDF

Optimal Design Study for Development of Washable Faucet Assembly Housing Including Filtration Filter (여과필터를 포함한 세척이 가능한 수도꼭지 어셈블리 하우징 개발을 위한 최적설계 연구)

  • Son, In-Soo;Bae, Sang-Dae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.581-587
    • /
    • 2021
  • In recent years, contamination of drinking water sources has emerged as a serious social problem, such as a large number of impurities in tap water or groundwater or the supply of suitable water due to rust of pipes. Although the government and public institutions are implementing various measures to protect water sources, they cannot improve water quality in a short period of time because of the enormous cost involved. Therefore, in recent years, preference has been given to a device that converts tap water, which is hard water, into soft water by installing a separate water softener at the faucet from which tap water is discharged. However, the existing filtration device has a problem that filtration performance is gradually lowered when impurities accumulate in the filter, requiring continuous filter replacement. In this study, the optimal design of the filter housing was performed to develop a water softener that can be washed when impurities accumulate on the filter inside the water softener connected to the faucet. For optimal design of the filter housing, fluid and fluid-structural interaction analysis were performed on the design pressure to determine the shape and thickness of the housing, and design review was performed through prototype.