• 제목/요약/키워드: filtration efficiency

검색결과 513건 처리시간 0.026초

Appropriate Methods in Determining the Event Mean Concentration and Pollutant Removal Efficiency of a Best Management Practice

  • Maniquiz, Marla C.;Choi, Ji-Yeon;Lee, So-Young;Cho, Hye-Jin;Kim, Lee-Hyung
    • Environmental Engineering Research
    • /
    • 제15권4호
    • /
    • pp.215-223
    • /
    • 2010
  • This study attempted to develop and suggest a more appropriate method for the determination of event mean concentration (EMC) and pollutant removal efficiency of a stormwater best management practice (BMP) considering rainfall. The stormwater runoff and hydrologic data gathered from 22 storm events during a 28-month monitoring period on a swirl and filtration type of BMP were used to evaluate the developed methods. Based on the findings, the modified EMC method resulted in lower (average) values than the overall EMC, although the differences were not significant (P>0.05). By comparison, the developed 'Rainfall Occurrence Ratio' (ROR) method was most significantly correlated (r=0.967 to 988, P<0.009) with the other existing removal efficiency determination methods such as the 'Efficiency Ratio' (ER), 'Summation of Loads' (SOL) and 'Regression of Loads' (ROL) methods. In addition, the ROR method gave the highest efficiency values, with no significant differences with any of the pollutant parameters, unlike the other three methods. These results were obtained because the ROR method integrated both pollutant loading and rainfall, which are not considered by the other three methods. Therefore, this study proved the suitability of the modified EMC and ROR methods for application in other BMP monitoring studies.

BNR공정 처리수의 여과에 관한 연구 (A Study on the Filtration of BNR Process Effluent)

  • 김성용;범봉수;조광명
    • 대한환경공학회지
    • /
    • 제22권5호
    • /
    • pp.895-905
    • /
    • 2000
  • 본 연구는 여재가 모래와 무연탄인 복층 중력식 급속여과법으로 BNR(biological nutrient removal) 공정 유출수를 처리할 때 여과율의 변화에 따른 오염물질 제거효율 및 여층 깊이별 처리수질을 파악하기 위하여 수행되었다. Pilot scale의 4-stage BNR 공정 유출수를 200, 300 및 400 m/day의 여과율로 급속여과시킨 결과, 처리수는 2.6 NTU 이하의 탁도를 나타내어 우리나라의 중수도 제한수질인 5.0 NTU를 만족하였다. 여과율이 200, 300 및 400 m/day로 증가함에 따라 SS 제거효율은 각각 80.6, 75.4 및 68.9%로 감소하는 경향을 보였지만, 여과수는 모든 여과율에서 유입수의 수질변화에 큰 영향을 받지 않고 평균 1.3 mg/L의 SS 농도를 보였다. 생물학적 작용에 의하여 영양염류도 제거되었는데, 200, 300 및 400 m/day의 여과율에서 질산화효율이 각각 17.4, 18.8 및 14.3%, 그리고 탈질효율이 각각 32.3, 27.7 및 21.4%로, 질산화와 탈질이 동시에 일어났다. 여과주기의 후반기에는 여층 내의 DO가 결핍됨에 따라 인의 재용출이 일어남으로써 유출수의 T-P 농도가 유입수에 비하여 6.1~21.4% 증가하였다.

  • PDF

세라믹 막여과의 성능향상을 위한 응집 전처리의 적용 (Application of coagulation pretreatment for enhancing the performance of ceramic membrane filtration)

  • 강준석;송지영;박서경;정아영;이정준;서인석;채선하;김성수;김한승
    • 상하수도학회지
    • /
    • 제31권6호
    • /
    • pp.501-510
    • /
    • 2017
  • In this study, it is estimated that ceramic membrane process which can operate stably in harsh conditions replacing existing organic membrane connected with coagulation, sedimentation etc.. Jar-test was conducted by using artificial raw water containing kaolin and humic acid. It was observed that coagulant (A-PAC, 10.6%) 4mg/l is the optimal dose. As a results of evaluation of membrane single filtration process (A), coagulation-membrane filtration process (B) and coagulation-sedimentation-membrane filtration process (C), TMP variation is stable regardless of in Flux $2m^3/m^2{\cdot}day$. But in Flux $5m^3/m^2{\cdot}day$, it show change of 1-89.3 kpa by process. TMP of process (B) and (C) is increased 11.8, 0.6 kpa each. But, the (A) showed the greatest change of TMP. When evaluate (A) and (C) in Flux $10m^3/m^2{\cdot}day$, TMP of (A) stopped operation being exceeded 120 kpa in 20 minutes. On the other hand, TMP of (C) is increased only 3 kpa in 120 minutes. Through this, membrane filtration process can be operated stably by using the linkage between the pretreatment process and the ceramic membrane filtration process. Turbidity of treated water remained under 0.1 NTU regardless of flux condition and DOC and $UV_{254}$ showed a removal rate of 65-85%, 95% more each at process connected with pretreatment. Physical cleaning was carried out using water and air of 500kpa to show the recovery of pollutants formed on membrane surface by filtration. In (A) process, TMP has increased rapidly and decreased the recovery by physical cleaning as the flux rises. This means that contamination on membrane surface is irreversible fouling difficult to recover by using physical cleaning. Process (B) and (C) are observed high recovery rate of 60% more in high flux and especially recovery rate of process (B) is the highest at 95.8%. This can be judged that the coagulation flocs in the raw water formed cake layer with irreversible fouling and are favorable to physical cleaning. As a result of estimation, observe that ceramic membrane filtration connected with pretreatment improves efficiency of filtration and recovery rate of physical cleaning. And ceramic membrane which is possible to operate in the higher flux than organic membrane can be reduce the area of water purification facilities and secure a stable quantity of water by connecting the ceramic membrane with pretreatment process.

수평흐름식 여과기술의 CSOs 적용을 위한 공정 최적화 연구 (A Study on Process Optimization for CSOs Application of Horizontal Flow Filtration Technology)

  • 김재학;양정하;이영신
    • 한국산학기술학회논문지
    • /
    • 제19권2호
    • /
    • pp.56-63
    • /
    • 2018
  • 강우사상이 발생함에 따라 시설용량을 초과하여 미처리된 상태로 방류수계에 직접 배출되는 합류식 관거 월류수(Combimed Sewer Overflows, CSOs) 및 분류식 관거 월류수(Separated Sewer Overflows, SSOs)의 관리는 집중호우가 잦아지는 근래에 들어 그 관리가 더욱 중요해지고 있다. 밀집도가 높은 도심지에 적용성이 유리한 여과기술은 지속적인 개발이 이루어지고 있음에도 불구하고 CSOs에 적용된 사례가 거의 전무한 실정이다. 따라서 본 연구에서는 로프형 섬유여재가 적용된 Pilot 규모의 수평흐름식 여과장치를 CSOs에 적용하기 위해 공정최적화를 목적으로 수행되었다. 연구방법은 인공시료를 적용한 사전연구와 하수를 적용한 현장연구로 구분하여 수행하였다. 인공시료를 적용한 사전연구에서 여재 자체의 손실수두는 약 1.1cm정도로 분석되었고, 선속도 10m/hr 증가에 따라 약 0.1cm 정도의 손실수두 증가를 유발하는 것으로 나타났다. 또한, SS 제거효율은 81.4% 정도로 안정적이었고, 여과지속시간은 6시간 이상 유지되었으며, 공기역세척만으로도 98% 정도의 손실수두 평균 회복율을 보였다. 하수를 적용한 현장평가에서는 여재의 조기폐색을 방지하기 위한 전처리공정으로 벨트 형 미세스크린(450mesh 이상)를 적용했을 때 2시간 내외의 여과지속시간을 확보할 수 있었고, 평균 83.9%의 SS 제거효율을 나타내었다. CSOs 및 SSOs에 여과공정 적용을 위해서는 효율적 측면보다 여과지속시간의 안정적 유지를 위한 수리적 측면을 보완하기 위해서 전처리공정과의 조합이 중요하다는 결론을 얻을 수 있었다. 건기와 비교하여 우기의 유입하수 수질은 다소 낮은 보였으며, 이는 분류식 관거 비율이 높은 배수구역의 특성 때문인 것으로 추정된다. 또한, 우기와 건기의 유입수질에 따른 제거효율 차이는 미미하였다.

상수 정화법에 관한 연구 (폭기식 다단여과에 의한 호기성균의 생물화학적 산화작용을 응용) (A Study on Purification of Water Works by Multi-filter Bed Method with Aeration(Appliction of Biological Oxidation by Aerobic Microorganism))

  • 정요한;문재규;주흥규;서화중
    • Journal of Preventive Medicine and Public Health
    • /
    • 제5권1호
    • /
    • pp.43-48
    • /
    • 1972
  • 5 bed sand filter, applying biological oxidation, was designed and studied on the treatment of water works. Never using any coagulant agent (drugs), which may cause water pollution in pre-treatment of head water, the auther attempt a high rate filtration by the microorganism (nitrofication bacteria) end plant which populate in multi layer sand beds. The result are as follows : In order to evaluate the oxygen effect on filtration, oxygen was injected in aeration tank attached to each filter tank while filtration, and $NH_3$ was tested as a representaiive ingredient. It was found out that the aeration method was more effective, with over 33% of $NH_3$ removal capacity, than the anerobic and this 5 bed filter showed double removal capacity of $NH_3$ by comparing with conventional sand bed (2 stage bed). According to the examination of two kind of head water, pre-treated with coagulant agent and activated carton, the filtration capacity was affected by the polluted condition of head water, resulting that lower value of pollution and slower velocity of filtration showed more efficiency of $NH_3$ removal. In this experiment $NH_3$ content tested in treated water had a fairly good correlation with others.

  • PDF

강변여과수 시설에서의 지열에너지 활용 가능성 평가 (Assessment for geothermal energy utilization in the riverbank filtration facility)

  • 신지연;김경호;배광옥;이강근;정우성;석희준;김형수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.485-488
    • /
    • 2007
  • Riverbank filtration is a kind of artificial aquifer recharge for the fresh water supply. By construction of several production wells penetrating the riverbank, surface water withdrawn from the river would pass riverbed. This extracted water is well known to be cooler than surface water in summer and warmer than surface water in winter, showing more constant water temperature. This characteristic of extracted water is applied to geothermal energy utilization. Prediction of the annual temperature variation of filtrated water is the major concern in this study. In Daesan-myeon, Changwon-si, Gyeongsangnam-do, South Korea, riverbank filtration facility has been on its operation for municipal water supply and thermal energy utilization since 2006. Appropriate hydraulic and thermal properties were estimated for flow and heat transfer modeling with given pumping rate and location. With the calibrated material properties and boundary conditions, we numerically reproduced measured head and temperature variation with acceptable error range. In the numerical simulation, the change of saturation ratio and river stage caused by rainfall was calculated and the resulting variation of thermal capacity and thermal conductivity was considered. Simulated temperature profiles can be used to assess the possible efficiency of geothermal energy utilization using riverbank filtration facility. Influence of pumping rate, pumping location on the extracted water temperature will be studied.

  • PDF

심층여과지의 여층구성에 따른 여과특성 비교 (Characteristics of Depth Filtration for Various Filter-Bed Configurations)

  • 안종호;윤재흥
    • 한국수자원학회논문집
    • /
    • 제34권5호
    • /
    • pp.459-472
    • /
    • 2001
  • 모형실험장치를 이용하여 심층여과지에 대한 여층구성별 여과효율 평가를 통해 여과지 설계시의 여층구성에 대한 기초자료를 제공하는 것이 본 연구의 목적이다. 여과지속시간에 따른 손실수두 발달특성을 보면 여과초기의 수두손실은 이중여재 여과지가 높지만 탁질 억류에 의한 수두손실의 증가는 완만하여 여과속도 180 m/day의 동일한 여과속도를 적용하였을 경우, 조림심층 모래여과지에 비해 단위정수생산량이 30-40% 정도 증대되는 것으로 나타났다. 여과수질은 각각 여과속도 180 m/day, 240 m/day로 운전한 결과 여과속도에 관계없이 모두 0.1 NTU 이하를 나타내어 만족하는 여과수질을 보였다. 그러나 여과초기 탁질 누출 특성을 보면 상대적으로 조립심층 모래여과지의 누출 경향이 크게 나타났고, 여과속도 240 m/day로 증대됨에 따라 그 경향은 보다 뚜렷하게 나타났다.

  • PDF

Effects of Temperature and Salinity on the Survival and Metabolism of Tresus keenae (Mollusca: Bivalvia)

  • Shin Yun Kyung;Yang Moon-Ho
    • Fisheries and Aquatic Sciences
    • /
    • 제8권3호
    • /
    • pp.161-166
    • /
    • 2005
  • We examined the variation in survival and the respiration and filtration rates of Tresus keenae in response to changes in water temperature and salinity. The survivorship of animals exposed to temperatures below $25^{\circ}C$ for 7 days was $80\%$; however, all test animals died on the fourth day at $28^{\circ}C$. The upper lethal temperature over 7 days was $25.9^{\circ}C$. After exposure to lower temperatures, $93\%$ ofthe animals survived at temperatures over $5^{\circ}C$ for 10 days. Survivorship rapidly decreased below $4^{\circ}C$ with all test animals dying at $2^{\circ}C$ on the eighth day. The $LT_{50}$ over 10 days was $4.8^{\circ}C$. The respiration and filtration rates of T. keenae increased as temperature increased. It is believed that energy consumption increases as a result of the increased respiration rate at temperatures above the upper lethal temperature. At temperatures below the lower lethal temperature, the metabolic rate of T. keenae was substantially lowered. In response to changes in salinity, the survivorship of T. keenae was $90\%$ at 30.2 psu after exposure for 5 days; at below 26.8 psu, all test animals died by the fifth day. The $LS_{50}$ was 29.1 psu. As salinity decreased, both the respiration rate and the filtration rate decreased. At 23.5 psu, the respiration and filtration rates decreased by 48 and $34\%$, respectively. These data have implications for increasing efficiency in the production and management of shellfish aquaculture farms.

Improvement of Virus Safety of an Antihemophilc Factor IX by Virus Filtration Process

  • Kim, In-Seop;Choi, Yong-Woon;Kang, Yong;Sung, Hark-Mo;Sohn, Ki-Whan;Kim, Yong-Sung
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권7호
    • /
    • pp.1317-1325
    • /
    • 2008
  • Viral safety is an important prerequisite for clinical preparations of plasma-derived pharmaceuticals. One potential way to increase the safety of therapeutic biological products is the use of a virus-retentive filter. In order to increase the viral safety of human antihemophilic factor IX, particularly in regard to non-enveloped viruses, a virus removal process using a polyvinylidene fluoride membrane filter (Viresolve NFP) has been optimized. The most critical factor affecting the filtration efficiency was operating pH and the optimum pH was 6 or 7. Flow rate increased with increasing operating pressure and temperature. Recovery yield in the optimized production-scale process was 96%. No substantial changes were observed in the physical and biochemical characteristics of the filtered factor IX in comparison with those before filtration. A 47-mm disk membrane filter was used to simulate the process performance of the production-scale cartridges and to test if it could remove several experimental model viruses for human pathogenic viruses, including human hepatitis A virus (HAV), porcine parvovirus (PPV), murine encephalomyocarditis virus (EMCV), human immunodeficiency virus type 1 (HIV), bovine viral diarrhea virus (BVDV), and bovine herpes virus (BHV). Non-enveloped viruses (HAV, PPV, and EMCV) as well as enveloped viruses (HIV, BVDV, and BHV) were completely removed during filtration. The log reduction factors achieved were $\geq$6.12 for HAV, $\geq$4.28 for PPV, $\geq$5.33 for EMCV, $\geq$5.51 for HIV, $\geq$5.17 for BVDV, and $\geq$5.75 for BHV. These results indicate that the virus filtration process successfully improved the viral safety of factor IX.

강변여과수 취수를 위한 충적우물에서 필터층이 수위강하특성, 투수성, 적정양수량 및 우물효율에 미치는 영향에 대한 현장실증 연구 (A Field Verification Study on the Effect of Filter Layers on Groundwater Level Drop Characteristics, Permeability, Optimum Yield and Well Efficiency in the Unconfined Aquifer Well for Riverbank Filtration Intake)

  • 송재용;이상무;강병천;이근춘;정교철
    • 지질공학
    • /
    • 제29권4호
    • /
    • pp.509-529
    • /
    • 2019
  • 본 연구는 강변여과수 취수를 위한 충적우물에서의 필터재의 역할과 이중필터 취수정의 적용성 및 개선효과를 평가할 목적으로 수행하였다. 토층으로 이루어진 하천변의 자유면대수층에서 필터 조건을 달리 하여 실규모의 이중필터 취수정과 단일필터 취수정을 각각 설치하고 설치된 우물에서 대수성 시험을 실시하여 필터재 조건에 따른 수위강하특성, 투수특성, 적정 양수량 및 우물 효율을 평가하였다. 결과적으로, 이중필터층을 형성시켜 주는 것은 대수층과 필터층의 경계부에서 지하수 유동의 완충작용을 하여 유입되는 지하수의 급격한 속도변화를 최소화하는 효과를 나타내는 것으로 추정된다. 이는 난류 발생을 최대한 억제하여 보다 넓은 범위의 지하수를 효과적으로 취수정 내부로 유입시키는 역할을 하고 이로 인하여 취수량이 단일필터 취수정에 비해 높음에도 불구하고 주변 지하수위의 변화를 줄일 수 있는 것으로 보인다. 또한, 이중필터의 설치만으로도 기존 시스템(단일필터 취수정) 대비 투수성, 적정 양수량, 우물 효율이 개선됨을 시험을 통해 확인할 수 있었다. 본 연구의 결과는 앞서 수행한 다양한 연구와 종합하여 충적대수층에서의 이중필터 취수정 우물의 설계 및 시공에 대한 표준화된 기준을 마련하는데 활용할 계획이다. 또한, 강변여과수에 주로 적용되고 있는 단일 필터 취수정 및 방사상집수정과 대비하여 이중필터 취수정 적용 효과에 대한 객관적 입증 자료로의 활용이 기대된다.