• Title/Summary/Keyword: filtration efficiency

Search Result 513, Processing Time 0.027 seconds

Variation of Flow and Filtration Mechanisms in an Infiltration Trench Treating Highway Stormwater Runoff (고속도로 강우유출수 처리를 위한 침투도랑에서 흐름조건에 따른 여과기작 및 효율분석)

  • Guerra, Heidi B.;Yu, Jianghua;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.20 no.1
    • /
    • pp.63-71
    • /
    • 2018
  • The particle filtration mechanisms in an infiltration trench should be varying due to the different hydraulic conditions during stormwater runoff. The understanding of these variations associated with different filtration mechanisms and their effect on the particle removal efficiency is of vital importance. Therefore, a LID (Low Impact Development) system comprising of an infiltration trench packed with gravel and woodchip was investigated during the monitoring of several independent rainfall events. A typical rainfall event was divided into separate regimes and their corresponding flow conditions as well as filtration mechanisms in the trench were analyzed. According to hydraulic conditions, it was found out that filtration changes between vertical and horizontal flows as well as between unsaturated, saturated, and partially-saturated flows. Particle separation efficiency was high (55-76%) and was mainly governed by physical straining during the unsaturated period. It was then enhanced by diffusion during the saturated period (75-95%). When the trench became partially saturated at the end of the rainfall event, the efficiency decreased which was believed to be due to the existence of a negatively charged air-water interface which limited the removal to positively charged particles.

Synthetic Permeable Medium Filtration for Secondary Effluent Reclamation (방류수 재이용을 위한 합성투과 여재 여과)

  • Park, Ki Young;Maeng, Sung Kyu;Kim, Ki-pal;Kweon, Ji Hyang;Yoon, Hyon-Hee;Ahn, Kyu Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.3-7
    • /
    • 2005
  • In the present study a feasibility of a novel filtration process using synthetic for secondary effluent reclamation was investigated. Polyurethane was chosen as a filter medium among tested three media. Compressibility and up-flow velocity were changed to determine the optimum operation for the system. An equation was introduced to express the relationship between the removal efficiency and up-flow velocity. In pilot study, the synthetic medium filtration with compression showed very stable effluent quality without clogging trouble, though the system operated with 3 times higher filtration rate and much longer backwashing interval than conventional systems.

Experimental Evaluation of Filter Performance of Depth Filter Media Cartridge with Varying the Pleat Count and the Cartridge Assembly Arrangement

  • Hasolli, Naim;Park, Young-Ok;Rhee, Young-Woo
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.133-141
    • /
    • 2012
  • A new depth filter media was designed and samples of flat sheet as well as cartridge assembly were prepared and tested to evaluate the filtration performance and compare with the commercial product. The arrangement of the depth filter media layers is important to reach the optimal filtration parameters like filter pressure drop, particle collection efficiency and dust holding capacity. Initially, both flat sheet samples of new media and commercial product have been tested using standard test units. Tests with new depth filter media cartridges of various pleat count were conducted in order to find the optimal pleat count which would represent the lowest pressure drop. These tests give an insight on how the pleat count and the assembly configuration affect the performance of the depth filter media cartridge. By comparing the samples with a commercial product we could confirm relatively high filtration performance of the sample cartridge with pleat count 150 made of new depth filter media. The cartridge with the same pleat count exhibits better performance without the outer mesh.

A Study on Effect of Jet Mixed Separator Combination for Pre-treatment of Ultrafiltration Membrane Filtration Process (UF 막 여과 공정의 효과적인 전처리 공정으로 분류교반고액분리조(噴流攪拌固液分離槽) (Jet Mixed Separator: JMS) 도입 효과에 관한 연구)

  • Lee, Sanghyup;Jang, Nakyong;Watanabe, Yoshimasa
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.38-46
    • /
    • 2005
  • In this research, we tried to combine the coagulation/sedimentation process as pre-treatment with UF membrane filtration to reduce the membrane fouling and to improve the permeate water quality. We used the Jet Mixed Separator (JMS) as coagulation/sedimentation process. We observed that the HPC and E.Coli can't be removed through the direct UF memebrane filtation of surface water. The removal efficiency of dissolved organic substances, indicated by E260 and DOC, was 40% and 15%, respectively. However, the removal efficiency of it increased two time as a result of combination of JMS process as coagulation/sedimentation pre-treatment. This was resulted from the formation of high molecular humic micro-floc through JMS process. The accumulation amount of irreversible cake layer which was not removed by backwashing was less than direct UF membrane filtration of surface water. Moreover, the loading rate of fouling induced substances, such as humic substances and suspended substances, on membrane surface decreased drastically through JMS process. As a result, the accumulation amount of irreversible cake on membrane surface was decreased.

A Study on the Development of Dust Collection System for Hull Repair (선체 표면 공사시 발생하는 분진 수거 장치 개발에 관한 연구)

  • Yoa, S.J.
    • Journal of Power System Engineering
    • /
    • v.8 no.2
    • /
    • pp.31-38
    • /
    • 2004
  • The main purpose of this study is to investigate the characteristics of hybrid collection system combined with centrifugal force of cyclone and filtration of bag filter in one unit system. The experiment and numerical simulation are executed for the analysis of collection efficiency and pressure drop characteristics of hybrid system in comparison with those of a general fabric bag filter with the various experimental parameters such as inlet velocity(filtration velocity), dust concentration and dust type, etc.. In present system, dust particles tangentially coming into the system body are controlled by the centrifugal force effect, and the next collection is made out by the filtration mechanism in the fabric filter media. Therefore, the effective first collection causes the decrease of dust loading on the fabric filter, and it presents quite a lower pressure drop of fabric filter than that of a general fabric filter. At the inlet velocity, $21{\sim}27m/sec$ and inlet concentration(fly ash) $300mg/m^3$, pressure drops through the filter media of hybrid system are shown lower as $10{\sim}22mmH_2O$ comparing to those($17{\sim}33mmH_2O$) of a general fabric bag filter.

  • PDF

Filtration Characteristics of Metal Foam Filters for DPF Combined with Electrostatic Precipitation Mechanism (전기집진 기제를 조합시킨 DPF용 금속 폼 필터의 여과 특성)

  • Park, Seok-Joo;Lee, Dong-Geun;Kim, Jin-Hyun;Cho, Gyu-Baek;Kim, Hong-Suk;Jeong, Young-Il
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.151-158
    • /
    • 2007
  • Filtration studies, using simulated test nanoparticles or diesel nanoparticles, have been performed about Inconel foam filters for DPF combined with electrostatic precipitation. The simulated test particles were synthesized by laser ablation in the nitrogen atmosphere at the standard condition. The diesel particles were exhausted from the diesel engine driven on the condition of idle or load mode. Filtration efficiency of the metal foam filter is very low because most of particles are penetrated through the large pores of filter. However, the efficiency was considerably improved by applying the electric field to the filter and/or charging the nanoparticles. Nevertheless, the pressure drop of filter hardly increased because the filter-pores were not clogged by deposited particles and kept open.

Fine Particle Removal by a Vehicle Air Cleaner (차량용 에어클리너의 미세입자 제거특성)

  • Park, Byung-Hyun;Kim, Sang-Bum;Kim, Gyung-Soo;Lee, Sang-Ryul;Lee, Myong-Hwa
    • Journal of ILASS-Korea
    • /
    • v.12 no.2
    • /
    • pp.86-93
    • /
    • 2007
  • There is a growing interest to develop an eco-friendly air cleaner with high performance through a remanufacturing process. Two kinds of polyurethane filter media, a coarse (Filter-A) and a fine filter media (Filer-B), are used in this study to protect a vehicle engine from airborne particles. In order to improve the collection performance of the filters (Filter-A, Filter-B), an oil coating technology on the filter surface was introduced. As a result, inertial force is a dominant collection mechanism for a dry filter media, so that collection efficiency increases with increasing filtration velocity. However, intra-structure change of an oil-coated filter media influences on the collection mechanism, which shows a non-linear collection efficiency curve in terms of filtration velocity. The result shows that the developed filter media are eco-friendly and effective to protect a vehicle engine from airborne particles especially at low filtration velocity.

  • PDF

The Effects of Anthracite Media Sphericity on Filtration Efficiency (안쓰라사이트 여재 원형도가 여과 효율에 미치는 영향)

  • Cheong, Won-suk;Choi, Suing-il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.763-770
    • /
    • 2007
  • There are many design parameters affecting filtration efficiency such as filteration rate, media packing depth, size distribution, and so on. The sphericity, the ratio of the surface area of an equal volume sphere to the real surface area of the particles, is one of major physical characters of media. The effect of sphericity on the performance of anthracite filter has been investigated. Media from eight water treatment plants have been collected. The sphericity of each media has been calculated by using well known headloss equations such as Kozeny equation, Dahmarajah equation etc.. Columns packed with anthracite media having different sphericity have been used to compare headloss development, floc accumulation in the bed, particles in bed water, filtrate turbidities after backwash and so on. The repeated experiments have indicated that the sphericity of anthracite media may not have remarkable influence on the filter performance as it has been suspected. It also has been prospected in the experiment that the media of higher sphericity would store more particles in the bed and give better filtrate quality, if provided that the effective size and the size distribution of media would be the same.

Efficiency Evaluation of Different Processes in Drinking Water Treatment (정수처리에서 서로 다른 공정의 처리효율에 대한 비교분석연구)

  • Kim, Hyung-Suk;Lee, Byoung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.597-604
    • /
    • 2011
  • This study was performed to compare finished water quality among three different processes. A detailed assessment of performance was carried out during the five months of operation. Finished water quality was evaluated on the basis of parameters such as Dissolved organic carbon (DOC), $UV_{254}$ absorbance, haloacetic acid formation potential (HAAFP), geosmin, 2-methylisoborneol (2-MIB), heterotrophic bacteria and total coliform bacteria. The treatment processes were Process 1 (coagulation-flocculation-sedimentation-sand filtration-ozone-GAC), Process 2 (coagulation-flocculation-sedimentation -microfiltration-ozone-GAC), and Process 3 (coagulation-flocculation-sedimentation- sand filtration-GAC), compared side by side in the pilot testing. Process 2 was found to have better removal efficiency of DOC, $UV_{254}$ absorbance, HAAFP and heterotrophic bacteria in comparison with process 1 and process 3 under identical conditions. Geosmin, 2-MIB and total coliform bacteria were not detected in finished water from each process.

A Study on the Effect of Dust Precharging on Filtration Performance

  • Park, Y.O;Park, S.J.;Lee, J.H.;Kim, S.D.;Park, H.S.;Park, H.K.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E2
    • /
    • pp.53-59
    • /
    • 2001
  • A hybrid dust-collector combining electrostatic charging with fabric filtration method was developed, and its performance characteristics were evaluated in this study. Charged particles build porous dendritic structure on the surfaces of filter by electrostatic attraction, increasing the collection efficiency of dust particles and reducing the pressure drop through the deposited dust layer and filter media. The cleaning performance of the dust layer is improved because the dendritic structured dust layer can be removed more easily by pulse jet cleaning flow. The results of the experiment showed a reduction of fine particle emission of 37% and the energy saving of 13% by precharging dust particles before filtration.

  • PDF