• Title/Summary/Keyword: filteration rate

Search Result 23, Processing Time 0.023 seconds

Study of High Rate Filter. (고속여과의 효과에 관한 연구)

  • 박인규
    • Water for future
    • /
    • v.10 no.2
    • /
    • pp.91-100
    • /
    • 1977
  • This is an experimental study to raise higher efficiency of filteration than conve ntional filteration by increasing of filteration capacity for per unit area and by extending of filteration lasting time with biflow filter system which was improved from the conventional rapid sand filteration method in the process of water purification treatment. In order to raise more efficient function of filteration and giving consideration to the filter layer at upper and lower parts of the filter, the fine sand & an thracite were used as a filter medium. Although there is some difficulty than previous fine sand in procurement, it could confirm that such filter medium (fine sand & anthracite) was more effective in the field of load, lasting time and back wash, etc. In consideration of practical effect of filteration. The raw water which was used for this experimental study was not coagulated. As a result of this experiment, the filteration volume could increase more than 2 times than that of conventional method. Besides, much more advantages could be obtained for instance, the requirement of installation area was not much and installation cost could economize. On the other hand, the following results were found. The quality of filtered water became worse as time goes by and the turbidity of filtered water was more influenced by raw water turbidity than by rate of filteration. Lasting time of filteration on change of filteration rate in the filter layer reached 2 times in comparison with previous filter basin, and until loss gead reached to 1.0 meter and 1.5 meter, the following relate formulas between lasting time and rate of filteration were formed. ($T_{1.5}=181.96V^{-0.46},\;T_{1.0}=121.31V^{-0.46}$) Even though the lasting time can be shorten in case of the increase of the filteration rate, but the lasting time was prolonged more than 2 times than of previous method. With taking aim at contribution to the development of water treatment technique, we are planning to study continuously for the future study basing on the results in this papers.

  • PDF

Evaluation of Renal Function Determined by Relative Renal Uptake of $^{99m}Tc-DMSA$ and Relative Glomerular Filteration Rate of $^{99m}Tc-DTPA$ ($^{99m}Tc-DMSA$$^{99m}Tc-DTPA$의 상대적 신섭취율을 이용한 신기능의 평가)

  • Chung, Byung-Chun;Choi, Chung-Il;Kim, Kwang-Weon;Lee, Jae-Tae;Lee, Kyu-Bo;Kwon, Tae-Hwan;Cho, Dong-Kyu
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.227-236
    • /
    • 1991
  • Background: The evaluation of individual renal function is important to diagnosis and follow-up of various diseases. Ureteral catheterization of each kidney has been widely used for this purpose, but this method had some technical difficulty, frequent complications and much restriction in reapplication. Therefore we tried to applicate radiopharmaceuticals for the evaluation of individual renal function. Methods: We measured 2 hour, 4 hour and 24 hour relative renal uptake of $^{99m}Tc-DMSA$ and relative glomerular filteration rate of $^{99m}Tc-DTPA$ with 59 patients with various renal diseases to determine their usefulness for assessment of individual renal function and to compare correlations between every renal uptake of $^{99m}Tc-DMSA$ and relative glomerular filteration rate. Results: The correlations between 2 hour-, 4 hour- and 24 hour- relative renal uptake of $^{99m}Tc-DMSA$ and relative glomerular filteration rate of $^{99m}Tc-DTPA$ were R=0.9190 (p < 0.001), R: 0.9229 (p<0.001) and R=0.9917 (p<0.001). In acute obstructive uropathy, the correlations at 2 hour and 4 houre were poor as R=0.1812 (p<0.05) and R=0.4923 (p < 0.05), but the correlation at 24 hour was good as R=0.9942 (p<0.001). Conclusions: We concluded that relative renal uptake at 2 hour and 4 hour had good correlation with relative DTPA uptake ratio in the cases without chronic renal failure and obstructive uropathy. Delayed image with 24 hour relative renal uptake $^{99m}Tc-DTPA$ had the best correlation with relative glomerular filteration rate of $^{99m}Tc-DTPA$ and that might be useful in evaluation of chronic renal disease in which showed increased beckground activity or acute obstructive uropathy.

  • PDF

A Study on Filtration Performance Test with Electrostatically Enhanced Fabric Filter (정전형여과집진방식에서 여과특성에 관한 연구)

  • 천중국;박출재;최금찬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.361-367
    • /
    • 1995
  • This study has been carried out to investigate the filteration performance of Electrostatically Stimulated Fabric Filter(ESFF) at high temperature condition. The electric field was maintained parallel to the fabric surface. The benefits of ESFF are lower residual pressure drop, improvement of fine particle removal efficiency and increasing reduced rate of pressure drop during a filteration cycle, stable operation at higher filtering velocities. According to the variance of filtering velocities and dust loadings, the results are summarized as follows; By imposing an electric field on the filter, the reduced rate of pressure drop was 7.sim.18% at room temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Under the electric field around the filter, the reduced rate of pressure drop was 10.sim.35% at high temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Most of all, at high temperature, the value of reduced rate of pressure drop was resulted to 25%. Also the collecting efficiency was shown clearly improved. By the SEM photo analysis, the number of penetrated particles at the Conventional Fabric Filter was approximately two times that of Electrostatically Stimulated Fabric Filter.

  • PDF

Influence of Oxytocin on the Renal Function of the Chicken (닭의 신장기능(腎臟機能)에 미치는 Oxytocin의 영향(影響))

  • Ko, Suk-Tai
    • Journal of Pharmaceutical Investigation
    • /
    • v.1 no.1
    • /
    • pp.34-46
    • /
    • 1971
  • The existence of oxytocin in the pituitary gland of chicken has been ascertained, but its physiological roles are still obscure. In the study the action of oxytocin on renal function of the chicken was investigated during water diuresis, utilizing clearance and the Sperber technique. The results obtained are summarized as follows: Oxytocin, like in many species of mammals, elicited a profound diuretic response in the chicken. Urine flow, excretion of electrolytes, as well as glomerular filteration rate increased, with intravenous infusion of $3{\sim}10\;m{\mu}/kg/min$. Oxtocin, infused into the renal portal circulation via hindleg vein in a dose of $3{\sim}13\;m{\mu}/kg/min$. elicited marked increase in urine flow, glomerular filteration rate and sodium excreted in the urine. The diuretic effect was more pronounced in the infused side. It is suggested that diuretic response to oxytocin in the chicken results from dual action of oxytocin: increase of GFR and inhibition of sodium reabsorption on the renal tubule. The possibility that oxytocin might act through some endogenous substances could be ruled out.

  • PDF

The vertical environmental characteristics in the tidal flat sediments (갯벌의 수직적 환경 특성)

  • 김종구;유선재
    • Journal of Environmental Science International
    • /
    • v.9 no.2
    • /
    • pp.125-129
    • /
    • 2000
  • As one of the fundamental survey to evaluate purification capacity of pollutants at the tidal flat sediments, we studied vertical environmental characteristics in three tidal flat sediments, Chunjangdae, Eueunri and Gyewhado. These are dissmilar to external feature in each other. The results of this study may be summarized as followed; As the results of particle analysis, Eueunri tidal flat fediment located in Keum river estuary consists of 98.98% as silt & clay, Chunjangdae tidal flat sediment located in SeocheonGun consists of 97.99% as sand. And Gyewhado tidal flat sediment located in Saemankeum in Saemankeum area consists area consists of 32.81% as silt & clay and 67.19% as sand. The concentration of organic pollutants(I.L., COD, POC, PON) in Eueunri tidal flat sediment which highly content of silt & clay were 3~4 times higher than others. The concentration of organic pollutants at each layer were slightly increase goes with deepen layer. The linear correlation between I.L. and COD, POC, PON were obtained. Correlation coefficients were in range of 0.821~0.940. Also the correlation between pH and COD, POC, PON were high(>r=0.9). Filteration rate in Chunjangdae tidal flat sediment was 0.01584cm/s as mean value, but the other were almost nothing filtered off.

  • PDF

EFFECT OF SOME PESTICIDES TO THE ABILITY OF THE FILTERATION AT EEL CULTURE USING RBCIRCULATING FILTER SYSTEM (순환여과장치이용의 뱀장어사육시 어병방제약품이 여과조기능에 미치는 영향)

  • KIM In-Bae;PARK Myeong Ja
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.7 no.4
    • /
    • pp.187-194
    • /
    • 1974
  • When rearing fish at recirculating filter systems, some pesticides are often used for controling various fish diseases. In this case, the pesticides are usually applied after stopping the filteration, from a view point of affecting the filtering ability of oxidation and decomposition by killing the decomposing bacteria in the filter system. Therefore, a great inconvenience is usually net. The authors carried out a series of experiments, and the influence of 3 kinds of treatments of pesticides, formalin 33 ppm+matachite green 0.15 ppm, dipterex 0.25 ppm, and furanace 0.1 ppm, to the filtering ability expressed as the consumption rate of dissolved oxygen and depletion of ammonia-nitrogen during the passing time through the filter layer was investigated, and it was found out that these pesticides with above mentioned concentrations which is normally used for controling several kinds of diseases and parasites during the time of eel culture, did not affect the filtering ability. Consequently, it can be said that these pesticides with above mentioned concentrations can he used without stopping filteration.

  • PDF

Dose Characteristics by the Co-60 Source Oscillations in High Dose Rate After Loading Irradiations (고선량율 원격강내조사의 코발트-60 이동선원에 의한 선량특성)

  • 최태진;김옥배;노홍균
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.51-60
    • /
    • 1990
  • Dose distributions around Co- 60 moving source in high dose rate remote afterloading unit, Buchler 3K unit, were experimented with X-omat V films and calculations. In our experiments, film dosimetries have achieved to evaluated the axial dose distributions for source oscillations were 0, 3.5, 5.0 and 6.0 cm in periodically, In results, the dose distributions in axial of source movement showed apparently higher than in transverse direction caused by source locations, dwelling time and air gap in the applicator. In the calculations, the dose rate was derived by using the inverse square law, filteration corrections and Meisberger constant for scatter corrections as source movings. In our experiments and calculations, the average dose uncertainties were showed -2.1$\pm$1.9% in fixed sourdce, -2.9$\pm$1.8%, -7.4$\pm$6.1% and -6.7$\pm$4.6% at 3.5 cm, 5.0 cm and 6.0 cm source oscillations, but the calculations have showed very close to experimental dose rate within 4 cm distance from source.

  • PDF

Removal Efficiency in Water Treatment Process and Characteristic of Cell Sensitivity of Waterborne Enteric Viruses (수계 바이러스의 정수처리공정별 제거율 및 세포주별 감염특성 조사)

  • Jung, Eun-Young;Park, Hong-Gi;Cha, Dong-Jin;Jung, Mi-Eun;You, Pyung-Jong
    • Journal of Life Science
    • /
    • v.19 no.3
    • /
    • pp.373-377
    • /
    • 2009
  • Poliovirus, coxsackievirus, and ecovirus isolates from environmental sources were compared with laboratory strains to determine their removal rate in the water treatment process. The recovery efficiencies of poliovirus, coxsackievirus and echovirus using positive strains ranged from $72{\sim}108%$. Regarding virus removal efficiency in water treatment of pilot-plants, about 99% of all of the viruses were removed in the sedimentation step and 100% of viruses were clearly removed through post-ozonation and BAC filteration. Using six cell lines tested viral sensitivity in cell line and showed different sensitivity as viruses. Polioviruses showed higher sensitivity in the BGMK cell line than other cells, and coxsackieviruses were detected in higher level in the BGMK and Vero cell lines. On the other hand, the RD cell line was useful in the isolation of ecoviruses.

The Degumming and Sericin Recovery of the Silk fabric Using the Electrolytic Water(II) (전해수를 이용한 견섬유 정련 및 세리신 회수(II)-분리막에 의한 세리신 농축을 중심으로-)

  • 배기서;이태상;노덕길;홍영기
    • Textile Coloration and Finishing
    • /
    • v.16 no.4
    • /
    • pp.10-18
    • /
    • 2004
  • In this work, Aqueous sericin solution was prepared by degumming process with electrolytic reduction water. Then, the microfiltration and ultrafiltration systems were applied to the concentration of aqueous sericin solution. The objective of this study was to select the optimum operating condition among the different pressure. The permeate flux and rejection ratio were observed with time, pressure, flow rate and concentration. and, the wastewater and permeated water quality values such as pH, BOD, COD, and NH levels were measured. In order to see the influence of electrolytic reduction water, the flux of pure water and electrolytic reduction water by PVDF22(MF) and PS100(UF) membrane was measured. In microfiltration system, the relative flux reduction decreased rapidly to 0.02 in the 30min, as the concentration polarization and gel layer formation were increased. and then the sericin concentration rejection ratio was 40%. In ultrafiltration system, the permeate flux decreased with time and concentration, and increased with the operating pressure and flow rate. Optimal condition in PS100 membrane system for sericin concentration was operating pressure 1.464kgf/$cm^24, operating flow rate $7\ell/min at\; 40^{\circ}C$. At that time, sericin concentration rejection ratio was 83% respectably. The sericin solution was concentrated from 0.1wt% solution to 0.2 wt % solution during about 2 hrs by the UF filteration membrane system.

A study on the BAC pilot plant in the Duk-san water works (덕산(德山) 정수장(淨水場)에서의 BAC Pilot plant에 관한 연구(硏究))

  • Lee, Sang-Bong;Kim, Dong-Youn;Lim, Jung-A;Lee, Won-Gwon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.2
    • /
    • pp.97-107
    • /
    • 1995
  • Today a conventional water treatment system has many problems. The ozone/GAC process, sometimes termed Biological Activated Carbon(BAC), appeared to be effective for the removal of soluble organic matters in the drinking water. The water quality of Nak-dong river in Pusan, generally shows BDOC 30-40% and NBDOC 60-70%. The pilot plant installed at the Duk-san water works that was been largest treatability(1,650,000ton/day) in Pusan. A experimental water in the pilot plant made use of the water after sand-filteration. Following results are drawn from this study. Initial adsorption velocity($DOC/DOC_o/T$) in the pure adsorption of GAG had a 0.0225, it's velocity changed to 0.006 after ozone added and the optimum ozone dose ranged of $1.4-2.0mgO_3/L$. A experimental water in the pilot plant composed with humic material(78%). Humic material composed with humic acid(20%) and fulvic acid(56%), and it's rate changed to 18 and 50% respectively after ozone added. DOC constantly decreased in the EBCTs and removal efficieny in the 15min of EBCT was 45-50%. It showed the largest removal rate of BDOC in the EBCT 5 and among the season, characteristics of removal varied. The HPC distributed over $10^6-10^7CFU/cm^3$ in the bed depth and among the season, distribution of HPC were differential.

  • PDF