• Title/Summary/Keyword: filter

Search Result 17,439, Processing Time 0.052 seconds

A Smoothing Data Cleaning based on Adaptive Window Sliding for Intelligent RFID Middleware Systems (지능적인 RFID 미들웨어 시스템을 위한 적응형 윈도우 슬라이딩 기반의 유연한 데이터 정제)

  • Shin, DongCheon;Oh, Dongok;Ryu, SeungWan;Park, Seikwon
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.3
    • /
    • pp.1-18
    • /
    • 2014
  • Over the past years RFID/SN has been an elementary technology in a diversity of applications for the ubiquitous environments, especially for Internet of Things. However, one of obstacles for widespread deployment of RFID technology is the inherent unreliability of the RFID data streams by tag readers. In particular, the problem of false readings such as lost readings and mistaken readings needs to be treated by RFID middleware systems because false readings ultimately degrade the quality of application services due to the dirty data delivered by middleware systems. As a result, for the higher quality of services, an RFID middleware system is responsible for intelligently dealing with false readings for the delivery of clean data to the applications in accordance with the tag reading environment. One of popular techniques used to compensate false readings is a sliding window filter. In a sliding window scheme, it is evident that determining optimal window size intelligently is a nontrivial important task in RFID middleware systems in order to reduce false readings, especially in mobile environments. In this paper, for the purpose of reducing false readings by intelligent window adaption, we propose a new adaptive RFID data cleaning scheme based on window sliding for a single tag. Unlike previous works based on a binomial sampling model, we introduce the weight averaging. Our insight starts from the need to differentiate the past readings and the current readings, since the more recent readings may indicate the more accurate tag transitions. Owing to weight averaging, our scheme is expected to dynamically adapt the window size in an efficient manner even for non-homogeneous reading patterns in mobile environments. In addition, we analyze reading patterns in the window and effects of decreased window so that a more accurate and efficient decision on window adaption can be made. With our scheme, we can expect to obtain the ultimate goal that RFID middleware systems can provide applications with more clean data so that they can ensure high quality of intended services.

Optimal Conditions for As(III) Removal by Filtration System Packed with Different Ratio of Iron-Coated Sand and Manganese-Coated Sand (철 및 망간코팅사 충전비를 달리한 여과시스템에서 3가 비소 제거의 최적 조건)

  • Chang, Yoon-Young;Kim, Kwang-Seob;Song, Ki-Hoon;Yang, Jae-Kyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.11
    • /
    • pp.1186-1191
    • /
    • 2006
  • Removal efficiency of As(III) through oxidation and adsorption in column reactors was investigated at different ratios of manganese-coated sand(MCS) and iron-coated sand(ICS) : MCS-alone, ICS-alone and both of ICS and MCS. The breakthrough of arsenic immediately occurred from a column reactor with MCS-alone. However, most of the arsenic present in the effluent was identified as As(V) due to the oxidation of As(III) by MCS. While five-times delayed breakthrough of arsenic was observed from a column reactor with ICS-alone. At a complete breakthrough of arsenic, the removed As(III) was 36.1 mg with 1 kg ICS. To find an optimum ratio of ICS and MCS in the column packed with both ICS and MCS, the removal efficiency of As(III) was investigated at three different ratios of ICS/MCS with a fixed amount of ICS. The breakthrough time of arsenic was quite similar in the different ratios ICS/MCS. However, much slower breakthrough of arsenic was observed as the ratio of ICS/MCS decreased. As the ratio of ICS/MCS decreased the concentration of As(III) in the effluent decreased and then showed below 50 ppb at an equal amount of ICS and MCS, suggesting more efficient oxidation of As(III) by greater amount of MCS. When a complete breakthrough of arsenic occurred, the removed total arsenic with an equal amount of ICS and MCS was 68.5 mg with 1 kg of filter material.

Characteristic Assessment of Heavy Metals in Dusts Collected by the Air Filtration System at Subway Stations in Daegu, Korea (대구지역 지하철역사 공기여과필터 포집먼지에 함유된 중금속성분의 특성평가)

  • Do, Hwa-Seok;Song, Hee-Bong;Shin, Dong-Chan;Kwak, Jin-Hee;Lee, Myoung-Sook;Yoon, Ho-Suk;Kang, Hye-Jung;Phee, Young-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.42-50
    • /
    • 2009
  • Samples of subway dust were collected by the air filter system of 30 subway stations on Daegu subway line 1 in January 2008. Samples were sieved below 100 ${\mu}m$, and 14 elements were analyzed using ICP after acid extraction. Results obtained from the source assessment of trace elements using enrichment factor showed that Ca, Fe, K, Mg, Mn, Na, V were influenced by natural sources such as weathered rock and resuspended soil, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources such as fuel combustion and waste incineration. Concentrations were remarkably higher in components from natural sources than in components from anthropogenic sources. Anthropogenic sources were significantly affected by indoor dusts than outdoor dusts. Results of pollution indices of heavy metals indicated that indoor dusts were more contaminated with heavy metal ions than outdoor dusts. The correlation analysis among trace elements indicated that components were much correlated in the order of natural sources-anthropogenic sources, anthropogenic sources-anthropogenic sources, natural sources-natural sources in both indoor and outdoor dusts. Trace element components of outdoor dusts were largely correlated than those of indoor dusts. In addition, indoor dusts were significantly affected by outdoor dusts rather than depth from the surface or the average daily number of subway passengers.

Isolation and Evaluation of an Antiviral Producing Serratia spp. Strain Gsm01 against Cucumber mosaic virus in Korea (한국에서 CMV에 항바이러스 효과를 나타내는 Serratia spp. Gsm01 균주의 분리 동정 및 효과 검정)

  • Ipper, Nagesh S.;Lee, Seon-Hwa;Suk, Jung-Ki;Shrestha, Anupama;Seo, Dong-Uk;Park, Duck-Hwan;Cho, Jun-Mo;Park, Dong-Sik;Hur, Jang-Hyun;Lim, Chun-Keun
    • The Korean Journal of Pesticide Science
    • /
    • v.10 no.4
    • /
    • pp.344-350
    • /
    • 2006
  • An Antiviral producing bacterial strain was isolated from ginseng root environment in Hongcheon, Kangwon province of Republic of Korea. Identification of this bacterial strain was performed by physiological and biochemical tests along with 16S rRNA analyses. The results revealed that the bacterium was closer to genus Serratia, which was named as Gsm01. The strain was grown in Mannitol-Glutamate-Yeast (MGY) broth for 48 h. The culture was centrifuged and the filtrate obtained was tested for its ability to control Cucumber mosaic virus strain Y (CMV-Y) in greenhouse and field experiments. In the green house experiments, CF was evaluated for its ability to protect local host, Chenopodium amaranticolor and systemic host of CMV, Nicotiana tabacum cv. Xanthi-nc. It was found that, CF treatment reduced viral infection by 98% in local host; C. amaranticolor. The N. tabacum cv. Xanthi-nc plants treated with CF did not show visible viral symptoms 15 days post inoculation (dpi) and remained symptomless throughout the periods of the study. To evaluate effectiveness of CF under field conditions, experiment was carried out in a polyvinyl house. It was observed that, 52% plants were protected from viral diseases compared to non-treated plants, increasing the crop yield. This is the first report showing antiviral activity of a Serratia spp. against CMV.

Growth Inhibition of Diatom, Chaetoceros calcitrans by Marine Bacteria, Shewanella sp. SR-14 - Effects of Marine Bacteria on the Changes of Fatty Acid Composition of Diatoms - (해양세균, Shewanella sp. SR-14에 의한 규조류 Chaetoceros calcitrans의 증식저해 - 해양세균이 규조류의 지방산 조성변화에 미치는 영향 -)

  • KIM Ji Hoe;YOON Ho Dong;PARK Hee Yun;LEE Hee Jung;CHANG Dong Suck
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.1
    • /
    • pp.24-29
    • /
    • 2003
  • In the previous reports, the authors isolated two strains of marine bacteria, Shewanella sp. SR-14, which has Chaetonros sp. growth inhibition activity, and Vibrio alginolyticus, that did not affect growth of the alga. In the present study, fatty acid compositions of diatoms, Chaetoceros calcitrans and Skeletonema costatum, and marine bacteria, Shewanella sp. SR-14 and V. alginolyticus, were analyzed. Changes of fatty acid composition in the diatoms grown with the marine bacteria were also determined. Major fatty acids of Sbewanella sp. SR-14 were 16:1n-7 $(29.4\%)$ and 16:0 $(19.2\%)$ during incubation in peptone broth at $20^{\circ}C$ for 3 days. The compositions of V. alginolyticus detected were 16:0 $(23.7\%),$ 16:1n-7 $(27.7\%)$ and 18:1n-7 $(21.0\%).$ C. calcitrans consisted of 16:1n-7 $(33.3\%),$ 16:0 $(27.1\%)$ and 14:0 $(12.1\%).$ S. costatum mainly contained 16:1n-7 $(28.9\%),$ 16:0 $(21.6\%)$ and 20:5 $(19.8\%).$ When halves of cell numbers of C. calcitrans were moribund cells by Shewanella sp. SR-14, the C. calcitrans and S. costatum simultaneously cultured with the bacteria were harvested by filtration with GE/D glass microfibre filter. In the fatty acid composition of both diatoms, saturated fatty acid contents in both diatoms grown with Shewanella sp. SR-14 were decreased, but unsaturated fatty acid contents were increased. The differences were greater in C. calcitrans than those in S. costatum. During the growth of diatoms with V. alginolyticus, C. calcitrans showed increase of saturated fatty acid contents and decrease of unsaturated fatty acid contents; however, S. costatum did not show sharp difference in fatty acid content. In this study, Shewanella sp. SR-14, which showed growth inhibition activity against C. calcitrans, influenced on the changes of fatty acid contents in the diatom. It was suggested that increased unsaturated fatty acid was synergistically activated algal growth inhibition activity of Shewanella sp. SR-14.

A Dynamic Prefetch Filtering Schemes to Enhance Usefulness Of Cache Memory (캐시 메모리의 유용성을 높이는 동적 선인출 필터링 기법)

  • Chon Young-Suk;Lee Byung-Kwon;Lee Chun-Hee;Kim Suk-Il;Jeon Joong-Nam
    • The KIPS Transactions:PartA
    • /
    • v.13A no.2 s.99
    • /
    • pp.123-136
    • /
    • 2006
  • The prefetching technique is an effective way to reduce the latency caused memory access. However, excessively aggressive prefetch not only leads to cache pollution so as to cancel out the benefits of prefetch but also increase bus traffic leading to overall performance degradation. In this thesis, a prefetch filtering scheme is proposed which dynamically decides whether to commence prefetching by referring a filtering table to reduce the cache pollution due to unnecessary prefetches In this thesis, First, prefetch hashing table 1bitSC filtering scheme(PHT1bSC) has been shown to analyze the lock problem of the conventional scheme, this scheme such as conventional scheme used to be N:1 mapping, but it has the two state to 1bit value of each entries. A complete block address table filtering scheme(CBAT) has been introduced to be used as a reference for the comparative study. A prefetch block address lookup table scheme(PBALT) has been proposed as the main idea of this paper which exhibits the most exact filtering performance. This scheme has a length of the table the same as the PHT1bSC scheme, the contents of each entry have the fields the same as CBAT scheme recently, never referenced data block address has been 1:1 mapping a entry of the filter table. On commonly used prefetch schemes and general benchmarks and multimedia programs simulates change cache parameters. The PBALT scheme compared with no filtering has shown enhanced the greatest 22%, the cache miss ratio has been decreased by 7.9% by virtue of enhanced filtering accuracy compared with conventional PHT2bSC. The MADT of the proposed PBALT scheme has been decreased by 6.1% compared with conventional schemes to reduce the total execution time.

Contributions of Ionic Strength, pH, and Replacing Cations to the Cation Exchange Capacities of Soils (치환양(置換陽) ion의 종류(種類) 및 pH 가 토양(土壤)의 양(陽) ion 치환용량(置換容量)에 미치는 영향(影響))

  • Lim, Hyung-Sik;Kwag, Pan-Ju;Kim, Hee-Joong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.17 no.2
    • /
    • pp.114-124
    • /
    • 1984
  • Various methods for measuring cation exchange capacity (CEC) of soil were compared and the contributions of ionic strength, pH and replacing cations to the CEC were investigated on Kangweon soils (Pyeongchang soils derived from lime stone : Chuncheon, Weonseong soils from alluvium : Cheolweon soils from basalt). The results were as follows : 1. The CEC measuring method using shaker and centrifuge at saturating, washing and replacing precesses, which are common in determining CEC of soils, appeared to be superior to the other methods using column, filter, or Brown method. 2. For all soil samples, the higher the ionic strength, the higher CEC value was obtained with the fewer saturating processes. However, using monovalent saturating ion on Anmi series soil derived from lime stone, the CEC value decreased when the ionic strength and the number of saturating process increased. 3. The CEC value generally increased with increasing pH. But, Chuncheon soil (Gyuam series from alluvium) having higher Al content showed the abrupt increases of CEC from pH 5.5 to pH 7.5. 4. About 70% of CEC of Kangweon soils were attributed to organic matter. 5. In determining CEC of soils, saturating with 0.5M divalent cation solution 2 to 3 times for Pyeongchang and Weonseong soil, 3 to 4 times for Cheolweon soil, and replacing with 0.25M divalent cation solution about 3 times are thought to be recommendable.

  • PDF

A Study of a Non-commercial 3D Planning System, Plunc for Clinical Applicability (비 상업용 3차원 치료계획시스템인 Plunc의 임상적용 가능성에 대한 연구)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.71-79
    • /
    • 1998
  • Purpose : The objective of this study is to introduce our installation of a non-commercial 3D Planning system, Plunc and confirm it's clinical applicability in various treatment situations. Materials and Methods : We obtained source codes of Plunc, offered by University of North Carolina and installed them on a Pentium Pro 200MHz (128MB RAM, Millenium VGA) with Linux operating system. To examine accuracy of dose distributions calculated by Plunc, we input beam data of 6MV Photon of our linear accelerator(Siemens MXE 6740) including tissue-maximum ratio, scatter-maximum ratio, attenuation coefficients and shapes of wedge filters. After then, we compared values of dose distributions(Percent depth dose; PDD, dose profiles with and without wedge filters, oblique incident beam, and dose distributions under air-gap) calculated by Plunc with measured values. Results : Plunc operated in almost real time except spending about 10 seconds in full volume dose distribution and dose-volume histogram(DVH) on the PC described above. As compared with measurements for irradiations of 90-cm 550 and 10-cm depth isocenter, the PDD curves calculated by Plunc did not exceed $1\%$ of inaccuracies except buildup region. For dose profiles with and without wedge filter, the calculated ones are accurate within $2\%$ except low-dose region outside irradiations where Plunc showed $5\%$ of dose reduction. For the oblique incident beam, it showed a good agreement except low dose region below $30\%$ of isocenter dose. In the case of dose distribution under air-gap, there was $5\%$ errors of the central-axis dose. Conclusion : By comparing photon dose calculations using the Plunc with measurements, we confirmed that Plunc showed acceptable accuracies about $2-5\%$ in typical treatment situations which was comparable to commercial planning systems using correction-based a1gorithms. Plunc does not have a function for electron beam planning up to the present. However, it is possible to implement electron dose calculation modules or more accurate photon dose calculation into the Plunc system. Plunc is shown to be useful to clear many limitations of 2D planning systems in clinics where a commercial 3D planning system is not available.

  • PDF

Investigation and Risk Assessment of Asbestos-Containing Materials used in Buildings (건축물에 사용된 석면함유물질(ACMs)의 조사 및 위해성 평가)

  • Kim, Hong-Kwan;Chon, Young Woo;Roh, Young Man;Hong, Seung-Han;Kim, Chi-Nyon;Lee, Ik-Mo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Objectives: The objectives of this study are to research the usage characteristics of asbestos-containing building materials and to conduct exposure risk assessment by applying no. 2016-230 "Methods of Risk Assessment of Asbestos-Containing Buildings" from the Ministry of Environment. Methods: One hundred buildings located in the Seoul and Gyeonggi-Incheon area were chosen, with 29 in Seoul, 20 in Incheon, and 51 in Gyeonggi-do Province. The year of construction was divided between three buildings in the 1970s, 11 buildings in the 1980s, 42 buildings in the 1990s, and 44 buildings in the 2000s. The bulk samples were analyzed by using a polarizing microscope after a pre-process using a stereomicroscope in a hood with an HEPA filter. This study defined ACMs(asbestos-containing materials) as asbestos when the content percentage was over 1% in the analysis result. Methods and standards of risk assessment of asbestos-containing building materials were conducted by refering to no. 2016-230 "Method of Risk Assessment of Asbestos-Containing Buildings" from the Ministry of Environment. The risk of exposure to ACMs was rated by a score based on three categories(high, middle, low risk of asbestos exposure). Results: In this study, 30 of the 100 buildings and 36 of the 416 bulk samples(8.6%) were found to have had asbestos. Asbestos was detected at a high rate, in 18 out of 42, in buildings constructed in the 1990s and at the lowest rate(7 out of 44) for buildings constructed in the 2000s. As a result of the evaluation according to no. 2016-230 "Method of Risk Assessment of Asbestos-Containing Buildings" of the Ministry of Environment, the risk assessment level of two asbestos-containing building materials was found to be "Medium", and 28 buildings materials were found to be at the "Low" level. Conclusion: As asbestos is regulated by the government, it is required to conduct active management and implemention by introducing methods of risk assessment of asbestos exposure that are supported by data from various situations. In the case of buildings owned by individuals, building owners should be aware of the risk of exposure to asbestos.

Bactericidal Efficacy of a Fumigation Disinfectant with Ortho-phenylphenol as an Active Ingredient Against Pseudomonas Aeruginosa and Enterococcus Hirae (Ortho-phenylphenol을 주성분을 하는 훈증소독제의 Pseudomonas aeruginosa와 Enterococcus hirae에 대한 살균효과)

  • Cha, Chun-Nam;Park, Eun-Kee;Kim, Yongpal;Yu, Eun-Ah;Yoo, Chang-Yeol;Hong, Il-Hwa;Kim, Suk;Lee, Hu-Jang
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.1
    • /
    • pp.60-66
    • /
    • 2014
  • This test was performed to evaluate the bactericidal efficacy of a fumigation disinfectant containing 20% ortho-phenylphenol against Pseudomonas aeruginosa (P. aeruginosa) and Enterococcus hirae (E. hirae). In preliminary tests, P. aeruginosa and E. hirae working culture suspension number (N value) were $2.8{\times}10^8$ and $4.0{\times}10^8CFU/mL$, respectively. And all the colony numbers on the carriers exposed to the fumigant (n1, n2, n3) were higher than 0.5N1 (the number of bacterial test suspentions by pour plate method), 0.5N2 (the number of bacterial test suspentions by filter membrane method) and 0.5N1, respectively. In addition, the mean number of P. aeruginosa and E. hirae recovered on the control-carriers (T value) was $2.8{\times}10^8$ and $3.4{\times}10^6CFU/mL$, respectively. In the bactericidal effect of the fumigant, the reduction number of $2.8{\times}10^8$ (d value) was 6.46 and 5.19 logCFU/mL, respectively. According to the French standard for the fumigant, the d value for the effective bactericidal fumigant should be over than 5 logCFU/mL. With the results from this study, the fumigation disinfectant containing 20% ortho-phenylphenol has an effective bactericidal activity, then the fumigant can be applied to disinfect food materials and kitchen appliances contaminated with the pathogenic bacteria.