• 제목/요약/키워드: film-screen radiography

검색결과 51건 처리시간 0.025초

입자침전법을 이용한 광도전체 필름의 X선 반응 특성에 관한 연구

  • 최치원;강상식;조성호;권철;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.176-176
    • /
    • 2007
  • Flat-panel direct conversion detectors used in compound substance of semiconductor are being studied for digital x-ray imaging. Recently, such detectors are deposited by physical vapor deposition(PVD) generally. But, most of materials (HgI2, PbI2, TlBr, PbO) deposited by PVD have shown difficult fabrication and instability for large area x-ray imaging. Consequently, in this paper, we propose applicable potentialities for screen printing method that is coated on a substrate easily. It is compared to electrical properties among semiconductors such as $HgI_2$, $PbI_2$, PbO, HgBrI, InI, and $TlPbI_3$ under investigation for direct conversion detectors. Each film detector consists of an ~25 to $35\;{\mu}m$ thick layer of semiconductor and was coated onto the substrate. Substrates of $2cm{\times}2cm$ have been used to evaluate performance of semiconductor radiation detectors. Dark current, sensitivity and physics properties were measured. Leakage current of $HgI_2$ as low as $9pA/mm^2$ at the operation bias voltage of ${\sim}1V/{\mu}m$ was observed. Such a value is not better than PVD process, but it is easy to be fabricated in high quality for large area x-ray Imaging. Our future efforts will concentrate on optimization of growth of film thickness that is coated onto a-Si TFT array.

  • PDF

Digital Radiography 환경하에서 일반촬영시 적정 노출조건에 따른 CR과 DDR의 Image Quality 비교 (The Comparison of Image Quality between Computed Radiography(CR) and Direct Digital Radiography(DDR) which Follows the Proper Exposure Conditions in General Photographing under the Digital Radiography(DR))

  • 김진배;강충환;강성진;박수인;박종원;김영수;김승식
    • 대한디지털의료영상학회논문지
    • /
    • 제5권1호
    • /
    • pp.64-77
    • /
    • 2002
  • DR은 방사선과 뿐만 아니라 병원전체의 생산성 및 업무의 효율성에서 중요한 요소로 자리잡아가고 있다. DR환경은 CR보다 다양한 Parameter를 가지고 있어 양질의 의료서비스 제공이 가능하다. 현재 각 병원의 방사선과는 Film-Screen system에서 Full-PACS를 통한 DR 환경으로 변화하고 있다. Full-PACS를 사용하고 있는 본원에서는 DR환경에서의 일반촬영 System중 CR과 DDR의 최적노출조건과 그에 따른 Image quality가 어떻게 표현되는 지 알아보고자 본 연구에 임하게 되었다. 본 실험을 통하여 CR과 DDR의 Image quality는 같은 노출조건 하에서는 DDR이 더욱 우수하다는 것을 알 수 있었다. 그리고 DDR system에서도 AEC를 사용했을 때의 Image에 대한 점수가 사용하지 않았을 때보다 조금 더 높은 것을 알 수 있다. 특히 Skull, Chest부분에서는 DDR의 AEC기능이 Image quality를 향상시키는데 유용함을 간접적으로 알 수 있었다. (AEC기능이란 피사체를 통과한 X선을 Detector내에 있는 Ion chamber를 이용하여 전리전류를 검출하는 기구로서 적정농도 도달 시 X선의 조사를 제어하도록 되어있다.) 이 기능은 다양한 피사체의 두께에 따른 노출조건을 고려하지 않아도 적정농도를 나타낼 수 있기 때문에 보다 손쉬운 촬영이 이루어질 수 있다. 이 실험결과로 좋은 Image quality를 얻기 위해서는 적절한 노출조건의 선정이 중요함을 알 수 있었다. 앞으로도 무한한 발전 가능성이 있는 DDR system에 대한 연구가 좀 더 필요하겠다.

  • PDF

IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징 (Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0)

  • 김현지;김정민;최인석;윤용수;서덕남;김정수;김대영;박성용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권1호
    • /
    • pp.1-10
    • /
    • 2013
  • IEC 규격은 유럽, 일본 등 해외 여러 나라에서 자국의 규격으로서 이용되고 있으며, 우리나라에서는 현재 산업표준인 KS 형태와 더불어 강제성을 갖는 식품의약품안전청 고시로서도 발행되고 있다. 전자의료기기에 관한 IEC 규격인 IEC 60601 시리즈의 공통규격(IEC 60601-1:2005)이 3판으로 개정됨에 따라, 보조규격과 개별규격 또한 그에 맞추어 제 개정이 필요하다. IEC 규격의 변화 동향을 파악하는 것은 국내 의료기기 제조 수입업체 및 시험검사기관에서 매우 중요하다. 따라서 본 연구에서는, 진단용X선기기와 관련한 3개 규격 IEC 60601-2-44(CT의 기본안전과 필수성능에 관한 규격), IEC 60601-2-45(유방촬영용X선장치의 기본안전과 필수성능에 관한 규격), IEC 60601-2-54(진단용 X선장치의 기본안전과 필수성능에 관한 개별규격)에 대하여 IEC 60601-1의 3판에 맞추어 제 개정된 최신판의 동향 및 특징을 살펴보고자 하였다. 또한 현행 식품의약품안전청 고시가 IEC 60601-1의 2판이 적용된 개별규격을 참고로 하고 있어, 현행 식품의약품안전청 고시와 대비하여 그 특징을 살펴보았다. IEC 60601-1의 3판이 적용된 진단용X선장치 외 2개의 IEC 개별규격의 특징은 다음과 같다. 1) 기계적 위해요인, 특히 움직이는 부분에 대한 내용이 강화되었다. 2) 환자 선량을 표시 및 기록하도록 명시하고 있다. 3) 잠재적인 위험요소에 대해 체계적으로 관리가 가능한 위험관리 프로세스를 도입하고 있다. 4) 과거 Film-Screen System과 더불어 DR system(digital radiography system)에 대해서도 적용하고 있다. 현재 IEC 60601-1의 3판이 적용된 개별규격이 식품의약품안전청 고시로 개정될 예정이므로, 국내 시험 검사기관 및 의료기기 제조 수입업체 등에 유용한 자료가 되기를 기대한다.

디지털 방사선의학에서의 조사선량 설정과 인지에 대한 실태 - 대구 경북지역을 중심으로 - (A Study on the Exposure Parameter and the Patient Dose for Digital Radiography System in Dae Goo)

  • 조광호;강영한;김부순
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권2호
    • /
    • pp.177-182
    • /
    • 2008
  • 디지털 시스템이 가지는 장점인 영상판 검출기의 반응 범위(dynamic range)가 상당히 넓다는 것은 필름/증감지 시스템보다 더 높은 수준의 노광 관용도를 갖기에 재촬영이 줄어들고 영상관리에 효율적이지만, 조사조건의 설정범위가 상당히 넓어 필름/증감지 시스템의 엄격한 조사조건보다 더 많은 조사선량이 환자에게 노출 될 수도 있다. 본 연구는 디지털 시스템 하에서 일반촬영 시 방사선사 개인 별 조사선량에 대한 인식과 행위실태를 파악하여 환자피폭선량을 감소시킬 수 있는 방안을 마련하고, 방사선 선량관리의 중요성을 새로이 인식하고자 하였다. 디지털 시스템 하에서 근무 중인 방사선사의 조사조건 설정과 환자피폭선량 인지 실태를 파악해 본 결과 환자의 체형이나 상태, 촬영부위에 따라 최적의 조사선량을 적용하기 보다는 영상의 농도와 업무의 편의성에 따라 조사조건이 설정되고 있었다. 디지털 시스템이 도입되며 검출기의 반응 범위가 필름/스크린 시스템보다 넓어짐에 따라 조사조건 설정에 대해 관심이 소홀한 경향이 있었다. 따라서 디지털 방사선 시스템 하에서 환자 피폭선량의 감소를 위해 최적의 조사조건으로 영상을 얻어야 할 것이다. 또한 조사선량을 최소로 하고 환자 피폭선량을 줄이기 위해 업무 습관과 인식을 새로이 할 필요성이 있고, 지속적인 관심과 주기적인 교육 및 점검, 다양한 교육 기회제공 등이 필요하다고 본다.

  • PDF

고관전압 흉부촬영의 가상결절을 이용한 ROC평가 (Evaluation of ROC Curve in High Kilovoltage Technique Using Simulated Nodules on Chest)

  • 안진신;장명미;정경모;정환;임정기;김종효
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제15권2호
    • /
    • pp.25-30
    • /
    • 1992
  • With transmitted dose through chest which has the problem of wide variations in absorption, simple film/screen combination method makes it diffucult to image lung field, mediastinum and retrocardiac areas. In order to overcome this, it is very common to use the high kilovoltage technique in diminishing the differences between high and low contrast. We have been adopting this method at department of diagnostic radiology, Seoul National University Hospital. To compare the image of it with that of low kilovoltage technique, we did radiographic tests using beans on the skin. We marked off into three anatomical categories such as lungs, mediastinum and near diaphragm, then attached a bean on a marked area at random. In order to compare with high and low, we took a radiography of high($120{\sim}140\;kVp$) and low($70{\sim}90\;kVp$) kilovoltage tehchniques, respectively at the same time. We have done experiments 320 cases. We evaluated the results of test in response to sensitivity(true positive) and specificity(true negative). In evaluating, we gave them points from 1 to 5 according to true or false. With given points by a radiologist having much experiences, we could acquire the percentage of sensitivity and specificity. The percentage made us to get the schematic table of ROC curve of those two methods. Consequently, high kilovoltage technique appeared 18% better than low kilovoltage technique for detecting beans with our apparatus.

  • PDF

일반 X-선 촬영에서의 환자피폭선량에 관한 조사연구 (Patient Dose for Diagnostic Radiological Procedures in Korea)

  • 김유현;최종학;김성수;이창엽;이영배;김철민
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.59-63
    • /
    • 2004
  • IAEA에서 제공한 선량기준은 서양 사람을 기준으로 개발된 것이어서 우리 한국 사람에게는 맞지 않고, 상대적으로 우리나라의 환자선량은 적으리라 예상된다. 따라서 선량기준을 따로 개발해야할 필요가 있다. 그래서 본 연구팀은 병원협회에 등록되어 있는 종합병원 278개를 대상으로 환자 피폭에 대한 설문조사를 실시하였다. 설문회수율은 57.9%였으며 각 병원에서의 촬영조건을 기초로 NDD법을 이용하여 환자 피폭선량을 계산하였고 설문지를 분석한 결과를 보고한다.

  • PDF

일부지역 유방촬영장치의 현황 및 특성에 관한 연구 (A Study on the Actual Conditions and Characteristics of Mammographic Units in Some Area)

  • 박진영;백성민
    • 한국방사선학회논문지
    • /
    • 제6권2호
    • /
    • pp.121-127
    • /
    • 2012
  • 일부지역의 전체 유방촬영장치는 205대가 설치 사용되고 있었으며 종합병원에는 36대, 병원 53대, 의원은 116대가 사용되고 있었다. 즉, 의원의 비중이 전체의 50%를 차지하고 있음을 알 수가 있었다. 영상획득방법 별에서는 필름 스크린(film screen)이 131대, 컴퓨터 방사선촬영장치(computed radipgraphy)가 67대, 디지털 방사선촬영장치(digital radiography)가 7대 순으로 나타났다. 현재까지는 주로 필름 스크린 시스템이 이용되고 있었다. target/filter의 재료는 대부분 Mo/Mo이 사용되었으며(66%), 그 다음으로는 Mo/Rh이 사용되고 있었다(25%). 초점의 크기는 소초점용은 0.1 mm, 대초점으로는 0.3 mm를 주로 사용하고 있었다.

흉부X선촬영시(胸部X線撮影時) 산란선(散亂線)이 화질(畵質)과 피폭선량(被曝線量)에 미치는 영향(影響) (Effects of the Scattered Radiation on Image Quality and Exposure Dose in Chest Radiography)

  • 반야유;임태랑;석전유치;전전미향;앵정달야;이만구;안봉선;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제16권2호
    • /
    • pp.27-38
    • /
    • 1993
  • To investigate relationships between image guality and exposure dose, Chest X-ray films were evaluated for the following points:how much scattered radiation can affect reduction in image quality and can be permissible diagnostically? For this purpose using a test charts and Burger's phantoms. The visual evaluation of their X-ray films and the measurements of scattered radiation were carried out. The dose of scattered radiation ranging from 20 to 25% was found to be for nothing in any diagnostic obstacle. In this range, surface doses were low of 17, 21, and $25{\mu}Gy$ for The thickness of the chest of 15, 20 and 25 cm respectively. Comparison of these high voltage X-ray films with low voltage ones showed a surface dose rate of 1:11.7. Therefore, X-ray quality, photosensitive materials(film and screen) and grid should be selected very carefully for the purpose of reduction in exposure dose.

  • PDF

머리부 전후방향촬영 시 방사선피폭선량 저감을 위한 부가여과판에 대한 연구 (A Study on Added Filters for Reduction of Radiation Exposure Dose in Skull A-P Projection)

  • 이초희;임창선
    • 한국산학기술학회논문지
    • /
    • 제12권7호
    • /
    • pp.3117-3122
    • /
    • 2011
  • 머리부 전후방향촬영은 종래의 증감지-필름 방사선촬영보다 디지털방사선촬영 시 입사표면선량(ESD)이 훨씬 높다. 따라서 본 연구의 목적은 부가필터를 사용하여 환자의 피폭선량을 줄이기 위한 것이다. 본 연구에서는 머리부 팬톰을 이용하여 머리부 전후방향촬영 시 부가여과판의 두께에 따른 선량 감소효과를 알아보았고, 동시에 부가여과판 사용에 따른 영상의 질적 저하의 평가를 위한 실험을 진행하였다. 선량측정은 머리부 팬톰을 머리부 전후방향촬영자 세로 위치시켜 입사표면선량과 투과선량을 0.1 mmAl으로부터 0.5 mmCu+2.0 mmAl까지 16종류의 부가여과판을 바꾸어 가며 측정하였다. 영상의 화질 평가를 위해서 총 17매의 영상을 촬영하였고 촬영된 영상은 영상의학과 전문의에게 평가를 의뢰하였다. 그 결과 부가여과판 중 0.2 mmCu+1.0 mmAl의 복합여과판을 사용한 부가여과판까지 진단적 가치가 있는 영상을 얻었고, 이 때 머리부 팬톰에 입사표면선량은 약 0.6 mGy이었다. 이 값은 국제원자력기구(IAEA)에서 권고하고 있는 머리부 후전방향촬영 시 입사표면선량 5 mGy의 12%에 불과하였다. 따라서 검사부위에 따라 적정한 부가여과판의 사용으로 환자의 피폭선량을 상당히 감소시키는 효과를 얻을 수 있다.

산란선 제거를 위한 신개념 간접 평판형 검출기의 임상적용을 위한 최적 구조 : 입사 X선 각도에 따른 성능평가 (An Optimal Structure of a Novel Flat Panel Detector to Reduce Scatter Radiation for Clinical Usage: Performance Evaluation with Various Angle of Incident X-ray)

  • 윤용수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.533-542
    • /
    • 2017
  • 진단용 X선 영상에서 산란선은 화질을 열화시키는 주요한 원인이다. X선 장치는 필름/스크린을 사용한 아날로그 시스템부터 Imaging plate (IP) 및 평판 검출기(Flat panel detector; FPD)를 사용한 디지털 시스템으로 바뀌어 가고 있다. 그러나 산란 X선 제거를 위한 Grid는 아날로그 시대에 사용됐던 구조부터 큰 변화가 없다. 본 논문에서는 선행연구에서 고안된 산란선 제거율을 향상시키기 위한 간접변환형 평판검출기의 새로운 구조를 다양한 입사 X선을 사용하는 임상현장에서의 활용 가능성을 검토했다. 일반적으로 FPD는 3개의 층으로 구성되어 있다. 신호를 검출하는 화소와 화소 사이에는 전압을 거는 voltage line이나 데이터를 전달하는 data line과 같은 X선 불감영역이 존재한다. 선행연구에서는 이 불감영역에 정확히 맞추어 방사선 불 투과성의 납을 그물 모양으로 substrate layer에 삽입함으로서 검출기 자체가 산란선 제거 효과가 있도록 설계하였다. 새로운 구조의 임상 유용성을 평가하기 위해, 삽입된 그물 모양의 납을 입사 X선에 대해 가로, 세로성분으로 나누어 각각의 성능을 확인하였으며, 동시에 납의 높이를 변화시켜 납 높이가 성능에 미치는 영향을 영상 대조도와 grid 노출 인자를 통해 검토했다. 검출기면에 대해 대각선으로 입사한 X선($0^{\circ}$, $15^{\circ}$, $30^{\circ}$)에 대해서, 입사 X선에 대해 평행한 가로성분이 세로 성분에 비해 높은 영상 대조도와 낮은 그리드 노출 인자를 나타냈으며, 세로성분의 납 높이가 높을수록 본 연구에서 고안한 검출기에 악영향을 미치는 것을 확인했다. 그러므로 본 연구에서 고안한 새로운 FPD 시스템은 FPD의 구조를 방사선검사 조건과 목적에 맞추어 최적화함으로써 임상 의료현장에서의 사용 가능성이 확인되었다.