• Title/Summary/Keyword: film-screen radiography

검색결과 51건 처리시간 0.024초

Computed Radiography 환경에서의 REPEAT 유형변화에 대한 고찰

  • 안미섭;장광현;문희석;정환
    • 대한디지털의료영상학회논문지
    • /
    • 제3권1호
    • /
    • pp.52-58
    • /
    • 1997
  • Before entering 21st Century, modern medical science is requiring more precise display which is highly estimated in diagnostic value as radial science technology is achieving sharp development. And it is also trying to contribute to improve national health and to offer better service by reducing radial exposure. General projection and Fluoroscopy which are most difficult to be displayed in digital tend to change their way ; from analog to digital with development of Electronic Engineering and Computer Technology, Introducing to CR system in 1994, SMC have displayed General projection and Fluoroscopy 100% in digital using CR system. This study searched differences between repeat rate, repeat type in the exam using Film/Screen and those in the exam using CR system. According to the analysis of repeat types and repeat rate of Film which was reused by using CR system in general projection room and Fluoroscopy room of SMC, we found that total 192,813 films were used and 2,097 films, 1.09% of total were reused. However, actual repeat covers 0.76% to 1,461 sheets with the exception of 636sheets. As above, display process using CR system is 0.76% much lower than general repeat rate 2$\sim$4% of Film/Screen exam. Besides decreased under/over exposure, it is appeared that position failure rate in repeat rate 0.76% covers relatively high 31%. Noticing that repeat caused unskilled devices handing was found many times, sufficient understanding seems to be required to reduce repeat.

  • PDF

컴퓨터 방사선영상에서 고 관전압 기법을 이용한 안구 입사표면선량 감소에 관한 연구 (A Study on Reducing of Entrance Surface Dose with the Eye in the Computed Radiography by Using High Kilo Voltage Peak Technique)

  • 성열훈;임재동
    • 대한안전경영과학회지
    • /
    • 제13권2호
    • /
    • pp.91-96
    • /
    • 2011
  • The purpose of this study was to minimize of entrance surface dose (ESD) at the eye using high kVp technique in the computed radiography. We used REX-650R (Listem, Korea) general X-ray unit, and external detector with ESD dosimeter of Piranha 657 (RTI Electronics, Sweden). We used head of the whole body phantom. The total 64 images of X-ray anterior-posterior of skull were acquired using the film/screen (F/S) method and the digital of computed radiography method. The three radiology professor of more 10 years of clinical career evaluated a X-rays images in the same space by 5-point scale. The external detector was performed measurement of ESD of three times by same condition on the eye of the head phantom. The good image quality in the F/S method (90 kVp, 2.5 mAs) showed at the minimized ESD of 0.310 ${\pm}$ 0.001 mGy. the good image quality in the computed radiography method (90 kVp, 2.0 mAs) showed at the minimized ESD of 0.180 ${\pm}$ 0.002 mGy (P = 0.002). Finally the radiation dose could reduced about 50% in the computed radiography method more than the F/S method. In addition the eye entrance surface dose using high kVp technique with the computed radiography was reduced 92% more than conventional technique (F/S method).

Computed Radiography 영상에서 Parameter에 의한 Artifact 원인과 해결방안 (Cause and Solution of an Artifact Generation by Parameter in Computed Radiography System)

  • 동경래;최준구;홍성일
    • 한국콘텐츠학회논문지
    • /
    • 제9권5호
    • /
    • pp.145-155
    • /
    • 2009
  • CR방식의 도입으로 인해 많은 장점을 가지게 되었으나 기존의 Film/Screen방식에서 발생되지 않았던 Artifact가 새롭게 발생하였다. 따라서 본 논문에서는 광주에 위치한 일개 종합병원에서 획득한 CR 영상 중 Artifact가 발생한 경우를 3가지로 나누어 측정하였다. 시간 지연과 농도변화에 의한 Artifact는 시간이 경과할수록 자연방사선에 의한 영향으로 1일보다 5일후에 67%의 농도가 증가 되었으며 잠상퇴행에 의한 Artifact는 즉시보다 10시간 후의 빛의 방출도가 33%감소하여 시판이 경과할수록 영상의 질이 저하되었다. 술자에 의한 Artifact는 Collimation에 의한 Artifact가 53%, 기기에 의한 Artifact는 Guiding plate, Suction cup으로 인한 Artifact가 65%로 가장 많이 발생되는 것으로 나타났다. 따라서 Artifact에 대한 정확한 인식을 정기적인 점검을 통해 해결방안을 모색한다면 영상의 질 및 진료의 만족도를 높여 갈 수 있을 것이다.

문화재 방사선 조사에서 발생하는 산란 방사선의 특성과 영향 (Characteristics and Influence of Scattering Radiation in Cultural Heritage Radiography)

  • 송정일;박영환;유지혜
    • 보존과학회지
    • /
    • 제34권6호
    • /
    • pp.539-548
    • /
    • 2018
  • 본 연구는 문화재 방사선 조사에서 고려하지 않았던 산란 방사선의 영향을 확인하기 위해 관전압 (kVp)과 필름-바닥 거리(film-floor-distance: FFD) 납스크린 배치를 달리하여 평가하였다. 연구결과, 실험시편의 투과농도와 산란 방사선의 투과 농도는 관전압에 따라 증가되었다. 실험시편의 투과농도는 평균 1.4 D의 편차를 보이며, 60 kVp에서 0.17 D, 160 kVp에서 1.54 D, 220 kVp에서 2.97 D로 확인되었다. 산란 방사선의 평균 투과농도는 60 kVp에서 0.10 D, 160 kVp에서 0.40 D, 220 kVp에서 0.46 D로 확인되었다. FFD 거리가 바닥면과 멀어질수록 관전압(60 kVp-160 kVp)구간의 경우 투과농도 (D)가 커지는 경향을 보였으나, 고전압(160 kVp-220 kVp)구간은 FFD 거리 증가에 따른 투과농도 변화가 확인되지 않았다. 납스크린 없는 조건과 바닥면(floor)을 납스크린으로 대체한 경우는 FFD 50 mm, 100 mm, 200 mm 거리에서 산란 방사선이 확인되었고, FFD 0 mm 거리는 확인되지 않았다. 식별률은 관전압 160 kVp에서 FFD에 따라 2.08~2.67% 범위이며, 관전압 220 kVp에서는 2.67~3.33% 범위로 측정되었다.

Computed Radiography 시스템에 $^{192}Ir$$^{75}Se$ 동위원소를 적용하여 촬영한 비파괴검사 영상 비교 (Comparison of Non-Destructive Testing Images using $^{192}Ir$ and $^{75}Se$ with Computed Radiography System)

  • 강상묵;최창일;이승규;박상기;김용균
    • Journal of Radiation Protection and Research
    • /
    • 제35권1호
    • /
    • pp.26-33
    • /
    • 2010
  • 비파괴검사 분야의 방사선 검사(RT) 방식은 image plate (IP)를 사용한 Computed Radiography(CR) 영상시스템의 도입에 따라 필름 방식의 아날로그 영상이 점차 디지털 영상으로 교체되고 있다. 비파괴검사에서 결함을 효과적으로 검출할 수 있는 영상의 품질은 촬영 조건, 영상획득매체, 사용 선원의 종류 및 촬영 거리, 검사체 두께등이 영향을 미친다. 본 논문에서는 비파괴 검사 분야에 적용할 수 있는 감마선원의 기본 특성을 조사하였고, FUJI사에서 개발한 CR 영상 시스템에 $^{75}Se$, $^{192}Ir$ 동위원소를 적용하여 영상을 획득하였다. 획득된 영상의 gray scale을 이미지 소프트웨어를 통해 추출한 후에 대조도 및 신호대잡음비를 계산하고 비교 분석하였다. 또한 투과도계를 이용한 비교 영상을 통하여 식별도를 분석하였다.

복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향 (Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography)

  • 김유현;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

흉부X선촬영(胸部X線撮影)에 있어서 피폭선량(被曝線量)의 저감(低減)에 관(關)한 연구(硏究) (A Study on the Chest Radiography for Reducing Exposure Dose)

  • 이만구;윤한식;이종석;이선숙;임태랑;석전유치;전전미향;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제19권1호
    • /
    • pp.41-49
    • /
    • 1996
  • We have been used super sensitive screen/film system which is thought to be the limit of sensitivity, however, we think this method is not satisfactory. As a general radiographic rule, reduction of exposure is inconsistent with improvement of image quality, but it is necessary to challenge this rule to get better method. We tried air gap method for minimal diffuse lung shadow which is difficult to find out by our routine method. As a result, air gap method with super sensitive screen/film system(SRO 1000/TMH) showed lower exposure dose, 50% of our routine system(SRO 750/SRH with grid), and better image quality for pulmonary pattern in the lower lung field.

  • PDF

디지털 방사선촬영 환경에서 선량의 최적화 및 영상품질에 대한 연구 (Research for The Environmental Optimization of Dose and Image quality in Digital Radiography)

  • 이광재;김민기;이종웅;김호철
    • 전자공학회논문지
    • /
    • 제50권2호
    • /
    • pp.203-209
    • /
    • 2013
  • Digital Radiography(DR)는 film/screen(F/S)과 비교하여 넓은 계조와 높은 Detective Quantum Efficiency(DQE), Modulation Transfer function(MTF)를 바탕으로 화질의 개선과 저 선량으로 검사가 가능할 것으로 예상됐지만 기대와는 다르게 과노출이 Signal to Noise Ratio(SNR)향상을 가져 오면서 환자 피폭선량의 증가를 가져오게 되었으며 이는 Dose Creep이라는 개념으로 설명 된다. DR에서의 선량 증가 이유는 F/S의 촬영에서 사용했던 관전압(kVp)을 고정 적용하여 Auto Exposure Control(AEC)를 사용하기 때문에 과노출을 유발 할 수 있다. 이에 본 논문은 DR에서 적합한 일반촬영 방법을 제안하고자 관전압이 대조도에 주는 영향, 관전류(mA)변화에 따른 MTF 측정, 머리 모형을 촬영한 영상의 Peak Signal to Noise Ratio(PSNR) 측정을 통해 정량적 평가를 시행 하였다. 그 결과 관전압에 의한 대조도 변화는 후보정 이후 개선이 가능하며, 관전류에 의한 MTF 측정 결과 50%영역은 1.41~1.39 lp/mm, 10% 영역은 3.19~2.8 lp/mm로 관전류 변화에 따른 초점크기 변화는 영상의 해상력에 영향을 주지 않는다. 영상의 PSNR측정 결과는 관전압과 관전류가 증가 하여도 90kVp를 제외하고 30dB 이상으로 시각에 의한 영상의 차이를 인지하기 어렵다. 실험결과를 바탕으로 디지털 일반촬영에서 관전압은 80kVp 이상 100kVp이하, 관전류는 선예도와 상관 관계가 없으므로 선량과 조사시간을 단축 시킬 수 있는 방향으로 사용하기를 제안한다.

비대칭(非對稱) 필름-스크린 시스템에 관한 검토(檢討) (Evaluation of Asymetric Film-Screen System)

  • 허준;김정민;이선숙;이인자;최종학;김성수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제16권1호
    • /
    • pp.57-65
    • /
    • 1993
  • Asymetric system have been introduced in these years by KODAK company nam of Insight system for the purpose of improve the chest image. We have had a problem of chest radiology that it is very difficult to visualize the lung field and modiastinal region at one shot. That's why we are the RT using the technique of high voltage hard quality radiography in chest radiography. Also it is known the c-type wide latitude film can lift up the density of mediastinal structures. Authors investigated the photographic characteristics and physical structure of Insight system. Method 1. Investigated the structure of Emulsion layer. Calculated the particle size of Insight system using SEM(Scanning Electron Microscope). 2. Photographic characteristics has been compared the Insight system with the ortho KM/MG combination in $60{\sim}120kV$ range. Results 1. The particle size of backside film were investigated about 2 times larger that of front side film. 2. The front and backscreen's thickness ratio was detected 1 : 3.87, that the backscreen's thickness was thicker than frontscreen. 3. At the view point of photographic characteristics the frontside of insight system make up the contrast, backside make up the density at low exposure lesion.

  • PDF

디지털 방사선영상에서 고스팅 아티팩트 (Ghosting Artifacts in Digital Radiography)

  • 정원희;천권수
    • 한국방사선학회논문지
    • /
    • 제8권7호
    • /
    • pp.377-382
    • /
    • 2014
  • 방사선 임상 관련 분야에서 컴퓨터의 사용으로 인해 카세트 사용에서는 볼 수 없는 아티팩트가 만들어지고 있다. 고스팅 아티팩트는 평판형 박막 트랜지스터(Flat Panel Thin-Film Transistor) 배열 검출기를 사용할 때 발생될 수 있다. 특히 고선량의 방사선을 고대조도의 물질에 노출시킨 영상을 획득한 후, 바로 저선량의 조사가 이루어진 영상이 획득될 때 고스팅 아티팩트가 발생할 수 있다. 본 실험에서 고스팅 아티팩트가 육안 관찰시 3분에서 사라지는 것을 확인할 수 있었으며 정량적 분석으로는 대략 6분에서 없어지는 것을 확인할 수 있었다. 또한 이 아티팩트는 관전류보다는 관전압의 영향을 더 받는다는 사실과 노출에 의한 포획전하의 방출이 아닌 시간에 의해 포획전하가 소멸된다는 사실을 실험을 통해 검증할 수 있었다.