• Title/Summary/Keyword: film-based system

Search Result 742, Processing Time 0.035 seconds

Verification of Skin Dose in Tomotherapy Using the Developed Phantom for Image Based Radiation Treatment System (영상 기반 치료 장비용 팬톰을 이용한 토모테라피 피부 선량 검증)

  • Park, Ji-Yeon;Chang, Ji-Na;Oh, Seung-Jong;Kang, Dae-Gyu;Jung, Won-Gyun;Lee, Jeong-Woo;Jang, Hong-Suk;Kim, Hoi-Nam;Park, Hae-Jin;Kim, Sung-Hwan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.88-96
    • /
    • 2009
  • Radiation treatment for skin cancer has recently increased in tomotherapy. It was reported that required dose could be delivered with homogeneous dose distribution to the target without field matching using electron and photon beam. Therapeutic beam of tomotherapy, however, has several different physical characteristic and irradiation of helical beam is involved in the mechanically dynamic factors. Thus verification of skin dose is requisite using independent tools with additional verification method. Modified phantom for dose measurement was developed and skin dose verification was performed using inserted thermoluminescent dosimeters (TLDs) and GafChromic EBT films. As the homogeneous dose was delivered to the region including surface and 6 mm depth, measured dose using films showed about average 2% lower dose than calculated one in treatment planning system. Region indicating about 14% higher and lower absorbed dose was verified on measured dose distribution. Uniformity of dose distribution on films decreased as compared with that of calculated results. Dose variation affected by inhomogeneous material, Teflon, little showed. In regard to the measured dose and its distribution in tomotherapy, verification of skin dose through measurement is required before the radiation treatment for the target located at the curved surface or superficial depth.

  • PDF

A Study on Strategy for developing LBS Entertainment content based on local tourist information (지역 관광 정보를 활용한 LBS 엔터테인먼트 컨텐츠 개발 방안에 관한 연구)

  • Kim, Hyun-Jeong
    • Archives of design research
    • /
    • v.20 no.3 s.71
    • /
    • pp.151-162
    • /
    • 2007
  • How can new media devices and networks provide an effective response to the world's growing sector of cultural and historically-minded travelers? This study emerged from the question of how mobile handsets can change the nature of cultural and historical tourism in ubiquitous city environments. As wireless network and mobile IT have rapidly developed, it becomes possible to deliver cultural and historical information on the site through mobile handset as a tour guidance system. The paper describes the development of a new type of mobile tourism platform for site-specific cultural and historical information. The central objective of the project was to organize this cultural and historical walking tour around the mobile handset and its unique advantages (i.e. portability, multi-media capacity, access to wireless internet, and location-awareness potential) and then integrate the tour with a historical story and role-playing game that would deepen the mobile user's interest in the sites being visited, and enhance his or her overall experience of the area. The project was based on twelve locations that were culturally and historically significant to Korean War era in Busan. After the mobile tour game prototype was developed for this route, it was evaluated at the 10th PIFF (Pusan International Film Festival). After use test, some new strategies for developing mobile "edutainment content" to deliver cultural historical contents of the location were discussed. Combining 'edutainment' with a cultural and historical mobile walking tour brings a new dimension to existing approaches of the tourism and mobile content industry.

  • PDF

Effects of Light Intensity, Light Quality and Photoperiod for Growth of Perilla in a Closed-type Plant Factory System (완전제어형 식물공장에서 광량과 광질, 광주기가 들깨의 생장에 미치는 영향)

  • Sul, Seonggwan;Baek, Youngtaek;Cho, Young-Yeol
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.180-187
    • /
    • 2022
  • In order to select suitable light in a plant factory, electric energy use efficiency and light use efficiency should be considered simultaneously to consider operating costs as well as quantitative and functional aspects. The growth characteristics, electric energy use efficiency, light use efficiency by light intensity, LED ratio, and photoperiod conditions were compared together. Light intensity is 60, 130, 230, and 320 µmol·m-2·s-1 treatments, and light quality is the mixing ratio of red light and blue light 8:2, 6:4, 4:6, and 2:8 treatments. Photoperiod is 9, 12, 15, and 18 hours treatments based on the daytime. In the light intensity experiment, the growth rate increased as the light intensity increased, but there was no significant difference in the light use efficiency. When comparing the leaf fresh weight per power consumption, only the 320 µmol·m-2·s-1 treatment group showed significantly low efficiency, and there was no significant difference in the other treatments, so 230 µmol·m-2·s-1, which produced the most, was the most efficient. In the light quality experiment, the ratio of red light and blue light was measured to be high at the same time as the growth rate and light use efficiency in RB 8:2, and there was no significant difference in color difference and flavonoids content, so a Red:Blue ratio of 8:2 was the most suitable condition. In the photoperiod experiment, the longer the photoperiod, the higher the growth rate. However, there was no significant difference in the growth rate over 12 hours of daytime, so 12 hours considering the light consumption efficiency was a suitable condition. Based on the above results, LED light environmental conditions for perilla growth in plant factories were light intensity, light quality, and day length of 230 µmol·m-2·s-1 or more, 8:2, and 12 hours or more, respectively.

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

Clustering Method based on Genre Interest for Cold-Start Problem in Movie Recommendation (영화 추천 시스템의 초기 사용자 문제를 위한 장르 선호 기반의 클러스터링 기법)

  • You, Tithrottanak;Rosli, Ahmad Nurzid;Ha, Inay;Jo, Geun-Sik
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.1
    • /
    • pp.57-77
    • /
    • 2013
  • Social media has become one of the most popular media in web and mobile application. In 2011, social networks and blogs are still the top destination of online users, according to a study from Nielsen Company. In their studies, nearly 4 in 5active users visit social network and blog. Social Networks and Blogs sites rule Americans' Internet time, accounting to 23 percent of time spent online. Facebook is the main social network that the U.S internet users spend time more than the other social network services such as Yahoo, Google, AOL Media Network, Twitter, Linked In and so on. In recent trend, most of the companies promote their products in the Facebook by creating the "Facebook Page" that refers to specific product. The "Like" option allows user to subscribed and received updates their interested on from the page. The film makers which produce a lot of films around the world also take part to market and promote their films by exploiting the advantages of using the "Facebook Page". In addition, a great number of streaming service providers allows users to subscribe their service to watch and enjoy movies and TV program. They can instantly watch movies and TV program over the internet to PCs, Macs and TVs. Netflix alone as the world's leading subscription service have more than 30 million streaming members in the United States, Latin America, the United Kingdom and the Nordics. As the matter of facts, a million of movies and TV program with different of genres are offered to the subscriber. In contrast, users need spend a lot time to find the right movies which are related to their interest genre. Recent years there are many researchers who have been propose a method to improve prediction the rating or preference that would give the most related items such as books, music or movies to the garget user or the group of users that have the same interest in the particular items. One of the most popular methods to build recommendation system is traditional Collaborative Filtering (CF). The method compute the similarity of the target user and other users, which then are cluster in the same interest on items according which items that users have been rated. The method then predicts other items from the same group of users to recommend to a group of users. Moreover, There are many items that need to study for suggesting to users such as books, music, movies, news, videos and so on. However, in this paper we only focus on movie as item to recommend to users. In addition, there are many challenges for CF task. Firstly, the "sparsity problem"; it occurs when user information preference is not enough. The recommendation accuracies result is lower compared to the neighbor who composed with a large amount of ratings. The second problem is "cold-start problem"; it occurs whenever new users or items are added into the system, which each has norating or a few rating. For instance, no personalized predictions can be made for a new user without any ratings on the record. In this research we propose a clustering method according to the users' genre interest extracted from social network service (SNS) and user's movies rating information system to solve the "cold-start problem." Our proposed method will clusters the target user together with the other users by combining the user genre interest and the rating information. It is important to realize a huge amount of interesting and useful user's information from Facebook Graph, we can extract information from the "Facebook Page" which "Like" by them. Moreover, we use the Internet Movie Database(IMDb) as the main dataset. The IMDbis online databases that consist of a large amount of information related to movies, TV programs and including actors. This dataset not only used to provide movie information in our Movie Rating Systems, but also as resources to provide movie genre information which extracted from the "Facebook Page". Formerly, the user must login with their Facebook account to login to the Movie Rating System, at the same time our system will collect the genre interest from the "Facebook Page". We conduct many experiments with other methods to see how our method performs and we also compare to the other methods. First, we compared our proposed method in the case of the normal recommendation to see how our system improves the recommendation result. Then we experiment method in case of cold-start problem. Our experiment show that our method is outperform than the other methods. In these two cases of our experimentation, we see that our proposed method produces better result in case both cases.

Comparison of CT based-CTV plan and CT based-ICRU38 plan in Brachytherapy Planning of Uterine Cervix Cancer (자궁경부암 강내조사 시 CT를 이용한 CTV에 근거한 치료계획과 ICRU 38에 근거한 치료계획의 비교)

  • Cho, Jung-Ken;Han, Tae-Jong
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • Purpose : In spite of recent remarkable improvement of diagnostic imaging modalities such as CT, MRI, and PET and radiation therapy planing systems, ICR plan of uterine cervix cancer, based on recommendation of ICRU38(2D film-based) such as Point A, is still used widely. A 3-dimensional ICR plan based on CT image provides dose-volume histogram(DVH) information of the tumor and normal tissue. In this study, we compared tumor-dose, rectal-dose and bladder-dose through an analysis of DVH between CTV plan and ICRU38 plan based on CT image. Method and Material : We analyzed 11 patients with a cervix cancer who received the ICR of Ir-192 HDR. After 40Gy of external beam radiation therapy, ICR plan was established using PLATO(Nucletron) v.14.2 planing system. CT scan was done to all the patients using CT-simulator(Ultra Z, Philips). We contoured CTV, rectum and bladder on the CT image and established CTV plan which delivers the 100% dose to CTV and ICRU plan which delivers the 100% dose to the point A. Result : The volume$(average{\pm}SD)$ of CTV, rectum and bladder in all of 11 patients is $21.8{\pm}6.6cm^3,\;60.9{\pm}25.0cm^3,\;111.6{\pm}40.1cm^3$ respectively. The volume covered by 100% isodose curve is $126.7{\pm}18.9cm^3$ in ICRU plan and $98.2{\pm}74.5cm^3$ in CTV plan(p=0.0001), respectively. In (On) ICRU planning, $22.0cm^3$ of CTV volume was not covered by 100% isodose curve in one patient whose residual tumor size is greater than 4cm, while more than 100% dose was irradiated unnecessarily to the normal organ of $62.2{\pm}4.8cm^3$ other than the tumor in the remaining 10 patients with a residual tumor less than 4cm in size. Bladder dose recommended by ICRU 38 was $90.1{\pm}21.3%$ and $68.7{\pm}26.6%$ in ICRU plan and in CTV plan respectively(p=0.001) while rectal dose recommended by ICRU 38 was $86.4{\pm}18.3%$ and $76.9{\pm}15.6%$ in ICRU plan and in CTV plan, respectively(p=0.08). Bladder and rectum maximum dose was $137.2{\pm}50.1%,\;101.1{\pm}41.8%$ in ICRU plan and $107.6{\pm}47.9%,\;86.9{\pm}30.8%$ in CTV plan, respectively. Therefore, the radiation dose to normal organ was lower in CTV plan than in ICRU plan. But the normal tissue dose was remarkably higher than a recommended dose in CTV plan in one patient whose residual tumor size was greater than 4cm. The volume of rectum receiving more than 80% isodose (V80rec) was $1.8{\pm}2.4cm^3$ in ICRU plan and $0.7{\pm}1.0cm^3$ in CTV plan(p=0.02). The volume of bladder receiving more than 80% isodose(V80bla) was $12.2{\pm}8.9cm^3$ in ICRU plan and $3.5{\pm}4.1cm^3$ in CTV plan(p=0.005). According to these parameters, CTV plan could also save more normal tissue compared to ICRU38 plan. Conclusion : An unnecessary excessive radiation dose is irradiated to normal tissues within 100% isodose area in the traditional ICRU plan in case of a small size of cervix cancer, but if we use CTV plan based on CT image, the normal tissue dose could be reduced remarkably without a compromise of tumor dose. However, in a large tumor case, we need more research on an effective 3D-planing to reduce the normal tissue dose.

The Influence of Landscape Pavements on the WBGT of Outdoor Spaces without Ventilation or Shade at Summer Midday (조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 영향 - 통풍과 차광이 배제된 하절기 주간의 조건에서 -)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • The purpose of the study was to evaluate the influence of landscaping pavements on WBGT(Wet-Bulb Globe Temperature) of outdoor spaces that lack ventilation and shade at summer midday. The relative humidity(RH), dry-bulb temperature(DT) and globe temperature(GT) were recorded every minute from June to October 2009 at a height of 1.2m above ten experimental beds with different pavements, by a measuring system consisting of an electric humidity sensor(GHM-15), resistance temperature detector(RTD, Pt-100), standard black globe(${\phi} 150mm$) and data acquisition systems(National Instrument's Labview and Compact FieldPoint). Additionally, the surface dry-bulb temperatures also were recorded and compared. The area of each experimental bed was 1.5m(W)${\times}$2.0m(L) and ten different kinds of pavement were used including grass, grass+cubic stone, grass+porous brick, brick, stone panels, cubic stone, interlocking blocks, clay brick, naked soil, gravel and concrete. To prevent interference from ventilation, a 1.5m height cubic steel frame was established around each bed and each vertical side of the frame was covered with transparent polyethylene film. Based on the records of the hottest period from noon to 3 PM on 26 days with a peak dry-bulb temperature over $30^{\circ}C$ at natural condition, the wet-bulb temperature(WT) and WBGT were calculated and compared. The major findings were as follows: 1. The average surface DT was $40.1^{\circ}C$, which is $9^{\circ}C$ higher than that of the natural condition. The surface DT of the pavements with grass were higher than those of concrete and interlocking block. The peak DT of the surface almost every pavement rose to above $50^{\circ}C$ during the hottest time. 2. The averages of DT, WT and GT were $40.1^{\circ}C$, $27.5^{\circ}C$ and $49.1^{\circ}C$, and the peak values rose to $48.1^{\circ}C$, $45.8^{\circ}C$ and $59.5^{\circ}C$, respectively. In spite of slight differences that resulted according to pavements, no coherent differentiating factor could be found. 3. The average WBGT of grass was the highest at $34.3^{\circ}C$ while the others were similar in the range of around $33{\pm}1^{\circ}C$. Meanwhile, the peak WBGT was highest with stone panel at $47.9^{\circ}C$. Though there were some differences according to pavements, and while grass seemed to be worst in terms of WBGT, it seems difficult to say ablolutely that grass was the worst because the measurement was conducted without ventilation and shade during summer daytime hours only, which had temperatures that rose to a dangerous degree(above $45^{\circ}C$ WBGT), withering the grass during the hottest period. The average WBGT resulted also showed that the thermal environment of the pavement without ventilation and shade were at an intolerable level for humans regardless of the pavement type. In summary, the results of this study show that ventilation and shade are more important factor than pavement type in terms of outdoor thermal comfort in summer daylight hours.

Deconstructive reading of Makoto Shinkai's : Stories of things that cannot meet without their names (해체로 읽는 신카이 마코토의 <너의 이름은. 군(君)の명(名)は.> : 이름 없이는 서로 만날 수 없는 사물들에 대해)

  • Ahn, Yoon-kyung;Kim, Hyun-suk
    • Cartoon and Animation Studies
    • /
    • s.50
    • /
    • pp.75-99
    • /
    • 2018
  • Makoto Shinkai, an animated film maker in Japan, has been featured as a one-person production system and as a 'writer of light', but his 2016 release of "Your Name" was a departure from the elements that characterize his existing works. At the same time, by the combination of the traditional musubi(むすび) story, ending these, it was a big hit due to its rich narratives and attraction of open interpretation possibility. As it can be guessed from the title of this work, this work shows the encounter between the Japanese ancient language and the modern language in relation to the 'name', and presents the image that the role of the name(language) is repeatedly emphasized with various variations in events for the perfect 'encounter'. In this work, the interpretations of $Signifi\acute{e}$ for characters and objects are extended and reserved as a metaphorical role of the similarity, depending on the meaning of the subject which they touch. The relationship between words and objects analyzed through the structure of Signifiant and $Signifi\acute{e}$ is an epoch-making ideological discovery of modern times revealed through F. Saussure. Focusing on "the difference" between being this and that from the notion of Saussure, Derrida dismissed logocentrism, rationalism that fully obeyed the order of Logos. Likewise, dismissing the center, or dismissing the owner had emerged after the exclusive and closed principle of metaphysics in the west was dismissed. Derrida's definition of 'deconstruction' is a philosophical strategy that starts with the insight on the nature of language. 'Dissemination,' a metaphor that he used as a methodological concept to read texts acts as interpretation and practice (or play), but does not pursue an ultimate interpretation. His 'undecidability' does not start with infinity, but ends with infinity. The researcher testifies himself and identifies that we can't be an interpreter of the world because we, as a human are not the subject of language but a user. Derrida also interpreted the world of things composed of Signifiant and $Signifi\acute{e}$ as open texts. In this respect, this study aimed to read Makoto's works telling about the meeting of a thing and a thing with name as a guide, based on Derrida's frame of 'deconstruction' and 'dissemination.' This study intends to re-consider which relationship the Signifiant and $Signifi\acute{e}$ have with human beings who live in modern times, examine the relationship between words and objects presented in this work through Jacques Derrida's destruction and dissemination concepts, and recognize that we are merely a part of Signifiant and $Signifi\acute{e}$. Just as Taki and Mitsuha confirm the existence by asking each other, we are in the world of things, expecting musubi that a world of names calls me.

A Survey on Radiation Exposure of Patient in Mammography (유방 X선촬영 시 피폭선량에 대한 조사 연구)

  • Kim, Hyung-Chul;Cho, Pyung-Gon;Kim, Sung-Soo;Choi, Jong-Hak;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.55-60
    • /
    • 2004
  • The purpose of this study was to examine both patient exposure dose during mammography and the utility status of mammograpy equipments. The data of this study were collected through questionnaire survey for 278 medical facilities registered at Korean Hospital Association and finally 161 medical facilities's data were analyzed. According to data analysis, medical facilities of 14.9% used the average glandular dose of less than 0.5 mGy, $0.51{\sim}1.0\;mGy$ 8.6%, $1.01{\sim}1.5\;mGy$ 14.9%, $1.51{\sim}2.0\;mGy$ 11.1%, $2.01{\sim}2.5\;mGy$ 9.8%, $2.51{\sim}3.0\;mGy$ 33.3%, and 7.4% more than 3.01 mGy. It was found that medical facilities of 92.6% used less than 3 mGy, showing that this figure is similar to the limit value of 3 mGy recommended by Korea Food & Drug Administration(KFDA). Recently, international organizations such as ICRP associated with radiation protection suggests that less than 3 mGy of average mammary gland dose be used during mammography in case of using Mo target+Mo filter, film/screen system and craniocaudal projection with the breast pressed to 4.2 cm. The standard dose is being strictly observed and that of the limits is going down to 2 mGy or 1.5 mGy. The major results of this study indicate that interests and a counterplan to reduce patient dose during mammography should be considered. Based on this study, the authors of this study will continue to measure exposure dose to set a new standard for patient exposure dose during mammography.

  • PDF

Evaluation of Electron Boost Fields based on Surgical Clips and Operative Scars in Definitive Breast Irradiation (유방보존술 후 방사선치료에서 수술 흉터와 삽입된 클립을 이용한 전자설 추가 방사선 조사야 평가)

  • Lee, Re-Na;Chung, Eun-Ah;Lee, Ji-Hye;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.236-242
    • /
    • 2005
  • Purpose: To evaluate the role of surgical clips and scars in determining electron boost field for early stage breast cancer undergoing conserving surgery and postoperative radiotherapy and to provide an optimal method in drawing the boost field. Materials and Methods: Twenty patients who had $4{\sim}7$ surgical clips in the excision cavity were selected for this study. The depth informations were obtained to determine electron energy by measuring the distance from the skin to chest wall (SCD) and to the clip implanted in the most posterior area of tumor bed. Three different electron fields were outlined on a simulation film. The radiological tumor bed was determined by connecting all the clips implanted during surgery Clinical field (CF) was drawn by adding 3 cm margin around surgical scar. Surgical field (SF) was drawn by adding 2 cm margin around surgical clips and an Ideal field (IF) was outlined by adding 2 cm margin around both scar and clips. These fields were digitized into our planning system to measure the area of each separate field. The areas of the three different electron boost fields were compared. Finally, surgical clips were contoured on axial CT images and dose volume histogram was plotted to investigate 3-dimensional coverage of the clips. Results : The average depth difference between SCD and the maximal clip location was $0.7{\pm}0.55cm$. Greater difference of 5 mm or more was seen in 12 patients. The average shift between the borders of scar and clips were 1.7 1.2, 1.2, and 0.9 cm in superior, inferior, medial, and lateral directions, respectively. The area of the CF was larger than SF and IF in 6y20 patients. In 15/20 patients, the area difference between SF and if was less than 5%. One to three clips were seen outside the CF in 15/20 patients. In addition, dosimetrically inadequate coverage of clips (less than 80% of prescribed dose) were observed in 17/20 patients when CF was used as the boost field. Conclusion: The electron field determined from clinical scar underestimates the tumor bed in superior-inferior direction significantly and thereby underdosing the tissue at risk. The electron field obtained from surgical clips alone dose not cover the entire scar properly As a consequence, our technique, which combines the surgical clips and clinical scars in determining electron boost field, was proved to be effective in minimizing the geographical miss as well as normal tissue complications.