• 제목/요약/키워드: filling ratio

검색결과 531건 처리시간 0.035초

Incremental filling ratio of pipe pile groups in sandy soil

  • Fattah, Mohammed Y.;Salim, Nahla M.;Al-Gharrawi, Asaad M.B.
    • Geomechanics and Engineering
    • /
    • 제15권1호
    • /
    • pp.695-710
    • /
    • 2018
  • Formation of a soil plug in an open-ended pile is a very important factor in determining the pile behavior both during driving and during static loading. The degree of soil plugging can be represented by the incremental filling ratio (IFR) which is defined as the change in the plug length to the change of the pile embedment length. The experimental tests carried out in this research contain 138 tests that are divided as follows: 36 tests for single pile, 36 tests for pile group ($2{\times}1$), 36 tests for pile group ($2{\times}2$) and 30 pile group ($2{\times}3$). All tubular piles were tested using the poorly graded sand from the city of Karbala in Iraq. The sand was prepared at three different densities using a raining technique. Different parameters are considered such as method of installation, relative density, removal of soil plug with respect to length of plug and pile length to diameter ratio. The soil plug is removed using a new device which is manufactured to remove the soil column inside open pipe piles group installed using driving and pressing device. The principle of soil plug removal depends on suction of sand inside the pile. It was concluded that the incremental filling ratio (IFR) is changed with the changing of soil state and method of installation. For driven pipe pile group, the average IFR for piles in loose is 18% and 19.5% for L/D=12 and 15, respectively, while the average of IFR for driven piles in dense sand is 30% and 20% for L/D=12 and L/D=15 respectively. For pressed method of pile installation, the average IFR for group is zero for loose and medium sand and about 5% for dense sand. The group capacity increases with the increase of IFR. For driven pile with length of 450 mm, the average IFR % is about 30.3% in dense sand, 14% in medium and 18.3% for loose sand while when the length of pile is 300 mm, the percentage equals to 20%, 17% and 19.5%, respectively.

광해로 인한 지반침하의 효율적인 보강방안에 관한 수치해석 (Numerical Analysis on Effective Countermeasure for Ground Subsidence due to Mining Hazard)

  • 홍원표;이재호;허세영
    • 한국지반신소재학회논문집
    • /
    • 제6권4호
    • /
    • pp.7-13
    • /
    • 2007
  • 폐탄광 지역에 도로, 철도 등의 시설물이 건설되는 경우, 침하를 억지하기 위한 지반보강이 필요하다. 본 연구에서는 다양한 보강공법을 적용한 경우에 대한 수치해석을 실시하여 적용공법별 지반보강효과를 평가하였다. 해석결과 채굴적 상부지반만을 보강하는 경우에는 보강효과가 작았으며, 채굴적을 충전하는 공법이 지반침하를 억지하는 효과가 가장 큰 것으로 나타났다. 또한, 채굴적을 충전하여 지반을 보강하는 경우, 지반침하는 채굴적의 충전율에 따라 쌍곡선형태로 감소하는 것으로 나타났으며, 채굴적 충전율과 침하저감율 사이의 상관관계를 제시하였다.

  • PDF

투수성 콘크리트의 강도개선에 관한 연구 (A Study on the Improvements of Strengths of Water-Permeable Concrete)

  • 은재기;이철웅;김완기;조영국;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.307-312
    • /
    • 1999
  • The purpose of this study is to ascertain the strength properties of water-permeable concrete with redispersible polymer powder, silica fume and polypropylene fibers. The water-permeable concrete using rediapersibel polymer powder with a water-cement ratio of 25%, polymer-cement ratios of 0 to 10%, silica fume contents of 0 to 10% and fiber contents of 0 to 1.5% are prepared, and tested for flexural strength, compressive strength and water permeability. From the test results, improvements in the strength properties of the water-permeable concrete due to the addition of the redispersible polymer powder, silica fume and fibers are discussed. It is concluded from the test results that the superior flexural and compressive strengths of water-permeable concretes are obtained at a propylene fiber content of 1.0% with a void filling ratio of 50%. And, the water-permeable concrete having a flexural strength of 15.6~28.4kgf/$\textrm{cm}^2$, a compressive strength of 63.5~120.6kgf/$\textrm{cm}^2$, and a coefficient of permeability of 1.14~1.70cm/s at a void filling ratio of 30% can be prepared. Also water-permeable concrete having a flexural strength of 35.6~57.9kgf/$\textrm{cm}^2$, a compressive strength of 164.0~290.0kgf/$\textrm{cm}^2$, and a coefficient of permeability of 0.19~1.04cm/s at a void filling ratio of 50% can be prepared in the consideration of the mix proprotioning factors.

  • PDF

Analysis of Cell Performance with Varied Electrolyte Species and Amounts in a Molten Carbonate Fuel Cell

  • Lee, Ki-Jeong;Kim, Yu-Jeong;Koomson, Samuel;Lee, Choong-Gon
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권2호
    • /
    • pp.141-148
    • /
    • 2018
  • This study evaluated the performance characteristics of varied electrolyte species and amounts in a molten carbonate fuel cell (MCFC). Coin-type MCFCs were used at the condition of $650^{\circ}C$ and 1 atm. In order to measure the effects of varied electrolyte species and amounts, electrolytes of $(Li+K)_2CO_3$ and $(Li+Na)_2CO_3$ were selected and the amounts of 1.5 g, 2.0 g, 3.0 g, and 4.0 g were used. Insignificant performance differences were observed in the cell using different electrolytes, but the cell performance was sensitive to the amount of the electrolyte used. The pore-filling ratio (PFR), a ratio of pore filling in the components by the liquid carbonate electrolytes, was used to determine the optimum performance range. Consequently, 77% PFR demonstrated the optimum performance for both electrolytes. Thus, the MCFC had a permissible but narrow optimum performance range. The remaining amounts of electrolyte in the cells were determined using the weight reduction ratio (WRR) method after several hours of cell operation. The WRR used the relationship between the initial loaded amount of electrolyte and weight reduction of components in 10 wt% acetic acid. The relationships were linear and identical between the two electrolyte species.

박판 사출 성형에서 게이트 폭에 따른 충전 불균형에 대한 연구 (A Study on the Filling Pattern Imbalance by Width of Gate in the Thin Plate Injection Molding)

  • 정태성;장진혁;김종선
    • Design & Manufacturing
    • /
    • 제11권1호
    • /
    • pp.14-18
    • /
    • 2017
  • Recently, the injection-molded products are lighter, and thinner than ever. In this work, Injection molding simulation was conducted to analysis the filling pattern imbalance in high speed injection molding process for thin-wall injection component, 8 inches LGP. Numerical analysis shows that shear heated polymer near the side wall causes filling imbalance between center and side of cavity. Short shot experiments were conducted and compared with simulation results. Filling imbalance ratio showed a tendency to increase for wider fan gate.

고체 알칼리 연료전지용 음이온 교환 세공충진막의 제조 및 특성 (Preparation of pore-filling membranes for polymer electrolyte fuel cells and their cell performances)

  • 최영우;박구곤;임성대;이미순;양태현;김창수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.150-153
    • /
    • 2009
  • Anion exchange polymer electrolyte pore-filling membranes consisting of the whole hydrocarbon materials were prepared by photo polymerization with various quaternary ammonium cationic monomers and characterized on the properties for applying to solid alkali fuel cell (SAFC). Hydrocarbon porous substrates such as polyethylene were used for the preparation of the pore-filling membranes. The hydroxyl ion conductivity of the polymer electrolyte membranes prepared in this research was dependent on the composition ratio of an electrolyte monomer and crosslinking agents used for polymerization. Furthermore, these pore-filling membranes have commonly excellent properties such as smaller dimensional affects when swollen in solvents, higher mechanical strength, lower fuel crossover through the membranes, and easier preparation process than those of traditional cast membranes.

  • PDF

Mg합금의 반용융가압주조시 주조조건에 의한 금형충전성 및 유동성 변화 (A Study on Mold Filling and Fluidity of Mg Alloy in Thixocasting)

  • 정운재;김기태;홍준표
    • 한국주조공학회지
    • /
    • 제15권2호
    • /
    • pp.184-193
    • /
    • 1995
  • Effects of process parameters during thixocasting, such as solid volume fraction, mold temperature and extrusion ratio, on the mold filling behaviour and fluidity of Mg alloy(AZ91D) have been investigated. The semi-solid ingot held for 60 minutes at the semi-solid temperature range did not contain the equilibrium volume fraction of solid as expected from the phase diagram. Therefore, in order to obtain the desired solid fractions, and to suppress the exaggerated grain growth during heating, it was required to heat the ingot rapidly up to the temperature $10^{\circ}C$ higher than the semi-solid temperature suggested from the phase diagram for a specific volume fraction of solid. The experimental results show that mold filling behaviour and fluidity can be improved with the use of the higher mold temperature and the lower volume fraction of solid, but remain nearly unaffected by the change of extrusion ratio.

  • PDF

고세장비 미세형상 사출성형시 금형온도의 영향 고찰 (Effect of Mold Temperature on Injection Molding of Micro-Features with High Aspect Ratio)

  • 박정민;도범석;엄혜주;박근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1124-1128
    • /
    • 2008
  • Thin-wall injection molding is associated with many advantages, including increased portability, the conserving of materials, and the reduction of the molding cycle times. In the application of the thin-wall molding, a considerable reduction of the effective flow thickness results in filling difficulty. High-frequency induction is an efficient way to overcome this filling difficulty by means of heating the mold surface by electromagnetic induction. The present study applies the induction heating to the injection molding of thinwalled micro structures with high aspect ratio. The feasibility of the proposed heating method is investigated through a numerical analysis. The estimated filling characteristics of the micro-features are investigated with variations of mold temperature and part thickness, of which results are also compared with experimental measurements.

  • PDF