• 제목/요약/키워드: fill power

Search Result 254, Processing Time 0.038 seconds

Transient Thermal Behaviors of Melt Processed Superconductors with Artificial Holes During the Cooling in Liquid Nitrogen (액체질소 냉각 시 임의의 홀을 가진 초전도체의 열응력 해석)

  • Jang, G.E.;Lee, H.J.;Kim, C.J.;Han, Y.H.;Sung, T.H.
    • Progress in Superconductivity
    • /
    • v.11 no.1
    • /
    • pp.52-56
    • /
    • 2009
  • Temperature distributions and thermal stresses were calculated and analyzed to investigate the effect of the artificial holes to the transient behaviors of the superconductors which was cooled in liquid nitrogen. Three dimensional finite element method was used to calculated the transient temperature and thermal stresses in the superconductors. The cooling speed of the superconductors with holes is faster than those without holes. Because the thermal stresses calculated in the superconductors can be relaxed by the distributed holes, the volume of the peak tensile stress decreases during the cooling in liquid nitrogen. If optimal metal, which can maintain the relaxation of thermal stresses, is used to fill and reinforce the artificial holes, the probability of failure of the superconductors may be decreased by the decrease of volume of peak tensile stress.

  • PDF

A Study on the Performance Improvement for Flexible PCDTBT : PC71BM Organic Thin Film Solar Cell by Ozone Surface Treatment of ITO Electrode (ITO 전극의 오존 표면처리에 의한 플렉시블 PCDTBT : PC71BM 유기박막 태양전지의 성능 개선에 관한 연구)

  • No, Im-Jun;Lim, Young-Taek;Shin, Paik-Kyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.11
    • /
    • pp.104-108
    • /
    • 2012
  • Flexible organic thin film solar cell device with Bulk Hetero-Junction (BHJ) structure was fabricated with blended conjugated polymer of PCDTBT : $PC_{71}BM$ as active layer. Surface of ITO anode for the organic solar cell device was treated with ozone. The organic solar cell device with bare ITO showed short circuit current density ($J_{sc}$) of $8.2mA/cm^2$, open-circuit voltage ($V_{oc}$) of 0.73V, fill factor (FF) of 0.36, and power conversion efficiency (PCE) of 2.16%, respectively. The organic solar cell device with ozone treated ITO anode revealed distinctively improved performance parameters:$J_{sc}$ of $9.8mA/cm^2$, $V_{oc}$ of 0.82V, FF of 0.43, PCE(${\eta}$) of 3.42%.

A Study on Heat Transfer Performance with the Changes of Working Fluid Filling Ratio for Thermosyphon with Internal Groove (내부 그루브를 가진 열사이폰의 작동유체 봉입량 변화에 따른 열전달 성능에 관한 연구)

  • Ye, S.S.;Han, K.I.
    • Journal of Power System Engineering
    • /
    • v.4 no.3
    • /
    • pp.19-24
    • /
    • 2000
  • This study concerns the performance of the heat transfer of the thermosyphon having 80 internal groove in which boiling and condensation occur. Distilled water has been used as a working fluid. The liquid filling as the ratio of working fluid volume to total volume of thermosyphon has been used as the experimental parameters. The heat flux and heat transfer coefficient at the condenser are estimated from the experimental results. The experimental results have been assessed and compared with the existing theories. As a result of the experimental investigation, the maximum heat flow rate in the thermosyphon is proved to be dependent upon the liquid fill quantity. relatively high rates of heat transfer have been achieved operating in the thermosyphon with the internal groove. Also, a thermosyphon with the internal groove can be used to achieve some inexpensive and compact heat exchangers in low temperature. In addition, overall heat transfer coefficients and the characteristics as an operating temperature are obtained for the practical applications.

  • PDF

Performance of Crystalline Si Solar Cells with Temperature Controlled by a Thermoelectric Module (열전소자 온도조절법을 이용한 결정형 실리콘 태양전지의 성능 측정)

  • Heo, Kimoo;Lee, Daeho;Lee, Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.375-379
    • /
    • 2015
  • A proper estimate of solar cell efficiency is of great importance for the feasibility analysis of solar cell power plant development. Since solar cell efficiency depends on temperature, several methods have been introduced to measure it by operating temperature modulation. However, the methods either rely on the external environment or need expensive equipment. In this paper, a thermoelectric module was used to control the operating temperature of crystalline silicon solar cells effectively and precisely over a wide range. The output characteristics of crystalline silicon solar cells in response to operating temperatures from $-5^{\circ}C$ to $100^{\circ}C$ were investigated experimentally. Their efficiencies decreased as the temperature rose, since the decrease in the open circuit voltage and fill factor exceeded the increase in the short circuit current. The maximum power temperature coefficient of the single crystalline solar cell was more sensitive to temperature change than that of the polycrystalline solar cell.

Electrical and optical characterizations of OSCs based on polymer/fullerene BHJ structures with LiF inter-layer (Polymer/fullerene/LiF inter-layer BHJ 유기태양전지의 광학 및 전기적 특성에 대한 연구)

  • Song, Yoon-Seog;Kim, Seung-Ju;Ryu, S.O.
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.1
    • /
    • pp.27-32
    • /
    • 2011
  • In this study, we have investigated the power conversion efficiency of organic solar cells utilizing conjugated polymer/fullerene bulk-hetero junction(BHJ) device structures. We have fabricated poly(3-hexylthiophene)(P3HT), poly[2methoxy-5-(3',7'-dimethyloctyl-oxy)-1-4-phenylenevinylene] as an electron donor, [6,6]-phenyl $C_{61}$ butyric acid methylester(PCBM-$C_{61}$)as an electron acceptor, and poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate)(PEDOT:PSS) used as a hole injection layer(HIL), after fabricated active layer, between active layer and metal cathode(Al) deposited LiF interlayer(5 nm). The properties of fabricated organic solar cell(OSC) devices have been analyzed as a function of different thickness. The electrical characteristics of the fabricated devices were investigated by means J-V, fill factor(FF) and power conversion efficiency(PCE). We observed the highest PCEs of 0.628%(MDMO-PPV:PCBM-$C_{61}$) and 2.3%(P3HT:PCBM-$C_{61}$) with LiF inter-layer at the highest thick active layer, which is 1.3times better than the device without LiF inter-layer.

An Empirical Study of Competition in Mongolian Banking (몽골 은행산업에서의 시장경쟁에 대한 연구)

  • KIM, Donghun
    • International Area Studies Review
    • /
    • v.13 no.3
    • /
    • pp.3-27
    • /
    • 2009
  • This paper measures market power in the Mongolian banking sector using bank level panel data for commercial banks over the period of 1999 - 2006. In the literature, studies on banking competition have largely focused on the banking sectors of developed economies. However, banking competition in developing countries such as Mongolia has been largely neglected. This paper is an attempt to fill this gap. We find that both the monopoly hypothesis and the perfect competition hypothesis are rejected and that the Mongolian banking sector is instead characterized by monopolistic competition. We thus find that the Mongolian banking sector is more competitive than market concentration measures may suggest. We infer that the entries of new banks have strengthened market competitiveness.

A Study on Heat Transfer Coefficient of a Perfluorocarbon Heat Pipe (Perfluorocarbon 히트파이프의 열전달 계수에 관한 연구)

  • 강환국;김철주;김재진
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.194-201
    • /
    • 1998
  • In electric commuter trains using AC motors, lots of GTO thyristors and diodes are needed for power controls. These semiconductors generate heat about 1~2 kW, and for cooling which perfluorocarbon(PFC) heat pipes have been in use for the last two decades. The present study was investigated on the effects of such important design parameters as structure of internal surface (grooved or smooth), fill charge ratio, and inclinating angle from a vertical on heat transfer coefficients at both evaporators and condensers. To obtain experimental data, several heat pipes of the same geometry of 520 mm long and diameter of 15.88 mm but different in fill charge ratio and internal surface structure were designed and fabricated. For prediction of the heat transfer coefficients, related expressions were examined and the results of calculations were compared with experimental data. Performance tests were conducted while heat pipes operated at mode of thermosyphons. High enhancements of heat transfer coefficient were obtained internal grooves. In these cases, the evaporating heat transfer coefficients distributed in the range of 2~5.5 kW/$m^2$K, with an increase of heat flux from 15~45 kW/$m^2$. These experimental data were in good agreement with Rohsenow's expression based on nucleate boiling when correction factor $C_R$=1.3 was encountered. In addition, the condensation heat transfer coefficients were distributed from 1.5 to 3.5 kW/$m^2$K, and the data were in good agreements with Nusselt's correlation, based on filmwise condensation on vertical plate, when choosing a correction factor $C_N=4$. A fill charge ratio of 40~100% were recommended, and the in clination angle effects were negligible when the angle was higher then 30$^{\circ}$.

  • PDF

The Theory of Smoke Movement by a Fire in an Enclosure (밀폐공간에서의 화재에 의한 연기의 유동 이론)

  • 노재성;유홍선
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.5-9
    • /
    • 1996
  • In foreign country such as U.S.A and Japan, considerable research has been done regarding the spread of smoke in room of fire involvement by using computer. But, in our country it has not been. So, this paper presents a detailed qualitative description of phenomena which occures during typical fire scenarios through numerical analysis. This research, in the view of field model, is focused on finding out the smoke movement and temperature distribution. And it is planned to analyze governing equation including smoke diffusion equation by numerical analysis with finite volume method and non-staggered grid system. The SIMPLE method for pressure-velocity couple and power-law scheme for convection terms are used. It shows that a plume is formed, hot plume is formed, hot plume gases impinge on the ceiling and they spread across it. then, it eventually reaches the bounding walls of the enclosure. It takes 60s for smoke to fill the enclosure.

  • PDF

Thin Film Morphology Control of P3HT:PCBM Organic Solar Cells Using Electrospray Deposition Process

  • Hwang, Won-Tae;Choe, Su-Jeong;Chae, Hui-Yeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.432-433
    • /
    • 2012
  • Polymer solar cells are fabricated using electrospray (e-spray) deposition process. It shows comparable performance with reference devices, and has different characteristics according to the thickness of the active layer: In the case of the devices with higher fill factor, it shows relatively lower current density, and vice versa. These films are characterized by atomic force microscopy measurement. The results indicate that the comparable power conversion efficiency made by e-spray results from the 'solvent annealing effect' by process conditions and the different thin film property is caused by the degree of self-organization of the polymer.

  • PDF

Large tests of independence in incomplete two-way contingency tables using fractional imputation

  • Kang, Shin-Soo;Larsen, Michael D.
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.4
    • /
    • pp.971-984
    • /
    • 2015
  • Imputation procedures fill-in missing values, thereby enabling complete data analyses. Fully efficient fractional imputation (FEFI) and multiple imputation (MI) create multiple versions of the missing observations, thereby reflecting uncertainty about their true values. Methods have been described for hypothesis testing with multiple imputation. Fractional imputation assigns weights to the observed data to compensate for missing values. The focus of this article is the development of tests of independence using FEFI for partially classified two-way contingency tables. Wald and deviance tests of independence under FEFI are proposed. Simulations are used to compare type I error rates and Power. The partially observed marginal information is useful for estimating the joint distribution of cell probabilities, but it is not useful for testing association. FEFI compares favorably to other methods in simulations.