• 제목/요약/키워드: field load

검색결과 2,545건 처리시간 0.071초

RC 슬래브 교량의 현장재하시험을 통한 안전성 평가 (Safety Evaluation through Field Load Test of RC Slab Bridge)

  • 조한민
    • 도시과학
    • /
    • 제11권1호
    • /
    • pp.9-13
    • /
    • 2022
  • Currently, RC slab bridges in use in Korea account for most of the total bridges, and bridges with a service life of 20 years or more account for about 75%. However, most of these RC slab bridges have a span of less than 20m and are not included in the first and second types of facilities, so maintenance is very neglected. Therefore, in this study, field load test is performed on an aged RC slab bridge, and the performance evaluation is performed based on the structural response results (deflection, impact coefficient, natural frequency, etc.) of the bridge obtained through field load test. In addition, the performance evaluation results obtained through the load test are intended to be used as basic data for the damage evaluation process of the bridge currently under development.

습답 로터리 작업에 대한 농용 트랙터의 변속기 부하 가혹도에 관한 연구 (Severeness of Transmission Loads of Agricultural Tractor for Rotary Operations in Poorly Drained Paddy Field)

  • 한경훈;김경욱;오영근
    • Journal of Biosystems Engineering
    • /
    • 제24권4호
    • /
    • pp.293-300
    • /
    • 1999
  • The objectives of this study were to analyze the load acting on the transmission when tractor performed rotary operations in the poorly drained paddy fields and to compare its severeness with those obtained under different operational conditions. The loads were measured at the input shaft of the transmission and the load spectrum was constructed using the rain-flow cycle counting method. The severeness of the loads was represented by the partial damage sum which was determined by suing the modified Miner's rule. In the field with a shallow hardpan PTO speed affected severeness of the rotary operations greater than the forward speed did. In the field with deep hardpan, on the other hand, the effect of the forward speed was greater. the severeness in the well drained fields did not differ significantly from that in the field with a shallow hardpan. The severest load was recorded in the field with a deep hardpan.

  • PDF

Bridge load testing and rating: a case study through wireless sensing technology

  • Shoukry, Samir N.;Luo, Yan;Riad, Mourad Y.;William, Gergis W.
    • Smart Structures and Systems
    • /
    • 제12권6호
    • /
    • pp.661-678
    • /
    • 2013
  • In this paper, a wireless sensing system for structural field evaluation and rating of bridges is presented. The system uses a wireless platform integrated with traditional analogue sensors including strain gages and accelerometers along with the operating software. A wireless vehicle position indicator is developed using a tri-axial accelerometer node that is mounted on the test vehicle, and was used for identifying the moving truck position during load testing. The developed software is capable of calculating the theoretical bridge rating factors based on AASHTO Load and Resistance Factor Rating specifications, and automatically produces the field adjustment factor through load testing data. The sensing system along with its application in bridge deck rating was successfully demonstrated on the Evansville Bridge in West Virginia. A finite element model was conducted for the test bridge, and was used to calculate the load distribution factors of the bridge deck after verifying its results using field data. A confirmation field test was conducted on the same bridge and its results varied by only 3% from the first test. The proposed wireless sensing system proved to be a reliable tool that overcomes multiple drawbacks of conventional wired sensing platforms designed for structural load evaluation of bridges.

Pre-processing of load data of agricultural tractors during major field operations

  • Ryu, Myong-Jin;Kabir, Md. Shaha Nur;Choo, Youn-Kug;Chung, Sun-Ok;Kim, Yong-Joo;Ha, Jong-Kyou;Lee, Kyeong-Hwan
    • 농업과학연구
    • /
    • 제42권1호
    • /
    • pp.53-61
    • /
    • 2015
  • Development of highly efficient and energy-saving tractors has been one of the issues in agricultural machinery. For design of such tractors, measurement and analysis of load on major power transmission parts of the tractors are the most important pre-requisite tasks. Objective of this study was to perform pre-processing procedures before effective analysis of load data of agricultural tractors (30, 75, and 82 kW) during major field operations such as plow tillage, rotary tillage, baling, bale wrapping, and to select the suitable pre-processing method for the analysis. A load measurement systems, equipped in the tractors, were consisted of strain-gauge, encoder, hydraulic pressure, and radar speed sensors to measure torque and rotational speed levels of transmission input shaft, PTO shaft, and driving axle shafts, pressure of the hydraulic inlet line, and travel speed, respectively. The entire sensor data were collected at a 200-Hz rate. Plow tillage, rotary tillage, baling, wrapping, and loader operations were selected as major field operations of agricultural tractors. Same or different farm works and driving levels were set differently for each of the load measuring experiment. Before load data analysis, pre-processing procedures such as outlier removal, low-pass filtering, and data division were performed. Data beyond the scope of the measuring range of the sensors and the operating range of the power transmission parts were removed. Considering engine and PTO rotational speeds, frequency components greater than 90, 60, and 60 Hz cut off frequencies were low-pass filtered for plow tillage, rotary tillage, and baler operations, respectively. Measured load data were divided into five parts: driving, working, implement up, implement down, and turning. Results of the study would provide useful information for load characteristics of tractors on major field operations.

Numerical investigation of glass windows under near-field blast

  • Chiara Bedon;Damijan Markovic;Vasilis Karlos;Martin Larcher
    • Coupled systems mechanics
    • /
    • 제12권2호
    • /
    • pp.167-181
    • /
    • 2023
  • The determination of the blast protection level and the corresponding minimum load-bearing capacity for a laminated glass (LG) window is of crucial importance for safety and security design purposes. In this paper, the focus is given to the window response under near-field blast loading, i.e., where relatively small explosives would be activated close to the target, representative of attack scenarios using small commercial drones. In general, the assessment of the load-bearing capacity of a window is based on complex and expensive experiments, which can be conducted for a small number of configurations. On the other hand, nowadays, validated numerical simulations tools based on the Finite Element Method (FEM) are available to partially substitute the physical tests for the assessment of the performance of various LG systems, especially for the far-field blast loading. However, very little literature is available on the LG window performance under near-field blast loads, which differs from far-field situations in two points: i) the duration of the load is very short, since the blast wavelength tends to increase with the distance and ii) the load distribution is not uniform over the window surface, as opposed to the almost plane wave configuration for far-field configurations. Therefore, the current study focuses on the performance assessment and structural behaviour of LG windows under near-field blasts. Typical behavioural trends are investigated, by taking into account possible relevant damage mechanisms in the LG window components, while size effects for target LG windows are also addressed under a multitude of blast loading configurations.

전기철도 일형식 부하 크기에 따른 전압강하 측정 및 분석 (Test and Analysis of Voltage Drop according to Load Capacity in Traction Power Supply System)

  • 김주락;장동욱;창상훈;이영흠
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.940-947
    • /
    • 2011
  • Load capacity varies according to a day of the week in traction power supply system, because time schedule in railway is changed as demand for passengers and freights. Therefore, Voltage drop also varies as load capacity. In Korea railway, Voltage collected from catenary in train is decreased, as load supplied traction power supply system is increased. Therefore, investigation about voltage drop should be performed, before development of countermeasure against voltage drop. The investigation can be performed by simulation or field test. Naturally, field test is more precise than simulation. In addition, field test should be carried out at peak load. This paper presents test and analysis about voltage drop in railway. The test is performed in both a day of the week and weekend. The analysis is figured out comparison load capacity between two days and voltage drop across terminal.

  • PDF

직통직권 발전기에 의한 직통분권 전동기의 특성해석 (Analysis of D-C Shunt Motor Characteristics, driving D-C Series Generator)

  • 이승원;한송엽
    • 전기의세계
    • /
    • 제16권1호
    • /
    • pp.7-13
    • /
    • 1967
  • There are many kinds of motors operating by rated voltage which is constant. In this paper, the characteristics of separately excited direct current motor is analyzed when its terminal voltage is varied as its load current. As for this source, direct current generator of a series field is used, and it is driven at constant speed by a primemover. The induced voltage of the generator is propotional to its load current but it saturates as its load current is large. The charateristics of motor is studied by analog computer because of the nonlinearity of generator. The results are as follows: (1) The load current and the rotor speed of motor increase as the load of motor increases. But the speed of rotor decreases for the influence of the saturation of the iron of generator field when its load current is large. (2) Decreasing the inertia of motor and increasing the inductance of the armature circuit improve the stability of motor and the region of stable state. (3) By changing the field current of the motor, the speed and the direction of rotor can be controlled in wide range.

  • PDF

프리플렉스 합성형교의 내하력 평가에 관한 연구 (A Study on the Load Carrying Capacity Assessment of the Preflex Beam Bridge)

  • 채원규
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1997년도 추계 학술논문발표회 논문집
    • /
    • pp.145-150
    • /
    • 1997
  • In this thesis, the field test by truck load and the structural analysis were performed on a preflex beam bridge to investigate the load carrying capacity. From the field test and the structural analysis results, K(corrective factor) and $P_n$(load carrying capacity) of the preflex beam bridges were studied, and these factors were applied to the load carrying capacity assessment of the preflex bridges.

  • PDF

연속 프리스트레스트 콘크리트 빔교의 내하력 평가 기법에 관한 연구 (A Study on the Load Carrying Capacity Assessment Method of the Prestressed Concrete Beam Bridges)

  • 채원규
    • 한국안전학회지
    • /
    • 제13권3호
    • /
    • pp.126-134
    • /
    • 1998
  • In this paper, the field test by truck load and the structural analysis were performed on a prestressed concrete beam bridge to investigate the load carrying capacity of the prestressed concrete beam bridges. From the results of the field test and the structural analysis, CAF (composite action factor), TIF(transformed impact factor), and $P_n$(load carrying capacity) of the prestressed concrete beam bridges were studied, and the load carrying capacity assessment of the prestressed concrete beam bridges were carried out using these factors.

  • PDF

액비 및 유기농법 적용에 따른 농경지에서의 오염부하 원단위 평가 (Assessing unit load in farmland by application of liquid manure and organic farming)

  • 소현철;장태일;홍승길
    • 농촌계획
    • /
    • 제23권4호
    • /
    • pp.39-48
    • /
    • 2017
  • National Institute of Environmental Research (NIER) has proposed new methodology for estimating unit load in order to overcome the limitations of past unit load based on short-term and local area based data. In the case of agricultural land, however, the results presented by NIER are still limited because of various agricultural activities and farmland characteristics. In this study, liquid manure treated paddy field and organic farming upland were selected for considering agricultural diversity. Four different methods for evaluating unit load were used for comparing previous research results. The results of different methods presented various trends compared with those of existing studies. Paddy field treated liquid manure was 1.3 times higher for T-N load and 3.1 times for T-P load than conventional paddy field. Conventional upland was 4.4 times higher for T-N load and 1.8 times higher for T-P load than organic farming upland. In the case of non-conventional farmland, this study showed different values with the unit loads presented by NIER. This implies that it is necessary to review and apply the unit loads considering various agricultural conditions when establishing environmental policy and rural planning.