• Title/Summary/Keyword: field instrument

Search Result 568, Processing Time 0.027 seconds

Development of a Test of Science Inquiry Skills Elementary School Students (국민학생(園民學生)의 과학(科學) 탐구능력(探究能力) 측정(測定)을 위한 평가도구(評價道具) 개발(開發))

  • Chung, Wan-Ho;Hur, Myung;Eun, Kyong-Yang
    • Journal of The Korean Association For Science Education
    • /
    • v.13 no.1
    • /
    • pp.80-91
    • /
    • 1993
  • The purpose of this study is to develop an reliable instrument for evaluating science inquiry skills through an R&D procedure. A total of ten seience inquiry skills were selected for the development of the instrument, ie, observation, classifying, recognizing problems, measuring, inferring, formulating hypothesis, controlling variables, experimenting, interpreting and drowing a conclusion. And three items were developed for each sceince inquiry skill, totaling up to thirty items. The content areas of developed items are divided into three categories, material and energy, life and environment, and the earth and the space. There are 10 items for each category. The content validity and the objectivity of developed items were checked, verified in the two field trials and revised according to the analysis of items by seven experienced specialists with the degree of doctors in science education and five teachers who were studying for their master's degree in science education. According to the results of the second field trial. the content validity of the instrument was 91.1%, reliablity(K-R 20) 0.78, defficulty index 49.13%, discrimination index 0.42, mean achivement 61.85%, standard deviation 5.11, and standard error 2.40. Considering the above results, the developed instrument in this study is regarded as a appropriate instrument for evaluating science inquiry skills of elementary school students.

  • PDF

Precise Baseline Measurement and Computation of Correction Factor For EDM Instrument Calibration (EDM 장비의 검교정을 위한 정밀 기선장 관측 및 보정계수 산정)

  • 조재명;윤홍식;이원춘
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.83-89
    • /
    • 2004
  • The electronic distance measurement instrument, first introduced in the 1950s has, since those early days, undergone continual refinement. Rapid advances in related technologies have provided lighter, smaller and more precise equipment. Understanding for the principle, the standardized observation technique and the precision of EDM instrument is mostly important to improve the quality and the reliability of by-product in the field of engineering and industrial surveying. Simple and accurate calibration is regularly and periodically necessary to maintenance the precision of EDM instrument. This paper describes the calculated example of zero error and scale error as a correction of EDM by applying the least square method to baseline observations. Here we deals also with the testing criteria for precision instrument testing according to different types of EDM instruments.

  • PDF

Development of Seismic Monitoring Analysis System for HANARO (하나로 지진감시 분석시스템 개발)

  • 류정수;김형규;윤두병
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.330-337
    • /
    • 2002
  • The HANARO seismic monitoring system is classified as non-nuclear safety(NNS), seismic category I, and quality class T The seismic monitoring system installed at the instrument room consists of five field sensors and one monitoring cabinet. The field sensors are composed of three triaxial accelerometers which installed at base slab, free field and overhead crane support respectively, a seismic trigger and a seismic switch at base slab. The most parts of analog system except field sensors are not produced any more, the improvement of the system is to be needed. The analog system with magnetic tape recorder is not only out-of-date model but dependent upon foreign technology. So it is difficult to get the spare parts and the cost to buy them is increased. Therefore we have improved the analog seismic monitoring system into a new digital seismic monitoring analysis system(SMAS) except five field sensors. After the installation of the new SMAS, we have carried out the site acceptance test(SAT) to confirm the field functions. The results of SAT satisfy the requirements of the fabrication technical specification. This new SMAS is operating at HANARO instrument room to acquire and analyse the signal of earthquake.

  • PDF

The Research of Design Development for Strengthening Competitiveness of Domestic Medical Instrument Industry -Focused on C-Arm Surgical X-Ray Design- (국내 의료기기산업 경쟁력 강화를 위한 디자인개발에 관한 연구 -이동형 영상진단기기 디자인을 중심으로-)

  • Han, Il-Woo
    • Archives of design research
    • /
    • v.17 no.4
    • /
    • pp.51-60
    • /
    • 2004
  • The medical instrument industry which is one of the high value added industry has been neglected on the various system and political support because it has been recognized as an unknown field to the public although it is the very easy-approaching field for the export market that minimize a technological gap between advanced country and Korea. Especially, the product design that is very important element for the efficient medical treatment and the psychological stabilization of patient is a typical field of lack of investment and support by the unconcern and lack of understanding of design. Therefore this research suggests the current problem of design with the general inquiry of internal and external market situation and domestic medical instrument industry and also it has the conclusion of an alternative proposal for the solution with the design development processing of a moving type-image diagnostic equipment. We will emboss the importance of design competitiveness, suggest the model and basic data to the medical instrument company that starts later, and be a role of inspiration for the lasting investible desire with this research.

  • PDF

KMAG payload instrument of Korea Pathfinder Lunar Orbiter

  • Jin, Ho;Kim, Khan-Hyuck;Son, Derac;Lee, Seongwhan;Lee, Hyojeong;Lee, Jung-Kyu;Lee, Mangyu;Lee, Seungah;Shin, Jehyuck;Garrick-Bethell, Ian
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.89.2-89.2
    • /
    • 2017
  • Korea Pathfinder Lunar Orbiter (KPLO) is a first Korean Lunar exploration mission. KPLO is equipped with four payloads in Korea and one payload in United States. KMAG is one of Korean payloads to measure the Moon's magnetic field. Moon has a no dipole magnetic field such as earth's global magnetic field. But there are many curious crustal magnetic anomalies. these features still do not well understood. This is a main scientific objective of KMAG payload and the study of space environment around moon is a second objective. KMAG has three magnetometers which are mounted in the edge of the 1.2 meter boom. This paper shows a KMAG's requirements, instrument description, and a preliminary function test results.

  • PDF

DEVELOPMENT STATUS OF THE DOTIFS DATA SIMULATOR AND THE REDUCTION PACKAGE

  • CHUNG, HAEUN;RAMAPRAKASH, A.N.;PARK, CHANGBOM
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.675-677
    • /
    • 2015
  • A data simulator and reduction package for the Devasthal Optical Telescope Integral Field Spectrograph (DOTIFS) has been developed. Since data reduction for the Integral Field Spectrograph (IFS) requires complicated procedures due to the complex nature of the integral spectrograph, common reduction procedures are usually not directly applicable for such an instrument. Therefore, the development of an optimized package for the DOTIFS is required. The data simulator observes artificial object and simulates CCD images for the instrument considering various effects; e.g. atmosphere, sky background, transmission, spectrograph optics aberration, and detector noise. The data reduction package has been developed based on the outcomes from the DOTIFS data simulator. The reduction package includes the entire processes for the reduction; pre-processing, flat-fielding, and sky subtraction. It generates 3D data cubes as a final product, which users can use for science directly.

Development of Measurement Assurance Test Procedures between Calibrations (계기 검교정간의 보증시험 절차의 개발)

  • Yum, Bong-Jin;Cho, Jae-Gyeun;Lee, Dong-Wha
    • IE interfaces
    • /
    • v.6 no.1
    • /
    • pp.55-65
    • /
    • 1993
  • A nonstandard instrument used in the filed frequently becomes out-of-calibration due to environmental noise, misuse, aging, etc. A substantial amount of loss may result if such nonstandard instrument is used to check product quality and performance. Traditional periodic calibration at the calibration center is not capable of detecting out-of-calibration status while the instrument is in use, and therefore, statistical methods need to be developed to check the status of a nonstandard instrument in the field between calibrations. Developed in this paper is a unified measurement assurance model in which statistical calibration at the calibration center and measurement assurance test in the filed are combined. We developed statistical procedures to detect changes in precision and in the coefficients of the calibration equation. Futher, computational experiments are conducted to evaluate how the power of test varies with respect to the parameters involved. Based upon the computational results we suggest procedures for designing effective measurement assurance tests.

  • PDF

Seaworthiness of the Ship in UNCITRAL Draft Instrument and in Korean Commercial Act Act (해상법(海商法)상의 선박 감항능력 확보 의무와 UNCITRAL 운송법 초안상의 선박 감항능력 유지 의무)

  • Lim, Chae-Hyun
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.94-97
    • /
    • 2005
  • Seaworthiness is an important part of the carrier's obligation in the carriage of goods by sea. Especially seaworthiness of the ship is one of the most important obligations of the carrier in the field of international transport law. Therefore it will be important to examine the expected impacts by adopting a continuing duty of seaworthiness in UNCITRAL Draft Instrument from the Korea point of view because Korean Commercial Act provides that carriers are only obliged to exercise due diligence to make the ship seaworthy before and at the beginning of the voyage. This paper examines the concept of the seaworthiness and analyses the provisions of the Draft Instrument for the duty of seaworthiness in comparison with the Korean Commercial Act.

  • PDF

Development of Rain Gauge and Observation Error (우량계 개발과 측정 오차)

  • 김대원;이부용
    • Journal of Environmental Science International
    • /
    • v.11 no.10
    • /
    • pp.1055-1060
    • /
    • 2002
  • A new method of automatic recording raingauge is developed to measure rainfall 1200mm full scale with high accuracy and resolution. The principle of new instrument is to detect a weight change of a buoyant weight according to a change in water level of raingauge measured by the use of a strain gauge load cell. This method has the advantage of increasing measurement accuracy, since no moving equipment is used. Laboratory test of the instrument was recorded 0.4% error of 190mm rainfall amount. The validity of new instrument was examined by comparing its measured values with values recorded by automatic weather station on June 24 to 25 2001 at Daegu Meteorological Station, when there is 148.3mm rainfall amount. In spite of much rainfall there is only 0.77mm difference of total rainfall amount. This instrument was accomplished high accuracy and resolution at field test in much rainy day.

Transferring Calibrations Between on Farm Whole Grain NIR Analysers

  • Clancy, Phillip J.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1210-1210
    • /
    • 2001
  • On farm analysis of protein, moisture and oil in cereals and oil seeds is quickly being adopted by Australian farmers. The benefits of being able to measure protein and oil in grains and oil seeds are several : $\square$ Optimize crop payments $\square$ Monitor effects of fertilization $\square$ Blend on farm to meet market requirements $\square$ Off farm marketing - sell crop with load by load analysis However farmers are not NIR spectroscopists and the process of calibrating instruments has to the duty of the supplier. With the potential number of On Farm analyser being in the thousands, then the task of calibrating each instrument would be impossible, let alone the problems encountered with updating calibrations from season to season. As such, NIR technology Australia has developed a mechanism for \ulcorner\ulcorner\ulcorner their range of Cropscan 2000G NIR analysers so that a single calibration can be transferred from the master instrument to every slave instrument. Whole grain analysis has been developed over the last 10 years using Near Infrared Transmission through a sample of grain with a pathlength varying from 5-30mm. A continuous spectrum from 800-1100nm is the optimal wavelength coverage fro these applications and a grating based spectrophotometer has proven to provide the best means of producing this spectrum. The most important aspect of standardizing NIB instruments is to duplicate the spectral information. The task is to align spectrum from the slave instruments to the master instrument in terms of wavelength positioning and then to adjust the spectral response at each wavelength in order that the slave instruments mimic the master instrument. The Cropscan 2000G and 2000B Whole Grain Analyser use flat field spectrographs to produce a spectrum from 720-1100nm and a silicon photodiode array detector to collect the spectrum at approximately 10nm intervals. The concave holographic gratings used in the flat field spectrographs are produced by a process of photo lithography. As such each grating is an exact replica of the original. To align wavelengths in these instruments, NIR wheat sample scanned on the master and the slave instruments provides three check points in the spectrum to make a more exact alignment. Once the wavelengths are matched then many samples of wheat, approximately 10, exhibiting absorbances from 2 to 4.5 Abu, are scanned on the master and then on each slave. Using a simple linear regression technique, a slope and bias adjustment is made for each pixel of the detector. This process corrects the spectral response at each wavelength so that the slave instruments produce the same spectra as the master instrument. It is important to use as broad a range of absorbances in the samples so that a good slope and bias estimate can be calculated. These Slope and Bias (S'||'&'||'B) factors are then downloaded into the slave instruments. Calibrations developed on the master instrument can then be downloaded onto the slave instruments and perform similarly to the master instrument. The data shown in this paper illustrates the process of calculating these S'||'&'||'B factors and the transfer of calibrations for wheat, barley and sorghum between several instruments.

  • PDF