• Title/Summary/Keyword: field engineers

Search Result 11,916, Processing Time 0.036 seconds

The Formation of Reserved Field Configuration with Bias Field and Radio-Frequency Rotating Field (바이어스 자계와 고주파 회전자계에 의한 역전자계 배위 형성)

  • 채규훈;김동필
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.10
    • /
    • pp.840-847
    • /
    • 1989
  • It is an important problem that the plasma of high B value is to be confined safely in the research of plasma fusion. So, the Reversed Field Pinch (RFP) plasma has been studied. RFP is stable pinch having self-reversal phenomenon that forms reversed field of itself, but its process of formation is unstable. Therefore, in this paper, we configured the stable RFP by supplying the radio-frequency rotating field just before the RFP is configured by self-reversal phenomenon. Moreover, when conductivity wall is used, toroidal configured by self-reversal phenomenon. Moreover, when conductivity wall is used, toroidal flux is subject to heavy fluctuation in case of high bias field compared with low bias field.

A Study on the Formation of Reversed Field configuration stability with Radio Rotating Field (고주파 회전자계를 이용한 역전자계 배위 안정성연구)

  • Kim, Won-Sop;Hwang, Jong-Sun;Kim, Jeong-Man;Kim, Young-Min
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.121-124
    • /
    • 2006
  • It is widely know that one of the most important tasks is the research of plasma for the purpose o nuclear fusion, is to make a stable confinement of high ${\beta}$ value plasma. And, for making the stable confinement, pinch pl-asma produced by reversed field has been mainly studied yet. Magnetic field has been used to hold plasma at high temperature for a long time. Reverse field has shown unstable process. Using ratio frequency, the author could control the instability of the process and formed a stable erversed field. Inthe experiment let a reversed field configuration from by adding-Bias field in advance.

  • PDF

Voltage Control Strategy for Maximum Torque Operation of Field Oriented Induction Machine in the Field Weakening Region (전압 궤환 제어를 위한 약계자 영역에서의 벡터 제어 유도전동기의 최대 토오크 운전)

  • 김상훈;설승기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1084-1092
    • /
    • 1994
  • An induction machine can be operated in the constant power region over an extended high speed range by means of field weakening. A conventional field weakening method is to set the flux reference inversely proportional to the rotor speed. With this method, however, the machines can't yield the maximum torque over the entire high speed range. In this paper, a new field weakening method for the field oriented induction machine drive by the voltage control strategy is presented. The proposed scheme ensures not only producting the maximum torque over the entire field weakening region but also the robust control independent on machine parameters. Also the smooth transition into the field weakening operation and fast dynamic response during transient operation can be obtained. Simulation and experimental results from a 3hp laboratory induction motor drive system are done to confirm the proposed control algorithm.

Measurement and Analysis of the Atmospheric Electric Field using Balloon-Carried E-Field Sensor (비양기구로 운반되는 전계센서를 이용한 대기전계의 측정과 분석)

  • Kim, Seung-Min;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.78-84
    • /
    • 2016
  • This paper is focused on the measurement and analysis of an atmospheric electric field which is caused by thunderclouds. The electric field due to thunderclouds changes very slowly. For this reason, the extremely low frequency E-field sensor needs to be used for measuring the atmospheric electric field strength. The balloon-carried E-field sensor system with the time constant of 1sec was designed and fabricated. The electric field sensor consists of $100mm{\times}100mm$ copper plate, active integrator, high pass and low pass filters and batteries. The measurements of atmospheric electric fields were made by the balloon-carried E-field sensor and radiosonde, which sends the data back to ground in real time. From the calibration experiments, the response sensitivity of the E-field sensor was 0.154mV/kV/m in the frequency range of less than 1kHz. As a result from the actual experiment of the atmospheric electric field, the electric field signals were observed from the altitude of about 2.5km. Also, as the altitude was increased, the detected electric field wave oscillated with the fluctuation of sensing plate. The proposed method seems suitable for measurements of atmospheric electric fields, because it is inexpensive, simple to use and launch.

Core Losses of Amorphous Fe-B-Si Alloy for Transformer Core (변압기 철심용 Fe-B-Si비정질 합금의 철손 특성)

  • 김기욱;송재성;홍진완;강원구
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.1
    • /
    • pp.67-72
    • /
    • 1991
  • For improving the magnetic properties of the amorphous Fe-B-Si alloy, we annealed the sample in a magnetic field oriented in the plane of the ribbon longitudinal to its long axis. By field annealing, coercive force and total core loss are reduced from 0.04 Oe to 0.02 Oe, and from 0.25 watt/kg to 0.15 watt/kg respectively in comparsion with non-field annealed specimen. These reductions were caused by the formation of 180 dcmain wall parallel to the annealing field due to the induced anisotropy.

Irrigation water temperature and cold water damage of paddy (관개수온과 벼의 냉수피해)

  • 정상옥;오창준
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.14-21
    • /
    • 1998
  • In 1996, a cold-water damage occured in the paddy field at downstream of the Unmoon dam. To study the cause and the preventive measures of the cold-water damage a field study was performed during the growing season of 1997. Field measurements such as water temperatures at reservoir, irrigation canal and in the paddy field were made. As a result, there was no cold-water damage due to the right irrigation water management practice in 1997. The cold-water damage is passible to happen, however, and the preventive measures were provided.

  • PDF

Study on the Driving property of planar gate light source (전계방출 광원용 플라나 게이트의 구동 특성 연구)

  • Kim, Kwang-Bok;Yang, Dong-Wook;Kim, Tae-Hyeon;Kim, Dae-Jun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.148-150
    • /
    • 2008
  • In this paper, we report the improved driving methode using planar-gate for field emission light source. Due to the cold cathode in field emission device, it has advantage for driving system in terms of high speed pulse driving with narrow duty ratio. This paper shows that our driving method offers the stable and reliable driving system without rapid electric field variation for field emission light source.

  • PDF

The Derivation of Variation Equations for the Discharge Current and the Luminous Flux of Flourescent Lamp Plasma in a Transverse Magnetic Field. (전자장내 플라즈마의 전류 및 광속에 대한 변화식 유도)

  • 지철근;여인선;박왕렬
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.10
    • /
    • pp.384-388
    • /
    • 1985
  • In this paper, an attempt is made to derive the variation equatios of the discharge current and the luminous flux for flourescent lamp subjected to a transverse magnetic field. As the field increases, so do the electric field, the electron temperature, and the luminous flux, while the current decreases. The theory is in a reasonable agreement with the experimental results, taking account of many approximations and restrictions.

  • PDF

Indoor Localization System for Field Robot System of Power Plant Facilities Surveillance (발전 설비 감시 점검용 로봇 시스템을 위한 실내 위치 인식 시스템 설계)

  • Jeong, Chang-Ki;Lee, Jae-Kyung;Park, Joon-Young;Cho, Byung-Hak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2308-2312
    • /
    • 2008
  • As power plant facilities are being deteriorated, their safety is getting more important, and more routine surveillance is being required. For this purpose, this paper presents an indoor localization system for field robot system which performs the surveillance of power plant facilities instead of human workers from the viewpoint of the workers' safety and work efficiency.

Electrical Characteristics of Polymer Insulators with Field Aging (현장열화에 따른 폴리미애자의 전기적 특성)

  • 한재홍;이병성;김찬영;한용희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.522-525
    • /
    • 1999
  • The electrical characteristics of 3 year field-aged polymer insulators which dismounted from five regions were investigated. There was a little difference in PD inception voltage depending on the manufacturers and the regions. The results between PD and SD showed a close relation. There were no significant changes in electrical properties. So, it can be considered that the field-aged insulators are sound for the present.

  • PDF