• 제목/요약/키워드: field coefficient

검색결과 2,144건 처리시간 0.028초

MFSC: Mean-Field-Theory and Spreading-Coefficient Based Degree Distribution Analysis in Social Network

  • Lin, Chongze;Zheng, Yi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권8호
    • /
    • pp.3630-3656
    • /
    • 2018
  • Degree distribution can provide basic information for structural characteristics and internal relationship in social network. It is a critical procedure for social network topology analysis. In this paper, based on the mean-field theory, we study a special type of social network with exponential distribution of time intervals. First of all, in order to improve the accuracy of analysis, we propose a spreading coefficient algorithm based on intimate relationship, which determines the number of the joined members through the intimacy among members. Then, simulation show that the degree distribution of follows the power-law distribution and has small-world characteristics. Finally, we compare the performance of our algorithm with the existing algorithms, and find that our algorithm improves the accuracy of degree distribution as well as reducing the time complexity significantly, which can complete 29.04% higher precision and 40.94% lower implementation time.

근접장 마이크로파 현미경을 이용한 Copper(II)-phthalocyanine 박막의 특성 연구 (Characterization of thin film properties of Copper(II)-Phthalocyanine using a near-field scanning microwave microscope)

  • 박미화;이기진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.460-463
    • /
    • 2003
  • We report the microwave reflection coefficient $S_{11}$ of copper(II)-phthalocyanine(CuPc) using a near-field microwave microscope(NSMM) in order to understand the intrinsic electromagnetic properties of organic materials. For a NSMM system, a high-quility microstip resonator coupled with a dielectric resonator was used. The reflection coefficient $S_{11}$ was changed by the preparation conditions of CuPc thin films. We compared the reflection coefficient with crystal phase, surface morphology, UV absorption spectra and x-ray diffraction results.

  • PDF

수직입사 임피던스를 이용한 난입사 흡음율 예측 연구 (The study on the estimation of diffuse field absorption coefficient by using normal incidence impedance)

  • 유승국;김영찬;김두훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.643-649
    • /
    • 1998
  • This paper is to compare the absorption coefficient with normal incidence waves and it with diffuse incidence waves of glass wool which the most used absorption material and multi layer fiber. The absorption coefficient with normal incidence waves is calculated by surface impedance that measured by using an acoustic tube. Based on this data, the absorption. coefficient with diffuse incidence waves is predicted and is compared with measured the absorption coefficient in reverberation room.

  • PDF

현장수준의 축산폐수처리에 있어서 계절별 농도 및 온도변화에 따른 분해반응계수 및 온도보정계수의 산정 (Assessment of Degradation Rate Coefficient and Temperature Correction Factor by Seasonal Variation of Concentration and Temperature in Livestock Wastewater Treatment in Field Scale)

  • 박석환
    • 한국환경보건학회지
    • /
    • 제22권2호
    • /
    • pp.90-95
    • /
    • 1996
  • This study was performed to calculate the degration rate coefficient, operating parameters to meet the effluent standards, and the temperature adjustment coefficients to each parameter of pollution by seasonal variation of concentration and temperature of influent in livestock wastewater treatment by sequencing batch reactor process in field scale. The followings are the conclusions that were derived from this study. 1. In the field, temperature of livestock wastewater in reactor was 20.3$\circ$C in summer and 6.0$\circ$C in winter. The ratio of BOD:TKN: T-P in influent was 100:80:7. BOD loadings in winter and spring were 0.26 and 0.43 kg $BOD/m^3$ day, respectively. Those in summer and fall were 0.25 and 0.13 kg $BOD/m^3$ day, respectively. 2. The degradation rate coefficient for TKN was larger in summer and fall in which temperature was high than that in which temperature was high than that in winter and spring in which concentration was high. On the contrary, the phosphorus uptake rate was larger in winter and spring than that in summer and fall. 3. The hydraulic retention time in winter and spring was longer than that in summer and fall. Especially, in order to meet the standard for TKN of 120 mg/l in winter in which temperature of wastewater was 6.0$\circ$C, as the MLSS concentration was increased from 4, 000 to 7, 000 mg/l, the hydraulic retention time was increased from 212 to 121 hours. But, in order to shorten that less than 121 hours for the economical wastewater treatment, countermeasure to increase temperature of wastewater in the reactor should be considered. 4. the temperature adjustment coefficients for BOD, $COD_{Mn}$, TKN and T-P were 1.0241, 1.0225, 1.0541 and 1.0495, respectively. Namely, the treatment of TKN was most sensitively affected by temperature. For the purpose of the effective removal of nitrogen and phosphorus which are sensitive to temperature, it is necessary to keep the temperature of livestock wastewater more than 20$\circ$C which is the temperature of it in summer.

  • PDF

피에조콘 소산곡선을 이용한 연약지반의 압밀계수 산정 (Estimation of coefficient of consolidation in soft soils using PCPT dissipation results)

  • 서경범;조성환;이준환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1015-1023
    • /
    • 2010
  • While various PCPT-based methods for the analysis of consolidation were developed, additional laboratory test is needed to estimate the coefficient of consolidation. In this paper, hyperbolic method using PCPT dissipation curve for the estimation of coefficient of consolidation was proposed. To verify proposed method, field settlement test data and PCPT dissipation test data at same site were collected and analyzed. It is observed that proposed method shows good agreement with measured field settlement data.

  • PDF

병원 내 다양한 구역의 미끄럼 위험성 평가 연구 (The Evaluation for Slip Risk of Various Hospital's zones)

  • 강현수;박범
    • 대한안전경영과학회지
    • /
    • 제18권3호
    • /
    • pp.81-89
    • /
    • 2016
  • Floor slipperiness is a leading cause in slip and fall accidents which are a major source of occupational injuries in Korea. Researchers have estimated the slip and fall related accidents rank number one or two in number of the injured. The objectives of this study were to find the field contamination effect and improvement countermeasure. Slipping and falling are common accidents in large public facilities, especially facility which vulnerable adults generally use as like hospital. So, we measured the coefficient of friction of several floors on the floor in hospital, under dry and wet using BOT-3000. The results of the coefficient of friction measurements showed that floor type and surface conditions were all significant factors affecting the coefficient of friction. The most surprising finding of this study was that there were significant friction improvement when the floors were properly cleaned with cleaning equipments.

전력선 유도 환경에서의 지면 반사계 영향 분석 (Earth Reflection Effect Analysis in the Environment of Line Source Induction)

  • 이상무
    • 전자공학회논문지
    • /
    • 제50권4호
    • /
    • pp.26-32
    • /
    • 2013
  • 전력선에 의한 전자유도 환경에서 가장 보편적 영향 요인이라 할 수 있는 대지의 유도전압 감쇠 효과에 대하여 분석하였다. 전력선은 원통좌표계의 라인소스로 표현되고 계의 분석은 베셀함수와 웨이브 트랜스포메이션에 의한 이의 변형 적용을 통하여 해석된다. 라인소스로부터 방사된 전자계는 지표면에서 반사되어 관측점의 피유도원 매체에 합성되는데 이것의 영향을 알기 위하여 본 논문에서는 베셀함수에 의한 지면 반사계수를 직접 구하여 산출하도록 적용하였다. 본 논문에서 설계된 통상의 유도 환경의 배치 관계에 따르면 지면반사에 의한 원천 유도원 전압과의 합성 효율은 유도전압을 감쇠시키는 차폐효과로서 60~70%정도의 범위를 나타내었다.

연직드레인 공법에 의한 연약지반의 압밀거동 (Consolidation Behavior of Soft Ground by prefabricated Vertical Drains)

  • 이달원
    • 한국농공학회지
    • /
    • 제42권5호
    • /
    • pp.133-143
    • /
    • 2000
  • A large scale field test of prefabricated vertical drains was performed to anayze the effect of parameters of the very soft clay at a test site. compression index and the coefficient of horizontal consolidation obtained by back-analysis of settlement data were compared with those obtained by means of laboratory tests. Hyperbolic method, Asaoka meoth and curve fitting method were used to compute final settlement of coefficient of consolidation. The relationships of settlement measurement(Sm) versus design settlement(St) and the measurement consolidation ratio(Um) versus design consolidation (Ut) were shown as Sm=(1.0~1.1) St , Um=(1.13~1.17) Ut at 1.0m spacing of drain and Sm=(0.7~0.8)St, Um= (0.92~0.99) Ut at 1.5 m spacing of drain, respectively . The relationships of the field compression index(CcField) and virgin compression index(vcc lab) were shown as Ccfield =(1.0~1.2)vcc lab . But it was nearly within the same range when considering the error factor with the determination method of virgin compression index and the prediction back-analysis of the settlement data was larger than the coefficient of vertical consolidation, and the ratio of consolidation coefficient (Ch/Cv) was Ch =(2.4~2.9) Cv , Ch=(3.4~4.2) Cv at 1.0m and 1.5m spacing of drain, respectively.

  • PDF

비대칭 마그네트론 스퍼터링법에 의한 비정질 질화탄소 박막의 합성 및 윤활 특성 (Synthesis and Lubricant Properties of Nitrogen doped Amorphous Carbon (a-C:N) Thin Films by Closed-field unbalanced Magnetron Sputtering Method)

  • 박용섭;조형준;최원석;홍병유
    • 한국전기전자재료학회논문지
    • /
    • 제20권8호
    • /
    • pp.701-705
    • /
    • 2007
  • The incorporation of N in a-C film is able to improve the friction coefficient and the adhesion to various substrates. In this study, a-C:N films were deposited on Si and steel substrates by closed-field unbalanced magnetron (CFUBM) sputtering system in $Ar/N_2$ plasma. The lubricant characteristics was investigated for a-C:N deposited with total working pressure from 4 to 7 mTorr. We obtained high hardness up to 24GPa, friction coefficient lower than 0.1 and the smooth surface of having the extremely low roughness (0.16 nm). The physcial properties of a-C:N thin film are related to the increase of cross-linked $sp^2$ bonding clusters in the film. However, the decrease of hardness, elastic modulus and the increase of surface roughness, friction coefficient with the increase of $N_2$ partial pressrue might be due to the effect of energetic ions as a result of the increase of ion bombardment with the increase of ion density in the plasma.

원전 콘크리트 구조물의 중성화 진행 예측 기법에 관한 연구 (A Study on the Prediction Method of Carbonation Process for Concrete Structures of Nuclear Power Plant)

  • 고경택;김도겸;김성욱;조명석;송영철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.149-158
    • /
    • 2002
  • The carbonation process is affected by both the concrete material properties such as W/C ratio, types of cement and aggregates, admixture characteristics and the environmental factors such as $CO_2$ concentration, temperature, humidity. Based on results of preliminary study on carbonation, this study is to develop a carbonation prediction model by taking account of $CO_2$ concentration, temperature, humidity ad W/C ratio among major factor affecting the carbonation process. And to constitute a model formula which correspond to the mix design of the nuclear power plant, test coefficient that correspond to the design of the nuclear power plant is obtained based on the results of accelerated carbonation test. Also a field coefficient which is obtained based on results of the field examination is included to improve the conformity of the actual structures of nuclear power plant.