• Title/Summary/Keyword: field calibration

Search Result 644, Processing Time 0.027 seconds

Development of Packer-Dilatometer Method (팩커를 이용한 공내재하 시험 방법 개발)

  • Kern Shin Yoon
    • The Journal of Engineering Geology
    • /
    • v.8 no.2
    • /
    • pp.189-203
    • /
    • 1998
  • Packer-dilatometer techniques, which are borehole-dilatometer techniques using commercial rubber packer, were developed to measure the deformability of rocks. Packer-dilatometers for 0.5 inch, AX, BX, NX and HX size boreholes were developed and were used for rock deformability measurements in the field. In the packer-dilatometer method, the packer pressurizes the borehole-wall and the borehole deformation is determined by the amount of fluid injected into the packer. A detailed description of the theoretical development of quantitative interpretation of the packer-dilatometer method; apparatus, setup and procedures for the determining of calibration constants; contact pressure determination and field tests using the packer-dilatometer are provided.

  • PDF

Quantitative Vapor Phase Exciplex Fluorescence Measurements at High Ambient Temperature and Pressure

  • Kim, Tongwoo;Jaal B. Ghandhi
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.157-167
    • /
    • 2003
  • The exciplex fluorescence technique with the TMPD (tetamethyl-Ρ-phenylene-diamine) / naphthalene dopant system was applied in a combustion-type constant-volume spray chamber. A detailed set of calibration experiments has been performed in order to quantify the TMPD fluorescence signal. It has been demonstrated that the TMPD fluorescence intensity was directly proportional to concentration, was independent of the chamber pressure, and was not sensitive to quenching by either water vapor or carbon dioxide. Using a dual heated-jet experiment, the temperature dependence of TMPD fluorescence up to 1000 K was measured. The temperature field in the spray images was determined using a simple mixing model, and an iterative solution method was used to determine the concentration and temperature field including the additional effects of the laser sheet extinction. The integrated fuel vapor concentration compared favorably with the measured amount of injected fuel when all of the liquid fuel had evaporated.

Planar-type Electric Field Sensor for Measuring the Time-varying Electric Fields (시변전계 측정용 평판형 전계센서)

  • Lee, Bok-Hee;Lee, Sung-Hun;Kil, Gyung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.287-289
    • /
    • 1994
  • This paper deals with the planar-type electric field sensor which can measure the time-varying electric fields. The theoretical principle and design rule of the sensor are introduced, and also the calibration and application investigations are carried out. From the calibration experiments, the frequency bandwidth of the measurement system ranges from 160 [Hz] to 25 [MHz]. At a high voltage laboratory, the electric fields caused by the impulse voltage and oscillating transient voltage are measured by the proposed sensor. Obtained results are well agreement with the applied voltage waveforms.

  • PDF

Elution Behavior of Protein and Pullulan in Asymmetrical Flow Field-flow Fractionation (AsFlFFF)

  • Ji, Eun-Sun;Choe, Seong-Ho;Yun, Guk-Ro;Chun, Jong-Han;Lee, Seung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.9
    • /
    • pp.1433-1438
    • /
    • 2006
  • An AsFlFFF channel was designed and built, and then tested for analysis of pullulans and proteins. Pullulans and proteins having various nominal molecular weights were injected at various conditions of the cross-flow rate ($F_c$) and the channel-out flow rate ($F_{out}$). The retention (measured by the retention ratio R) and the zone broadening (measured by the plate height H) were measured, and then compared with theory. When the incoming flow rate, $f_{in}$ (and thus $F_{out}$) was varied with $F_c$ fixed at 2.5 mL/min, the plate height measured for the pullulan with nominal molecular weight (M) of about 100,000 showed the trend expected by the longitudinal diffusion theory (H decreases with increasing flow rate). In contrast, when $F_{out}$ was varied with the flow rate ratio, $F_c/F_{out}$, fixed constant at 5, the plate height measured for the same sample showed the trend expected from the non-equilibrium theory (H increases with increasing flow rate). Calibration plots (log D vs. log M) obtained with pullulans and proteins were not coincide, probably due to the difference in molecular conformation, suggesting the analysis of pullulans and proteins using AsFlFFF requires independent calibration. It was found that the linearity of the protein-calibration plot was improved by using a buffer solution as the carrier.

Calibration and Performance Test of Hot-wire Anemometers by Using a Calibration Wind Tunnel (풍동장치를 이용한 열선풍소계의 보정 및 실태 평가)

  • Ha, Hyun-Chul;Kim, Tae-Hyeung;Kim, Eun-A;Kim, Jong-Chul;Oh, Jung-Ryng;Jung, Ho-Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.2
    • /
    • pp.110-122
    • /
    • 1999
  • Hot-wire anemometers are most commonly used in measuring hood capture velocities due to their accuracy and convenience. But it was questionable that the anemometers being used in the field are accurate enough for the purpose of measurements. To answer this ques tion, a calibration wind tunnel was newly devised and tested. Subsequently, 53 hot-wire anemometers being currently used in the field were tested to evaluate the accuracy of anemometers. The average error was 16.93% while the average errors in the low (0.5~5m/s) and high (5~20m/s) velocity range were 17.40% and 16.45%, respectively. Most of anemometers underestimated the true velocities. It might be due to the contamination of hot-wire, resulting in the slow heat transfer between the sensor and air flow. Astonishingly, 16 of 53 anemometers were out of order due to the malfunctioning of zero adjustment control, power supply, display panel and sensor. It is desirable to calibrate periodically and clean the sensor after using in the dirty environment.

  • PDF

A comparative analysis of structural damage detection techniques by wavelet, kurtosis and pseudofractal methods

  • Pakrashi, Vikram;O'Connor, Alan;Basu, Biswajit
    • Structural Engineering and Mechanics
    • /
    • v.32 no.4
    • /
    • pp.489-500
    • /
    • 2009
  • The aim of this paper is to compare wavelet, kurtosis and pseudofractal based techniques for structural health monitoring in the presence of measurement noise. A detailed comparison and assessment of these techniques have been carried out in this paper through numerical experiments for the calibration of damage extent of a simply supported beam with an open crack serving as an illustrative example. The numerical experiments are deemed critical due to limited amount of experimental data available in the field of singularity based detection of damage. A continuous detectibility map has been proposed for comparing various techniques qualitatively. Efficiency surfaces have been constructed for wavelet, kurtosis and pseudofractal based calibration of damage extent as a function of damage location and measurement noise level. Levels of noise have been identified for each technique where a sudden drop of calibration efficiency is observed marking the onset of damage masking regime by measurement noise.

A Switched Visual Servoing Technique Robust to Camera Calibration Errors for Reaching the Desired Location Following a Straight Line in 3-D Space (카메라 교정 오차에 강인한 3차원 직선 경로 추종을 위한 전환 비주얼 서보잉 기법)

  • Kim, Do-Hyoung;Chung, Myung-Jin
    • The Journal of Korea Robotics Society
    • /
    • v.1 no.2
    • /
    • pp.125-134
    • /
    • 2006
  • The problem of establishing the servo system to reach the desired location keeping all features in the field of view and following a straight line is considered. In addition, robustness of camera calibration parameters is considered in this paper. The proposed approach is based on switching from position-based visual servoing (PBVS) to image-based visual servoing (IBVS) and allows the camera path to follow a straight line. To achieve the objective, a pose estimation method is required; the camera's target pose is estimated from the obtained images without the knowledge of the object. A switched control law moves the camera equipped to a robot end-effector near the desired location following a straight line in Cartesian space and then positions it to the desired pose with robustness to camera calibration error. Finally simulation results show the feasibility of the proposed visual servoing technique.

  • PDF

Magnetic Field Measuring System by using Loop-type Sensor (루우프형 센서를 이용한 자장측정계)

  • Lee, Bok-Hee;Kil, Gyung-Suk;Park, Dong-Hwa
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.14-21
    • /
    • 1995
  • This paper deals with the active magnetic field measuring system which can measure the time-varying magnetic fields generated by power installations and lightning discharges. The magnetic field measuring system consists of the loop-type magnetic field sensor and the active integrator operated by a differential amplifier. The theoretical principle and design rule of the time-varying magnetic field measuring device and the calibration apparatus are introduced. From the calibration experiments, the frequency bandwidth of the full measuring system ranges from 270 Hz to about 2.3 MHz and the response sensitivity for magentic field strength is 128 $mV/{\mu}T$, respectively, and the calculated B-field values in the center of the loop-type sensor versus the the applied current made with a region of ${\pm}3\;%$error. The actual survey experiments by using lightning impulse current and oscillating impulse current were performed, the results of comparision between the input current waveforms and the magnetic field waveforms are a good agreement with each others and their deviations are less than 0.5 %.

  • PDF

Evaluation of Field Compaction Density by Non-nuclear Density Gauge (다짐밀도 측정장비(Non-nuclear Type)를 사용한 현장 다짐밀도 평가)

  • Kim, Yeong Min;Im, Jeong Hyuk;Yang, Sung Lin;Kim, Ki Hyun;Hwang, Sung Do;Jeong, Kyu Dong
    • International Journal of Highway Engineering
    • /
    • v.17 no.1
    • /
    • pp.51-58
    • /
    • 2015
  • PURPOSES : The objective of this study is to compare the densities of asphalt pavements measured both in the field and in the laboratory, and also to evaluate the applicability of field density measuring equipment, such as the pavement quality indicator (PQI), by using statistical analysis. METHODS : For the statistical analysis of the density measured from asphalt pavement, student t-tests and a coefficient of correlation are investigated. In order to compare the measured densities, two test sections are prepared, with a base layer and an intermediate layer constructed. Each test section consists of 9 smaller sections. During construction, the field densities are measured for both layers (base and intermediate) in each section. Core samples are extracted from similar regions in each section, and moved to the laboratory for density measurements. All the measured densities from both the field and laboratory observations are analyzed using the selected statistical analysis methods. RESULTS AND CONCLUSION : Based on an analysis of measured densities, analysis using a correlation coefficient is found to be more accurate than analysis using a student t-test. The correlation coefficient (R) between the field density and the core density is found to be very low with a confidence interval less than 0.5. This may be the result of inappropriate calibration of the measuring equipment. Additionally, the correlation coefficient for the base layer is higher than for the intermediate layer. Finally, we observe that prior to using the density measuring equipment in the field, a calibration process should be performed to ensure the reliability of measured field densities.

Study on the Calibration of a Full-Polarimetric Scatterometer System at X-band (X-밴드 완전 편파 Scatterometer 시스템 보정에 관한 연구)

  • Hwang, Ji-Hwan;Park, Seong-Min;Kwon, Soon-Gu;Oh, Yi-Sok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.4
    • /
    • pp.408-416
    • /
    • 2010
  • A study on the calibration of an X-band HPS(Hongik Polarimetric Scatterometer) system for ground-based operation is presented in this paper. In order to calibrate the scatterometer system, the degree of its distortions are analyzed by comparison between theoretical- and measured-values using the theoretically well-known calibration targets such as a metal sphere, a trihedral corner reflector(CR) and a metal cylinder. The calibration works in the field conditions depend on the precise and stable measurements of those calibration target. we present a measurement technique, so-called, an automatic 2-D target-scanning technique, using the incidence-angle(${\xi}-$ and ${\phi}-$ directions) control of HPS system. Then, we used STCT(Single-Target Calibration Technique) and GCT(General Calibration Technique) to calibrate a distortion of the scatterometer system, and measured the polarimetric RCS(Radar Cross Section) and phase-difference of a trihedral-CR as a test-target to verify the accuracy of the calibration technique. Then, three different types(i.e., 10, 20, 30 cm) of trihedral-CR were used. we obtained the error ranges about ${\pm}1.0$dB, ${\pm}0.5$ dB in a polarimetric RCS and about $-20^{\circ}{\sim}0^{\circ}$ and ${\pm}5^{\circ}$ in the co-polarized phase-difference by using the GCT and STCT, respectively.