• 제목/요약/키워드: fiber displacement sensor

검색결과 92건 처리시간 0.026초

센서유형별 측정 변형률을 이용한 철근콘크리트 보의 처짐추정에 관한 실험적 연구 (An experimental study on estimating deflection of RC beam using resistive strain gauge and fiber optic sensor)

  • 이규완;박기태;박흥석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.517-522
    • /
    • 2000
  • In the past few years, the nondestructive inspection technology has greatly developed due to the increased necessity to gain a complete understanding of the bridge behavior. Especially, the deformations of bridges contain a lot of informations about its health state. By measuring these deformations it is possible to analyze the loading and aging behavior of the structure. However, the current methods (such as LVDT, dial gage, optical displacement tranceducer, etc) are often of changeable application on site and have the limitations of installation. In this paper, the classical beam theory was reviewed and the deflections of structure are estimated using measured strain which is easy to acquire. The applicability of this algorithm is verified by a preliminary steel beam test and two types of concrete beam tests. Also fiber optic sensors as well as resistive strain gages were installed in the concrete beams to establish the applicability of fiber optic sensors in the field of civil engineering.

  • PDF

프리스트레스 측정을 위한 헤테로코어 광파이버 센서의 분해능 검증 기초실험 (Fundamental Experiment to Verify the Resolution of Hetero-core Fiber Optic Sensor for the Prestress Measurement)

  • 박익태;최광수;김태양;이환우
    • 한국전산구조공학회논문집
    • /
    • 제31권5호
    • /
    • pp.259-266
    • /
    • 2018
  • 이 실험연구는 PSC 교량의 생애주기 프리스트레스 측정용 헤테로코어 광파이버 센서를 개발하기 위한 선행연구이며, 기존의 헤테로코어 변위센서의 정밀도를 향상하기 위한 실험이다. 실험결과 최대 $2{\mu}m$ 단위의 변위 변화량을 측정할 수 있었다. 즉, 변위측정 길이가 30cm의 센서모듈을 설계했을 때 설계기준압축강도(fck)가 40MPa인 경우 0.2MPa 단위의 응력변화를 측정이 가능함을 확인하였다. 따라서 본 실험의 결과는 향후 진행될 내부매립용 센서모듈 개발에 유용한 자료로 활용될 수 있을 것으로 판단된다.

광섬유 센서를 이용한 PSC 합성형교의 응답보정계수 영향인자 분석 (Impact Factor Analysis of Response Adjustment Factor of PSC Composite Bridge Using Optical Fiber Sensor)

  • 김호선;장화섭;양동운
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.35-43
    • /
    • 2012
  • 일반적으로 교량의 하중저항능력인 내하력은 교량의 거동에 큰 영향을 줄 수 있는 심각한 손상, 결함, 재료적인 열화현상이 존재하지 않는다면 이론적인 방법으로 평가한 내하력보다 여유가 있다. 그러나 현재 내하력을 구하기위한 재하실험 및 구조해석 과정에서 이미 오차가 포함되어 있어 응답보정계수의 신뢰성이 떨어지고 있다. 이에 본 연구에서는 센서의 센싱 문제와 구조해석 모델의 적정성에 오차를 해결하기 위하여 센서부에서 기존의 전기저항식 변형률, 변위 센서의 문제점을 도출하여 성능이 우수한 스마트 센서인 광섬유 스마트 센서로의 변화를 추진하고자 한다. 또한, 다양한 구조해석 모델 해석을 통하여 최적의 적정 모델을 선정함으로서 응답보정계수의 정확성을 향상시키고자 하였다.

Active vibration control of smart composite structures in hygrothermal environment

  • Mahato, P.K.;Maiti, D.K.
    • Structural Engineering and Mechanics
    • /
    • 제44권2호
    • /
    • pp.127-138
    • /
    • 2012
  • The composite materials may be exposed to environmental (thermal or hygral or both) condition during their service life. The effect of environmental condition is usually adverse from the point of view of design of composite structures. In the present research study the effect of hygrothermal condition on the design of laminated composite structures is investigated. The active fiber composite (AFC) which may be utilized as actuator or sensor is considered in the present analysis. The sensor layer is used to sense the level of response of the composite structures. The sensed voltage is fed back to the actuator through the controller. In this study both displacement and velocity feedback controllers are employed to reduce the response of the composite laminate within acceptable limit. The Newmark direct time integration scheme is employed along with modal superposition method to improve the computational efficiency. It is observed from the numerical study that the laminated composite structures become weak in the presence of hygrothermal load. The response of the structure can be brought to the acceptable level once the AFC layer is activated through the feedback loop.

제방 안전관리를 위한 Flex센서와 FBG센서의 적용성 검토 (Suitability Examination of Flex sensor and FBG Sensor for Levee Safety Management)

  • 이인제;이은태;강정훈;김동민;장기태
    • 한국수자원학회논문집
    • /
    • 제41권11호
    • /
    • pp.1135-1142
    • /
    • 2008
  • 하천제방의 붕괴 요인중 구조물(배수통문) 주변 제방의 붕괴는 전체 요인의 l0% 이상을 차지하고 있으며, 특히 2002년 홍수시 낙동강에서 발생한 제방 유실 지점은 거의 배수통문 주위에서 발생하였다. 이러한 제방 파괴는 이질 재료인 통문 구조물과 제체 접합부 사이에 공극이나 공동이 형성된 후 홍수시 내부 침식으로 인해 공동이 확대되어 발생하는 파괴구조를 가지고 있다. 이러한 상황에서 하천제방의 안전관리를 위해 배수통문 주변의 공동발생 여부 혹은 공동내의 흐름 인지 등을 목적으로 한 연구가 진행되고 있으며, 본 연구에서는 Flex센서와 Fiber bragg grating 센서의 변이 계측에 대한 실험을 통해 두 센서의 특징을 파악하고, 하천제방의 안전관리를 위해 보다 적합한 센서의 결정이 가능하도록 하였다. 실험결과 현 시점에서 변이 계측과 관련하여 계측치의 일관성, 미소변이 계측 등 Flex센서의 단점을 보완할 수 있는 FBG센서의 여러 특징을 확인할 수 있었다.

오차 최소화된 정밀 광삼각법 프로브의 해석 및 설계 (Design & Analysis of an Error-reduced Precision Optical Triangulation Probes)

  • 김경찬;오세백;김종안;김수현;곽윤근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.411-414
    • /
    • 2000
  • Optical Triangulation Probes (OTPs) are widely used for their simple structure. high resolution, and long operating range. However, errors originating from speckle, inclination of the object, source power fluctuation, ambient light, and noise of the detector limit their usability. In this paper, we propose new design criteria for an error-reduced OTP. The light source module for the system consists of an incoherent light source and a multimode optical fiber for eliminating speckle and shaping a Gaussian beam Intensity profile. A diffuse-reflective white copy paper, which is attached to the object, makes the light intensity distribution on the change-coupled device(CCD). Since the peak positions of the intensity distribution are not related to the various error sources, a sub-pixel resolution signal processing algorithm that can detect the peak position makes it possible to construct an error-reduced OTP system

  • PDF

UsN 기반의 송전철탑 건전성 감시진단시스템 기본설계 (UsN based Soundness Monitoring Diagnosis System of Power Transmission Steel Tower)

  • 이동철;배을록;김우정;민병운
    • 전기학회논문지P
    • /
    • 제56권1호
    • /
    • pp.56-62
    • /
    • 2007
  • In this paper, design method for power tower hazard diagnosis/predition system based on UsN was proposed. The proposed method used multi-hybrid sensors to measure rotation, displacement, and inclination state of power tower, and made decision/prediction of hazard of power tower. System design was made with requirement analysis of monitoring for transmission power facility and use of MEMS and optic fiber sensors. For hazard decision, analysis of correlation was made using sensor output. LN based on IEC61850,international standard for digital substation, was also proposed. For transmission facility monitoring, digital substation and power tower were considered as parts of power facility networks.

광섬유 브래그 격자 다중화 센서 패키징 기술에 관한 연구 (Packaging Technology for the Optical Fiber Bragg Grating Multiplexed Sensors)

  • 이상매
    • 마이크로전자및패키징학회지
    • /
    • 제24권4호
    • /
    • pp.23-29
    • /
    • 2017
  • 본 연구에서는 선박이송용 트레슬의 표면에 부착할 수 있는 광섬유센서 패키지를 설계하고 파장다중분할방식에 기초한 센서 네트워크를 설계한 후, 모의 트레슬 유닛을 이용한 실험을 통하여 트레슬의 구조적 건전 모니터링을 위한 스마트 트레슬의 가능성을 확인하였다. 광섬유 브래그 격자 센서는 알루미늄 관으로 만들어진 원통형으로 패키징 되었다. 또한, 패키징 된 광섬유 센서를 폴리머 튜브에 삽입 한 후, 튜브 내부에 에폭시를 충전하여 센서가 해수에 대한 부식저항과 내구성을 갖도록 하였다. 패키지 된 광섬유 센서는 0.2 MPa 하의 수압테스트를 통하여 해수에서의 사용에 대한 신뢰성도 검증되었다. 트레슬의 변형에 관한 유한 요소 해석에 의해 얻어진 트레슬 부재의 변위가 큰 곳을 중심으로 트레슬에 부착할 브래그 격자의 수와 위치를 결정하였다. 최대 하중이 가해지는 트레슬 부재의 변형은 ${\sim}1000{\mu}{\varepsilon}$의 변형율로 분석되었으며, 그 때 트레슬에 걸리는 최대 하중으로 인한 센서의 브래그 파장 변화는 ~1,200 pm으로 계산되었다. 유한 요소 해석에서 얻은 결과에 따라 센서의 브래그 파장 간격을 3~5 nm로 결정하여 트레슬에 하중이 가해 졌을 때 센서 사이의 브래그 격자 파장값이 겹치지 않도록 설계하였다. 5개의 광섬유센서 패키지로 구성된 센서 모듈 5개를 연결하면 브래그 격자 센서 50개가 네트워크 될 수 있으므로, 브래그 격자 파장 검출기의 광원 중심 파장이 1550 nm에서 150 nm 광학 창 내에서 모두 검출될 수 있도록 하였다. 모의 트레슬 유닛에 부착 된 5개의 광섬유 센서 패키지의 브래그 파장 이동은 광섬유 루프미러를 사용하는 브래그 격자 파장검출기에 의해 잘 검출되었으며, 그 때 검출된 브래그 격자 센서의 값은 최대 변형률이 약 $235.650{\mu}{\varepsilon}$로 측정되었다. 센서 패키징과 네트워킹의 모델링 결과는 실험 결과와 서로 잘 일치하였다.

풍력발전기 블레이드 처짐 측정을 위한 다중화 센서 탐촉자 설계 제작 (Fabrication of a Multiplexing Sensor Probe for Measuring the Blade Deflection of a Wind Power Generator)

  • 김지대;이동주
    • 한국생산제조학회지
    • /
    • 제23권2호
    • /
    • pp.178-185
    • /
    • 2014
  • This paper describes a fabrication multiplexing sensor probe that employs a fiber Bragg grating(FBG) based on multiple measurements to determine the blade deflection of a wind power generator the reliability analysis of this probe is also presented. To diminish the temperature sensitivity of the FBG sensor, we form multiple CFRPs onto the upper and lower layers of the FBG and package it with an epoxy resin. As a result, the depth of the CFRP is 1mm, and the temperature sensitivity is $2.39pm/^{\circ}C$. We construct a sensor network utilizing the fabricated sensor with a blade beam model. As the number of pendulums is increased on the fore-end of the beam, the strain value is measured. The strain variation is calculated from the measurement of the load on the blade beam model by monitoring the strain of the FBG sensor. When the linear equation is applied, the strain error is 0.4% and when the finite difference method is used, the tip deflection error is 3.3%. The displacement error derived from the strain value of the FBG sensor is 4.39%. The calculated result between the measured value of the dead-end of the beam and the strain is less than 2.46% tip distortion error. Therefore, our proposed multiplexing sensor probe is a low-cost and high-reliability solution for a commercial wind power generator.

Model verification and assessment of shear-flexure interaction in pile foundations

  • Lemnitzer, Anne;Nunez, Eduardo;Massone, Leonardo M.
    • Earthquakes and Structures
    • /
    • 제11권1호
    • /
    • pp.141-163
    • /
    • 2016
  • Fiber models have been developed and applied to various structural elements such as shear walls, beams and columns. Only scarcely have fiber models been applied to circular foundation systems such as cast in drilled holes shafts (CIDH). In pile foundations with constraint head boundary conditions, shear deformations can easily contribute to the lateral pile response. However, soil structure interaction formulations such as the p-y method, commonly used for lateral pile design, do not include structural shear deformations in its traditional derivation method. A fiber model that couples shear and axial-bending behavior, originally developed for wall elements was modified and validated on circular cross sections (columns) before being applied to a 0.61 m diameter reinforced concrete (RC) pile with fixed head boundary conditions. The analytical response was compared to measured test results of a fixed head test pile to investigate the possible impact of pile shear deformations on the displacement, shear, and moment profiles of the pile. Results showed that shear displacements and forces are not negligible and suggest that nonlinear shear deformations for RC piles should be considered for fixed-head or similar conditions. Appropriate sensor layout is recommended to capture shear deformation when deriving p-y curves from field measurements.