• Title/Summary/Keyword: fiber bragg grating

Search Result 419, Processing Time 0.019 seconds

Discrimination of Temperature and Strain Using a Single Fiber Bragg Grating and an Erbium-doped Fiber Amplifier (단일 광섬유 브래그 격자와 EDFA를 이용한 온도와 스트레인의 동시 측정)

  • Jung, Jae-Hoon;Nam, Hui;Lee, Byoung-Ho
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.6
    • /
    • pp.97-101
    • /
    • 1999
  • We propose and demonstrate a novel sensor which can simultaneously measure strain and temperature. The sensor is composed of a single fiber Bragg grating and an erbium-doped fiber amplifier. Using linear variation in the amplified spontaneous emission power of an erbium-doped fiber amplifier with temperature, we determine the temperature. By subtracting the temperature effect from the Bragg wavelength shift, we determine the strain. Experiments show rms deviations of $18.2{\mu}{\varepsilon}$ and $0.7^{\circ}C$ for strain and temperature, respectively.

  • PDF

Thermal characteristics of high-temperature measurement sensor using fiber Bragg grating (FBG를 이용한 고온 측정 센서의 온도특성)

  • Son, Yong-Hwan;Han, Sang-Kook
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.261-266
    • /
    • 2008
  • In this paper, we present thermal characteristics of high-temperature measurement sensor using fiber Bragg grating(FBG), including peak reflectivity, FWHM bandwidth and various normalized refractive index change along temperature variation. The temperature stability of FBG temperature sensor can be changed by varying the refractive index change and grating length. The proposed FBG temperature sensor can measure up to about $600^{\circ}C$ and 1000 hours of heating time.

Design Scheme of FBG Sensor System for Aircraft Application (항공기 탑재를 위한 FBG 센서 장비의 설계조건 도출)

  • Park, Sang-Wuk;Yoon, Hyuk-Jin;Park, Sang-Oh;Song, Ji-Yong;Kim, Chun-Gon
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.215-218
    • /
    • 2005
  • In this research, design scheme of fiber Bragg grating(FBG) sensor system for aircraft application is suggested from the results and the know-how from the fon11er researches on structural health monitoring techniques using fiber optic sensors. Design factors to be taken into consideration were derived for both sensor parts including connection and system parts. For the stability of FBG sensor system, design requirements of temperature, vibration, humidity, electromagnetic interference were presented from U. S. military standards. The direction of software programming which increases stability and perfon11ance of the aircraft with the FBG sensor system was also examined.

  • PDF

Radiation Hardness Characteristics of Fiber Bragg Gratings on the High Temperature Annealing Condition (고온 어닐링 조건에 따른 FBG 센서의 내방사선 특성)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.10
    • /
    • pp.1980-1986
    • /
    • 2016
  • In this study, we studied the gamma-radiation effect of fiber Bragg gratings (FBGs) on the high temperature annealing condition after grating inscription using a KrF UV laser (248 nm). The FBGs were fabricated in a different annealing temperature using the same commercial Ge-doped silica core fiber (SMF-28e) and exposed to gamma-radiation up to a dose of 31 kGy at the dose rate of 115 Gy/min. The high temperature annealing procedure for grating stabilization was applied to change the radiation sensitivity of the FBGs. According to the experimental data and analysis results, the gratings that were stabilized at different temperatures at 100, 150 and $200^{\circ}C$ have clearly shown that exposure to higher temperatures increases their radiation sensitivity. The radiation-induced Bragg wavelength shift (BWS) was shown a difference of up to about a factor of two depending on the annealing temperature conditions of the gratings.

Comparison of temperature dependance between short and long period fiber gratings (단주기 광섬유 격자(Fiber Grating)와 장주기 광섬유 격자의 온도 의존성 비교)

  • Choi, Bo-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.8
    • /
    • pp.1791-1796
    • /
    • 2011
  • An optical fiber short period grating of 0.7 nm as a 3 dB wavelength linewidth was fabricated using a Gaussian distributed KrF Eximer laser and a phase mask. This grating has temperature dependancy of 0.01 nm/$^{\circ}C$ over the range of -10 $^{\circ}C$ ~ 70 $^{\circ}C$and no difference between temperature directions. An optical fiber long period grating of 14.22 nm as a 3 dB linewidth was also fabricated using a amplitude mask and has dependancy of 0.01 nm/$^{\circ}C$ over the same range.

Temperature-difference Flow Sensor Using Multiple Fiber Bragg Gratings

  • Kim, Kyunghwa;Eom, Jonghyun;Sohn, Kyungrak;Shim, Joonhwan
    • Current Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.297-303
    • /
    • 2022
  • Multiple fiber Bragg gratings (FBGs) have been proposed and demonstrated for gas-flow measurements in a flow channel, using the temperature-difference method. This sensor consists of two FBG temperature sensors and two coil heaters. Coil heaters are used to heat the FBGs. The flow rate of the gas can be obtained by monitoring the difference in the Bragg-wavelength shifts of the two FBGs, which has features that exclude the effect of temperature fluctuations. In this study, experiments are conducted to measure the wavelength shift based on the flow rate, and to evaluate the gas-flow rate in a gas tube. Experimental results show that the sensor has a linear characteristic over a flow-rate range from 0 to 25 ℓ/min. The measured sensitivity of the sensor is 3.2 pm/(ℓ/min) at a coil current of 120 mA.

Internal Strain Monitoring of Filament Wound Pressure Tanks using Embedded Fiber Bragg Grating Sensors (삽입된 광섬유 브래그 격자 센서를 이용한 필라멘트 와인딩된 복합재료 압력탱크의 내부 변형률 모니터링)

  • Kim C. U.;Park S. W.;Kim C. G.;Kang D. H.
    • Composites Research
    • /
    • v.18 no.4
    • /
    • pp.1-7
    • /
    • 2005
  • In-situ structural health monitoring of filament wound pressure tanks were conducted during water-pressurizing test using embedded fiber Bragg grating (FBG) sensors. We need to monitor inner strains during working in order to verify the health condition of pressure tanks more accurately because finite element analyses on filament wound pressure tanks usually show large differences between inner and outer strains. Fiber optic sensors, especially FBG sensors can be easily embedded into the composite structures contrary to conventional electric strain gages (ESGs). In addition, many FBG sensors can be multiplexed in single optical fiber using wavelength division multiplexing (WDM) techniques. We fabricated a standard testing and evaluation bottle (STEB) with embedded FBG sensors and performed a water-pressurizing test. In order to increase the survivability of embedded FBG sensors, we suggested a revised fabrication process for embedding FBG sensors into a filament wound pressure tank, which includes a new protecting technique of sensor heads, the grating parts. From the experimental results, it was demonstrated that FBG sensors can be successfully adapted to filament wound pressure tanks for their structural health monitoring by embedding.

Torque Measurement of Rotating Shaft Using Fiber Bragg Grating Sensors and Rotary Optical Coupler (광섬유격자센서와 회전광학커플러를 사용한 새로운 회전축의 토크 측정방법)

  • Lee, Jong-Min;Hwang, Yo-Ha
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1195-1200
    • /
    • 2007
  • Torque of a rotating shaft has been mostly measured by strain gages combined with either a slip ring or telemetry. However, these methods have severe inherent problems like low S/N ratio, high cost, limited number of channels and difficult installation. In this paper, a new method using FBG(fiber bragg grating) sensors and a rotary optical coupler for online non-contact torque monitoring is suggested. FBG sensor can measure both strain and temperature, and has much batter characteristics than those of a strain gage. A rotary optical coupler is a optical connecting device between a rotating shaft and stationary side without any physical contact. It has been devised for transmitting light between a rotating optical fiber and a stationary optical fiber. The proposed method uses this rotary optical coupler to connect FBG sensors on the rotating shaft to instruments at stationary side. And a reference FBG sensor is also applied to compensate the insertion loss change of the rotary optical coupler due to rotation. Three FBG sensors have been fabricated in a single optical fiber. Two FBG sensors are attached on the shaft surface to measure torque and one sensor is installed at the shaft center to compensate the insertion loss change. The torque of a rotating shaft has been successfully measured by the suggested method proving its superior performance potential.

Internal Strain Monitoring of Filament Wound Pressure Tanks using Embedded Fiber Bragg Grating Sensors (삽입된 광섬유 브래그 격자 센서를 이용한 필라멘트 와인딩된 복합재료 압력탱크의 내부 변형률 모니터링)

  • Kim, C.U.;Park, S.W.;Park, S.O.;Kim, C.G.;Kang, D.H.
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.17-20
    • /
    • 2005
  • In-situ structural health monitoring of filament wound pressure tanks were conducted during water-pressurizing test using embedded fiber Bragg grating (FBG) sensors. We need to monitor inner strains during working in order to verify the health condition of pressure tanks more accurately because finite element analyses on filament wound pressure tanks usually show large differences between inner and outer strains. Fiber optic sensors, especially FBG sensors can be easily embedded into the composite structures contrary to conventional electric strain gages (ESGs). In addition, many FBG sensors can be multiplexed in single optical fiber using wavelength division multiplexing (WDM) techniques. We fabricated a standard testing and evaluation bottle (STEB) with embedded FBG sensors and performed a water-pressurizing test. In order to increase the survivability of embedded FBG sensors, we suggested a revised fabrication process for embedding FBG sensors into a filament wound pressure tank, which includes a new protecting technique of sensor heads, the grating parts. From the experimental results, it was demonstrated that FBG sensors can be successfully adapted to filament wound pressure tanks for their structural health monitoring by embedding.

  • PDF