• Title/Summary/Keyword: femoral fracture

Search Result 148, Processing Time 0.031 seconds

Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry (대퇴골 경부 골절 환자에서 골다공증 평가를 위한 다중검출 CT의 이용: 이중에너지 X-선 흡수계측법과의 비교)

  • Hyo Jeong Lee;Ji Young Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.173-181
    • /
    • 2021
  • Purpose To evaluate the ability of the Hounsfield unit (HU) measurement of the femoral neck during multidetector computed tomography (MDCT) for assessing osteoporosis compared with dual-energy X-ray absorptiometry (DXA). Materials and Methods Forty-two patients with femoral neck fractures who underwent MDCT and DXA from July to December 2016 were included in this study. HU measurements were made of the cancellous portions of the normal contralateral femoral neck on MDCT. Bone mineral density (BMD) and T-scores were obtained at the femur DXA. Correlations of HU values with BMD and T-scores were analyzed using Spearman's correlation test. Results The mean BMD and T-score of the femoral neck were 0.650 g/cm2 and -2.4, respectively. The mean HU values for the normal, osteopenia, and osteoporosis groups were 131.9, 98.9, and 41.3, respectively. HU values at the femoral neck were positively correlated with BMD (r2 = 0.670; p < 0.001) and T-scores (r2 = 0.676; p < 0.001). Conclusion The HU values of the femoral neck on MDCT are significantly correlated with BMD and T-scores of femur DXA. The HU values may serve as a diagnostic tool for the screening of regional bone quality when MDCT is performed for other reasons.

Correlations of Lumbar and Femoral Bone Mineral Densities with Calcaneal Speed of Sound in Osteoporotic Woman (골다공증 여성에서 요추골 밑 대퇴골 부위의 골밀도와 종골 음속 사이의 상관관계)

  • Lee, Kang-Il;Choi, Min-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.6
    • /
    • pp.542-547
    • /
    • 2009
  • In this in vivo study, correlations of lumbar and femoral bone mineral densities (BMDs) with calcaneal speed of sound (SOS) were investigated in 36 osteoporotic women. Areal BMDs of the L2-L4 lumbar spine and the right femoral neck were measured by using dual energy X-ray absorptiometry (DEXA). SOS of the right calcaneus was measured by using ultrasound bone densitometry. Pearson's correlation coefficient (r) and level of significance (p) were used to evaluate the correlations between measurements. Lumbar BMD was highly correlated with femoral BMD (r=0.81). Lumbar and femoral BMDs exhibited similar comparable negative correlations with age (r=-0.52 and r=-0.55). A moderate negative correlation was found between calcaneal SOS and age (r=-0.45). Calcaneal SOS was significantly correlated with lumbar and femoral BMDs, with a higher correlation with femoral BMD rather than with lumbar BMD (r=0.54 and r=0.62). However, calcaneal SOS may not be an optimum index for the estimation of BMD of the most important fracture sites, such as the lumbar and the femur, because it showed lower correlations with lumbar and femoral BMDs compared to that with calcaneal BMD. Therefore, the development of a quantitative ultrasound technology for the direct measurement of acoustic properties at the lumbar and the femur is required to estimate BMD of these sites more accurately.

Influence of Impact Angle on Deformation in Proximal Femur during Slide Falling (측방 낙상시의 충격 각도가 대퇴골 근위부의 변형에 미치는 영향)

  • 김병수;배태수;김정규;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.233-239
    • /
    • 2003
  • Falling related injuries are categorized as the most serious and common medical problems experienced by the elderly, hip joint fracture, one of the most serious consequences of falling in the elderly, occurs in only about 1% of falling. Nevertheless, hip fracture accounts for a considerable part of the disability, death, and medical costs associated with falling. In this study, we considered the impact angle and displacement rate in falling as another factor affecting femoral strength. Using a fresh-frozen human femur, we developed system to simulate the falling condition and then conducted the experiments changing the impact angle (0$^{\circ}$, 15$^{\circ}$, 30$^{\circ}$) of proximal femur. Also, in order to analyze the relative risk due to falling to normal situation in proximal femur, we did the static test simulating the two-legged stance condition. The results showed that the change in impact angle affected the strain distribution in proximal femur, and that a large deformation in femoral neck than in other sites. Furthermore despite low impact velocity, a large deformation in proximal femur occurred in the impact test and different strain distribution was observed compare to the static case.

Improvement of Low Bone Mineral Density Treated with Jeopgol-tang in a Middle-Aged Man: A Case Report (중년 남성에서 접골탕 투여 후 개선된 골밀도에 관한 증례 보고)

  • Won, Jiyoon;Choi, Youngjin;Lee, Byung-Cheol;Lee, Hyangsook
    • The Journal of Korean Medicine
    • /
    • v.42 no.2
    • /
    • pp.90-97
    • /
    • 2021
  • Bone mineral density (BMD) is a major diagnostic marker for bone health. A 44-year-old male had BMD of 0.81 g/cm2 (Z-score: -3.1) in lumbar spine scan and 0.54 g/cm2 (Z-score: -2.7) for femoral neck from regular medical checkup in Apr 2020. He had no other specific medical conditions except hyperlipidemia and alcohol was a single risk factor for fracture according to Fracture Risk Assessment Tool. After he was diagnosed with liver-kidney deficiency and treated for 20 weeks with Jeopgol-tang originally patented for promoting fracture recovery, lumbar spine BMD increased by 13.6 % (0.92 g/cm2, Z-score: -2.1) and femoral neck BMD by 22.2% (0.66 g/cm2, Z-score: -1.8) compared with those of Mar 2020. Herbal medicine treatment for tonifying liver and kidney to improve BMD warrants further investigation.

Risk Factors Associated with Fixation Failure in Intertrochanteric Fracture Treated with Cephalomedullary Nail

  • Hyung-Gon Ryu;Dae Won Shin;Beom Su Han;Sang-Min Kim
    • Hip & pelvis
    • /
    • v.35 no.3
    • /
    • pp.193-199
    • /
    • 2023
  • Purpose: Cephalomedullary (CM) nailing is widely performed in treatment of elderly patients with femoral intertrochanteric fractures. However, in cases of fixation failure, re-operation is usually necessary, thus determining factors that may contribute to fixation failure is important. In this study, we examined factors affecting the occurrence of fixation failure, such as age or fracture stability, after CM nailing in elderly patients. Materials and Methods: This study was conducted retrospectively using registered data. From April 2011 to December 2018, CM nailing was performed in 378 cases diagnosed with femoral intertrochanteric fractures, and 201 cases were finally registered. Cases involving patients who were bed-ridden before injury, who died from causes unrelated to surgery, and those with a follow-up period less than six months were excluded. Results: Fixation failure occurred in eight cases. Comparison of the surgical success and fixation failure group showed that the mean age was significantly higher in the fixation failure group compared with the control group (81.3±6.4 vs. 86.4±6.8; P=0.034). A significantly high proportion of unstable fractures was also observed (139/54 vs. 3/5; P=0.040), with a significantly high ratio of intramedullary reduction (176/17 vs. 5/3; P=0.034). A significantly higher ratio of unstable fractures compared with that of stable fractures was observed in the intramedullary reduction group (132/49 vs. 10/10; P=0.033). Conclusion: Fixation failure of CM nailing is likely to occur in patients who are elderly or have unstable fracture patterns. Thus, care should be taken in order to avoid intramedullary reduction.

Biomechanical Finite Element Analysis of Bone Cemented Hip Crack Initiation According to Stem Design

  • Kim, Byeong-Soo;Moon, Byung-Young;Park, Jung-Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2168-2177
    • /
    • 2006
  • The purpose of this investigation was to determine the specific fracture mechanics response of cracks that initiate at the stem-cement interface and propagate into the cement mantle. Two-dimensional finite element models of idealized stem-cement-bone cross-sections from the proximal femur were developed for this study. Two general stem types were considered; Rectangular shape and Charnley type stem designs. The FE results showed that the highest principal stress in the cement mantle for each case occurred in the upper left and lower right regions adjacent to the stem-cement interface. There was also a general decrease in maximum tensile stress with increasing cement mantle thickness for both Rectangular and Charnley-type stem designs. The cement thickness is found to be one of the important fatigue failure parameters which affect the longevity of cemented femoral components, in which the thinner cement was significantly associated with early mechanical failure for shot-time period.

Duromedics Mitral Valve Leaflet Escape (Duromedics 승모판막의 판엽파손)

  • 나찬영
    • Journal of Chest Surgery
    • /
    • v.25 no.7
    • /
    • pp.750-755
    • /
    • 1992
  • We report a case of leaflet embolization of central leaflet fracture a 31mm mitral Edw-ards-Duromedics prosthesis. A leaflet was fractured to two segments, a larger one embolized to right common iliac artery and a smaller one to left femoral artery, respectively. Patient was reoperated with 29mm mitral Carbomedics prosthesis and incidentally found of smaller segment in left femoral artery at cannulation site. The embolectomy was done 15 days after cardiac operation through midline abdominal incision, Leaflet escape of a mitral Edward-Duromedics prosthesis is a rare, potentially curable mode of valve failure. After mechanical valve replacement, unexplained heart failure and acute pulmonary edema, mechanical valve failure should be suspected. Correct interpretation of clinical signs, symptoms and fluroscopy should allow early diagnosis of leaflet escape and prompt surgical therapy.

  • PDF

Ankle Salvage Procedure without Internal Fixation for Large Bone Defect after Failed Total Ankle Arthroplasty: A Case Report (실패한 족관절 인공관절 치환술 후 큰 골결손에서 내고정 없이 시행한 족관절 구제술: 증례 보고)

  • Park, Man-Jun;Eun, Il-Soo;Jung, Chul-Young;Ko, Young-Chul;Yoo, Chong-Il;Kim, Min-Woo;Hwang, Keum-Min
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.2
    • /
    • pp.76-79
    • /
    • 2014
  • In treatment of failure in ankle joint replacement therapy, talar avascular necrosis with massive bone defect, talus fracture with severe comminution and bone defect and ankle dislocation, treatment of large bone defects is considerably important for ankle joint stability and union, therefore, the choice of treatment for large bone defects is use of femoral head or iliac crest bone graft and rigid internal fixation. Because first generation total ankle arthroplasty performed for the first time using a cemented fixation technique requires a large amount of bone resection during re-surgery and there is some possibility of a larger bone defect after removal of implants, in cases where prosthesis for the defect is needed, performance of palliative femoral head or iliac crest bone graft and rigid internal fixation can be difficult. We report on a case of a 48-year-old woman who had experienced ankle pain for 25 years since undergoing total ankle arthroplasty. Because the patient had little ankle motion and rigid soft tissue despite a large bone defect caused by aseptic loosening, a good outcome was obtained only for the femoral cancellous bone graft using allo femoral head without internal fixation.

Common Iliac Artery Injury due to Blunt Abdominal Trauma without a Pelvic Bone Fracture (복부 둔상 환자에서 골반 골절을 동반하지 않고 발생한 총장골동맥 손상 증례)

  • Jung, Pil Young;Byun, Chun Sung;Oh, Joong Hwan;Bae, Keum Seok
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.215-218
    • /
    • 2014
  • Blunt abdominal trauma may often cause multiple vascular injuries. However, common iliac artery injuries without associated bony injury are very rarely seen in trauma patients. In the present case, a 77-year-old male patient who had no medical history was admitted via the emergency room with blunt abdominal trauma caused by a forklift. At admission, the patient was in shock and had abdominal distension. On abdomino-pelvic computed tomography (CT), the patient was seen to have hemoperitoneum, right common iliac artery thrombosis and left common iliac artery rupture. During surgery, an additional injury to inferior vena cava was confirmed, and a primary repair of the inferior vena cava was successfully performed. However, the bleeding from the left common iliac artery could not be controlled, even with multiple sutures, so the left common iliac artery was ligated. Through an inguinal skin incision, the right common iliac artery thrombosis was removed with a Forgaty catheter and a femoral-to-femoral bypass graft was successfully performed. After the post-operative 13th day, on a follow-up CT angiography, the femoral-to-femoral bypass graft was seen to have good patency, but a right common iliac artery dissection was diagnosed. Thus, a right common iliac artery stent was inserted. Finally, the patient was discharged without complications.

Studies on the Comparative Analysis Between GE Prodigy and $FRAX^{TM}$ Tool in Absolute Fracture Risk Assessment Tool (골절의 절대위험도 평가방법에서 GE Prodigy와 FRAX Tool의 비교분석에 관한 고찰)

  • Lee, Hwa-Jin;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Mu-Seok;Song, Hyeon-Seok;Park, Se-Yun;Jeong, Ji-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.137-142
    • /
    • 2009
  • Purpose: World Health Organization (WHO) have suggested that an individual's 10-year absolute fracture risk is more reliable than Bone Mineral Density (BMD) measurement as the predictor of osteoporotic fracture. In 2008, Fracture Risk Assessment Tool ($FRAX^{TM}$) was developed by WHO to evaluate fracture risk of patients based on individual's clinical risk factors. The purpose of this study is to offer the comparative analysis of the existing GE prodigy and $FRAX^{TM}$ Tool in Absolute Fracture Risk Assessment Tool. Materials and Methods: 201 women ($55{\pm}3.5$ years) underwent femoral neck BMD measurement using GE Prodigy. The 10-year probability (%) of hip fracture (or a major osteoporosis-related fracture) was estimated using T-scores of GE prodigy and $FRAX^{TM}$. We made a comparative analysis of these data using SPSS (Ver.12). Results: There was a significant difference statistically between T-score ($-0.52{\pm}0.97$) of GE prodigy and T-score ($-1.45{\pm}0.81$) of $FRAX^{TM}$ (r=0.977, p=0.000). Also, there was a significant difference statistically between a major osteoporosis- related fracture ($9.15{\pm}3.71$) of GE prodigy and a major osteoporosis-related fracture ($4.87{\pm}1.51$) of $FRAX^{TM}$ (r=0.909, p=0.000). Moreover, a statistically significant difference was found in the 10-year probability of hip fracture of GE prodigy ($1.56{\pm}1.48$) and of hip fracture ($0.53{\pm}0.61$) of $FRAX^{TM}$ (r=0.905, p=0.000). Conclusions: There was a significant difference statistically between GE prodigy and $FRAX^{TM}$ Tool in Absolute Fracture Risk Assessment Tool. Especially, T-score, a major osteoporosis-related fracture and the 10-year probability of hip fracture that were estimated using GE prodigy tended to show the higher results than one evaluated by $FRAX^{TM}$ Tool. In conclusion, $FRAX^{TM}$ Tool may provide a better tool. The application of $FRAX^{TM}$ Tool as a fracture predictor remains to be clarified.

  • PDF