• Title/Summary/Keyword: feedforward loop control

Search Result 100, Processing Time 0.028 seconds

Improvement of Transient Performance of Synchronous Generator using Feedforward Controller (피드포워드 제어기를 사용한 동기발전기의 과도특성 개선)

  • An, Young-Joo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.2
    • /
    • pp.57-62
    • /
    • 2018
  • A brush-less type synchronous generator driven by an internal-combustion engine is used for emergency electric source. These types of generators have to maintain a certain range of output voltage even under the sudden load change conditions such as full load application and removal. This paper describes a method for suppressing the output voltage of a synchronous generator that operates excessively when the load fluctuates. The method used in this paper is a feedforward control method in which the main voltage control consists of a feedback loop using a typical PID controller and the load current is detected as a disturbance element and compensated directly. A feedforward system is constructed in which the load current is regarded as disturbance, and the appropriate feedforward controller configuration and parameters are found through simulation. Finally, it can be seen through the experiment that the feedforward control is performed properly. It can be seen that the generator terminal voltage is recovered to the steady state in a short period of time as compared with the existing PID control method even when the entire load of the generator is changed.

Runout Control of a Magnetically Suspended High Speed Spindle Using Adaptive Feedforward Method

  • Ro Seung-Kook;Kyung Jin-Ho;Park Jong-Kwon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.2
    • /
    • pp.19-25
    • /
    • 2005
  • In this paper, the feedforward control with least mean square (LMS) adaptive algorithm is proposed and examined to reduce rotating error by runout of an active magnetic bearing system. Using eddy-current type gap sensors for control, the electrical runout caused by non-uniform material properties of sensor target produces rotational error amplified in feedback control loop, so this runout should be eliminated to increase rotating accuracy. The adaptive feedforward controller is designed and examined its tracking performances and stability numerically with established frequency response function. The designed feedforward controller was applied to a grinding spindle system which is manufactured with a 5.5 kW internal motor and 5-axis active magnetic bearing system including 5 eddy current gap sensors which have approximately 15∼30㎛ of electrical runout. According to the experimental results, the error signal in radial bearings is reduced to less than 5 ,Urn when it is rotating up to 50,000 rpm due to applying the feedforward control for first order harmonic frequency, and corresponding vibration of the spindle is also removed.

Fuzzy Control with Feedforward Compensator of Superheat in a Variable Speed Refrigeration System

  • Hua, Li;Lee, Dong-Woo;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.252-262
    • /
    • 2007
  • In this paper, we suggest fuzzy control with feedforward compensator of superheat to progress both energy saving and coefficient of performance(COP) in a variable speed refrigeration system. The capacity and superheat are controlled simultaneously and independently by an inverter and an electronic expansion valve respectively for saving energy and improving COP in the system. By adopting the fuzzy control. the controller design for the capacity and superheat is possible without depending on a dynamic model of the system. Moreover, the feedforward compensator of the superheat can eliminate influence of the interfering loop between capacity and superheat. Some experiments are conducted to design the appropriate fuzzy controller by an iteration manner. The results show that the proposed fuzzy controller with the compensator can establish good control performances for the complicated refrigeration system with inherent strong non-linearity.

Adaptive Control Method for a Feedforward Amplifier (피드포워드 증폭기의 적응형 제어 방법)

  • Kang, Sang-Gee;Yi, Hui-Min;Hong, Sung-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.2
    • /
    • pp.127-133
    • /
    • 2004
  • A feedforward amplifier, which is composed of several components, is an open loop system. Therefore, feedforward amplifiers are apt to deteriorate its performance according to the environmental changes even though the cancellation performance and the linearization bandwidth of feedforward systems are superior to other linearization methods. A control method is needed for maintaining the original performance of feedforward amplifiers or to keep the desired performance within a little error bounds. In this paper, an adaptive control method using the steepest descent algorithm, which has a good convergence characteristic and is easy to implement, is suggested. The characteristics of the suggested control method compare with the characteristics of other control methods and the simulation results are presented.

A Hybrid Control Development to Suppress the Noise in the Rectangular Enclosure using an Active/Passive Smart Foam Actuator

  • Kim Yeung-Shik;Kim Gi-Man;Roh Cheal-Ha;Fuller C. R.
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.4
    • /
    • pp.37-43
    • /
    • 2005
  • This paper presents a hybrid control algorithm for the active noise control in the rectangular enclosure using an active/passive foam actuator. The hybrid control composes of the adaptive feedforward with feedback loop in which the adaptive feedforward control uses the well-known filtered-x LMS(least mean square) algorithm and the feedback loop consists of the sliding mode controller and observer. The hybrid control has its robustness for both transient and persistent external disturbances and increases the convergence speed due to the reduced variance of the jiltered-x signal by adding the feedback loop. The sliding mode control (SMC) is used to incorporate insensitivity to parameter variations and rejection of disturbances and the observer is used to get the state information in the controller deign. An active/passive smart foam actuator is used to minimize noise actively using an embedded PVDF film driven by an electrical input and passively using an absorption-foam. The error path dynamics is experimentally identified in the form of the auto-regressive and moving-average using the frequency domain identification technique. Experimental results demonstrate the effectiveness of the hybrid control and the feasibility of the smart foam actuator.

Active Noise Transmission Control Through a Panel Structure Using a Frequency Domain Identification Method (주파수 영역 모델 방법을 이용한 평판 구조물의 능동 소음전달 제어)

  • Kim, Yeung-Shik;Kim, In-Soo;Moon, Chan-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.9
    • /
    • pp.71-81
    • /
    • 2001
  • This paper analyzes the effectiveness of minimizing vibration and sound transmission on/through a thin rectangular plate by both feedback control and hybrid control which combines adaptive feedforward control with a feedback loop. An experimental system identification technique using the matrix-fractional curve-fitting of the frequency response data is introduced for complex shaped structures. This identification technique reduces the model order o the MIMO(Multi-Input Multi-Output) system which simplifies the practical implementation. The adaptive feedforward control uses a Multiple filtered-x LMS(Least Mean Square) algorithm and the feedback control uses a multivariable digital LQG(Linear Quadratic Gaussian) algorithm. Experimental results show that an effective reduction of sound transmission is achieved by the hybrid control scheme when both vibration and noise measurement signals are incorporated in the controller.

  • PDF

Design and Analysis of Fuzzy Control in a Variable Speed Refrigeration System

  • Hua, Li;Jeong, Seok-Kwon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.2
    • /
    • pp.61-69
    • /
    • 2007
  • This paper deals with fuzzy control with a feedforward compensator to progress both energy saving and coefficient of performance (COP) in a variable speed refrigeration system. Both the capacity and superheat are controlled simultaneously and independently in the system. By adopting the fuzzy theory, the controller design for the capacity and superheat is possible without depending on a dynamic model of the system. Moreover, the feedforward compensator of the superheat can reduce influence of the interfering loop between the capacity and superheat. Some experiments are conducted to design appropriate fuzzy controller by an iteration manner. The results show that the proposed fuzzy controller with the compensator can establish good control performances for the complicated refrigeration system in spite of its inherent strong non-linearity. Also, the fuzzy control performances were investigated by comparing to the model based PI control experimental results to evaluate transient behavior under the control.

Two-degree-of-freedom control for descriptor system with disturbance

  • Yeu, Tae-Kyeong;Kawaji, Shigeyasu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.151.2-151
    • /
    • 2001
  • In this paper, the design of a two-degree-of-freedom(TDF) controller is proposed to track the reference model, as well as to reject an influence of measurable disturbance for descrpitor system. The TDF controllers based on the Youla parametrization reveals that the design of the feedforward controller and the regulator can be done independently. First, to solve this problem, we will change descriptor system into regular state space system using a state feedback. And then, the feedforward controller is determined by solving a full information approach for augmented system with a nominal control constraint, and the regulator is designed by means of the loop-Shaping method.

  • PDF

Force control of a structurally flexible robotic manipulator

  • 최병오
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.369-373
    • /
    • 1992
  • Force control of a planar two-link structurally flexible robotic manipulator is considered in this study. The dynamic model is obtained by using the extended Hamilton's principle and the Galerkin criterion. A method is pressented toobtain the linearized equations of motion in Cartesian space for use in designing the control system. The approachto solving the control problem is to use feedforward and feedback control torques. The feedforward torques maneuver the flexible manipulatro along a nominal trajectory and the feedback torques minimize any deviations from the nominal trajectory. The linear quadratic Gaussian/loop transfer recovery (LQG/LTR) design methodology is explotied to design a robust feedback control system that can handle modeling errors and sensor noise, and operates on Cartesian space trajectory errors. The Lqg/LTR compenstaor together with a feedforward ollp is used to control the flexible manipulator. Simulated results are presented for a numerical example.

PERIODIC DISTURBANCE AND NOISE REJECTION METHOD USING HIRBERT TRANSFORM (힐버트 변환을 이용한 주기적인 외란 및 잡음제거)

  • Na, Hee-Seung;Park, Young-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.443-448
    • /
    • 2000
  • In this paper, we propose a novel adaptive feedforward controller for periodic disturbance and noise cancellation, with a frequency tracking capability. It can be added to an existing feedback control system without altering the original closed-loop characteristics, which is based on adaptive algorithm. We introduce novel algorithm "Constrained AFC(adaptive feedforward controller) algorithm" that increase the convergence region regardless of the delay in the closed loop system. In the algorithms, coefficients of the controller are adapted using the residuals of constrained structure which are defined in such a way that the coefficients become time invariant. The proposed algorithm not only estimate the magnitude and phase of the tonal disturbance and noise but also track the frequency of the tone, which changes in quasi-static manner. The frequency tracking algorithm uses the instantaneous frequency approach based on Hilbert transform. A number of computer simulations have been carried out in order to demonstrate the effectiveness of proposed method under various conditions.

  • PDF