• Title/Summary/Keyword: feasibility Test

Search Result 1,653, Processing Time 0.023 seconds

Feasibility Study on Cold Water Pipe Diameter by Friction Loss and Energy Conversion on OTEC (해양온도차 발전을 위한 심층수 파이프 직경에 따른 에너지 손실량 검토)

  • Jung, Hoon;Heo, Gyunyoung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.170-170
    • /
    • 2010
  • The energy conversion from the temperature difference between hot and cold source like ocean thermal energy conversion (OTEC), requires a long and large-diameter pipe (about 1000 to 10,000 meters long) to reach the deep water. The pipe diameter ranges from 2.8 meter for proposed early test systems, to 5 meter for large, commercial power generation systems. The pipe must be designed to resist collapsing pressures produced by water temperature and density differences, and the reduced pressure required to induce flow up the pipe. Other design considerations include the external-drag effect on the pipe due to ocean currents, and the wave-induced motions of the platform to which the pipe is attached. Various approaches to the pipe construction have been proposed, including aluminum, steel, concrete, and fiberglass. More recently, a flexible pipe construction involving the use of fiberglass reinforced plastic has been proposed. This report presents the results of a scaled fixed cold water pipe (CWP) model test program performed by EES(Engineering Equation Solver) to demonstrate the feasibility of this pipe approach.

  • PDF

A Systematic Approach to Accident Scenario Analysis: Child Safety Seat Case Study (체계적 사고 시나리오 분석기법을 이용한 유아용 안전의자 사례연구)

  • Byun, Seong-Nam;Lee, Dong-Hoon
    • IE interfaces
    • /
    • v.15 no.2
    • /
    • pp.114-125
    • /
    • 2002
  • The objective of this paper is to describe a systematic accident scenario analysis method(SASA) adept at creating accident scenarios for the design of safer products. This approach was inspired by the Quality Function Deployment(QFD) method, which is conventionally used in quality management. In this study, the QFD provides a formal and systematic scheme to devise accident scenarios while maintaining objectivity. SASA consists of three key stages to be broken down into a series of consecutive steps:(1) developing an accident analysis tableau,(2) devising the accident scenarios using the accident analysis tableau,(3) performing a feasibility test, a clustering process and a patterning process, and finally(4) performing quantitative evaluation of each accident scenario. The SASA was applied to a case study of child safety seats. The accident analysis tableau devised 2828(maximum) accident scenarios from all possible relationships between the hazard factors and situation characteristics. Among them, 270 scenarios were devised through the feasibility test and the clustering process. The patterning process reduced them to 29 patterns representative of all accident scenarios. Based on an intensive analysis of the accident patterns, design guidelines for a safer child safety seat were recommended. The implications of the study on the child safety seat case were then discussed.

Measuring health activation among foreign students in South Korea: initial evaluation of the feasibility, dimensionality, and reliability of the Consumer Health Activation Index (CHAI)

  • Park, MJ;Jung, Hun Sik
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.192-197
    • /
    • 2020
  • Foreign students in South Korea face important challenges when they try to maintain their health. As a measure of their motivation to actively build skills for overcoming those challenges, we evaluated the 10-item Consumer Health Activation Index (CHAI), testing its feasibility, dimensionality, and reliability. There were no missing data, there was no floor effect, and for the total scores the ceiling effect was trivial (< 2%). Results of the Kaiser-Meyer-Olkin test and Bartlett's test of sphericity indicated that the data were suitable for the detection of structure by factor analysis. The results of parallel analysis and the shape of the scree plot supported a two-factor solution. One factor had 3 items concerning "my doctor" and the other factor had the 7 remaining items. Reliability was high for the 10-item CHAI (alpha = 0.856), for the 3-item subscale (alpha = 0.838), and for the 7-item subscale (alpha = 0.857). Reliability could not be improved by deletion of any items. Use of the CHAI to gather data from these foreign students is feasible, and reliable results can be obtained whether one uses the total score from all 10 items or scores from the proposed 7-item and 3-item subscales.

Multiple-Case Studies of Hand-on Breast Massage Techniques used by Breastfeeding Experts (산후 유방 마사지 손기술에 대한 다중사례분석)

  • Park, Hyunsoon;Cho, Insook;Kim, Min-Kyeong
    • Women's Health Nursing
    • /
    • v.23 no.3
    • /
    • pp.155-165
    • /
    • 2017
  • Purpose: The aim of this study was to understand the hand-on breast massage techniques used by well-known experts in breastfeeding clinics. Methods: A qualitative multiple-case design was applied that involved a feasibility test. Four experts sampling qualitative data collected by observing participants and in individual interviews were analyzed by content analysis, linking data to the propositions, and cross-case pattern matching. This study explored differences within and between cases, and the possibilities of replicating findings across cases. Thirty-nine postpartum women participated voluntarily in the feasibility test, which investigated the usability of four massage techniques. Results: The four techniques showed considerable similarities in terms of the application of stimulation to the breast base and increased flexibility of the wired flexible body, which was the core mechanism underlying the techniques. The breast management strategies were consistent with existing practice guidelines with the exception of using cold cabbage to control engorgement pain. There was insufficient scientific evidence for supporting the massage techniques used by the experts. All of the techniques showed 100% education completeness, but application rates were higher for self-control-oriented techniques. Conclusion: The massage techniques applied by experts in breastfeeding were based on hypotheses and self-control techniques are feasible to apply in practice.

The Performance Test and the Feasibility Study for a Dual-Source Heat Pump System Using the Air and Ground Heat Source (공기 및 지열 이용 Dual-Source 히트펌프 시스템의 성능실험 및 경제성 분석)

  • Nam, Yujin;Chae, Ho-Byung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.212-217
    • /
    • 2014
  • Recently, the use of renewable energy has been increased due to growing concern on the energy-saving at buildings and the reduction of $CO_2$ emission. In the field of architecture, to reduce the energy consumption of heating, cooling and hot water supply, heat pump systems with renewable energy has been developed and used in various applications. However, there have been many of researches on the large-scale commercial heat pump systems, but the research and the field application of a compact heat pump system is rare. Therefore, in order to develop the compact heat pump for the small-scale residential building, this study conducted the performance test and feasibility study for a hybrid heat pump using the heat source of air, solar and ground. In the results of experiments through a trial product, the average COP of cooling mode with ground heat source was 4.75, and it of heating mode was 4.03. Furthermore, the average COP of cooling mode with air heat source was 2.60, and it of heating mode was 2.92. Finally, payback period of the system was calculated as 9.2 years.

Evaluation of Feasibility of PDA-based Traffic Accident Investigation Device (PDA기반 교통사고 조사 장치의 적용성 평가)

  • Lee, Eun-Jung;Lee, Sang-Soo;Oh, Young-Tae;Lee, Choul-Ki
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.3
    • /
    • pp.34-41
    • /
    • 2009
  • Recently, information-Ievel of the people has been increased with growing IT cutting-edge technology. There is a trend to combine these achievements with information-technology, ubiquitous technology, and mobile technology in the field of transportation. Along with this trend, a PDA-based traffic accident investigation device was developed. This paper established the evaluation method of feasibility test on the PDA device, and performed qualitative and quantitative evaluation as compared with the current practice (manual investigation). Test results showed that traffic accident investigation using the PDA device was faster and more convenient than manual investigation. It is expected that the reliability of accident investigation will be improved by applying this tool with minor modifications.

  • PDF

Development and Application of a Nursing Assessment Tool for Senior Center Nurses (노인복지관 간호사를 위한 간호사정조사도구 개발 및 적용)

  • Ko, Ha Na;Song, Misoon
    • Perspectives in Nursing Science
    • /
    • v.13 no.2
    • /
    • pp.96-109
    • /
    • 2016
  • Purpose: The purposes of this study were to develop a nursing assessment tool for senior center nurses, and to test its feasibility and content validity. Methods: The study utilized a psychometric test design. Preliminary items were developed based on geriatric health needs and Gordon's 11 domains of functioning health. Initially, the tool was evaluated for content validity and feasibility. Then, it was administered among 195 older adults in a senior center by a gerontological nurse practitioner. Data were analyzed to describe the nursing problems of the senior center older adults. Results: The final version of the nursing assessment tool consisted of 27 items. The internal consistency, measured with the Cronbach's ${\alpha}$, was .74. The result of the assessment showed that senior center older adults had high nursing needs in the area of management of chronic diseases (hypertension, diabetes, and lipids), dental care, community relations, safety, elder abuse, health behaviors (such as drinking), mental health (depression, suicide, and cognitive function), and health consultations. Conclusion: The new tool was feasible for use with senior center participants, and it was evaluated as having high content validity by senior center nurses.

A Design of Dangerous Sound Detection Engine of Wearable Device for Hearing Impaired Persons (청각장애인을 위한 웨어러블 기기의 위험소리 검출 엔진 설계)

  • Byun, Sung-Woo;Lee, Soek-Pil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1263-1269
    • /
    • 2016
  • Hearing impaired persons are exposed to the danger since they can't be aware of many dangerous situations like fire alarms, car hones and so on. Therefore they need haptic or visual informations when they meet dangerous situations. In this paper, we design a dangerous sound detection engine for hearing impaired. We consider four dangerous indoor situations such as a boiled sound of kettle, a fire alarm, a door bell and a phone ringing. For outdoor, two dangerous situations such as a car horn and a siren of emergency vehicle are considered. For a test, 6 data sets are collected from those six situations. we extract LPC, LPCC and MFCC as feature vectors from the collected data and compare the vectors for feasibility. Finally we design a matching engine using an artificial neural network and perform classification tests. We perform classification tests for 3 times considering the use outdoors and indoors. The test result shows the feasibility for the dangerous sound detection.

Transiting test method for galloping of iced conductor using wind generated by a moving vehicle

  • Guo, Pan;Wang, Dongwei;Li, Shengli;Liu, Lulu;Wang, Xidong
    • Wind and Structures
    • /
    • v.28 no.3
    • /
    • pp.155-170
    • /
    • 2019
  • This paper presents a novel test method for the galloping of iced conductor using wind generated by a moving vehicle which can produce relative wind field. The theoretical formula of transiting test is developed based on theoretical derivation and field test. The test devices of transiting test method for aerodynamic coefficient and galloping of an iced conductor are designed and assembled, respectively. The test method is then used to measure the aerodynamic coefficient and galloping of iced conductor which has been performed in the relevant literatures. Experimental results reveal that the theoretical formula of transiting test method for aerodynamic coefficient of iced conductor is accurate. Moreover, the driving wind speed measured by Pitot tube pressure sensors, as well as the lift and drag forces measured by dynamometer in the transiting test are stable and accurate. Vehicle vibration slightly influences the aerodynamic coefficients of the transiting test during driving in ideal conditions. Results of transiting test show that the tendencies of the aerodynamic coefficient curve are generally consistent with those of the wind tunnel tests in related studies. Meanwhile, the galloping is fairly consistent with that obtained through the wind tunnel test in the related literature. These studies validate the feasibility and effectiveness of the transiting test method. The present study on the transiting test method provides a novel testing method for research on the wind-resistance of iced conductor.

An Experimental Study on Piping Feasibility of PE Compound Pipe for Fire Protection Service (PE 이종강관의 소방용 배관 적용성에 관한 실험적 연구)

  • Park, Jeong-Hwa;Oh, Cheon-Young;Kwark, Ji-Heon;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.55-61
    • /
    • 2016
  • In this study, to determine whether it is possible to apply Polyethylene (PE) compound pipe, which was developed to solve the problem caused by the corrosion of the fire protection piping currently in usein water based fire extinguishing systems, we performed an actual mockup fire test. Since no test standard was available related to the developed compound pipe, we compared and analyzed domestic and international technical materials and test standards and selected suitable fire test standards to evaluate the performance of the PE compound pipe. we applied two fire test standards to the PE compound pipe, viz. those for CPVC and metallic pipes, and conducted a total of 6 experiments to evaluate its performance. According to the results of the first and second fire tests based on the test standard for the CPVC pipe, neither the fitting nor the piping was damaged or deformed and no leakage was observed in the pressure test, which was performed for 5 minutes. For the fire test based on the metallic pipe test standard, a total of 4 experiments were conducted. The first two experiments were conducted to simulate the wet piping system. In the results of this fire test, neither leakage nor rupture was observed from the PE compound pipe and no damage was caused, such as the secession of the PE material. However, in the next two experiments, which simulated the dry system, the PE compound pipe suffered damage and rupture, including deformation before the fire fighting water was discharged. Therefore, we found that the piping performance of the PE compound pipe did not undergo any deterioration, including fusion, deformation, or damage, in the wet piping system simulated fire test.