• Title/Summary/Keyword: fault structure

Search Result 682, Processing Time 0.033 seconds

A Study on System's Reliability Evaluation Using DFT Algorithm (동적 결함 트리 (Dynamic Fault Tree) 알고리즘을 이용한 시스템의 신뢰도 평가에 관한 연구)

  • 김진수;양성현;이기서
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.280-287
    • /
    • 1998
  • In this paper, Dynamic Fault Tree algorithm(DFT algorithm) is presented. This new algorithm provides a concise representation of dynamic fault tolerance system structure with redundancy, dynamic redundancy management and complex fault & error recovery techniques. And it allows the modeler to define a dynamic fault tree model with the relative advantages of both fault tree and Markov models that captures the system structure and dynamic behavior. This algorithm applies to TMR and Dual-Duplex systems with the dynamic behavior and show that this algorithm captured the dynamic behavior in these systems with fault & error recovery technique, sequence-dependent failures and the use dynamic spare. The DFT algorithm for solving the problems of the systems is more effective than the Markov and Fault tree analysis model.

  • PDF

A Study on the Structure of the Yangsan Fault In the southern part of Kyeongju (경주 남부지역의 양산단층의 구조에 관한 연구)

  • Kim, Yeonghwa;Lee, Kiehwa
    • Economic and Environmental Geology
    • /
    • v.20 no.4
    • /
    • pp.247-260
    • /
    • 1987
  • As a part of study on the structure of the Yangsan Fault, geological and VLF EM studies have been made in the fault area approximately between Kyeongju and Eonyang. The result provides comparatively clear information on the trace of the fault and extent of fracture zone as well as the structural characteristics of the Yangsan Fault area. The location of fault trace identified from this VLF EM study coincides well in general with that expected from geological information of the area. And the extent of fault fracture zone turn out to be characterized by U shaped low resistivity zone whose width increases from north to south.

  • PDF

Characteristics of the magnetic flux-offset type FCL by switching component

  • Jung, Byung-Ik;Choi, Hyo-Sang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.2
    • /
    • pp.18-20
    • /
    • 2016
  • The study of superconducting fault current limiter (SFCL) is continuously being studied as a countermeasure for reducing fault-current in the power system. When the fault occurred in the power system, the fault-current was limited by the generated impedance of SFCLs. The operational characteristics of the flux-offset type SFCL according to turn ratios between the primary and the secondary winding of a reactor were compared in this study. We connected the secondary core to a superconductor and a SCR switch in series in the suggested structure. The fault current in the primary and the secondary winding of the reactor and the voltage of the superconductor on the secondary were measured and compared. The results showed that the fault current in the load line was the lowest and the voltage applied at both ends of the superconductor was also low when the secondary winding of the reactor had lower turn ratio than the primary. It was confirmed based on these results that the turn ratio of the secondary winding of the reactor must be designed to be lower than that of the primary winding to reduce the burden of the superconductor and to lower the fault current. Also, the suggested structure could increase the duration of the limited current by limiting the continuous current after the first half cycle from the fault with the fault current limiter.

Recognition of rolling bearing fault patterns and sizes based on two-layer support vector regression machines

  • Shen, Changqing;Wang, Dong;Liu, Yongbin;Kong, Fanrang;Tse, Peter W.
    • Smart Structures and Systems
    • /
    • v.13 no.3
    • /
    • pp.453-471
    • /
    • 2014
  • The fault diagnosis of rolling element bearings has drawn considerable research attention in recent years because these fundamental elements frequently suffer failures that could result in unexpected machine breakdowns. Artificial intelligence algorithms such as artificial neural networks (ANNs) and support vector machines (SVMs) have been widely investigated to identify various faults. However, as the useful life of a bearing deteriorates, identifying early bearing faults and evaluating their sizes of development are necessary for timely maintenance actions to prevent accidents. This study proposes a new two-layer structure consisting of support vector regression machines (SVRMs) to recognize bearing fault patterns and track the fault sizes. The statistical parameters used to track the fault evolutions are first extracted to condense original vibration signals into a few compact features. The extracted features are then used to train the proposed two-layer SVRMs structure. Once these parameters of the proposed two-layer SVRMs structure are determined, the features extracted from other vibration signals can be used to predict the unknown bearing health conditions. The effectiveness of the proposed method is validated by experimental datasets collected from a test rig. The results demonstrate that the proposed method is highly accurate in differentiating between fault patterns and determining their fault severities. Further, comparisons are performed to show that the proposed method is better than some existing methods.

A Study on the Deep Structure of Yangsan Fault by Electric and Electromagnetic Surveys in Unyang and Bong-gye Areas, Kyeongnam Province, Korea (경상남도 언양 및 봉계리 지역에서의 전기, 전자탐사에 의한 양산단층의 심부구조 연구)

  • 손호웅;윤혜수;오진용
    • Economic and Environmental Geology
    • /
    • v.33 no.6
    • /
    • pp.525-536
    • /
    • 2000
  • Electromagnetic and electric surveys were performed to reveal the deep structure of the Yangsan fault in the Bong-gye and Unyang areas, Kyeongnam Province, Korea. Especially, high-frequency magnetotelluric (HFMT) method of EM survey was mainly employed to study the deep subsurface configuration of Yangsan fault. HFMT survey was performed at 25 points of spacing 50 m, making 1.3 km survey line in Unyang area and 13 points of spacing 50 m, making 0.6 km survey line in Bong-gye area. Two 2-D cross-sections (Unyang and Bong-gye areas) were achieved as results. Electric survey by dipole-dipole array was performed to study the structure of shallow subsurface and compare the results with HFMT surveys. The results of HFMT and electric surveys show that Yangsan fault is a geologic boundary. It is very narrow and steep (about $80^{\circ}C$), and extends to 1~1.5 km depth.

  • PDF

Active structural control via metaheuristic algorithms considering soil-structure interaction

  • Ulusoy, Serdar;Bekdas, Gebrail;Nigdeli, Sinan Melih
    • Structural Engineering and Mechanics
    • /
    • v.75 no.2
    • /
    • pp.175-191
    • /
    • 2020
  • In this study, multi-story structures are actively controlled using metaheuristic algorithms. The soil conditions such as dense, normal and soft soil are considered under near-fault ground motions consisting of two types of impulsive motions called directivity effect (fault normal component) and the flint step (fault parallel component). In the active tendon-controlled structure, Proportional-Integral-Derivative (PID) type controller optimized by the proposed algorithms was used to achieve a control signal and to produce a corresponding control force. As the novelty of the study, the parameters of PID controller were determined by different metaheuristic algorithms to find the best one for seismic structures. These algorithms are flower pollination algorithm (FPA), teaching learning based optimization (TLBO) and Jaya Algorithm (JA). Furthermore, since the influence of time delay on the structural responses is an important issue for active control systems, it should be considered in the optimization process and time domain analyses. The proposed method was applied for a 15-story structural model and the feasible results were found by limiting the maximum control force for the near-fault records defined in FEMA P-695. Finally, it was determined that the active control using metaheuristic algorithms optimally reduced the structural responses and can be applied for the buildings with the soil-structure interaction (SSI).

Rule-based Fault Detection Agent System for Fault Detection and Location on LAN (LAN 상의 장애 검출 및 위치 확인을 위한 규칙 기반 장애 진단 에이전트 시스템)

  • Jo, Gang-Hong;An, Seong-Jin;Jeong, Jin-Uk
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.7
    • /
    • pp.2169-2178
    • /
    • 2000
  • This paper proposes the structure of an agent and rules for fault detection and location on LAN. To find out a reason of critical fault incurred LAN, collision detection rule, error detection rule, broadcast detection rule, system location rule, and Internet application location rule ar shown. Also, the structure of multi-agent system and state transition diagram is portrayed to have connectivity with he set of rules. To verify availability of proposed rules, the process to find a faulty system is shown by monitoring and analyzing the LAN fault occurrences from the proposed set of rules. Such an rule based agent system is helpful to an Internet manager to solve a reason of fault and make ad decision from gathering management information.

  • PDF

Development of Intelligent Fault Diagnosis System for CIM (CIM 구축을 위한 지능형 고장진단 시스템 개발)

  • Bae, Yong-Hwan;Oh, Sang-Yeob
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.2
    • /
    • pp.199-205
    • /
    • 2004
  • This paper describes the fault diagnosis method to order to construct CIM in complex system with hierarchical structure similar to human body structure. Complex system is divided into unit, item and component. For diagnosing this hierarchical complex system, it is necessary to implement a special neural network. Fault diagnosis system can forecast faults in a system and decide from the signal information of current machine state. Comparing with other diagnosis system for a single fault, the developed system deals with multiple fault diagnosis, comprising hierarchical neural network (HNN). HNN consists of four level neural network, i.e. first is fault symptom classification and second fault diagnosis for item, third is symptom classification and forth fault diagnosis for component. UNIX IPC is used for implementing HNN with multitasking and message transfer between processes in SUN workstation with X-Windows (Motif). We tested HNN at four units, seven items per unit, seven components per item in a complex system. Each one neural network represents a separate process in UNIX operating system, information exchanging and cooperating between each neural network was done by message queue.

  • PDF

A Study on Characteristics and Dynamic Response Spectrum of Near Fault Ground Motions (근거리지진의 특성과 동적응답스펙트럼에 관한 연구)

  • Bang, Myung-Seok;Han, Sung-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.143-151
    • /
    • 2005
  • In this study, it is demonstrated that how the effect of the Near Fault Ground Motion affects the response of the structure. Considering the general characteristic of Near Fault Ground Motion the characteristics of Near Fault Ground Motions is analysed by elastic response spectrums, and the inelastic response spectrum is evaluated with the ductility and the yield strength to consider the inelastic behavior which couldn't be simulated through the elastic response spectrum. The result of this study shows that the effect of Near Fault Ground Motion should be considered in the long period range of long span structures but the domestic seismic design code was developed based on Far Fault Ground Motions, so the effects of Near Fault Ground Motions, which is very serious especially in large structures with a long period, are not considered. Therefore, the effect of the Near Fault Ground Motion has to be examined especially in the seismic performance evaluation of long period structure.

Electrical Resistivity Survey on the Geolgical Structure of the Bonghwajae Area in the Okchon Zone (옥천대(沃川帶)의 지질(地質) 및 광물자원(鑛物資原)에 관(關)한 연구(硏究) -봉화재 지역(地域)에 대(對)한 전기비저항탐사(電氣比抵抗探査)-)

  • Min, Kyung Duck;Kim, Chang Ryol;Yun, Chun Sung;Chung, Seung Hwan
    • Economic and Environmental Geology
    • /
    • v.21 no.2
    • /
    • pp.131-137
    • /
    • 1988
  • Geological and electrical resistivity surveys were carried out to investigate subsurface geology and geologic structure of the Bonghwajae area in the Okchon zone. Pseudosections of the apparent electrical resistivity distribution along the three survey lines were obtained by using dipole-dipole electrode array method, and models of subsurface geology and geologic structure by using two dimensional finite difference method. The Bonghwajae fault zone exists around Bonghwajae area in the north-south direction, and is a boundary between Okchon Group and Choson Supper Group. Metabasite and hornblende gabbro intruded along the Bonghwajae fault zone remaining two fracture zones with low resistivity value of 20 ohm-m and widths of about 100m and 70-300m. They strike nearly N-S and dip westward with a high angle of $60-70^{\circ}$. Sochangri fault with a width of about 160m exists between Jisogori and Bonghwajae, by which Bonghwajae fault zone is displaced about 1km in the east-west direction. Hornblende gabbro whose electrical resistivity value is in the range of 5000-8000 ohm-m intruded the metabasite of 2000-4500 ohm-m after the Sochangri fault had formed. Great Limestone Group is widely distributed in the east of Bonghwajae fault zone, and interbeds so called Yongam formation of graphitic black slate with an extremely low electrical resistivity value of 2 ohm-m.

  • PDF