• Title/Summary/Keyword: fault location

Search Result 474, Processing Time 0.028 seconds

Using Distance Relaying Algorithm Using Reflection Coefficients Estimation (반사계수 추정에 의한 초고속 거리계전 알고리즘)

  • Jung, Byung-Tae;Cho, Kyung-Rae;Hong, Jun-Hee;Jeong, Hae-Seong;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.36-38
    • /
    • 1994
  • A novel UHS relaying algorithm using reflection coefficients estimation is proposed. Based on a travelling ware approach the algorithm can determine the fault location in a travelling time of the protected lone. The discrimation of the reflected wave from others is possible observing the difference of two coefficients. The algorithm is tested using results determined by EMTP.

  • PDF

A study for the fault location of insulation defects considering waveguide characteristics in GIS (GIS의 도파관 특성을 고려한 절연결함 위치판정에 관한 연구)

  • Kim, Young-Hong;Lee, Young-Jo;Jeong, Sung-Yong;Ryu, Cheol-Hwi;Lee, Jeon-Seon;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1434-1435
    • /
    • 2007
  • UHF 센서를 사용한 GIS의 절연결함 패턴분석 및 위치판독에 대한 많은 연구가 이루어지고 있으나, 후자의 경우 GIS Bus bar의 형태에 의한 전자파의 전달속도를 고려한 결과들은 아직 보고된바 없다. 본 논문은 이러한 관점에서 부분방전 신호검출용 광대역 센서를 Fat-Dipole를 변형시켜 가장 넓은 대역을 얻도록 설계 제작하였으며, GIS Bus bar 내에서 발생하는 부분방전 신호의 전달 속도 계산결과 이론치의 약 2/3 정도였다. 또한 개발된 방법의 현장적용 가능성을 확인하기 위하여 자체 설계 제작한 외장형 UHF 센서를 중부발전소에서 운전중인 GIS에 부착하여 절연결함 위치를 추정 후 해체 작업을 통하여 확인한 결과 추정된 위치에서 결함이 발견되어 개발된 방법의 신뢰성을 입증하였다.

  • PDF

Landslide Susceptibility Analysis of Clicap, Indonesia

  • Kim, I. J.;Lee, S.;Choi, J. W.;Soedradjat, Gatot Moch
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.141-143
    • /
    • 2003
  • The aim of this study is to evaluate the susceptibility of landslides at Clicap area, Indonesia , using a Geographic Information System (GIS). Landslide locations were identified from field surveys. The topographic and geological map were collected and constructed into a spatial database using GIS. The factors that influence landslide occurrence, such as slope, aspect and curvature of topography, were calculated from the topographic database and lihology and fault was extracted from the geological database. Then landslide susceptibility was analyzed using the landslide-occurrence factors by likelihood methods. The results of the analysis were verified using the landslide location data. The GIS was used to analyze the vast amount of data efficiently . The results can be used to reduce associated hazards, and to plan land use and construction.

  • PDF

UPFC Model for Stability Study Considering the Controller Rating (UPFC 설비용량을 고려한 안정도 해석 모형)

  • Kim, H.M.;Kook, K.S.;Jeon, J.H.;Lee, Y.W.;Oh, T.K.;Jang, B.H.;Chu, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.269-272
    • /
    • 1998
  • This paper presents an UPFC(Unified Power Flow Controlled model that considered rating for stability study. The proposed UPFC model was implemented by PSS/E and IPLAN. As a control strategy for damping electromechnical oscillations, energy function method was adopted. By the adopted control law, the damping effect is robust with respect to loading condition, fault location and network structure. The effect of control of the UPFC model was demonstrated on a one machine infinite bus system.

  • PDF

A Study on Algorithm for Fault Detection and Location on LAN (LAN 장애 검출 및 위치 확인 알고리즘에 관한 연구)

  • Joe, Kyu-Oak;Ahn, Seong-Jin;Chung, Jin-Wook
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2000.04a
    • /
    • pp.324-327
    • /
    • 2000
  • 본 논문에서는 LAN 상에서의 장애 검출과 장애를 유발시킨 호스트에 대한 위치 확인을 통하여 보다 효율적인 네트워크 장애 관리가 이루어질 수 있도록 하기 위한 알고리즘을 제시하고 있다. LAN 상에서의 주된 장애로 충돌율에 의한 네트워크 지연 장애를 들 수 있다. 따라서 패킷 충돌 감지를 통하여 네트워크 지연을 감지하고 이를 통하여 브로드캐스트, 멀티캐스트, 에러 발생 패킷 등을 분석하여 충돌율을 많이 발생시킨 호스트를 찾는다. 패킷을 많이 발생시킨 호스트에 대하여 RMON2를 이용하여 응용 프로토콜의 종류를 파악하고 이에 대한 내용을 관리자에게 통보함으로써 네트워크 장애 관리를 효율적으로 수행할 수 있다.

  • PDF

A Study on Failure Diagnosis System for a Hydraulic Pump in Injection Molding Machinery Using Vibration Analysis (진동 분석을 이용한 사출성형기 유압펌프 결함 진단 시스템에 관한 연구)

  • Kim, Taehyun;Jeon, Yongho;Lee, Moon Gu
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3
    • /
    • pp.343-348
    • /
    • 2013
  • In line with the advances in factory automation, various pieces of equipment are now operated in batch processes controlled by computers. However, many kinds of faults can occur in complicated and large systems, which can result in low productivity and economic loss. The reliability and safety of systems have been studied because of the difficulty of determining the severity and location of faults. Therefore, it is necessary to detect and diagnose such faults in order to guarantee the reliability and safety of the equipment. In this paper, a diagnosis method for the ball bearings of a hydraulic pump is applied using a vibration signal for the maintenance of injection molding equipment. The bearings' defects are selected as a main failure mode through a failure mode and effect analysis (FMEA). Usually, there are nonlinear and impulse components of vibration in a ball bearing with faults. For the effective fault diagnosis of a ball bearing, nonlinear diagnostic methods and time-frequency analysis are applied, in addition to the methods currently used, such as power spectrum, time series analysis, and statistical methods. As a result of this study, a failure diagnosis system is provided that is useful even for non-experts. This is a condition-based method that makes it possible to resolve problems in a timely and economical way, in contrast to the prior method, which required regular but wasteful maintenance based on the experience of expensive external experts.

Analysis of fault current in offshore wind farm ccording to the grid connection method (해상풍력 발전단지의 전력망 연계방식에 따른 고장전류 분석)

  • Ahn, Jin-Hong;Kim, Eel-Hwan
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.691-698
    • /
    • 2020
  • The installation cost or the magnitude of the fault current varies depending on the grid connection method of the offshore wind farm. Therefore, there is a need for an efficient power grid connection method considering the capacity and location of the complex. In particular, most power cables in offshore wind farms use 3-core considering cost and efficiency. In the event of a failure such as a short circuit, the entire cable must be replaced, which can lead to significant losses in terms of cost, considering repair costs and turbine downtime. Therefore, in this paper, a radial, ring, and molding method is introduced into a 100 MW wind farm to be installed at Jeju offshore, and a three-phase short circuit failure is performed using a PSCAD/EMTDC program to perform computer analysis. I would like to propose a suitable power grid connection method.

The Implementation of Load Resistance Measurement System using Time-Frequency Domain Reflectometry (시간-주파수 영역 반사파 계측방법을 이용한 부하 저항 측정 시스템 구현)

  • Kwak, Ki-Seok;Park, Tae-Geun;Yoon, Tae-Sung;Park, Jin-Bae
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.10
    • /
    • pp.435-442
    • /
    • 2006
  • One of the most important topics about the safety of electrical and electronic system is the reliability of the wiring system. The Time-Frequency Domain Reflectometry(TFDR) is a state-of-the-art system for detecting and estimating of the fault on a wiring. In this paper, We've considered the load resistance measurement on a coaxial cable using TFDR in a way of expanded application. The TFDR system was built using commercial Pci extensions for Instrumentation(PXI) and LabVIEW. The proposed real time TFDR system consisted of the reference signal design, signal generation, signal acquisition, algorithm execution and results display part. To implement real time system, all of the parts were programmed by the LabVIEW which is one of the graphical programming languages. Using the application software implemented by the LabVIEW, we were able to design a proper reference signal which is suitable for target cable and control not only the arbitrary waveform generator in the signal generation part but alto the digital storage oscilloscope in the signal acquisition part. By using the TFDR real time system with the terminal resistor on the target cable, we carried out load impedance measurement experiments. The experimental results showed that the proposed system are able not only to detect the location of impedance discontinuity on the cable but also to estimate the load resistance with high accuracy.

Location of Recent Micro-earthquakes in the Gyeongju Area (최근 경주지역 미소지진 진원 위치)

  • Han, Minhui;Kim, Kwang-Hee;Son, Moon;Kang, Su Young;Park, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.2
    • /
    • pp.97-104
    • /
    • 2016
  • Small to large earthquakes have been reported in Gyeongju and its vicinity in southeast Korea during historical period as well as instrumental observation period. We identified and located more than 300 earthquakes that occurred between January 2010 and December 2014 in a $20km{\times}30km$ area, but were unreported because of their small magnitudes. We used the Joint Hypocenter Determination (JHD) method to minimize the influence of the differences between the actual earth structure and 1-D velocity model for earthquake locations. The potential relationship between the previously reported Quaternary faults and the earthquake hypocenters was investigated. Many micro-earthquakes were found to be located in the southern segment of the Yeonil Tectonic Line, the Seokup fault, and the Waup basin boundary faults.

Case history of electrical resistivity survey at the river for bridge design (장대교량 기초 설계를 위한 수륙혼합 전기비저항탐사 사례)

  • Chung Ho-Joon;Kim Jung-Ho;Kwon Hyoung-Seok;Ahn Hee-Yoon;Kim Ki-Seog
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.126-138
    • /
    • 2002
  • Designing the bridge with wider span is the present-day trends. Therefore, constructing the foundation on the suitable ground is one of the important factor for the safety of bridge. But, getting a subsurface information under the river is not easy problem. This paper shows results of electrical resistivity survey at the river. Electrical resistivity survey have revealed geoelectrical structure successfully. The result is well matched with boring and can provide useful information on the geological structure such as fault fracture zone for suitable location of foundation. It is expected that application of electrical resistivity survey at the river will be helpful in preventing modification of design due to unexpected ground condition during the construction, or water contamination and increment of costs accompanied with ground reinforcement.

  • PDF