• Title/Summary/Keyword: fault lines

Search Result 356, Processing Time 0.038 seconds

Analysis on Recovery in Au/YBCO thin Film Meander Lines (Au/YBCO 박막 곡선에서의 회복 분석)

  • Kim, H.R.;Yim, S.W.;Oh, S.Y.;Hyun, O.B.
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.119-125
    • /
    • 2007
  • We investigated recovery in $Au/YBa_2Cu_3O_7$ (YBCO) thin film meander lines on sapphire substrates. The meander lines were fabricated by patterning YBCO films coated with gold layers. The lines were subjected to simulated AC fault current and then small current was applied for recovery measurements. The samples were immersed in liquid nitrogen during the experiment. After the fault, the resistance decreased linearly, first slowly and then fast to zero. The initial slow decrease was due to the decrease of the meander line temperature, whereas the fast decrease was originated from the transition from the normal state to the superconducting state. The recovery speed depended on the size of samples, and was faster in the smaller samples during the whole period of recovery. The experimental results were analyzed quantitatively with the concept of heat transfer within the sample and to the surrounding liquid nitrogen. A heat balance equation was solved for the initial phase of recovery, and an expression for the time dependence of resistance was obtained. The result agreed with data well.

  • PDF

Design of SPS in the Korean Power System Against Faults on 765 KV Lines

  • Park Jong-Young;Park Jong-Keun;Jang Byung-Tae
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.132-137
    • /
    • 2005
  • In Korea, the protection systems against the instability of the nation's power system are insufficient in contrast with many other countries. In addition, there have just been studies carried out on detecting power system instability, while only a few studies pertaining to protection plans against instability exist. This paper focuses on systems to protect against the instability phenomena in the Korean power system. In this paper, we survey possible contingencies in the Korean power system and suggest outline and specs of the SPS (System Protection Scheme) against faults on the 765 kV line, based on simulations. It is concluded that event-based SPS for transient stability is appropriate for the Korean power system. In the simulations, the most severe contingency on the Korean power system is the fault on 765 kV transmission lines. If one of these lines is tripped by a fault, synchronism may be lost on the power plants near this line because of heavy power flow carried by them. In addition, undervoltage in the Metropolitan region is a serious problem in this case since this region receives about half its total power flow through these lines. In order to prevent a synchronism loss, some power plants have to be rejected according to the situations in the simulations.

Analysis of Simulation Results for Secondary Arc in 765kV single transmission line (765kV 1회선 선로의 2차아크 모의결과 분석)

  • Ahn, S.P.;Kim, C.H.;Park, N.O.;Ju, H.J.;Shim, E.B.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.36-38
    • /
    • 2004
  • In many countries, including Korea, in order to transmit the more electric power, the higher transmission line voltage is inevitable. So, a rapid reclosing scheme is important for UHV transmission lines to ensure requirements for high reliability of main lines. But, because of the high voltage and long span of UHV lines, the secondary arc current flows across the fault point even after the interruption of the fault current. i.e. A critical aspect of reclosing operation is the extinction of the secondary arc since it must extinguish before successful reclosure can occur. In Korea transmission lines, it is scheduled to energize 765kV single transmission line(79km) between Sin-Ansung S/S and Sin-Gapyeong S/S at June 2006. Therefore this paper analyzes characteristics of the secondary arc extinction on 765kV single transmission line using EMTP. Simulation results shows that the average value of the secondary arc is $30A_{rms}$ and the auto-extinction time of it is longer at closer point to Sin-Gapyeong S/S.

  • PDF

A study on the fault diagnosis in the power system using Neural Network (신경회로망을 이용한 전력계통의 고장진단에 관한 연구)

  • Park, June-Ho;Choi, June-Hyug;Lee, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.43-46
    • /
    • 1991
  • When a fault is occurred in Power System, relay system detect overcurrent or voltage drop and trip the circuit breaker. Then, an operator in the control room diagnoses the fault and start the recovery of the system after analyzing the alarm information of relays or circuit breakers. The alarm informations have different patterns for each fault of the electric equipments on lines in power systems. In this paper, Back propagation algorithm is applied to train for many kinds of the fault in the power system. The simulation results show the possibility of the neural network application for the fault diagnosis in the case of errorous operation as well as normal operation of relays or circuit breakers.

  • PDF

A Study on the Development of GUI Software using MATLAB (MATLAB을 이용한 GUI 소프트웨어 개발에 관한 연구)

  • Kim, B.C.;Kim, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.449-451
    • /
    • 2000
  • Arcing fault on overhead lines can be detected by amplitude of the arc voltage using numerical algorithm. In the case of transient fault, the arc voltage has any high value. In the case of permanent fault, the arc voltage is near zero. Thus, fault distance estimation should be performed by digital distance relay algorithm[3]. The purpose of this study is to build a structure for modeling of arcing fault detection and fault distance estimation algorithm using Matlab programming. Additionally, this algorithm has been designed in Graphical User Interface(GHI). So, this method using GUI interface of Matlab can reduce the number of simulation steps in modeling the distance relay.

  • PDF

Fault Location in Combined Transmission Systems Using Wavelet Transform (웨이브렛 변환을 이용한 혼합송전계통에서의 Fault Location)

  • Jung, Chae-Kyun;Hong, Dong-Suk;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.226-229
    • /
    • 2001
  • The combined transmission lines with the underground power cables are continuously expanded in power systems. So the fault of combined transmission line is increased every year as the complication of underground transmission line. In this paper. traveling wave theory and DWT wavelet transform are used for fast and accurate detection of fault location at the combined transmission line. Traveling wave travels to each bus like surge and repeats reflection and transmission till transient signal is completely disappeared. When fault is occurred on overhead and underground tine, the fault location detecting algorithm was performed with using continuous peak value time-delay of traveling wave reflected from A bus.

  • PDF

Quench propagation in resistive SFCL (저항형 초전도 한류기에서의 퀀치 전파)

  • 김혜림;현옥배;최효상;황시돌;김상준
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.4
    • /
    • pp.337-342
    • /
    • 2000
  • We fabricated resistive superconducting fault current limiters based on YB $a_{2}$/C $u_{3}$/ $O_{7}$ thin films and investigated their quench propagation characteristics. The YB $a_{2}$/C $u_{3}$/ $O_{7}$ films was coated with a gold layer and patterned into 1 mm wide meander lines by photolithography. The quench was concluded to start locally and propagates until completed. The quench propagation characteristics were explained based on the heat transfer within the film as well as between the film and the surrounding liquid nitrogen. The quench completion time depended strongly on potential fault current amplitude and not significantly on fault angle which indicates that the quench propagation speed is affected more by heat dissipation rate than by fault current increase rate. The quench completion time was 1 msec at the fault current of 65 $A_{peak/{\ak}}$.

  • PDF

On Fault Current Limitering and Design Method of the Specific Parameter of Superconducting Fault Current Limiter (초전도고장전류제한기의 고장전류억제효과와 동작파라메타 설정방법에 대한고찰)

  • Hong, Won-Pyo;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.972-974
    • /
    • 1997
  • Design & Operation of power system for meeting increase of electric Power demand is becoming more difficult and complex. One of reasons is increase of fault current. As one of the most effective methods for suppressing the fault current installation of SFCL is expected. These paper describes a method of fault analyses of power system with SFCLs, and also discusses determination of specification of SFCLs, effects of limiting the fault current due to SFCLs by use of the model system of two - bus electric power system with single transmission lines.

  • PDF

Quench propagationin resistive SFCL (저항형 초전도 한류기에서의 퀀치 전파)

  • 김혜림;현옥배;최효상;황시돌;김상준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.85-88
    • /
    • 1999
  • We fabricated resistive superconducting fault current lmiters based on YBa$_2$Cu$_3$O$_{7}$ thin films and investigated their quench propagation characteristics. The YBa$_2$Cu$_3$O$_{7}$ film was coated with a gold layer and patterned into 1 mm wide meander lines by photolithography. The limiters were tested with simulated fault currents of various fault angles and amplitudes. The quench propagation characteristics were explained based on the heat transfer within the film as well as between the film and the surrounding liquid nitrogen. The quench completion time strongly depended on the potential fault current. It was 1 msec at the peak fault current of 76 A/peak/ and corresponding quench propagation speed was 43 m/sec (film cross section: 4 x 10$^{-6}$ $\textrm{cm}^2$).

  • PDF

Current Distribution Factor Based Fault Location Algorithms for Double-circuit Transmission Lines (전류분배계수를 사용하는 병행 2회선 송전선로 고장점 표정 알고리즘)

  • Ahn, Yong-Jin;Kang, Sang-Hee;Choi, Myeon-Song;Lee, Seung-Jae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.3
    • /
    • pp.146-152
    • /
    • 2001
  • This paper describes an accurate fault location algorithm based on sequence current distribution factors for a double-circuit transmission system. The proposed method uses the voltage and current collected at only the local end of a single-circuit. This method is virtually independent of the fault resistance and the mutual coupling effect caused by the zero-sequence current of the adjacent parallel circuit and insensitive to the variation of source impedance. The fault distance is determined by solving the forth-order KVL(Kirchhoff's Voltage Law) based distance equation. The zero-sequence current of adjacent circuit is estimated by using a zero-sequence current distribution factor and the zero-sequence current of the self-circuit. Thousands of fault simulation by EMTP have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF