• 제목/요약/키워드: fault inspection

검색결과 115건 처리시간 0.023초

철도급전시스템의 신뢰도기반 점검주기 산정 (The Evaluation of Inspection Period based on Reliability in Railway Traction Power Systems)

  • 김형철
    • 전기학회논문지
    • /
    • 제62권8호
    • /
    • pp.1177-1183
    • /
    • 2013
  • In this paper, the analysis of inspection period bases on reliability is suggested in the field of traction power system. Even though there are several maintenance models, the most commonly used maintenance assessment has been focused on time based maintenance in real traction power systems. The maintenance intervals are selected on the basis of long-time experience. It ensures high availability and exact planning of staff. Reliability centered maintenance, which evaluates criticality and severity of each failure mode, achieves the operation, maintenance, and cost-effective improvement that will manage the risks of equipment. This paper deals with electrification in railway inspection frequency and applied reliability based inspection frequency instead of constant intervals. The distribution function of failure rate in traction power system belongs to Weibull function. Also, the fault data and the number of installed equipments for electrifications are collected. The failure history is investigated and classified in detail. Though these complicated procedures, it contribute to extend equipment lifetime and to reduce maintenance costs.

초음파를 이용한 감자의 내부결함검사 (Ultrasonic Inspection of Internal Defects of Potatoes)

  • 김인훈;정규홍;장경영;서륜;김만수
    • 한국정밀공학회지
    • /
    • 제20권3호
    • /
    • pp.82-88
    • /
    • 2003
  • The nondestructive internal quality evaluation of agricultural products has been strongly required from the needs for individual inspection. Recently, the ultrasonic wave has been considered as a solution fur this problem, and an ultrasonic system was constructed for the ultrasonic NDE of fruits and vegetables in our previous work. In this paper, the practical applicability of our ultrasonic system is tested fur the inspection of internal defects (central cavity) in Atlantic potato. Sound speed and RMS of transmitted ultrasonic wave signal were measured and classification algorithm using 2 dimensional stochastic analysis. was presented. Experimental results showed greater value of sound speed and RMS (root mean square) of transmitted signal in normal samples than in abnormal samples with cavity. Also a stochastic method to distinguish normal and abnormal showed fault detection rate less than 5%.

Object Dimension Estimation for Remote Visual Inspection in Borescope Systems

  • Kim, Hyun-Sik;Park, Yong-Suk
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권8호
    • /
    • pp.4160-4173
    • /
    • 2019
  • Borescopes facilitate the inspection of areas inside machines and systems that are not directly accessible for visual inspection. They offer real-time, up-close access to confined and hard-to-access spaces without having to dismantle or destructure the object under inspection. Borescopes are ideal instruments for routine maintenance, quality inspection and monitoring of systems and structures. The main application being fault or defect detection, it is useful to have measuring capability to quantify object dimensions in a target area. High-end borescopes use multi-optic solutions to provide measurement information of viewed objects. Multi-optic solutions can provide accurate measurements at the expense of structural complexity and cost increase. Measuring functionality is often unavailable in low-end, single camera borescopes. In this paper, a single camera measurement solution that enables the size estimation of viewed objects is proposed. The proposed solution computes and overlays a scaled grid of known spacing value over the screen view, enabling the human inspector to estimate the size of the objects in view. The proposed method provides a simple means of measurement that is applicable to low-end borescopes with no built-in measurement capability.

드론을 이용한 태양광 발전소 고장 점검 (Detecting Fault of Solar Plant using Drone)

  • 김동균;박관남;조상윤;이영권;유권종;정문호;최익;최주엽
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.471-472
    • /
    • 2016
  • Since photovoltaic generating system is significantly important among renewable energy sources, photovoltaic plants are installed more than past. As a result, accidents of photovoltaic system are also increased, so the additional hardware which includes monitoring system and periodic inspection are required for safety. In addition, a photovoltaic system is installed where a person can't approach to detect a fault, so a number of devices are required to detect it. This paper proposes that drone and thermo-graphic camera are used for detecting a fault of photovoltaic plant and suggests efficiency to control a drone for detecting a photovoltaic plant.

  • PDF

BLDC 모터 제어보드 이상상태 검출에 관한 연구 (Fault Detection of the BLDC Motor Control Board)

  • 조성오;조내수;권우현;임성운;윤경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.66-68
    • /
    • 2005
  • DC motor is easy to control and can make torque easily. DC motor uses wide range. But DCmotor have limited by using a brush and structural complexity. But, BLDC doesn't have brush so that is more simple than DC motor, and the rotor of BLDC motor is made by permanent magnet that dose not need to make a fixed flux speed for flux current. BLDC motor is very efficiency, controllable, and reliable. This paper presents an error detection with a BLDC motor current. Generally, BLDC motor current is used to current feedback, so that can make a critical fault in the system. this paper suggests to detect error by inspection of threshold current value both positive and negative.

  • PDF

선단유압재하시험을 이용한 단층파쇄대에 설치된 대구경 현장타설말뚝의 선단지지력 측정 사례 (Case Studiy on Measurement of End Bearing Capacity for Large Diameter Drilled Shaft Constructed in Fault Zone using Loading Test)

  • 정창규;김태훈;정성민;황근배;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.74-81
    • /
    • 2004
  • In this study, static end loading tests with load transfer measurement were accomplished for large diameter drilled shaft constructed in fault zone. Yield pile capacity (or ultimate pile capacity) from load-settlement curve was determined and axial load transfer behavior was measurd. The end bearing capacity was increased 2 times due to grouting the toe ground under pile base.

  • PDF

PIC Controller를 이용한 키패드 검사 시스템 개발 (Development of Keypad Test System using PIC Controller)

  • 최광훈;이영춘;권대규;이성철
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.94-101
    • /
    • 2004
  • This paper presents the development of a keypad test system for the improvement of working environment and productivity using PTC 16F877 microprocessor. In order to detect the fault of keypad products, hardware and software design is performed in this system. Keypad fault detection system is controlled by the 8 bit one chip PIC microcontroller for the exactness and speed. Developed panel of the keypad test system is comprised of the sub-panel for selecting in the inspected keypad types and the main panel f3r displaying the working order and fault position. Furthermore, all data from keypad inspection are stored in main memory of personal computer for the database. All these functions lead to the improvement of working speed and environment.

LPI차량에서 CKPS불량으로 주행 중 간헐적인 엔진부조 현상의 고장진단 (Case Study of Intermittent Engine Hesitation Fault Diagnosis By CKPS Fault)

  • 김성모
    • 한국생산제조학회지
    • /
    • 제23권6호
    • /
    • pp.624-629
    • /
    • 2014
  • The purpose of this study is to carry out the task of engine hesitation which occurred intermittently in driving due to the defective CKPS of LPI vehicles. As the result of the wrong data from the equipment of D-logger, the signal error of CKPS caused the engine hesitation. We performed a study in the followings to analyze and investigate the cause effectively. First, we have investigated the control wiring harness and connector pin contact defect inspection. Second, we have inspected the defection of CKPS separately. From this study, it was found that the engine hesitation were caused by the bad durability and we have showed how to diagnosis the fault of the engine hesitation intermittently while driving. Therefore, it is determined that we have to improve the durability of the CKPS through a strict quality control and to increase the reliability.

RCM 기반 철도시설물 고장분석시스템 구축 - 서울메트로 - (A Study on Constructing the RCM-based Failure Analysis System for Railway Facilities & Equipments)

  • 정관수;서광혁;이정주;남진근
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.881-895
    • /
    • 2011
  • Seoul Metro railway facilities' inspection and maintenance tasks cause failure analysis, but if there is trouble the diverse cause investigation and the systematic analysis and management among broken facilities, related facilities and components fell short and the conditions are different. And, excess and insufficiency, under inspection and maintenance, is being raised regardless of the introduction year and the operating environment including the number of use by applying the same facilities in the uniform inspection cycle. In this study, we will analysis systematically facility system information, failures, operational status, performance, fault and maintenance information resulting from the maintenance management of railway facilities and derive the relationship between associated equipment and its components. In addition, optimizing the inspection and the maintenance cycles of railway facilities, we will improve the reliability of operation. Considering the probability of risk, it is possible to predict the occurrence of accidents or faults and to minimize the frequency of breakdown by pre-inspection maintenance. Finally, This paper is to introduce the content of constructing the Seoul Metro RCM-based failure analysis system for railway facilities to support the optimal continuance of operation status of equipments and the securement of the safe operation of vehicles.

  • PDF