• 제목/요약/키워드: fault area

검색결과 802건 처리시간 0.026초

SVM을 이용한 TFT-LCD 모듈공정의 불량 진단 방안 (A Fault Diagnosis Methodology for Module Process of TFT-LCD Manufacture Using Support Vector Machines)

  • 신현준
    • 반도체디스플레이기술학회지
    • /
    • 제9권4호
    • /
    • pp.93-97
    • /
    • 2010
  • Fast incipient fault diagnosis is becoming one of the key requirements for economical and optimal process operation management in high-tech industries. Artificial neural networks have been used to detect faults for a number of years and shown to be highly successful in this application area. This paper presents a novel test technique for fault detection and classification for module process of TFT-LCD manufacture using support vector machines (SVMs). In order to evaluate SVMs, this paper examines the performance of the proposed method by comparing it with that of multilayer perception, one of the artificial neural network techniques, based on real benchmarking data.

Intelligent Data Reduction Algorithm for Sensor Network based Fault Diagnostic System

  • Youk, Yui-Su;Kim, Sung-Ho;Joo, Young-Hoon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제9권4호
    • /
    • pp.301-308
    • /
    • 2009
  • In the modern life, machines are used for various areas in industries as the advance of science and industrial development has proceeded. In many machines, the rotating machines play an important role in many processes. Therefore, the development of fault diagnosis and monitoring system for rotating machines is required. An ubiquitous sensor network (USN) is a combination of the key computer science and engineering area technology including the wireless network, embedded system hardware and software, communication, real-time system, etc. It collects environmental information to realize a variety of functions. In this work, a data reduction algorithm for USN based remote fault diagnostic system which can be easily applied to previously built factories is proposed. To verify the feasibility of the proposed scheme, some simulations and experiments are executed.

양산-울산 단층계와 후타가와-히나구 단층계의 비교를 통한 지진발생특성 연구 (Research on Earthquake Occurrence Characteristics Through the Comparison of the Yangsan-ulsan Fault System and the Futagawa-Hinagu Fault System)

  • 이진현;권세현;김영석
    • 암석학회지
    • /
    • 제25권3호
    • /
    • pp.195-209
    • /
    • 2016
  • 현생 응력장 하에서 주향이동단층계의 기하적인 형태는 단층의 재활 및 이에 수반된 지진의 전파와 지표파괴의 특성을 좌우하는 중요한 요인이다. 2016년 4월에 발생한 구마모토지진은 동-서 방향으로 작용하는 최대수평주응력 하에서 북북동 방향의 히나구 단층이 동북동 내지 북동방향의 후타가와 단층에 기하학적으로 ${\lambda}$형태를 이루며 접하는 후타가와-히나구 단층대의 우수향 재활에 의한 것으로 해석된다. 히나구 단층의 북동측 끝부분에서 구마모토 지진의 전진($M_w$ 6.1)이 발생한 이후, 본진($M_w$ 7.1)이 두 단층의 연결부에서 발생하였다. 본진에 연이어 발생한 여진은 후타가와 단층을 따라 북동방향으로 전파되어 아소산 지역에서 종결된 특징을 보인다. 구마모토 지진을 유발시킨 단층들이 이루는 기하적인 형태는 한반도 남동부지역에 발달하는 대표적인 대규모 활성단층으로 인식되고 있는 양산-울산 단층계와 매우 흡사하고 변형율이 차이가 난다. 양산-울산 단층계을 따라 발달하는 제4기 단층들의 연대분포는 양산단층의 북쪽 분절과 울산단층 일대에서 발달하는 제4기 단층들이 양산단층의 남쪽분절에 발달하는 제4기 단층들보다 상대적으로 더 젊은 특징을 보여주고 있다. 이러한 제4기 단층의 연대분포는 쿨룸 응력 모델링을 이용한 기존 연구결과와도 잘 일치한다. 따라서 현생응력조건 하에서 양산-울산단층계 일대의 지진 활성도는 양산단층의 중부 및 북쪽 분절과 울산단층에서 상대적으로 활발할 것으로 해석된다. 따라서 이 지역에 대한 면밀한 지진재해와 고지진학적 연구가 수행되어야 할 것으로 판단된다.

단양지역의 지질구조 (Structural Analysis of the Danyang Area, Danyang Coalfield, Korea)

  • 김정환;고희재
    • 자원환경지질
    • /
    • 제25권1호
    • /
    • pp.61-72
    • /
    • 1992
  • 단양지역은 단양탄전 서남부에 위치하며, 습곡작용과 드러스트 단층운동을 받은 중생대와 고생대 지층들로 구성되어 있다. 연구지역은 대규모의 조구조선, 동으로는 옥동단층과 서쪽에는 각동 드러스트 단층으로 경계지워져 있다. 연구지역내에 발달하고 있는 지질구조 요소들을 해석한 결과 연구지역내의 지층들이 4번에 걸쳐서 변형작용을 받았다. 옥동단층을 따라서 발달하고 있는 압쇄대는 첫번째 변형작용($D_1$) 중에 형성되었으며, 이와 관련된 구조로는 장산규암층내에 불연속적으로 발달하고 있는 압쇄대와 조서누층군내의 지층에 평행하게 발달한 인장(引長, pull-apart)구조들이 관찰된다. 두번째 변형작용중에 형성된 지질구조($D_2$)로는 북서방향의 습곡구조와 선구조들이며, 이러한 구조들은 대동 누층군 내에서는 관찰되지 않는다. 한반도 전역에 영향을 준 대보조산운동의 결과로 형성된 지질 구조들로는 ($D_3$) 각동 드러스트를 비롯한 북동방향의 드러스트 단층들과 습곡구조 등이다. 이 기간 동안에 기존의 지질구조들은 더 tight해졌으며, 변형되고 북동방향으로 회전되었다. 최후기의 변형작용($D_4$) 중에 동-서 방향의 죽령단층과 미약한 습곡구조가 형성되었다. 죽령단층내의 지층들은 주향이동 단층운동중에 회전되고 transpression의 영향을 받았다.

  • PDF

울산광역시 울주군 삼남면 일대에 발달한 양산단층대의 제4기 단층운동 (Quaternary Fault Activity of the Yangsan Fault Zone in the Samnam-myeon, Ulju-gun, Ulsan, Korea)

  • 양주석;이희권
    • 자원환경지질
    • /
    • 제47권1호
    • /
    • pp.17-27
    • /
    • 2014
  • ESR 연대를 이용하여, 울산광역시 울주군 삼남면 일대에 발달하는 양산단층대의 시간-공간적 활동 형태에 대해 연구하였다. 연구지역에서 일부 단층비지대는 기 형성된 단층비지 옆에 새로운 단층비지가 단층활동 형태 I에 의해 첨가되어 있다. 이럴 경우 각각의 단층비지에서 얻은 ESR 연대로부터 여러 번의 단층활동 시기를 해석하였다. 단층비 지대에서 일부분은 단층활동 형태 III에 의해 단층비지대 전체가 재 활동 하였다. 이와 같은 단층비지대는 이전의 활동 정보는 모두 지워지고 마지막 활동 시기만 기록되어 있다. 연구지역에서 양산단층대의 제4기 단층운동은 주기성을 가지며 활동기와 휴식기로 구분된다. ESR 연대 및 트렌치 조사 자료에 의하면, 연구지역에서 양산단층대의 단층활동은 이동하는 경향을 나타낸다. 약 75~85만 년 전을 기준으로 이전에는 서쪽분절로부터 북쪽분절까지, 약 75~85만년 전에는 동쪽분절로부터 북쪽분절까지 활동하였으며, 약 63~66만 년 전 및 48~54만 년 전에는 북쪽분절만 활동하였으며, 약 34만 년 전 이후에는 서쪽분절로부터 북쪽분절까지 다시 활동하였다.

화북댐 상류지역을 통과하는 우보단층 파쇄대 영향분석을 위한 지화학적 접근 (Geochemical Approach to Define the Fracture Bone Affected by the Ubo Fault at the Northern Part of the Hwabuk Dam)

  • 권용완
    • 암석학회지
    • /
    • 제13권4호
    • /
    • pp.191-200
    • /
    • 2004
  • 경북 군위군 학성리 화북댐 건설예정지 북측 1km지점을 북서-남동방향으로 통과하는 우보단층은 20km 내외의 연장을 가지는 대단층이다. 이 지역에서 우보단층은 소규모의 단층들로 분절되며 인접 지역에 비해 단층의 영향이 적고 낮은 구릉형 지형을 형성하며 화북댐 우안의 분수령을 통과한다. 저수유역내에 2매의 단층이 통과하며 파쇄대의 영향범위는 2m 내외로 관찰된다. 지화학분석을 통해 파쇄대 영향범위를 평가하기 위해 주단층면을 중심으로 남북방향으로 각각 0.5m, 1m, 2m, 4m, 8m, 16m, 32m구간에서 시료를 채취하여 주성분원소와 광물함량비를 분석하였다. 파쇄대에 근접할수록 Fe$_2$O$_3$, MgO, $K_2$O, 석영, 백운모, 녹니석은 증가하는 경향을 보이며, $Na_2$O, CaO, 사장석, 흑운모는 감소하는 경향을 보인다. 화학조성과 광물함량비를 기초로 학성리일대를 통과하는 우보단층의 파쇄대 영향범위는 중심지역이 총 2m의 폭을 보이며 2차 영향대는 총 8m의 폭을 이룬다. 우보단층의 최대 영향범위는 총 16m의 폭을 가지는 것으로 추정하였다.

의성지역 백악기 암석에 대한 고자기 연구 (Palaeomagnetism of Cretaceous Rocks in the Ǔisǒng Area, Kyǒngsang Basin, Korea)

  • 김인수;이현구;윤혜수;강희철
    • 자원환경지질
    • /
    • 제26권3호
    • /
    • pp.403-420
    • /
    • 1993
  • The Cretaceous Kyongsang Basin is known to be composed of several tectonic blocks (or subbasins) with each distinct stratigraphic succession. The study area represents a major part of one of these blocks, i. e. the $\check{U}is\check{o}ng$ block. The area is charaterized by a suite of WNW-trending sinistral strike-slip faults as well as a number of ring faults. A total of 292 independently oriented core samples were drilled from 23 sites, covering virtually all the formations of the Cretaceous $Ky\check{o}ngsang$ Supergroup. Alternating field and thermal demagnetization experiments were conducted to reveal the primary magnetization. Due to the homoclinal nature of the strata in the area, it was not possible to make use of the conventional fold test It is, however, believed that the primary remanent components have been obtained from the majority of the formations, considering the similarity of the palaeomagnetic pole positions with those of contemporary strata of other blocks and the existence of antiparallel reversed remanence. It was found neither any significant difference in magnetic declination on each side of the strike-slip faults nor systematic change of magnetic declination with distance from the fault-line. This does not support such a block rotation hypothesis associated with the strike-slip faulting in the area as alleged by some authors. The samples from the outcrops on or near the fault-lines were severely overprinted by the recent magnetic fields regardless of age and lithology. Epithermal Au-Ag-Cu-Pb-Zn mineralizations are known along some fault lines in the area. It is interpreted that these two facts are closely related with fluid circulations along the fracture zones caused by fault activities. In regard to the age of the strata as deduced from the magnetostratigraphic consideration, the $Ch\check{o}mgok$ formation and the lower strata should be older than Barremian or 124 Ma. The age of volcanics of the $Yuch^{\prime}\check{o}n$ Group sampled in this study should be younger than Campanian or 83 Ma.

  • PDF

2차원 전기비저항 탐사를 이용한 경주 개곡리 지역의 단층조사 (Investigation of fault in the Kyungju Kaekok-ri area by 2-D Electrical Resistivity Survey)

  • 이치섭;김희준;공영세;이정모;장태우
    • 지구물리와물리탐사
    • /
    • 제4권4호
    • /
    • pp.124-132
    • /
    • 2001
  • 경주 개곡리 지역에서 단층 파쇄대와 지하 내부구조를 파악하기 위해 전기비저항 탐사를 실시하였다. 지층의 전기전도도 분포는 공극수의 함량, 지하수, 공극률 및 점토광물 등의 많은 요인에 의해 지배되고, 이러한 특징은 지층의 풍화상태와 정도, 단층 파쇄대를 간접적으로 설명하는 증거가 된다. 따라서 전기비저항 탐사는 지표에 드러나지 않아 그 연장성이 확실하지 않은 단층 파쇄대를 탐지하기에는 좋은 방법이다. 단층구조를 해석하기 위한 2차원 전기비저항 역산 기법으로 평활화제약 최소자승법을 이용하였고, 모형반응의 계산은 지형의 기복을 고려하기 위해 유한요소법을 사용하였다. 본 연구에 이용된 야외자료는 울산단층에 인접한 경주 외동읍 개곡리 부근의 제 4기 단층 파쇄대로 추정되는 곳에서 쌍극자배열을 이용하여 획득하였다. 이들 자료를 역산하여 전기비저항 2차원 단면도를 작성한 결과, 단층 파쇄대의 특징을 잘 보여주는 것으로 나타났다. 본 연구의 결과, 경주시 외동읍 개곡리 제 4기 단층은 노두에서부터 총 50m까지 단층의 연장이 확인되었으며 그 연장 방향은 $N80^{\circ}W$임이 밝혀졌다. 본 연구를 통해 단층 조사에 있어 2차원 전기비저항 탐사해석이 유용하게 적용될 수 있음을 보여주었다.

  • PDF

센서 네트워크 시스템에 적용 가능한 고장 검출 알고리즘 개발 (Development of Fault Detection Algorithm Applicable to Sensor Network System)

  • 육의수;윤성웅;김성호
    • 한국지능시스템학회논문지
    • /
    • 제17권6호
    • /
    • pp.760-765
    • /
    • 2007
  • 센서 네트워크 시스템은 한정된 자원을 갖는 센서노드들을 광대한 영역에 설치하여 새로운 정보를 수집하고 모니터링하는 기능을 한다. 센서 노드와 센서의 고장(Sensor node faulty or Sensor faulty)은 열악한 설치 환경이나 제한된 리소스에 의해 종종 발생되는데 이들 고장은 네트워크 내에서 요구되는 양질의 서비스 제공에 많은 문제를 가져온다. 본 논문에서는 센서 노드의 고장 검출 알고리즘으로 알려져 있는 Consensus 알고리즘과 센서노드에서 사용되는 센서의 고장을 검출할 수 있는 localized faulty sensor detection 알고리즘을 혼합하여 시스템에 안정된 서비스를 제공할 수 있는 방법을 제안하며 실제 시뮬레이션과 제작된 실험장치에 적용함으로써 그 유용성을 확인하고자 한다.

A Study on the Application Impacts on Korean Power System by Introducing SFCL

  • Kim, Jong-Yul;Park, Heung-Kwan;Yoon, Jae-Young
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권1호
    • /
    • pp.1-6
    • /
    • 2003
  • As power systems grow more complex and power demands increase, the fault current tends to gradually increase. In the near future, the fault current will exceed a circuit breaker rating for some substations, which is an especially important issue in the Seoul metropolitan area because of its highly meshed configuration. Currently, the Korean power system is regulated by changing the 154 ㎸ system configuration from a loop connection to a radial system, by splitting the bus where load balance can be achieved, and by upgrading the circuit breaker rating. A development project applying 154 ㎸ Superconducting Fault Current Limiter(SFCL) to 154 ㎸ transmission systems is proceeding with implementation slated for after 2010. In this paper, the resistive and inductive SFCLs are applied to re-duce the fault current in Korean power system and their technical and economic impacts are evaluated. The results show that the application of SFCL can eliminate the need to upgrade the circuit breaker rat-ing and the economic potential of SFCL is evaluated positively.