• Title/Summary/Keyword: fault area

Search Result 802, Processing Time 0.023 seconds

Defect Detection of Ship Engine using duplicated checking of vibration-data-distinction Method and Classification of fault-wave (이중화된 진동 정보 판별 기법과 고장 파형 분류를 이용한 선박 엔진의 고장 감지)

  • Lee, Yang-Min;Lee, Kwang-Young;Bae, Seung-Hyun;Shin, Il-Sik;Jang, Hwi;Lee, Jae-Kee
    • Journal of Navigation and Port Research
    • /
    • v.33 no.10
    • /
    • pp.671-678
    • /
    • 2009
  • Recently, there have been some researches in the equipment fault detection based on shock and vibration information. Most research of them is based on shock and vibration monitoring to determine the equipment fault or not. Different with engine fault detection based on shock and vibration information we focus on detection of engine for boat and system control. First, it use the duplicated-checking method for shock and vibration information to determine the engine fault or not. If there is a fault happened, we use the integral to determine the error engine shock wave width and detect the fault area. On the other hand, we use the engine trend analysis and standard of safety engine to implement the shock and vibration information database. Our simulation results show that the probability of engine fault determination is 98% and the probability of engine fault detection is 72%

Development of An Expert System to Decide the Resetting Area of Protective Distance Relay in Power Transmission Systems (송전계통 보호 거리계전기 재정정 영역 판정 전문가시스템 개발)

  • 최면송;민병운;김기화;현승호;이승재
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.8
    • /
    • pp.437-443
    • /
    • 2003
  • In this paper an expert system is developed to decide the resetting area of protective devices in power transmission systems. A configuration change in power transmission networks from a substation extension such as new line or bus addition need resetting of protective devices around the point of configuration changes. To find the resetting area in complex power system is very difficult, especially when the distance protective relays are considered to be reset. The proposed expert system, in this paper to find the resetting area has many rules based on the changes of fault currents and apparent factors from the power system alteration. It solves the problem to find relay resetting area using the network information in the database and the rule-base. The case study shows a result of the problem to find relay resetting area in KEPCO system when there is any configuration change.

A Development and utilization of Geotechnical Information System(GTIS) of the Rock Mass in Seoul Metropolitan Area(2) (서울일대 암반을 대상으로 한 Geotechnical Information System (GTIS)의 개발 및 활용 (2))

  • 김정엽;박형동
    • Tunnel and Underground Space
    • /
    • v.6 no.3
    • /
    • pp.223-233
    • /
    • 1996
  • Geotechnical Information System (GTIS) for efficient management of three dimensional borehole data has been developed. Geotechnical maps in the vicinity of Bulkwangdong, Seoul station, Itaewon, Han river near Yuido, and Jungrangchon were constructed by Kriging method. In Bulkwangdong and Jungrangchon area where boundary between granite and gneiss is present, gneiss has been more weathered than granite, but in Seoul station and Itaewon area where the boundary is also present, granite has been more weathered than gneiss. It has been inferred that when Seoul granite intruded, the strength of gneiss in Bulkwangdong and Jungrangchon area was lowered by the attitude of foliation plane than in Seoul station and Itaewon area, so the gneiss has been easily fractured and weathered in Bulkwangdong and Jungrangchon area. Geotechnical map in the vicinity of Yuido showed that there is an NW-SE trend weakness zone that might be affected by major faults under Han river and it is expected that the fault zone may be present in construction area of Kyoungbu Highspeed Railway that lies below the Han river like the Subway Line No.5.

  • PDF

Practical Construction of Tsunami Inundation Map to Link Disaster Forecast/Warning and Prevention Systems (예경보와 방재시스템의 연계를 위한 지진해일 범람도의 실용적 작성)

  • Choi, Jun-Woo;Kim, Kyung-Hee;Jeon, Young-Joon;Yoon, Sung-Bum
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.2
    • /
    • pp.194-202
    • /
    • 2008
  • In general, forecast tsunami heights announced for tsunami warning are computed by using a linear tsunami model with coarse grids which leads the underestimation of inundation area. Thus, an accurate tsunami inundation map corresponding the forecast tsunami height is needed for an emergency evacuation plan. A practical way to construct a relatively accurate tsunami inundation map was proposed in this study for the quantitative forecast of inundation area. This procedure can be introduced as in the followings: The fault dislocations of potential tsunami sources generating a specific tsunami height near an interested area are found by using a linear tsunami model. Based on these fault dislocations, maximum inundation envelops of the interested area are computed and illustrated by using nonlinear inundation numerical model. In this study, the tsunami inundation map for Imwon area was constructed according to 11 potential tsunami sources, and the validity of this process was examined.

Geological Survey in a Construction Area of Taegu-Pohang Highway (대구-포항간 고속도로 7공구의 지질조사 연구)

  • 이병주;선우춘;한공창
    • Tunnel and Underground Space
    • /
    • v.10 no.4
    • /
    • pp.497-505
    • /
    • 2000
  • The surveyed area is mainly distributed by the sedimentary rocks, tuffs, and esites in Cretaceous age and acidic and basic dikes are intruded in these rocks. The principle discontinuities are represented by beddings, joints and faults. The trends of the beddings of sedimentary rocks develop as E-W direction in the start area. However, they are gradually bending and finally their trends are N-S direction in terminal area. In the sedimentary rocks the 3∼4 joint sets are distributed and in dikes joints are more scattered. The majority of joints are highly dipped. Sampo fault which has NE-SW trend makes a valley and NW trending normal faults are well developed at 50k+600 to 51k+000 area. During the construction of tunnel the orientation of discontinuities will not significantly influence on the stability of excavation. Since the rock mass is extensively jointed, the overbreak in tunnel wall may be placed.

  • PDF

HVDC Application Considering Fault Current Characteristics (고장 전류 특성을 고려한 HVDC 적용 방안)

  • Park, Jung-Soo;Jang, Gil-Soo;Kim, Chan-Ki
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.239-246
    • /
    • 2007
  • One of the most serious problems in KEPCO power system is the load centralization in the capital area. The load capacity in the capital area is almost 40% of the total load. However, the generation capacity in this area is just 16% of the total generation. The inequality, between the power demand and supply, in this area needs the power transmission from other regions. The simplest method to solve the problem is the installation of power plants or the addition of high-capacity transmission line in the metropolitan area. However, because of the concentration of human and material resources, there is a difficulty in the installation of the generation and transformer facility. As a result, instead of the installation of large scale facilities, the approach to maximize the application of existing facilities is required. In this research, we will develop a scheme with an HVDC installation for enhancing power transfer capability by utilizing the existing transmission lines.

  • PDF

Application of SFCL on Bus Tie for Parallel Operation of Power Main Transformers in a Fuel Cell Power Systems

  • Chai, Hui-Seok;Kang, Byoung-Wook;Kim, Jin-Seok;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2256-2261
    • /
    • 2015
  • In the power plant using high temperature fuel cells such as Molten Carbonate Fuel Cell(MCFC), and Solid Oxide Fuel Cell(SOFC), the generated electric power per area of power generation facilities is much higher than any other renewable energy sources. - High temperature fuel cell systems are capable of operating at MW rated power output. - It also has a feature that is short for length of the line for connecting the interior of the generation facilities. In normal condition, these points are advantages for voltage drops or power losses. However, in abnormal condition such as fault occurrence in electrical system, the fault currents are increased, because of the small impedance of the short length of power cable. Commonly, to minimize the thermal-mechanical stresses on the stack and increase the systems reliability, we divided the power plant configuration to several banks for parallel operation. However, when a fault occurs in the parallel operation system of power main transformer, the fault currents might exceed the interruption capacity of protective devices. In fact, although the internal voltage level of the fuel cell power plant is the voltage level of distribution systems, we should install the circuit breakers for transmission systems due to fault current. To resolve these problems, the SFCL has been studied as one of the noticeable devices. Therefore, we analyzed the effect of application of the SFCL on bus tie in a fuel cell power plants system using PSCAD/EMTDC.

Quaternary Tectonic Activities and Seismic Stability of Suryum Fault and Yupchon Fault, SE Korea (수렴단층과 읍천단층의 제4기 활동 및 지진 안정성)

  • Hwang, Sangill;Shin, Jaeryul;Yoon, Soon-Ock
    • Journal of the Korean association of regional geographers
    • /
    • v.18 no.4
    • /
    • pp.351-363
    • /
    • 2012
  • Although the Korean peninsula has been considered as a largely aseismic region compared with the surrounding high seismic areas such as North China and Japan, there are more than thirty Quaternary faults reported so far, which are mostly centered in the southeastern peninsula. Structural studies of active faults exposed in Yangnam-myeon of Gyeongju, SE Korea are largely interpreted to post date the late Quaternary, suggesting that the NE-trending reverse faults may result from the active stress regime in the peninsula. The prevailing present-day E-W $S_{Hmax}$ orientations in the peninsula are consistent with the nature of plate forcing stemming from the convergence between the Indo-Australian and Eurasian plates. It is clear that the Quaternary faults have been reactivated, although resolving more elaborate time intervals responsible for a future rupture remains a significant challenge. This study contributes to better assess many of potential seismic hazards in the study area, in particular, in terms of seismic stability for foundation of nuclear power plant.

  • PDF

Nonlinear response of r.c. framed buildings retrofitted by different base-isolation systems under horizontal and vertical components of near-fault earthquakes

  • Mazza, Fabio;Mazza, Mirko;Vulcano, Alfonso
    • Earthquakes and Structures
    • /
    • v.12 no.1
    • /
    • pp.135-144
    • /
    • 2017
  • Near-fault ground motions are characterized by high values of the ratio between the peak of vertical and horizontal ground accelerations, which can significantly affect the nonlinear response of a base-isolated structure. To check the effectiveness of different base-isolation systems for retrofitting a r.c. framed structure located in a near-fault area, a numerical investigation is carried out analyzing the nonlinear dynamic response of the fixed-base and isolated structures. For this purpose, a six-storey r.c. framed building is supposed to be retrofitted by insertion of an isolation system at the base for attaining performance levels imposed by current Italian code in a high-risk seismic zone. In particular, elastomeric (e.g., high-damping-laminated-rubber bearings, HDLRBs) and friction (e.g., steel-PTFE sliding bearings, SBs, or friction pendulum bearings, FPBs) isolators are considered, with reference to three cases of base isolation: HDLRBs acting alone (i.e., EBI structures); in-parallel combination of HDLRBs and SBs (i.e., EFBI structures); FPBs acting alone (i.e., FPBI structures). Different values of the stiffness ratio, defined as the ratio between the vertical and horizontal stiffnesses of the HDLRBs, sliding ratio, defined as the global sliding force divided by the maximum sliding force of the SBs, and in-plan distribution of friction coefficient for the FPs are investigated. The EBI, EFBI and FPBI base-isolation systems are designed assuming the same values of the fundamental vibration period and equivalent viscous damping ratio. The nonlinear dynamic analysis is carried out with reference to near-fault earthquakes, selected and scaled on the design hypotheses adopted for the test structures.

Fault Diagnosis of Solar Power Inverter Using Characteristics of Trajectory Image of Current And Tree Model (전류 궤적 영상의 특징과 트리모델을 이용한 태양광 전력 인버터의 고장진단)

  • Hwang, Jae-Ho
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.4
    • /
    • pp.102-108
    • /
    • 2010
  • The photovoltaic system changes solar energy into DC by solar cell and this DC is inverted into AC which is used in general houses by inverter. Recently, the use of power of the photovoltaic system is increased. Therefore, the study of 3 phase solar system to transmit large power is very important. This paper proposes a method that finds simply faults and diagnoses the switch open faults of 3-phase pulse width modulation (PWM) inverter of grid-connected photovoltaic system. The proposed method in $\alpha\beta$ plane uses the patterns of trajectory image as the characteristic parameters and differenciates a normal state and open states of switches. Then, the result is made into tree. The tree is composed of 21 fault patterns and the parameters to classify faults are a shape, a trajectory area, a distributed angle, and a typical vector angle. The result shows that the proposed method diagnosed fault diagnoses, classified correctly them, and made a pattern tree by fault patterns.