• Title/Summary/Keyword: fat-based

Search Result 1,553, Processing Time 0.027 seconds

Effect of Health Promotion Programs in Schoolchildren (초등학교 학생을 대상으로 한 건강증진 프로그램의 효과)

  • Yoo, Joong-Sun;Kang, Pock-Soo;Lee, Kyeong-Soo;Kim, Seok-Beom;Choi, Kwang-Hae;Kim, Mee-Kyung
    • Journal of agricultural medicine and community health
    • /
    • v.25 no.2
    • /
    • pp.397-411
    • /
    • 2000
  • The present study was conducted to analyze the degree of changes in knowledge and attitude toward health, arid health promoting activities after providing health education intervention for a year to elementary school children, to examine the factors effecting knowledge, attitude and health promoting practices for obesity and diet, and to analyze whether changes are present in health level according to changes in knowledge on health and health promoting activities. After conducting a pre-survey rio 354 subjects of 3rd and 4th grade students and their mothers in the city area of Kyungju, in April, 1999, 301. responses with the responding rate of 85% were obtained. Final analysis was done with 231 pairs of a student and his/her mother who could be followed up after a year among 301 pairs of the respondents, excluding those students who transferred, those who were excused from school early, those who did not take abdominal fat measurements, and those students and mothers respondents whose survey was incomplete. Based on the changes before and after the intervention, the scores on knowledge about obesity and diet showed a significant difference in normal weight group, and the scores on the attitude toward obesity and diet increased significantly in obesity group but decreased significantly in normal weight group(p<0.01). The scores of practicing health promoting activities were significantly increased in both groups, and although the waist-hip ratio (WHR) did not change in obesity group, the rate increased significantly in normal weight group(p<0.01). As for changes on the knowledge of obesity and diet before and after the intervention while dividing the scores into 3 levels based on the scores of the pre-survey and compared to changes in the scores one year after, in the case of the changes in the scores in the 1st third, the score on the knowledge about obesity and diet changed from 1.3 in the pre survey to 3.7 after the intervention, showing significant increase(p<0.01) The scores of practicing health promoting activities for obesity and diet were significantly increase in all three levels(p<0.01), and the degree of changes in the scores was 7.0 points in the 1st third, 4.4 points for the and third and 1.8 points for the 3rd third, showing a significant difference among the three levels(p<0.01). It was shown that the increase in BMI in those students whose mothers have the education level higher than university was significantly higher than the increase in BMI in those students whose mothers have the education level under high school, and those students whose mothers are in their 30's showed higher changes in practicing health promoting activities for obesity and diet. When the scores of mothers' knowledge and attitude toward obesity and diet were compared by dividing the scores into tertile, the score of students' knowledge changed significantly according to the scores of mothers' attitude toward obesity and diet. In multiple regression analysis on changes in the scores of knowledge about obesity and diet, the student variables of the degree of awareness on the seriousness of obesity, and the scores of previous knowledge on diet and obesity were selected the significant variables, and among the mother variables, the degree of guiding the child on diet and the education level were the significant variables. In multiple regression analysis to analyze the factors effecting changes in the attitude toward obesity and diet, the student variables of the BMI, scores of previous knowledge on obesity and diet, and scores on the previous attitude toward obesity and diet were shown to be significant. In multiple regression analysis on the factors effecting changes in health promoting activities for obesity and diet, the student variables of the BMI, scores on the previous attitude toward obesity and diet, and changes in the scores of obesity and diet were selected the significant variables.

  • PDF

A Study on Serum Lipid Levels in Elderly People in Wando Area - Based on Age, BMI, WHR - (완도지역 성인 및 노인의 혈청지질 수준에 관한 연구(I) - 연령, 신체 계측치를 중심으로 -)

  • Cha, Bok-Kyeong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.1
    • /
    • pp.68-77
    • /
    • 2006
  • This study was peformed to document the association between nutrient intakes, body mass index (BMI), waist/hip ratio (WHR), and a major risk factor for chronic diseases. A three-day dietary intake survey, using a 24 hour recall method, was obtained from 187 subjects aged 46 to 84 (mean age 65.3) living in Wando island area. The average daily mean energy intakes were 1869.0 kcal for male and 1943.9 kcal for female, respectively. Daily intakes of protein for male and female were 28.0 and 30.4 g, and those of fat were 31.5 and 28.51 g, respectively Carbohydrate dependency was decreased with age. Protein dependency was increased with age. The mean intakes of energy, protein, Vit. A, Vit. D, Vit. E, Ca, Zn did not meet Korean RDA for elderly. The level of serum triglyceride was higher in males than in females and showed the tendency to increase with age in both sexes, whereas HDL-cholesterol tended to decrease with age in both sexes. The levels of serum total-cholesterol and LDL-cholesterol were significantly higher in males than in females, particularly in the age of $46\~59$ (p<0.05). The level of atherogenic index (AI) was significantly higher in females than in males, particularly in the age of 80 and over (p<0.05) Based on these results, it is evident that people in island area did not consume enough nutrient. Specially, dietary intake of protein was not adequate. This study implies that triglyceride, total-cholesterol, LDL-cholesterol, AI were increased with increasing age, BMI and WHR.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF