• Title/Summary/Keyword: fast-release

Search Result 170, Processing Time 0.028 seconds

Assessment of three European fuel performance codes against the SUPERFACT-1 fast reactor irradiation experiment

  • Luzzi, L.;Barani, T.;Boer, B.;Cognini, L.;Nevo, A. Del;Lainet, M.;Lemehov, S.;Magni, A.;Marelle, V.;Michel, B.;Pizzocri, D.;Schubert, A.;Uffelen, P. Van;Bertolus, M.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3367-3378
    • /
    • 2021
  • The design phase and safety assessment of Generation IV liquid metal-cooled fast reactors calls for the improvement of fuel pin performance codes, in particular the enhancement of their predictive capabilities towards uranium-plutonium mixed oxide fuels and stainless-steel cladding under irradiation in fast reactor environments. To this end, the current capabilities of fuel performance codes must be critically assessed against experimental data from available irradiation experiments. This work is devoted to the assessment of three European fuel performance codes, namely GERMINAL, MACROS and TRANSURANUS, against the irradiation of two fuel pins selected from the SUPERFACT-1 experimental campaign. The pins are characterized by a low enrichment (~ 2 wt.%) of minor actinides (neptunium and americium) in the fuel, and by plutonium content and cladding material in line with design choices envisaged for liquid metal-cooled Generation IV reactor fuels. The predictions of the codes are compared to several experimental measurements, allowing the identification of the current code capabilities in predicting fuel restructuring, cladding deformation, redistribution of actinides and volatile fission products. The integral assessment against experimental data is complemented by a code-to-code benchmark focused on the evolution of quantities of engineering interest over time. The benchmark analysis points out the differences in the code predictions of fuel central temperature, fuel-cladding gap width, cladding outer radius, pin internal pressure and fission gas release and suggests potential modelling development paths towards an improved description of the fuel pin behaviour in fast reactor irradiation conditions.

Development of the combustion noise index and control algorithm through signal processing of in-cylinder pressure for a diesel engine (연소압력 신호처리를 통한 디젤엔진 연소음 지수 및 제어 알고리듬 개발)

  • Jin, Jaemin;Lee, Dongchul;Jung, Insoo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.3
    • /
    • pp.208-215
    • /
    • 2016
  • To control and improve a combustion behavior of an engine, various studies for the in-cylinder pressure have been consistently carried out. In this paper, the level of the combustion noise for a diesel engine is estimated from the in-cylinder pressure and defined as the combustion noise index. The combustion noise index is calculated from the FFT(Fast Fourier Transform) of the in-cylinder pressure and its validity is verified. The control system based on the combustion noise index is developed and implemented in a vehicle. A number of injection parameters are controlled to meet the desired combustion noise index, and the combustion noise of a vehicle is improved up to 4.0 dB(A) in the specified frequency band.

Design and Implementation of a QoS Signaling Protocol for Multimedia Applications in Mobile Network Environments (이동망 환경에서 멀티미디어 응용을 위한 QoS 신호 프로토콜의 설계 및 구현)

  • Kim, Hong-Tae;Jeong, Seong-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.5
    • /
    • pp.673-684
    • /
    • 2008
  • In this paper, we propose a signaling protocol which can support QoS for multimedia applications continuously after handover of a mobile node in the network environment where IP-based wireless access networks co-exist. Since existing RSVP-based signaling protocols can cause the waste of network resources due to double reservation and do not provide fast resource reservation/release, they are not suitable for mobile networks. The proposed QoS signaling protocol can support QoS for multimedia applications using the fast reservation of necessary resources after handover and avoid the waste of resources by resolving the double reservation problem. This paper presents design and implementation architectures of the proposed signaling protocol and analyzes its performance via a physical testbed. Based on the analysis results, it was shown that the proposed protocol is able to support seamless QoS for multimedia applications.

  • PDF

Effects of Uncertainty in Graupel Terminal Velocity on Cloud Simulation (싸락눈 종단 속도의 불확실성이 구름 모의에 미치는 영향)

  • Lee, Hyunho;Baik, Jong-Jin
    • Atmosphere
    • /
    • v.26 no.3
    • /
    • pp.435-444
    • /
    • 2016
  • In spite of considerable progress in the recent decades, there still remain large uncertainties in numerical cloud models. In this study, effects of uncertainty in terminal velocity of graupel on cloud simulation are investigated. For this, a two-dimensional bin microphysics cloud model is employed, and deep convective clouds are simulated under idealized environmental conditions. In the sensitivity experiments, the terminal velocity of graupel is changed to twice and half the velocity in the control experiment. In the experiment with fast graupel terminal velocity, a large amount of graupel mass is present in the lower layer. On the other hand, in the experiment with slow graupel terminal velocity, almost all graupel mass remains in the upper layer. The graupel size distribution exhibits that as graupel terminal velocity increases, in the lower layer, the number of graupel particles increases and the peak radius in the graupel mass size distribution decreases. In the experiment with fast graupel terminal velocity, the vertical velocity is decreased mainly due to a decrease in riming that leads to a decrease in latent heat release and an increase in evaporative cooling via evaporation, sublimation, and melting that leads to more stable atmosphere. This decrease in vertical velocity causes graupel particles to fall toward the ground easier. By the changes in graupel terminal velocity, the accumulated surface precipitation amount differs up to about two times. This study reveals that the terminal velocity of graupel should be estimated more accurately than it is now.

A Near Real-Time Wind Tunnel System for Studying Evaporation of Chemical Agents(HD) (준실시간 소형 풍동 시스템을 이용한 화학작용제(HD) 증발특성 연구)

  • Kah, Dong-Ha;Jung, Hyunsook;Seo, Jiyun;Lee, Juno;Lee, Hae Wan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.135-140
    • /
    • 2019
  • Upon chemical agent release, it is of importance to study the characteristic persistence and evaporation of chemical agents from surfaces for the prediction of dispersion hazard. We have recently developed a fast and near real-time wind tunnel system proving the controlled environment(air flow, temperature, and humidity), continuously collects agent vapor and analyzes it. A thermal sorber/desorber is unnecessary to collect the vapor in the system we have developed. Instead, a tandem thermal sorber collects the vapor, which is then directly transferred to a fast gas chromatography(GC) for analysis. As a proof of concept, the evaporation of sulfur mustard agent(HD) was studied from glass, sand and concrete. The results were in an excellent agreement with those obtained from the conventional wind tunnel system.

Kinematical Analysis of Woman Javelin Throwing (창던지기 동작의 kinematic적 특성분석)

  • Lee, Jong-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.345-359
    • /
    • 2002
  • The purpose of the study was to provide the fundamental data to instruct athletes through the analysis athletes' movement in javelin. Three athletes in the level of national representative were participated in this study. The study analyzed kinematic variables(lead foot and releasing javelin) through 3-D analysis and obtained the following results. 1. During withdrawal, it is important to maintain of running horizontal velocity. 2. It was showed that throng average height was $84{\pm}3.3%$ and javelin adequative degree, Among the athletes, $S_2$ who had the best record was released the javelin with the fast velocity, but throw the javelin with the less releasing velocity. 3. $S_2$ released after lead foot were completely landed and therefore it is no problem in a kinematic aspect. However, $S_1$ angle was too small. it caused increase of release velocity to be prevented. 4. $S_2$ showing the best result indicated shorter in duration time. Generally, the shorter duration time in release phase showed the longer release distance. Especially $S_1$ and $S_3$ showing the worse result indicated the longer duration time in preparatory phase, causing the breakup of force. Therefore to improve the record, it should be decreased the duration time in preparatory phase. 5. Compared with $S_1$ and $S_3$, $S_2$ showing the best record indicated the higher velocity in center of mass, trunk, upper arm, lower arm and hand That is the higher velocity of upper arm at release leaded the better velocity transfer from upper arm to following lower arm and hand, these action should be considered to be helpful of better record. According to the above conclusion, when the athletic leaders cauch athletes, they should focus on maintaining knee angle, upper body and hip angle in a previous stage of release and throwing angle, throwing height, throwing velocity in a release stage.

Capping Treatment for the Reduction of Phosphorus Release from Contaminated Sediments of Lakes (호소퇴적물로부터 인 용출 저감을 위한 Capping 처리)

  • Kim, Seog-Ku;Lee, Mi-Kyung;Ahn, Jae-Hwan;Yun, Sang-Leen;Kim, So-Jung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.4
    • /
    • pp.438-446
    • /
    • 2006
  • A lab-scale batch test was conducted to develop capping materials to reduce the sediment phosphorus in the stagnant water zone of Gyeongancheon in Paldang Lake. The mean grain size(Mz) of sediment in the investigated area was 7.7 ${\phi}$, which is very fine, and the contents of organic carbon($C_{org}$) was 2.4%, which is very high. For the phosphorous release experiment to select the optimal capping material, sand layer, powder-gypsum($CaSO_4{\cdot}2H_2O$), granule-gypsum, complex layer(gypsum+sand) and the control were compared and evaluated in the 150 L reactor for 45 days. In case of the capping with the sand, it was found that the phosphorous from the sediment could be reduced by around 50%. However, it was found that this caused the reduction of the dissolved oxygen in the water column(by less than 3 mg/L) due to the resuspension of sediment and the organic matter decomposition that comes from the generation of $CH_4$ gas in the 1 cm of the sand layer. Therefore, it is likely that the sand layer has to be thickener in case of the sand capping. Powder-gypsum and granule-Gypsum reduced phosphorous release by more than 80%. However, the concentration of ${SO_4}^{2-}$ in the water column increased, making it difficult to apply it to the drinking water protection zone. We developed Fe-Gypsum and $SiO_2$-gypsum materials to reduce the solubility of ${SO_4}^{2-}$. Powder-Gypsum creates the interception film that does not have any aperture on the sediment layer when it is combined with the water. However phosphorous release caused by the generation of $CH_4$ gas may happen at a time when the gypsum layer has the crack. Capping through the complex layer(granule-Gypsum+sand(1 cm)) found to be suitable for the drinking water protection zone because it was effective to prevent phosphorus release. Moreover, this leads to the lower solubility from the concentration of ${SO_4}^{2-}$ into the water column than the powder-Gypsum and granule-Gypsum. The addition of gypsum($CaSO_4{\cdot}2H_2O$) into the sediment can reduce the progress of methanogensis because fast early diagenesis and sufficient supply of ${SO_4}^{2-}$ to the sediment, stimulate the SRB(sulfate reducing bacteria) highly.

Inhibition of Intimal Hyperplasia by Perivascular Delivery of Paclitaxel Using Poly(n-butylmethacrylate) or Poly(3-hydroxybutyrate-co-4-hydroxybutyrate) in Balloon-Injured Rat Carotid Arteries (쥐 경동맥 손상 모델에서 Poly(n-butylmethacrylate) 혹은 Poly(3-hydroxybutyrate-co-4-hydroxybutyrate)를 이용한 Paclitaxel 국소 전달 요법의 신생내막 형성 억제 효과)

  • Kwon, Jin-Sook;Lee, Ho-Yeon;Heo, Shin-Haeng;Park, Rho-Kwan;Shim, Tae-Jin;Kim, Yu-Kyug;Kim, Beom-Soo;Kim, Dong-Woon
    • Polymer(Korea)
    • /
    • v.32 no.3
    • /
    • pp.284-289
    • /
    • 2008
  • Polymer is a critical component of local drug delivery to prevent restenosis. This study tested whether poly(n-butylmethacrylate)(PBMA) and poly(3-hydroxybutyrate-co-4-hydroxybutyrate)(PHA) was candidates for this purpose. In vitro release of paclitaxel from PBMA and PHA loaded with 10% paclitaxel exhibited a triphasic release profile, with a fast initial and intermediate second phase followed by a slow release phase. Perivascular delivery of paclitaxel using these films inhibited neointimal hyperplasia in balloon-injured rat carotid arteries. The paclitaxel-loaded PBMA or PHA groups showed significant neointimal formation reductions versus the control groups (PBMA vs control: $0.03{\pm}0.02$ vs $0.10{\pm}0.01\;mm^2$, p<0.05; PHA vs control: $0.04{\pm}0.03$ vs $0.09{\pm}0.01\;mm^2$, p<0.05). This study suggests that PBMA and PHA could be good candidate polymers of local drug delivery to prevent restenosis. Perivascular delivery using these films represents a possible approach for prevention of restenosis. These can be candidate polymers for drug eluting stents.

Evaluation of Combustion Instability in a Model Gas Turbine Adopting Flame Transfer Function and Dynamic Mode Decomposition (화염 전달함수 및 DMD 기법을 이용한 모형 가스터빈의 연소불안정성 평가)

  • Son, Jinwoo;Sohn, Chae Hoon;Yoon, Jisu;Yoon, Youngbin
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • To evaluate the combustion instability of a gas turbine combustor, the DMD technique was applied. The mode frequency results for each fuel composition were compared with FFT(Fast Fourier Transform) results. The damping coefficient, which is a quantitative parameter for combustion instability, was evaluated for 5 experimental cases. The flame transfer function (FTF) was calculated in the most unstable test case. In deriving the FTF, gain and phase were calculated using DMD technique. As a result of the analysis of the OH radical perturbation of the DMD, the heat release fluctuation was the highest at 100 Hz, at which the highest value of gain is observed. The frequency of FFT and FTF were different. In order to clarify the reason for this, FTF for various resonance frequencies was performed and it shows that the pattern of gain was similar to FFT.

Recent Advances in Intranasal Drug Delivery (경비 약물전달체계의 최근의 진보)

  • Park, Gee-Bae;Lee, Yong-Suk;Lee, Kwang-Pyo
    • Journal of Pharmaceutical Investigation
    • /
    • v.22 no.2
    • /
    • pp.77-96
    • /
    • 1992
  • In recent years intranasal administration of drugs has received great attention as a convenient and efficent method of drug delivery because of its potential to improve the systemic effect of substances with a poor oral bioavailability. In addition to offering advantages such as rapid absorption, fast onset of action and avoiding the first -pass effect, it provides for delivery of drugs from very lipophilic drugs such as steroids to polar and hydrophilic drugs such as peptides and proteins. However, little is still known about the nature of various barriers existing in the nasal mucosae as well as mechanism by which these molecules are absorbed. This review article therefore intends to discuss nasal physiology, experimental methods and evaluation of absorption from the nasal cavity, factors influencing nasal absorption, mechanism of nasal absorption, approaches to improve the residence time and to obtain the sustained-release effect of intranasally administered drugs, promoters and mechanism for the enhancement of nasal absorption, Several examples for intranasal delivery of various systemically effective drugs will be reviewed and illustrated. Drug metabolism in the nasal mucosae and problems associated with intranasal administration of drugs will be also discussed.

  • PDF