• 제목/요약/키워드: failure pattern classification

검색결과 26건 처리시간 0.027초

Rotor Fault Detection of Induction Motors Using Stator Current Signals and Wavelet Analysis

  • Hyeon Bae;Kim, Youn-Tae;Lee, Sang-Hyuk;Kim, Sungshin;Wang, Bo-Hyeun
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2003년도 ISIS 2003
    • /
    • pp.539-542
    • /
    • 2003
  • A motor is the workhorse of our industry. The issues of preventive and condition-based maintenance, online monitoring, system fault detection, diagnosis, and prognosis are of increasing importance. Different internal motor faults (e.g., inter-turn short circuits, broken bearings, broken rotor bars) along with external motor faults (e.g., phase failure, mechanical overload, blocked rotor) are expected to happen sooner or later. This paper introduces the fault detection technique of induction motors based upon the stator current. The fault motors have rotor bar broken or rotor unbalance defect, respectively. The stator currents are measured by the current meters and stored by the time domain. The time domain is not suitable to represent the current signals, so the frequency domain is applied to display the signals. The Fourier Transformer is used for the conversion of the signal. After the conversion of the signals, the features of the signals have to be extracted by the signal processing methods like a wavelet analysis, a spectrum analysis, etc. The discovered features are entered to the pattern classification model such as a neural network model, a polynomial neural network, a fuzzy inference model, etc. This paper describes the fault detection results that use wavelet decomposition. The wavelet analysis is very useful method for the time and frequency domain each. Also it is powerful method to detect the features in the signals.

  • PDF

데이터마이닝을 이용한 반도체 FAB공정의 수율개선 및 예측 (Application of Data mining for improving and predicting yield in wafer fabrication system)

  • 백동현;한창희
    • 지능정보연구
    • /
    • 제9권1호
    • /
    • pp.157-177
    • /
    • 2003
  • 본 논문은 반도체 FAB공정의 수율개선 및 예측을 위해 데이터마이닝 기법을 적용한 사례를 소개한다. FAB 공정의 복잡성과 생산현장에서 수집되는 방대한 기술데이터로 인해 기존의 통계적 방법이나 엔지니어의 경험적 분석 방법만으로는 미처 파악하지 못하는 수율 저하 요인이 상당 수 존재한다. 본 논문은 먼저, FAB공정을 마친 웨이퍼에 불량 칩(chip)이 지리적으로 특정 위치에 집중적으로 발생하는 현상을 육안검사 대신 군집분석을 이용하여 데이터로부터 자동 판별할 수 있는 방법을 제안한다. 다음으로 연속패턴분석, 분류분석, RBF(Radial Base Function) 기법을 적용하여 수율 저하의 원인이 되는 문제 장비나 문제 파라미터를 신속, 정확하게 파악할 수 있도록 해 줄 뿐만 아니라 공정 진행 중인 제품의 미래 수율을 예측할 수 있도록 지원하는 방법을 제안한다. 또한 위 기법들을 반도체 FAB공정을 대상으로 국내 모 반도체 회사에서 정보시스템으로 구현한 Y2R-PLUS (Yield Rapid Ramp-up, Prediction, analysis & Up Support) 시스템을 소개한다.

  • PDF

Ceromer crown의 교합면 두께에 따른 압축 파절 강도의 비교 (The compressive fracture strength of ceromer crown by the difference of occlusal thickness)

  • 김지연;박하옥;양홍서
    • 구강회복응용과학지
    • /
    • 제18권3호
    • /
    • pp.205-215
    • /
    • 2002
  • This study investigated the compressive fracture strength of Targis ceromer crown by the difference of occlusal thickness on a maxillary first premolar. Control group was a castable IPS-Empress all-ceramic crown with occlusal thickness of 1.5 mm constructed by layered technique. Experimental groups were Targis crowns having different occlusal thicknesses of 1.0 mm, 1.5 mm, 2.0 mm, 2.5 mm, respectively. The classification of Targis group is T10, T15, T20, T25 and T15N (for no-thermocycling and occlusal thickness of 1.5mm). Ten samples were tested per each group. Except occlusal thickness, all dimension of metal die is same with axial inclination of $10^{\circ}$and marginal width 0.8mm chamfer. All crowns were cemented with Panavia F and thermocycled 1,000 times between $5^{\circ}$ and $55^{\circ}$ water bath with 10 sec dwelling time and 10 sec resting time. The compressive fracture strength was measured by universal testing machine. The results were as follows : 1. Fracture strength was increased as the occlusal thickness increased : compressive fracture strength of Group T10, T15, T20, T25 was $66.65{\pm}4.88kgf$, $75.04{\pm}3.01kgf$, $87.07{\pm}7.06kgf$ and $105.03{\pm}10.56kgf$, respectively. 2. When comparing material, Targis crown had higher fracture strength than IPS-Empress crown : the mean compressive strength of group T15 was $75.04{\pm}3.01kgf$ and the value of group Control was $37.66{\pm}4.28kgf$. 3. Fracture strength was decreased by thermocycling : the compressive fracture strength of T15 was $75.04{\pm}3.01kgf$, which is lower than $90.69{\pm}6.88kgf$ of group T15N. 4. The fracture line of crowns began at the loading point and extended along long axis of tooth. IPS-Empress showed adhesive failure pattern whereas Targis had adhesive and cohesive failure. In the SEM view, stress was distributed radially from loading point and the crack line was more prominent on Targis crown.

박근의 원위혈관경을 이용한 도서형 근피판술 (Musculocutaneus Island Flap Based on the Distal Vascular Pedicle of Gracilis Muscle)

  • 정덕환;이용욱;조창현
    • Archives of Reconstructive Microsurgery
    • /
    • 제6권1호
    • /
    • pp.96-102
    • /
    • 1997
  • The gracilis that is frequently used as a donor of free muscle trasfer is appropriate in the muscular shape and vascular position. This muscle is belonged to the second type of muscle group by the classification of the pattern of muscular nutrient vessel. The adductor branch or first perforating branch of deep femoral artery which supplies the proximal 1/3 of this muscle is a dominant one and this is used for the microscopic anastomosis of muscle or musculocutaneous flap. The minor vascular pedicles which enter the distal 1/3 of this of this muscle are branches of the superficial femoral artery and it is 0.5mm in diameter, 2cm in length with two venae comitantes. These minor pedicles supplies distal half of the gracilis muscle. This island musculocutaneous flap using distal vascular pedicle can be used to cover the defect of soft tissue around the distal femoral supra-condylar area, knee joint and proximal tibial condyle area which cause limitation of motion of knee joint, or in the cases that usual skin graft is impossible. The important operative procedure is as follows; The dissection is carried proximally and distally and the entire gracilis muscle including proximal and distal pedicle is completely dissected. After temporary blocking of the proximal vascular pedicle, the adequate muscle perfusion by the distal pedicle is identified and it is rotated to the recipient site around knee joint. The advantages of this procedure are simple, no need of microscopic vascular anastomoses and no significant functional loss of donor site. Especially in the cases of poor condition of the recipient vessel, this procedure can be used effectively. From 1991 to 1996, we performed 4 cases; complete survival of flap in 3 cases and partial survival of flap with partial necrosis in 1 case. This procedure is though to be useful in the small sized soft tissue defect of distal femoral supra-condylar area, knee joint and proximal tibial condylar area, especially in the defect of anterior aspect which expected to cause limitation of motion of knee joint due to scar contracture. But the problems of this procedure are the diameter of distal vascular pedicle is small and the location of distal vascular pedicle is not constant. To reduce the failure rate, identify the muscular perfusion of distal vascular pedicle after blocking the proximal pedicle, or strategic delay will be helpful.

  • PDF

프로펠러 편심추력변동이 축계안정성에 미치는 영향 연구 (Effect of Propeller Eccentric Thrust Change on Propusion Shafting System)

  • 이지웅;이재웅
    • 해양환경안전학회지
    • /
    • 제27권7호
    • /
    • pp.1082-1087
    • /
    • 2021
  • 프로펠러축은 프로펠러 하중 및 편심추력의 영향으로 인해 정적, 동적, 과도상태 각각 거동의 패턴이 달라져 선미관 후부베어링의 국부하중 변화를 일으킴으로써 선박 축계의 안정성에 큰 영향을 미치며, 결과적으로 축 지지 베어링의 손상위험을 증가시킨다. 이를 방지하기 위한 일련의 축계정렬연구는 선급강선규칙과 조선소 지침을 기반으로 준정적 상태에서 축과 선미관 베어링간의 상대적 경사각과 유막유지, 선체변형에 따른 영향평가를 최적화 하는데 중점을 두어 진행 되어왔다. 그러나 보다 진일보한 형태의 추진축계의 안정성을 보장하기 위해서는 조타장치의 전타시 발생하는 급격한 선미유동장 변화와 같은 과도동적상태변화 조건에서의 상세 연구가 필요하다. 이러한 관점 하에 본 연구에서는 50,000 DWT 중형 유조선을 대상으로 스트레인 게이지법과 변위센서을 이용하여 선박운전 중 대표적 과도상태인 좌현 전타시의 프로펠러 축 거동이 선미관 베어링에 미치는 영향을 교차검증한 결과, 프로펠러 편심추력변동이 선미관 베어링의 하중을 일시적으로 저감시켜 베어링 하중을 완화시키는 것을 확인하였다.

구인두암의 방사선치료 (Radiation Therapy for Carcinoma of the Oropharynx)

  • 박인규;김재철
    • Radiation Oncology Journal
    • /
    • 제14권2호
    • /
    • pp.95-103
    • /
    • 1996
  • 목적 : 구인두암으로 방사선치료를 받은 환자들을 대상으로 후향적 분석을 시행하여 생존율, 치료 실패 양상 및 생존율에 미치는 요인 등을 알아보고자 하였다. 방법 : 1985년 3월부터 1993년 6월까지 경북대학교병원 치료방사선과에서 구인두암으로 방사선치료를 시행한 53예의 환자를 대상으로 후향적 분석을 시행하였다. 환자의 연령은 31세에서 73세로 중간값은 54세였으며 남자 47예 여자 6예였다. 조직학적으로 편평세포암종이 42예, 미분화암종 이 10예, 선양 낭성암종이 1예였다. 병기별 분포는 I기 2예, II기 12예, III기 12예, IV기 27예이었다. T1 7예, T2 28예, t3 10예, T4 7예, T병기가 불명확한 경우가 1예이었고, N0 17예, Nl 13예, N2 21예, N3 2예였다. 원발병소는 편도 36예, 설기저부 12예, 그리고 연구개 5예였다. 방사선 단독치료가 25예, 유도화학요법 및 방사선치료 병용요법이 28예였다. 유도화학요법은 CF (cisplatln, 5-fluorouracil) 또는 CVB (cisplatin, vincristine, bleomycin) 약제로 1-3회 시행하였다 방사선치료는 6MV X선 및 8-10MeV 전자선을 이용하였고 방사선 치료선량은 일일 180-200 cGy씩 총 4500-7740 cGy로 중간값은 7100 cGy였다. 환자의 추적기간은 4개월에서 99개월로 중간추적기간이 21개월이었다. 결과 : 방사선치료 후 37예 ($69.8\%$)에서 완전관해를 보였고 16예 ($30.2\%$) 에서 부분관해를 보였다. 전체 환자에서 2년생존율은 $47\%$, 3년생존율은 $42\%$였고 중앙생존기간은 23개월이었다. 치료에 대한 반응 (p=0.004) 및 전체병기가 (p=0.02) 통계적으로 의미있게 생존율에 영향을 미치는 것으로 나타났다. 2년 무병생존율은 $45.5\%$였고 T 병기 (p=0.03), N 병기 (p=0.04) 및 전체병기가 (p=0.04) 의미있게 무병생존을에 영향을 미치는 것으로 나타났다. 환자의 나이, 성별, 조직학적 소견, 원발병소, 방사선량 및 화학요법과의 병합치료는 무병생존율에 영향을 주지 않았다. 방사선치료 후 완전관해를 보인 36예 중 추적조사가 가능했던 32예에서의 치료 실패양상은 국소재발이 8예, 원격전이가 4예로 주된 치료 실패 원인은 국소재발이었다. 결론 : 본 연구에서는 N 병기, 7 병기 및 전체병기가 무병 생존율에 영향을 미치는 인자로 나타났으며, 국소재발이 주된 실패 요인이 되고 있어 국소완치를 위한 노력이 절실히 요구된다. 현재까지 구인두암의 치료는 방사선 단독치료가 가장 효과적인 치료방법으로 여겨지며 화학요법은 좀더 많은 비교 대조군 연구를 통해서만 역할을 평가할 수 있을 것으로 사료된다.

  • PDF