• Title/Summary/Keyword: failure path

Search Result 353, Processing Time 0.028 seconds

Study on a System Reliability Calculation Method Using Failure Enumeration of Reliability Path (신뢰도 경로의 고장열거를 이용한 시스템 신뢰도 계산방법 연구)

  • Lee, Jang-Il;Park, Kee-Jun;Chun, Hwan-Kyu;Jeong, Choong-Min;Shin, Dong-Jun;Suh, Myung-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.6
    • /
    • pp.629-633
    • /
    • 2011
  • Recently, systems such as aircraft, trains and ships have become larger more complex. Therefore, the reliability calculation of these systems is more difficult. This paper presents a reliability calculation algorithm for a complex system with a solution that is difficult to analyze. When the system has a very complex structure, it is very difficult to find an analytical solution. In this case, we can assess system reliability using the failure enumeration method of the reliability path. In this research, we represent the reliability block diagram by an adjacent matrix and define the reliability path. We can find any system status by the failure enumeration of the reliability path, and thus we can calculate any kind of system reliability through this process. This result can be applied to RCM (Reliability-Centered Maintenance) and reliability information-management systems, in which the system reliability is composed of the reliabilities of individual parts.

Structural Performance Improvement of Composite Plates By Using Curvilinear Fiber Format (곡선섬유를 이용한 복합재료 평판의 구조적 성능 향상)

  • 이호영
    • Composites Research
    • /
    • v.12 no.6
    • /
    • pp.31-42
    • /
    • 1999
  • In aerospace industry, the improvement of structural performance of fight structure without increasing weight has great advantage. In this study. an innovative design method to increase the buckling load and tension failure load at the same time without increasing the weight of composite plates was investigated. By using the curvilinear fiber format a method to increase the buckling load and tension failure load simultaneously was investigated for composite plates with central hole with finite element method. It was investigated how much gain can be obtained with curvilinear fiber format for the plates with different hole size and different stacking sequence. And, for the cases studied, the failure mechanism was also investigated. For the manufacturing of the curvilinear fiber format, smoothly and continuously changing fiber path is necessary. In this study, a simple method to find the smoothly changing fiber path by using the fiber angles obtained with finite element method was presented.

  • PDF

Forming Limit Prediction in Tube Hydroforming Processes by using the FEM and ELSD (유한요소법과 FLSD를 이용한 관재 하이드로포밍 공정에서의 성형 한계 예측)

  • Kim S. W.;Kim J.;Lee J. H.;Kang B. S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.92-96
    • /
    • 2005
  • Among the failure modes which can be occurred in tube hydroforming such as wrinkling, bursting or buckling, the bursting by local instability under excessive tensile stresses is irrecoverable phenomenon. Thus, the accurate prediction of bursting condition plays an important role in producing the successfully hydroformed part without any defects. As the classical forming limit criteria, strain-based forming limit diagram has widely used to predict the failure in sheet metal forming. However, it is known that the FLD is extremely dependant on strain path throughout the forming process. Furthermore, the path-dependent limitation of FLD makes the application to hydroforming process, where strain path is no longer linear throughout forming process, more careful. In this work, stress-based forming limit diagram (FLSD), which is strain path-independent and more general, was applied to prediction of forming limit in tube hydroforming. Combined with the analytical FLSD determined from plastic instability theory, finite element analyses were carried out to find out Ihe state of stresses during hydroforming operation, and then FLSD is utilized as forming limit criterion. In addition, the approach is verified with a series of bulge tests in view of bursting pressure and shows a good agreement. Consequently, it is shown that the approach proposed in this paper will provide a feasible method to satisfy the increasing practical demands for judging the farming severity in hydroforming processes.

  • PDF

A Path Restoration Method Independent of Failure Location in All-Optical Networks (전광 통신망에서 장애 위치에 독립적인 경로 복구 방법)

  • 이명문;유진태;김용범;박진우
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11C
    • /
    • pp.85-93
    • /
    • 2001
  • In this paper, a path restoration method independent of failure location in all-optical networks is proposed and its wavelength requirements are calculated. In the proposed method, since a single backup wavelength is used for any link failure, a node can consist of only fixed wavelength transmitters, resulting in the levels node cost. Hence, restoration process can be triggered just after the failure detection, if combined with edge-disjoint path restoration method. This feature and the parallel cross-connection message transfer technique proposed in this paper make the restoration process faster. Also, it is shown the wavelength requirements in the proposed method are similar to the ones in the method using tunable backup wavelength, resulting in little increment for transmission cost.

  • PDF

Application of the compressive-force path concept in the design of reinforced concrete indeterminate structures: A pilot study

  • Seraj, Salek M.;Kotsovos, Michael D.;Pavlovic, Milija N.
    • Structural Engineering and Mechanics
    • /
    • v.3 no.5
    • /
    • pp.475-495
    • /
    • 1995
  • In the past, physical models have been proposed, in compliance with the concept of the compressive-force path, for the realistic design of various statically determinate structural concrete members. The present work extends these models so as to encompass indeterminate RC structural forms. Pilot tests conducted on continuous beams and fixed-ended portal frames have revealed that designing such members to present-day concepts may lead to brittle types of failure. On the other hand, similar members designed on the basis of the proposed physical models attained very ductile failures. It appears that, unlike current design approaches, the compressive-force path concept is capable of identifying those areas where failure is most likely to be triggered, and ensures better load redistribution, thus improving ductility. The beneficial effect of proper detailing at the point of contraflexure in an indeterminate RC member is to be noted.

FLB Event Analysis with regard to the Fuel Failure

  • Baek, Seung-Su;Lee, Byung-Il;Lee, Gyu-Cheon;Kim, Hee-Cheol;Lee, Sang-Keun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.622-627
    • /
    • 1996
  • Detailed analysis of Feedwater Line Break (FLB) event for the fuel failure point of view are lack because the event was characterized as the increase in reactor coolant system (RCS) pressure. Up to now, the potential of the rapid system heatup case has been emphasized and comprehensively studied. The cooldown effects of FLB event is considered to be bounded by the Steam Line Break (SLB) event since the cooldown effect of SLB event is larger than that of the FLB event. This analysis provides a new possible path which can cause the fuel failure. The new path means that the fuel failure can occur under the heatup scenario because the Pressurizer Safety Valves (PSVs) open before the reactor trips. The 1000 MWe typical C-E plant FLB event assuming Loss of Offsite Power (LOOP) at the turbine trip has been analyzed as an example and the results show less than 1% of the fuel failure. The result is well within the acceptance criteria. In addition to that, a study was accomplished to prevent the fuel failure for the heatup scenario case as an example. It is found that giving the proper pressure gap between High Pressurizer Pressure Trip (HPPT) analysis setpoint and the minimum PSV opening pressure could prevent the fuel failure.

  • PDF

Study on failure mechanism of multi-storeyed reinforced concrete framed structures

  • Ahmed, Irfan;Sheikh, Tariq Ahmad;Gajalakshmi, P.;Revathy, J.
    • Advances in Computational Design
    • /
    • v.6 no.1
    • /
    • pp.1-13
    • /
    • 2021
  • Failure of a Multi-storeyed reinforced concrete framed structure occurs when a primary vertical structural component is isolated or made fragile, due to artificial or natural hazards. Load carried by vertical component (column) is transferred to neighbouring columns in the structure, if the neighbouring column is incompetent of holding the extra load, this leads to the progressive failure of neighbouring members and finally to the failure of partial or whole structure. The collapsing system frequently seeks alternative load path in order to stay alive. One of the imperative features of collapse is that the final damage is not relative to the initial damage. In this paper, the effect on the column and beam adjacent to statically removed vertical element in terms of axial force, shear force and bending moment is investigated. Using Alternate load path method, numerical modelling of two dimensional one bay, two bay with variation in storey heights are analysed with FE model in order to obtain better understanding of failure mechanism of multi-storeyed reinforced concrete framed structure. The results indicate that the corner column is more susceptible to progressive collapse when compared to middle column, using this simplified methodology one can easily predict how the structure can be made to stay alive in case of sudden failure of any horizontal or vertical structural element before designing.

The Effect of Photoluminescent Exit Path Markings in Evacuation from Buildings (건축물 내에서 축광유도타일이 피난에 미치는 영향)

  • Hur, Man-Sung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.3 s.18
    • /
    • pp.67-72
    • /
    • 2005
  • This study is intended to examine the effect of photoluminescent exit path markings in the event of failure of both the power and back-up power to the lighting and illuminated exit sign. To achieve the purpose, the test house was exhibited in Fire EXPO '05. 520 visitors were examined from May 26-29, 2005. The results of this study are as follows; The evacuation from buildings in dark conditions showed that 70% of men and 72% of women were crawled along the wall. Meanwhile, 88% of men and 83% of women were evacuated with ordinary walking in photoluminescent exit path markings. The photoluminescent exit path markings located on public buildings floors will aid in evacuation from buildings in the event of failure of the power to the lightings and illuminated exit signs.

Machine Learning Based Neighbor Path Selection Model in a Communication Network

  • Lee, Yong-Jin
    • International journal of advanced smart convergence
    • /
    • v.10 no.1
    • /
    • pp.56-61
    • /
    • 2021
  • Neighbor path selection is to pre-select alternate routes in case geographically correlated failures occur simultaneously on the communication network. Conventional heuristic-based algorithms no longer improve solutions because they cannot sufficiently utilize historical failure information. We present a novel solution model for neighbor path selection by using machine learning technique. Our proposed machine learning neighbor path selection (ML-NPS) model is composed of five modules- random graph generation, data set creation, machine learning modeling, neighbor path prediction, and path information acquisition. It is implemented by Python with Keras on Tensorflow and executed on the tiny computer, Raspberry PI 4B. Performance evaluations via numerical simulation show that the neighbor path communication success probability of our model is better than that of the conventional heuristic by 26% on the average.

Workflow Interruptions and Failed Action Regulation in Surgery Personnel

  • Elfering, Achim;Nutzi, Marina;Koch, Patricia;Baur, Heiner
    • Safety and Health at Work
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Background: Workflow interruptions during surgery may cause a threat to patient's safety. Workflow interruptions were tested to predict failure in action regulation that in turn predicts near-accidents in surgery and related health care. Methods: One-hundred-and-thirty-three theater nurses and physicians from eight Swiss hospitals participated in a cross-sectional questionnaire survey. The study participation rate was 43%. Results: Structural equation modeling confirmed an indirect path from workflow interruptions through cognitive failure in action regulation on near-accidents (p < 0.05). The indirect path was stronger for workflow interruptions by malfunctions and task organizational blockages compared with workflow interruptions that were caused by persons. The indirect path remained meaningful when individual differences in conscientiousness and compliance with safety regulations were controlled. Conclusion: Task interruptions caused by malfunction and organizational constraints are likely to trigger errors in surgery. Work redesign is recommended to reduce workflow interruptions by malfunction and regulatory constraints.