• Title/Summary/Keyword: facility standard

Search Result 917, Processing Time 0.028 seconds

Actual state Analysis for Residential space of Elderly Nursing Facility (노인요양시설의 거주공간에 대한 실태조사 분석)

  • Jang, Hye-Won;Kim, Dae-Hee;Hwang, Eun-Kyuong
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.166-170
    • /
    • 2008
  • The elder population is growing rapidly in Korea nowadays. Therefore, a demand for adaptable installation standard of residential space for the elderly is increasing with growth of the elder population. This study analyzed actual state by interviewing manager, surveying actual measurement and using draft of Elderly nursing facility which is for senile patients. As a result of the survey for size and facilities, facilities for elderly safety, accommodation per a person and room size per a person are below to standard. Therefore, establishing adaptable design standard is needed which is to make safe and fresh living environment for the elderly.

  • PDF

An Institutional Improving Standards for Water Reclamation/Reuse(WRR) System Establishment to Buildings (건축물의 중수도 설치기준에 대한 제도적 개선방안)

  • Kong, Young Hyo
    • KIEAE Journal
    • /
    • v.6 no.3
    • /
    • pp.43-48
    • /
    • 2006
  • This paper aims to suggest ways of institutionally improving standards that must be applied when installing Water Reclamation/Reuse (WRR) system based on efficiency analysis. Currently, the standard for WRR system establishment requires that the system should treat more than 10% of used water in the building of over $60,000m^2$ in total area of all floors, but our research has found that it would be more effective to change the standard to $150-m^3-per-day$ reclaimed water or the total area of all floors of $30,000m^2$ ($50,000m^2$ in the case of an office building). In other words, what this paper suggests is not a one-size-fits-all standard based on the total area of all floors, but a reasonable and flexible standard that takes into account efficiency and a unit water usage according to a building's purpose. Furthermore, this paper recommends a new WRR standard that can be applied to large-scale land development for housinglots, like the New Town. The recommendation is based on the economic analysis that the WRR system will ensure efficiency only if the amount of reclaimed water is over 4,000 tons per day, which corresponds to 4 millions square meters of housinglots. Regarding the size of the established facility, this paper suggests changing the standard, which is now set at over 10% of water usage, to what is relative to the total amount of use of reclaimed water in order to ensure efficiency and promote use of reclaimed water. In addition, this paper proposes that governmental support should be offered not only to facility owners, who are recipients at present, but also to facility builders. By doing so, those who donate a facility to the government, central or local, after building it, can be provided with substantial aid. Therefore, the application of the institutional improvement suggested in this paper is expected to create environment-friendly living conditions and boost the quality of life by encouraging people to secure water resources efficiently in buildings, and in a wider range, in cities.

Korean Standard Draft of the Laboratory Method of Measuring the Airborne Sound Insulation of a Suspended Ceiling (매단 천장의 실간 공기전달음 차단성능 측정방법의 KS규격화 방안)

  • Yang, Kwan-seop;Lee, Keun-hee;Kim, Sun-woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.393.1-393
    • /
    • 2002
  • Offices and other multipurpose buildings commonly have suspended ceilings installed over room dividing wall. But Korean Standards don't include any code on test methods and test facility of the suspended ceiling system. Therefore, test methods and test facility from ISO and ASTM have been used for evaluating sound performance in domestic so far. In this study, Korean Standards draft on test methods and test facility of suspended ceiling system and materials is proposed on the basis of ISO and ASTM.

  • PDF

A Study on Attributes of Elderly Housing Selection by The Middle and The Aged (중년층과 노년층의 노인시설주거 선택 속성에 관한 연구)

  • 신영숙
    • Journal of the Korean housing association
    • /
    • v.15 no.2
    • /
    • pp.43-54
    • /
    • 2004
  • The purpose of this study is to identify the elderly housing farcility design preference by comparing two groups, the present residents living in elderly housing facility and the middle aged. The latter has more housing experiences and more design oriented standard of selecting house for quality of living, while the aged are oriented more in economy and investment. It is identified that both group preferred living in elderly housing facility best to any other elderly housing type, including "aging in place." The aged are not yet very concerned about physically homelike design features, but when the middle aged need the elderly housing, it is recommended that more variety and amenity in its type, location, plan and design features. The idealistic facility planning and management system were suggested.

Development of B-Value Based GBAS Ground Facility Error Standard Deviation Model and Verification (B-Value를 이용한 GBAS 지상국 오차 표준편차 모델 개발 및 성능 평가)

  • Jun, Hyang-Sig;Ahn, Jong-Sun;Lee, Young-Jae;Choi, Young-Kiu;Sung, Sang-Kyung;Yeom, Chan-Hong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.12
    • /
    • pp.1232-1237
    • /
    • 2009
  • The ICAO and FAA are developing and verifying of GBAS for civil aircraft landing and take-off. The guarantee of aircraft integrity issue is the important part of GBAS. To guarantee integrity, the GBAS ground facility broadcasts various informations to aircraft. The informations are related to the estimated accuracy of each pseudorange correction and the estimated error terms, for example B-value and standard deviation of the ground facility error. These parameters are used to calculate position error (estimated value of the user). If estimated position errors don't satisfy requirements, aircraft use alternate navigation means. In this paper, GBAS reference stations's real data, which operated by KARI (Korea Aerospace Research Institute) in Jeju international airport, are used to development of new ground facility error standard deviation model. We verify improvement of GBAS availability, with respected to vertical protection level, using B-value based a new ground facility error standard deviation model and a sigma inflation factor.

Performance of the RI Exhaust Filter at Chosun University Cyclotron Facility and 18F Emission Reduction (조선대학교 사이클로트론 시설의 RI 배기필터 성능평가 및 18F 배출저감 연구)

  • Jeong, Cheol-Ki;Jang, Han;Lee, Goung-Jin
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • Recently, the number of PET cyclotrons has increased in Korea. A cyclotron mainly produces $^{18}F$, which is used for the production of [$^{18}F$]FDG, a cancer diagnostic radiopharmaceutical. For radiation protection, the discharge control standard under the Nuclear Safety Act limits the radioactive concentration of $^{18}F$ in the exhaust discharged from a nuclear power utilization facility to below $2,000Bq\;m^{-3}$. However, the radioactive concentration of $^{18}F$ discharged during [$^{18}F$]FDG production at the cyclotron facility at Chosun University is maintained at about $1,500Bq\;m^{-3}$ on average, which is 75% of the concentration limit of the discharge control standard, and temporarily exceeds the standard as per the real-time monitoring results. This study evaluated the performance of the exhaust filter unit of the cyclotron facility at Chosun University by assessing the concentration of $^{18}F$ in the exhaust, and an experiment was conducted on the discharge reduction, where $^{18}F$ is discharged without reacting with the FDG precursors during [$^{18}F$]FDG synthesis and is immediately captured by the [$^{18}F$]FDG automatic synthesis unit. Based on the performance evaluation results of the exhaust filter at the cyclotron facility of Chosun University, the measured capture efficiency before and after the filter was found to be 92%. Furthermore, the results of the discharge reduction experiment, where the exhaust $^{18}F$ was immediately captured by the [$^{18}F$]FDG synthesizer, showed a very satisfactory 94.3% reduction in the concentration of discharge compared to the existing discharge concentration.

A Study on the Planning Improvement of A Hall for the Aged in Apartment Housing -Focusing on apartments of Joong-dong, Bucheon city- (공동주택 경로당의 계획적 개선 방향에 관한 연구 -부천시 중동 소재 아파트를 중심으로-)

  • Ha, Seung-Beom
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.9 no.3
    • /
    • pp.25-35
    • /
    • 2009
  • This study is planning improvement of welfare facilities about the hall for the aged in apartment housing. An apartment house, famous residential type in Korea, put an important value on its convenience and economical efficiency of furniture arrangement by maximizing floor space index. In this regard, leisure usage of house was not carefully considered for the aged people. To redefine the efficiency of welfare facilities, research mainly deals with analysis of realistic needs for the aged through the spot survey and interview. The main purpose of this study is to enhance the quality of welfare facilities and propose the improved welfare facilities for the aged people. Through the research, conclusions are as followed First, Facility standard and provisions of the law should be revised for considering population growth of the aged people. Second, there are 4 plan types in the hall for the aged. Contrary to our expectation, diversity of program was not found however various program planning is needed for considering its different types of plan. Third, according to regulation, space restriction is based on the number of households. Therefore, room and space standard does not depend on the number of people. From now on, in order to improve quality of welfare facilities of the aged, revision of laws and overall facility standard should be implemented in advance.

  • PDF

Development of Common Data Standard for Airports Facilities based on Building Information Modeling (BIM) (공항시설물에 대한 BIM 기반의 공통 데이터 표준 구축 방안)

  • Jung, Euisoo;Kim, Kee-Woong;Choi, Youn-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.29 no.3
    • /
    • pp.100-110
    • /
    • 2021
  • Building Information Modeling(BIM) technology continues to develop and is now being applied to infrastructure facilities. As smart technology based on BIM is applied to the construction industry, the construction of the same data in a common environment is considered to be a very important step in various applications. This study was conducted on methods to establish an open BIM-based airport facility information common data environment. Therefore, this study develops the element technology to establish a common data environment for the integrated management of airport facility information, and aims to standardize data in the common data environment among various technologies and applications. In order to achieve the aim, in this study, the required technologies were derived by examining the common data environment and examining the civil engineering facility field and the case of integrated airport facility management. Through this, standards and development for information standard framework, information requirement level, BIM guidebook, and BIM library were developed in connection with national and higher standards. Through these standards, it is expected that the integrated management of various airport facilities will be efficiently carried out through a standard data platform in the future.

Contribution of thermal-hydraulic validation tests to the standard design approval of SMART

  • Park, Hyun-Sik;Kwon, Tae-Soon;Moon, Sang-Ki;Cho, Seok;Euh, Dong-Jin;Yi, Sung-Jae
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1537-1546
    • /
    • 2017
  • Many thermal-hydraulic tests have been conducted at the Korea Atomic Energy Research Institute for verification of the SMART (System-integrated Modular Advanced ReacTor) design, the standard design approval of which was issued by the Korean regulatory body. In this paper, the contributions of these tests to the standard design approval of SMART are discussed. First, an integral effect test facility named VISTA-ITL (Experimental Verification by Integral Simulation of Transients and Accidents-Integral Test Loop) has been utilized to assess the TASS/SMR-S (Transient and Set-point Simulation/Small and Medium) safety analysis code and confirm its conservatism, to support standard design approval, and to construct a database for the SMART design optimization. In addition, many separate effect tests have been performed. The reactor internal flow test has been conducted using the SCOP (SMART COre flow distribution and Pressure drop test) facility to evaluate the reactor internal flow and pressure distributions. An ECC (Emergency Core Coolant) performance test has been carried out using the SWAT (SMART ECC Water Asymmetric Two-phase choking test) facility to evaluate the safety injection performance and to validate the thermal-hydraulic model used in the safety analysis code. The Freon CHF (Critical Heat Flux) test has been performed using the FTHEL (Freon Thermal Hydraulic Experimental Loop) facility to construct a database from the $5{\times}5$ rod bundle Freon CHF tests and to evaluate the DNBR (Departure from Nucleate Boiling Ratio) model in the safety analysis and core design codes. These test results were used for standard design approval of SMART to verify its design bases, design tools, and analysis methodology.

Quality Management (QM) Standard Issues in FM - Based on Guidance on quality in European FM Standard

  • Lee, So Young;Jang, Yon Hwa;Lee, Myoung Sik
    • Architectural research
    • /
    • v.18 no.1
    • /
    • pp.21-29
    • /
    • 2016
  • Importance of FM has rapidly increased because of its growing business. However, due to lack of clarity and identity of FM in professional areas, standardization of FM became to be imperative in such a rapidly changing global business environment. Facility services are defined as the provision of support the primary activities of an organization, delivered by an internal or external provider. Majority of FM activities are services related to 'space and infrastructure' and 'people and organization' (CEN, 2011). The purpose of this study is to investigate definitions and characteristics of FM from both globally and domestic environment, by comparison with international or national standards, to identify quality management in FM and service characteristics of FM, to investigate the differences in service level elaboration in FM, and to suggest standard issues of quality management in FM service quality. This study examines contents of the European Standards in FM, Part 3 'Guidance on quality in Facility Management, especially for the process of QM standardized by CEN (2011) and explores undefined issues such as service level, measurement metrics according to service characteristics of FM. The European FM Standard guides the common process of QM in terms of requirements specification, service level elaboration, measurement metrics development although it does not specifically address various service levels, specific performance metrics and indicators.