• Title/Summary/Keyword: facility safety management

Search Result 706, Processing Time 0.029 seconds

Development of E-PAD based condition evaluation system for facility safety inspection (시설물 안전점검을 위한 E-PAD 기반 상태평가 시스템 개발)

  • Jung, Hae-Yong;Lee, Heung-Su;Yi, Jong-Hwa;Kim, Young-Seok;Park, Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.1-7
    • /
    • 2019
  • As a unify operational processes of the safety inspection for major national facilities, it is expected that the efficiency and professionalism of the project will be enhanced. Also it is being emphasized that the importance of visual inspection that initially find physical and functional defects in facilities. In this study, we developed an E-PAD-based condition evaluation system to check the safety of the facility to overcome the problems and limitations of the existing inspection method. This system consists of introduction, work list, visual inspection, defect table and so on. It is possible to download the inspection drawings at the site and input the damage information to the drawings and check the evaluation grade. In order to verify the E-PAD based condition evaluation system, the inspection data of 10 sample bridges were inputted into the system and the evaluation results were compared. As a result, it was confirmed that the safety grade calculated from the system and the existing safety grade are the same. The feasibility analysis of the AHP method also showed that the function increased by 10%, cost by 36%, and value by 30% compared to the existing method. Therefore, it is expected to contribute to systematic data and information analysis system for improvement of facility management.

The Knowledge and Confidence in Performance on Patient Safety among Health-Related Majors : Convergent Approach (보건계열 학생의 환자안전 지식 및 수행 자신감 : 융복합적 접근)

  • Lee, Mi Hyang;Park, Jung Hee;Bae, Seok Hwan
    • Journal of Digital Convergence
    • /
    • v.17 no.1
    • /
    • pp.219-227
    • /
    • 2019
  • The purpose of this study was to investigate the knowledge on patient safety and performance confidence for the subject of health-related major students. Participants were 349 Health-related majors. Data were analyzed using SPSS 21.0. According to the study results, correct answer rate for patients' knowledge on safety was 65.7% in average. Average point of performance confidence was $7.11{\pm}1.74$. Considering in terms of question, patient identification was high, while effective communication was shown to be low. Patient identification, communication, surgery procedure, fall, patient's safety accident report as the lower domain for patients' knowledge on safety and performance confidence had a positive correlation, while knowledge and infection management, facility environment had a negative correlation for health-related major students, development of patients' safety education program is needed to enhance importance of patients' safety before clinical practice and to allow implementation of safe clinical practice.

A Study on Improving Facility Standards for School Safety Accident Prevention - Focus on Schools in Gyeonggi-do - (학교생활 안전사고 예방을 위한 시설 개선 방향에 관한 연구 - 경기도 초·중·고등학교를 중심으로 -)

  • Yang, Hyeong-Mo;Lee, Jae-Rim
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.23 no.1
    • /
    • pp.33-42
    • /
    • 2016
  • The majority of school accidents occur due to negligence caused by the student. And there are many accidents caused by inadequate facilities and poor. In order to improve the facilities, a lot of improvement in student life facilities will be preceded conscious about the sense of safety, than the budget. If schools member have a risk recognition through safety training and ongoing attention of all experience-oriented, the occurrence of accidents is significantly reduced. it is needed continuous attentions and careful efforts to improve school facilities. The results were as follows. First, check for accident prevention and the improvement of the school facilities should be made immediately. Second, we need to redefine the standards facilities for school safety accident prevention. Third, the management program is needed to prevented school accident. Fourth, the Hazard identification and risk assessment training is needed.

Security Problem of National Major Facility's Parking Lot and its Improvement Method -Focused on Doonchi(Waterside) Parking Lot of National (국가중요시설의 주차장 보안의 문제점과 개선방안: 국회둔치주차장을 중심으로)

  • Lee, Sang-Hun;Lee, Sang-Yeol
    • Korean Security Journal
    • /
    • no.50
    • /
    • pp.61-87
    • /
    • 2017
  • National Assembly is a constitutional institution that is required to first consult the will of the people and it should do its effort continuously so that security of citizens using parking lot would be enhanced at the same time while improving parking service in order to increase customer satisfaction of the people. Under this recognition, in this study, Doonchi parking lot of National Assembly under consigned management was first reviewed in a perspective of criminal prevention through environmental design(CPTED) and particularly, fence installation and reinforcement work for securing 'territoriality' and operation of all round shooting camera and installation of No-trespassing warning board at entrance were suggested. Second, it was recommended to change independent control system in which CCTV security system of National Assembly Doonchi parking lot is operated separately from National Assembly safety situation room and integrate it with National Assembly safety situation room(revised to double safety system) and performance of CCTV camera was made to be increased to over 2m. In addition, video recording mode was converted to NVR mode for application to IP camera in the future and in order to avoid dead zone of security monitoring area and based on site inspection result, addition 3 places of newly installing CCTV were indicated. Third, it was recommended to introduce parking fare billing and management system through unmanned equipment in parking lot management and operation.(specialized management of professional parking service provider was reviewed). By doing so, risk of cash handling by charging personnel was removed by reducing current 7 working personnel to 3 and particularly, by converting parking lot management mode being operated temporarily from 9 A.M. to 9 P.M. at present to 24 hours operation mode and providing more specialized parking service, citizens visiting National Assembly were provided with convenience and image of National Assembly was also enhanced. This study was carried out in parallel with various literature and case studies, including data from the Office of the Defense Protection in the National Assembly.

  • PDF

Corrosion Evaluation for Advanced Fuel Cycle Facilities (선진 핵연료주기 시설(AFC)의 부식건전성 조사, 분석)

  • Hwang, Seong Sik
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.213-217
    • /
    • 2012
  • The amount of spent fuel from nuclear power plants has been increasing. An effective management plan of the spent fuel becomes a critical issue, because the storage capacity of each plant will reach its storage limit in a few years. The volume of high toxic spent fuel can be reduced through a fuel processing. Advanced Fuel Cycle (AFC) system is considered to be one of the options to reduce the toxicity and volume of the spent fuel. It is necessary to set up a test facility to demonstrate the feasibility of the process at the engineering scale. The objective of the work is a development of the safety evaluation technology for the AFC system. The evaluation technology of the AFC structural integrity and processes were surveyed and reviewed. Key evaluation parameters for the main processes such as electrolytic reduction, electrorefining, and electrowinning were obtained. The survey results may be used for the establishment of the AFC regulatory licensing procedure. The establishment of the licensing criteria minimizes the trials and errors of the AFC facility design. Issues taken from the survey on the regulatory procedure and design safety features for the AFC facility provide a chance to resolve potential issues in advance.

Development of Customized Hygiene Management Manual for Bucheon Children Meal Supply Organization and Evaluation of Effects (부천시 어린이 급식소 맞춤형 위생 관리 매뉴얼 개발 및 효과 평가)

  • Cho, Shin-Ho;Bae, Mi-Ae;Lee, Hyun-Sun;Park, So-Hyun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.24 no.2
    • /
    • pp.275-282
    • /
    • 2014
  • This study developed Bucheon customized children meal hygiene central control point (CCP) to promote practical hygiene and safety management in a children meal supply organization in Bucheon. Education was administered to 54 organizations using the developed CCP, and the study evaluated kitchen hygiene management improvement effects. When the effects of hygiene education in eight categories (CCP 1~8) were examined, total scores increased by 9.31 from $22.36{\pm}5.039$ before education to $31.67{\pm}3.262$ with a statistically significant difference (p<0.001). After CCP education, personal hygiene management, food material management, cooking management, serving management, facility and equipment management improved significantly. The result demonstrates that CCP education was effective for kitchen hygiene management. Using CCP education, overall CCP education items were significantly improved, but there was almost no significant increase in the non-relevant item of CCP education. As there was an average difference in the non-relevant item of CCP education after follow-up evaluation, CCP education had an overall effect on hygiene and safety improvement. Based on the above result, the effect could be potentiated if CCP is complemented, if a systematic hygiene management manual is developed for the nationwide children meal supply organization, and if CCP education media is continually developed along with education.

Preliminary Inspection Prediction Model to select the on-Site Inspected Foreign Food Facility using Multiple Correspondence Analysis (차원축소를 활용한 해외제조업체 대상 사전점검 예측 모형에 관한 연구)

  • Hae Jin Park;Jae Suk Choi;Sang Goo Cho
    • Journal of Intelligence and Information Systems
    • /
    • v.29 no.1
    • /
    • pp.121-142
    • /
    • 2023
  • As the number and weight of imported food are steadily increasing, safety management of imported food to prevent food safety accidents is becoming more important. The Ministry of Food and Drug Safety conducts on-site inspections of foreign food facilities before customs clearance as well as import inspection at the customs clearance stage. However, a data-based safety management plan for imported food is needed due to time, cost, and limited resources. In this study, we tried to increase the efficiency of the on-site inspection by preparing a machine learning prediction model that pre-selects the companies that are expected to fail before the on-site inspection. Basic information of 303,272 foreign food facilities and processing businesses collected in the Integrated Food Safety Information Network and 1,689 cases of on-site inspection information data collected from 2019 to April 2022 were collected. After preprocessing the data of foreign food facilities, only the data subject to on-site inspection were extracted using the foreign food facility_code. As a result, it consisted of a total of 1,689 data and 103 variables. For 103 variables, variables that were '0' were removed based on the Theil-U index, and after reducing by applying Multiple Correspondence Analysis, 49 characteristic variables were finally derived. We build eight different models and perform hyperparameter tuning through 5-fold cross validation. Then, the performance of the generated models are evaluated. The research purpose of selecting companies subject to on-site inspection is to maximize the recall, which is the probability of judging nonconforming companies as nonconforming. As a result of applying various algorithms of machine learning, the Random Forest model with the highest Recall_macro, AUROC, Average PR, F1-score, and Balanced Accuracy was evaluated as the best model. Finally, we apply Kernal SHAP (SHapley Additive exPlanations) to present the selection reason for nonconforming facilities of individual instances, and discuss applicability to the on-site inspection facility selection system. Based on the results of this study, it is expected that it will contribute to the efficient operation of limited resources such as manpower and budget by establishing an imported food management system through a data-based scientific risk management model.

Development Plan of Facility Importance, Risk, and Damage Estimation Inventory Construction for Assisting Disaster Response Decision-Making (재난대응 의사결정 지원을 위한 시설물 중요도·위험도·피해액 산정 인벤토리 구축 방안 연구)

  • CHOI, Soo-Young;GANG, Su-Myung;JO, Yun-Won;OH, Eun-Ho;PARK, Jae-Woo;KIM, Gil-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.1
    • /
    • pp.167-179
    • /
    • 2016
  • The safety of SOC facilities is constantly under threat by the globally increasing abnormal climate. Responding to disasters requires prompt decision-making such as suggesting evacuation paths. For doing so, spatio-temporal information with convergence of disaster information and SOC facility information must be utilized. Such information is being collected separately by the government or related organizations, but not collectively. The collective control of the separately collected disaster information and the generation of SOC facility safety and damage information are required for prompt disaster response. Also, as disaster information requires spatio-temporal convergence in its nature, the construction of an inventory that integrates related information and assists disaster response decision-making is required. A plan to construct a facility importance, risk, and damage estimation inventory for assisting prompt disaster response decision-making is suggested in this study. Through this study, the disaster and SOC facility-related data, which are being managed separately, can be collected and standardized. The integrated information required for the estimation of facility importance, risk, and damage can be provided. The suggested system is expected to be used as a decision-making tool for proactive disaster response.

Performance of the RI Exhaust Filter at Chosun University Cyclotron Facility and 18F Emission Reduction (조선대학교 사이클로트론 시설의 RI 배기필터 성능평가 및 18F 배출저감 연구)

  • Jeong, Cheol-Ki;Jang, Han;Lee, Goung-Jin
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • Recently, the number of PET cyclotrons has increased in Korea. A cyclotron mainly produces $^{18}F$, which is used for the production of [$^{18}F$]FDG, a cancer diagnostic radiopharmaceutical. For radiation protection, the discharge control standard under the Nuclear Safety Act limits the radioactive concentration of $^{18}F$ in the exhaust discharged from a nuclear power utilization facility to below $2,000Bq\;m^{-3}$. However, the radioactive concentration of $^{18}F$ discharged during [$^{18}F$]FDG production at the cyclotron facility at Chosun University is maintained at about $1,500Bq\;m^{-3}$ on average, which is 75% of the concentration limit of the discharge control standard, and temporarily exceeds the standard as per the real-time monitoring results. This study evaluated the performance of the exhaust filter unit of the cyclotron facility at Chosun University by assessing the concentration of $^{18}F$ in the exhaust, and an experiment was conducted on the discharge reduction, where $^{18}F$ is discharged without reacting with the FDG precursors during [$^{18}F$]FDG synthesis and is immediately captured by the [$^{18}F$]FDG automatic synthesis unit. Based on the performance evaluation results of the exhaust filter at the cyclotron facility of Chosun University, the measured capture efficiency before and after the filter was found to be 92%. Furthermore, the results of the discharge reduction experiment, where the exhaust $^{18}F$ was immediately captured by the [$^{18}F$]FDG synthesizer, showed a very satisfactory 94.3% reduction in the concentration of discharge compared to the existing discharge concentration.

A Study on the safety measures for the protection of hydrogen cooling system of generator (수소를 냉각매체로 하는 발전기 안전대책에 관한 연구)

  • Lee Choon-Ha;Yuk Hyun-Dai
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.4 s.25
    • /
    • pp.55-61
    • /
    • 2004
  • This paper provided a counter measures against the troubles and accidents that are likely to take place in the power plant using hydrogen gas as a coolant for the cooling system of the generator. Because of the extremely wide flammability limits of hydrogen in comparison to the other flammable gases, the safety measures against the hydrogen accidents is very important to ensure the normal operation of electric-power facility. This study's purpose was a presentation of standard model of safety management of hydrogen equipments in the coal firing power plant such as following items: 1) providing the technical prevention manual of the hydrogen explosions and hydrogen fires occurring in the cooling system of power generator; 2) the selection of explosion-proof equipments in terms of the risk level of operating environment; 3) the establishment of regulations and counter measures, such as the incorporation of gas leakage alarm device, for preventing the accidents from arising, 4) the establishment of safety management system to ensure the normal operation of the power plant.

  • PDF