Design considerations for teleoperation systems operating in gas-tight argon cells

  • Yu, Seungnam;Lee, Jongkwang;Park, Byungsuk;Cho, Ilje;Lee, Hyojik
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1717-1726
    • /
    • 2017
  • In the nuclear industry, mechanical engineers spend a significant portion of their time designing equipment such as manipulators, bogies, mechanical grippers, and so on. Some customized designs can be considered as standard mechanical equipment in this area, although it is not unusual to find that an existing design cannot simply be copied from one project to another. Varied performance requirements can dictate that redesign, often quite extensive redesign, is required. However, if something similar has been done before, engineers could use that as a starting point for the new project. In this regard, this study presents several guidelines inspired by previous design knowledge for similar development cases. Moreover, this study presents more detailed suggestions such as design guidelines for an argon-based hot cell atmosphere and design experience for a large-scale practical hot cell facility. Design considerations and case studies dealt with in this study are dedicated to teleoperation manipulators that are used at a large-scale argon cell facility for pyroprocess integrated inactive demonstration (PRIDE), at the Korea Atomic Energy Research Institute. In particular, for case studies to support the suggested recommendations, a fabricated telemanipulator system for PRIDE is introduced, and several kinds of experimental results associated with it are presented.

Approaching Knowledge, Attitudes, and Practices Model for Elderly with Dementia Who are Suspected to Have Hearing Impairment in Korea

  • You, Sunghwa;Han, Woojae
    • Journal of Audiology & Otology
    • /
    • v.24 no.1
    • /
    • pp.40-47
    • /
    • 2020
  • Because the psychophysical symptoms of hearing loss and dementia in the elderly are very similar, untrained healthcare professionals in dementia facilities can easily overlook a severity of hearing loss in their patients. The present study identifies their knowledge, attitudes, and practices (KAP) on hearing loss using a survey whether they may help hearing problem of the patients with dementia. A total of 29 health-care professionals responded to the KAP survey. Also, 2 family members participated. The results showed that most of the nurses and caregivers in elderly medical welfare facilities who worked with dementia patients did not have knowledge of their hearing loss. Even the facility managers did not know how to conduct hearing tests for their patients although they did recognize that some of their patients had a hearing loss. Eventually, actual practice was not possible at this moment by the professionals. However, our respondents did have a positive attitude toward screening for hearing loss and help their patients with dementia wear hearing aids if a clinical guideline was provided. We suggest to develop clear and precise clinical guidelines of the hearing screening test for the dementia patients due to the interrelationship between dementia and hearing loss. When these guidelines apply to elderly residents in a medical welfare facility, early diagnosis and treatment of their sensory loss will help alleviate their dementia as well.

Approaching Knowledge, Attitudes, and Practices Model for Elderly with Dementia Who are Suspected to Have Hearing Impairment in Korea

  • You, Sunghwa;Han, Woojae
    • Korean Journal of Audiology
    • /
    • v.24 no.1
    • /
    • pp.40-47
    • /
    • 2020
  • Because the psychophysical symptoms of hearing loss and dementia in the elderly are very similar, untrained healthcare professionals in dementia facilities can easily overlook a severity of hearing loss in their patients. The present study identifies their knowledge, attitudes, and practices (KAP) on hearing loss using a survey whether they may help hearing problem of the patients with dementia. A total of 29 health-care professionals responded to the KAP survey. Also, 2 family members participated. The results showed that most of the nurses and caregivers in elderly medical welfare facilities who worked with dementia patients did not have knowledge of their hearing loss. Even the facility managers did not know how to conduct hearing tests for their patients although they did recognize that some of their patients had a hearing loss. Eventually, actual practice was not possible at this moment by the professionals. However, our respondents did have a positive attitude toward screening for hearing loss and help their patients with dementia wear hearing aids if a clinical guideline was provided. We suggest to develop clear and precise clinical guidelines of the hearing screening test for the dementia patients due to the interrelationship between dementia and hearing loss. When these guidelines apply to elderly residents in a medical welfare facility, early diagnosis and treatment of their sensory loss will help alleviate their dementia as well.

A Study on Environmental Impact Assessment Guidelines for Marine Environmentsin Construction Projects of Offshore Waste Disposal Landfills (해상최종처리장 건설사업의 해양환경 환경영향평가 가이드라인 개발 연구)

  • Lee, Haemi;Son, Minho;Kang, Taesoon;Maeng, Junho
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.3
    • /
    • pp.312-331
    • /
    • 2019
  • An offshore waste disposal facility refers to a landfill site for final landfilling of stabilized inorganic solid waste such as land and marine waste incineration materials, and the aim of such a facility is to solve the problem of insufficient waste disposal space on land and create and develop environmentally friendly marine spaces. The purpose of this study is to prepare guidelines for the construction of offshore waste disposal facilities, which reflect the need and importance of paying sufficient heed to environmental considerations from the initial stage of the project, in order to investigate, predict, and assess how such guidelines will affect the marine environment in relation to the construction of offshore waste disposal facilities, with the goal of minimizing the impact on and damage to the environment. For the purpose of this research, guidelines focusing on the construction of offshore waste disposal facilities were derived through an analysis of domestic cases and similar foreign cases and an assessment of their level of compliance with existing EIA guidelines through the operation of a discussion forum. In order to review the EIA report on similar cases in Korea, 17 EIA documents (2005~2016) for dredged soil dumping areas and ash ponds of thermal power plants were analyzed to investigate the status of marine organisms, marine physics, marine water quality, and marine sediment and to understand what types of problems can occur and what improvement measures can be taken. The purpose of these guidelines were to minimize damage to the marine environment by promoting EIA protocols in accordance with scientific and systematic procedures, to reduce the consultation period related to projects, to resolve social conflicts, and to reduce economic costs.

Development of the Hospital Foodservice Facility Evaluation tools based on the General HACCP-based Sanitation Standards and Guidelines (병원급식에 일반위생관리기준과 HACCP 제도 적용을 위한 시설ㆍ설비 위생관리 점검도구 개발)

  • 이정숙;곽동경;강영재
    • Korean journal of food and cookery science
    • /
    • v.19 no.3
    • /
    • pp.339-353
    • /
    • 2003
  • The rapid increase in food borne illness outbreaks in Korea has been one of the major threats to the Nation's Health. Foodservice establishments have been identified as the major place for these outbreaks, mainly due to the lack of sanitary management and sanitary facility management practices. The purposes of the study were to develop hospital foodservice facility evaluation tools, based on the general HACCP-based standards and guidelines, for hospital food service establishments, to ensure the safety of these foodservices and to reduce the risk of food home illness. The scope of this study included: 1) an assessment of the current foodservice sanitation practices and managements for 6 general hospitals, with more than 400 beds, and 3 general hospitals, with less than 400 beds; 2) the development of foodservice establishments sanitation evaluation tools and sanitation standards, based on the HACCP system. The survey data showed varied results between the hospitals surveyed. Most of the hospital foodservice operations had many problems with ventilation and the plumbing. The total dimensional mean scores for the hospitals with more than 400 beds and less than 400 beds were 31.5 and 27.0, respectively. The highest dimension scores were for the water supply facility and lighting, with the lowest for insect and rodent control and toxic materials management. The levels of the mean scores were very low, especially for the general hospitals with less than 400 beds. These low mean scores may have arisen from critical problems within the hospital foodservice operations. The most needed facility management items for improvement were: storage shelf should be spaced 6 inches from the floor and walls, the use of three compartment sinks, utility sinks and cleaning facilities, with a floor drain for cleaning mops or liquid wastes, a ventilation hood designed to prevent dripping onto food, cooking facilities should be disassembled for washing and sanitizing, a separated hand washing sink and a sanitized food board for each area should be provided, all toxic material must have warning labels attached, and be stored in an area away from food preparation under padlock. The evaluation tool consisted of 14 dimensions, with 65 check-off items. The results of this study will provide basic facilities' guidelines to regulators, or foodservice industry personnel, wishing to build, or expend, and establish an efficient flow of food. As a result, food borne illnesses will be effectively prevented, and the Nation's health will be promoted for the development of their own sanitation standards, with a checklist for the safe production of foods.

A Survey Study on Space Use and Management at National Universities (국립대학 공간 활용과 관리에 관한 조사연구)

  • Lee, Hwa-Ryong;Cho, Chang-Hee;Ryu, Soo-Hoon;Kim, Tae-Hyung;Ryew, Choon-Geun;Seo, Boong-Kyo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.3
    • /
    • pp.3-10
    • /
    • 2014
  • A study of facility securement and space utilization at national universities in Korea was conducted in order to help develop an efficient model for space management at national universities going forward. For the study, 36 national universities were asked to submit answers to a questionnaire on usage of campus facilities in 2013. We then analyzed the results of space management for the 27 universities that participated in the questionnaire in each of the past three years (2011-2013). Lastly, we conducted an awareness test on the space utilization policies and space management for these universities. The results are as follows. First, the aggregate average score for space utilization over the past three years is 74.06. The annual average score increased year-over-year and then decreased; it was 69.44 in 2011, 80.68 in 2012, and 72.05 in 2013. A decline in the sense of responsibility of universities to effectively manage space appears to be a factor in the decrease. Second, with 53% of respondents in agreement, treatment of campus area as private space appears to be the biggest hurdle for efficient space management. As such, a plan to foster a more communal view of campus facility area is required. Third, resistance from constituents to existing guidelines for space allocation on campuses appears to be limited (78.1% of respondents answered the guidelines currently in place were average, satisfactory, or very satisfactory). We believe this result points to a mutual understanding forming amongst constituents regarding guidelines on space allocation on campus.results of satisfaction research: the users are generally satisfied with education and student.

A study on the Types of Urgent Isolation Ward (긴급치료격리병동의 평면유형)

  • Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.61-69
    • /
    • 2022
  • Purpose: In response to the rapid spread of COVID-19 in 2020, the government supported facilities and equipment through the 'Urgent Isolation Ward Expansion Project'. Design and remodeling of efficient negative pressure isolation facilities had to be done in a short period of time, and the performance gap between facilities was very large because the types of hospitals and wards of existing medical facilities were diverse. In order to secure the stability of isolation wards between medical facilities and reduce the facility gap, guidelines for planning isolation wards considering the diversity of each hospital should be appropriately presented. In consideration of these points, this study aims to provide basic data for future remodeling guidelines for each plan type of the negative pressure isolation ward first. Methods: We analyzed the plans before and after the change of 13 case hospitals that performed the urgent care bed expansion project for COVID-19 confirmed patients. Before the remodeling, the current status of the facility was analyzed according to the type of corridor, the location of the nursing station, and the location of the elevator. After remodeling, the flow of medical staff and patients, the flow of entry and exit of clean and contaminated items, and the space of negative pressure and non-negative pressure areas. Results: The ward type was divided into three types according to the corridor type and room arrangement: double loaded corridor type with two side wards, race track type with one side ward, and race track type with two side wards. Based on these three types, the standard floor plan type of the isolation ward was proposed in terms of the location of the elevator bank and Nurse station. Implications: When the existing general ward is converted into a negative pressure isolation ward, this study can be a basic data to present customized guidelines for each ward type.

Research on the Adequacy and Application of Safety Standards for Station Facility (역시설 안전기준의 적정성 및 적용성에 관한 연구)

  • Kim, Jin-Ho;Sin, Sung-Soon;Kim, Min-Hee
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.181-187
    • /
    • 2008
  • In 2004, railway safety law was established since intimidatory factors have increased for railway industry, such as high speed rail, urban transit extension, induction of new transportations. The projects for safety system establishment and guidelines are performed including the safety guidelines for station and platform. Therefore, in this study the safety rules are examined through investigation for stations

  • PDF

Differences between Design Guidelines and Use Behavior abort Play Facilities of Children\\` Playguound in Multi-Family Housing Site (공동주택단지 어린이놀이시설의 설계의도와 이용형태와의 차이점)

  • 김홍규;노정실;고원용
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.24 no.4
    • /
    • pp.39-58
    • /
    • 1997
  • This study aims to find out differences between designer's design guidelines and user's actual behavior about play facilities of children playground in multifamily housing site by using the method of Post-Occupancy Evaluation. Korea National Housing Cooperation developed the 18 play facilities and constructed them into children' playground of Bun-dong and Junggae-dong housing site in Seoul. The results are as follows: First, user's behaviors which differed from designer's guidelines were influenced by mechanical and technical problems rather than design. Second, users adjusted their brahvior to play facilities which have a little operational problems. Third. users tried to make dangrous activity instead of designer's guidelines based on the safety. It infers that users want to make creative activities from play facilities. Fourth. designers should have developed play facilities for infants and youth. Fifth. users liked to play more complicated play facilities rather than single facility.

  • PDF