• Title/Summary/Keyword: facility

Search Result 11,403, Processing Time 0.035 seconds

The Effect of Family Relationship on Facility Adaptation of Long-Term Care Facility Residents (노인장기요양기관 입소노인의 가족관계가 시설적응에 미치는 영향)

  • Kim, Yun-Jeong;Lee, Sang-Jin
    • Journal of Digital Convergence
    • /
    • v.16 no.4
    • /
    • pp.371-378
    • /
    • 2018
  • The purpose of this study is to investigate the effect of family relations on facility adaptation of the elderly. In January and February of 2018, a questionnaire survey was conducted on 5 ~ 6 elderly residents of each long-term care facility, and finally 353 data were used for analysis. The main results of the study were as follows: First, the adaptation level of the elderly was high. As for 'maladjustment of group behavior' and 'movement shock', the level of maladjustment is low as 2 points, and adaptation dimension such as 'accept of new residence' and 'making friend' is above the middle level. Second, the influence of family variables was more influential than the demographic characteristics of the elderly and the influence of the facility-related variables. Among them, the closeness with family is the most influential. Therefore, it is suggested that the elderly need active support and efforts to maintain the intimacy with the family from the entrance to the facility and the time after the entrance.

A Comparison of Medical Care Services by Type of Medical Care Facility -In cases of normal spontaneous vaginal delivery and acute appendicitis- (의료기관 종류별 진료내역 비교 -정상분만과 급성 충수염을 중심으로-)

  • Lee, Young-Doo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.18 no.1
    • /
    • pp.41-50
    • /
    • 1985
  • To find out the differences in medical practice according to the environment of patient care and managerial situation of the medical care institutions, normal spontaneous vaginal delivery and acute appendicitis were selected, which is suitable for comparison because of their high comparability. A total of 473 cases of normal spontaneous vaginal delivery and 408 cases of acute appendicitis was sampled from the claims to Korea Medical Insurance Cooperations during January to June 1984. Complicated cases were excluded from population and sampling was restricted from 40 to 60 percentile for total charges by the type of medical care facility in order to rule out the influence originating from case mix. Important items representing type and quantity of medical care service were compared by type of facility. Major findings are as follows : 1. University hospital shows the highest in charges per case and decrease in order of general hospital, and clinic. 2. In case of normal spontaneous vaginal delivery, average length of stay shows statistically significant difference by type of facility. 3. Charge amount for each service item affected by practice pattern shows statistically significant difference mostly by type of facility. It is suggested that medical practice pattern is different by type of facility for medical services. 4. Difference in total medical expenditure by type of facility is affected more with charges for materials, consumables and drugs than with fee for service activity. 5. In administering drugs to patients, hospital and clinic show higher injection rate than university and general hospital. 6. Clinical Laboratory tests were common in order of uninalysis, hemoglobin, hematocrit, white blood cell count, urine microscopic examination in cases of normal spontaneous vaginal delivery; white blood cell count, urinalysis, hemoglobin, hematocrit, urine microscopic examination, white blood cell differential count, in cases of acute appendicitis. 7. The result for Laboratory test and Radiologic study shows extreme difference by type of facility. Test rate is lowest in clinic and increase hospital, general hospital, and university hospital in order, both in type and frequency.

  • PDF

Development of the Scramjet engine Test Facility(SeTF) in Korea Aerospace Research Institute (한국항공우주연구원 스크램제트 엔진 시험설비의 개발)

  • Lee, Yang-Ji;Kang, Sang-Hun;Oh, Joong-Hwan;Yang, Soo-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.3
    • /
    • pp.69-78
    • /
    • 2010
  • Korea Aerospace Research Institute started on design and development of a hypersonic air-breathing engine test facility from 2000 and completed the test facility installation in July 2009. This facility, designated as Scramjet engine test facility(SeTF), is a blow-down type high enthalpy wind tunnel which has a pressurized air supply system, air heater system, free-jet test chamber, fuel supply system, facility control/measurement system and exhaust system. In this paper, details of the specifications, and configuration of the SeTF are described. For verifying characteristics of the SeTF, wind tunnel tests are now on progress and some of the data are also described.

Comparison of oral health status of school children utilizing school toothbrushing facility or school dental clinic (양치교실과 학교구강보건실 이용 학생들의 구강보건 실태 비교)

  • Kang, Hyun-Joo;Kwon, Hyun-Suk;Yu, Byeng-Chul
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.2
    • /
    • pp.173-179
    • /
    • 2014
  • Objectives : The purpose of this study is to provide the basic data for the development of oral health education program and to make schoolchildren practice the right oral health care behaviors. Methods : Data were collected from 259 elementary school students including 134 boys and 125 girls in Busan from November 26 to December 20, 2012. The groups were tooth brushing group and dental clinic group. All statistical analyses were analyzed by frequency analysis and chi-square test using SPSS 18.0 program. Results : School dental clinic group showed higher awareness level of fluoride and sealant effect of prevention(p=0.000). Toothbrushing facility group showed higher awareness level of brushing tooth(p=0.011). School dental clinic group showed higher awareness level of fluoride toothpaste(p=0.000). Both school dental clinic group and toothbrushing facility group showed higher awareness level of oral health education(p=0.001). School dental clinic group showed higher awareness level for tooth brushing method after education(p=0.000). Both school dental clinic group and toothbrushing facility group showed higher level of education. Conclusions : School dental clinic group showed higher level for oral health knowledge and toothbushing facility group showed high level for oral health behavior. Both School dental clinic group and toothbrushing facility group showed higher level of oral health education and tooth brushing method after education. Both school dental clinic group and toothbrushing facility group proved to promote oral health. Activation of school toothbrushing facility is very important to change the oral health workforce.

The Analysis of Present Condition and Utilization Planning of Closed School in Chungbuk Province (충북(忠北) 미활용(未活用) 폐교(閉校)의 실태(實態)와 활용방안(活用方案)에 대한 조사연구(調査硏究))

  • Jung, Jinju;Park, Seungryeol;Kim, Seunggeun;Choi, Hyoseung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.2 no.2
    • /
    • pp.23-34
    • /
    • 2000
  • Many primary schools that have been an important role in the community at the same time local important facility not only local area but also all area in Korea have shown a situation for closing and into grating a school because of a social and political measure. The education policy for man power training and closing policy for small scale school not more than 100 students can't role in the rural development policy, coming farming and fishing villages. The reasons for thinking some application paradigm and closing schools have been important role in the point of education and culture parts. Of course, the application paradigm for closing school facility will get accomplished for a mood of local residents and a point of cultural deference, not keeping up unconditionally for closing a school. For accomplishing versatile purposes, initiative role of the organs of local education is very important. The organs of local education have an application paradigm that closing schools are the facilities for local organs of education will plan some specific facility to be matched for local special quality and connection quality of surrounding facility and environment. Before an application paradigm of closing school, it is very important that a fundamental factor for negligence the facility will be solved. Eventually, the organs of education have a plan for technical study of this paradigm and consider keeping and mending of closing facility, rent the facility for payment or not they want, and confer money problem not an unconditional scale.

  • PDF

A Facility Design Model for 1300 Capacity School Foodservice with Adjacency and Bubble Diagrams (근접요구도와 버블다이어그램을 적용한 1300식 규모의 학교급식 시설 설계 모델)

  • Jang, Sun-hee;Chang, Hye-Ja
    • Korean Journal of Community Nutrition
    • /
    • v.16 no.1
    • /
    • pp.98-112
    • /
    • 2011
  • This study aimed to suggest a 1300 scale of a middle school foodservice facility floor plan which was compliant to the principle of HACCP, as well as ensuring food and work safety, and the flow of personnel and food materials. which consisted of 46 nutrition teachers and 6 experts, responded with a questionnaire on the relationship of functional area and space. Using their opinions, key principles for the design of the facility were single direction movement of food materials, customers and workers; minimization of the cross-contamination through the separation of functional space; and securement of customer-focused efficiency; staff-centered convenience and efficiency; and work and food safety. After the completion of an adjacency diagram, bubble diagram and program statement, the functional areas of a 1300 scale middle school food-service facility were allocated as follows: $9.9\;m^2$ for the receiving area, $56.1\;m^2$ for the pre-preparation area, $10.5\;m^2$ for the food storage area, $6.0\;m^2$ for the supplies storage area, $97.8\;m^2$ for the cooking area, $33.6\;m^2$ for the service area, $52.5\;m^2$ for dish washing area, cafeteria $410.5\;m^2$, $4.5\;m^2$ for the front room, for a total of $725.8\;m^2$. Expert groups have pointed to limitations within this model as there are no windows in the office for the influx of fresh outside air and a need for the straight line installation of steam-jacket and frying kettles on the sides of windows. This study can be useful as the guidelines for estimating the investment cost of the facility and placing the placement of functional areas and equipment in the renovation of the facility. It can be also useful data for a methodology of foodservice facility design.

Development of a Direct-Connected Supersonic Combustor Test Facility (직결형 초음속 연소기 시험 설비 개발)

  • Yang, Inyoung;Lee, Kyung-jae;Lee, Yang-ji;Kim, Hyung-Mo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.290-293
    • /
    • 2017
  • A direct-connected, continuous type combustion test facility was developed to test a supersonic combustor model used in scramjet engines. The facility requirements were determined by assuming the flight speed of Mach 5, yielding the combustor inlet flow speed of Mach 2. Also the cross-section of the supersonic combustor under test was assumed as $32mm{\times}70mm$. As a result, the facility was designed to have the flow total pressure of 548 kPaA, total temperature of 1,320 K, and flow rate of 0.776 kg/s. The facility consists of a turbo type air compressor, electric air heater, vitiation air heater and a two dimensional facility nozzle to accelerate the flow to Mach 2. Also, an oxygen supply system was added to compensate the vitiation. The exhaust de-pressurization system is not added. Designed pressure, temperature, and flow rate were verified through the test operation of the facility.

  • PDF

A Study on the Database Construction and the Management System Development of Water-Facility Using GSIS (GSIS를 이용한 상수도시설물의 데이터베이스 구축 및 관리시스템 개발에 관한 연구)

  • Kim, Young-Kon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.10 no.1 s.19
    • /
    • pp.109-123
    • /
    • 2002
  • The purpose of this study construct water-facility Database and to develop its management system using GSIS. We used route system and event table that are data model in GSIS for the construction of water valves on water facility pipe. A water-facility management system using GSIS was developed and was actually applied for the city of Yosu and compared with conventional water-facility management systems in terms of workability, information searching cost, and database management efficiency. The system has also been compared with those of two other local governments in terms of functions, process time, and conveniences. The generalization of the work model for water-facility system was also attempted based on the data collected from three local governments and it was revised by the work model of the wide area water-facility system. The generalized work model in this study was compared with other two local governments' work models. The generalized work model will enable local governments to develop more efficient and economical water-facility management system by GSIS in future.

  • PDF

A Study on Proposing of Evaluation Factors for Educational Adequacy of Elementary School Facility (초등학교시설의 교육 지원성 평가요소 제안에 대한 연구)

  • Lee, Hyun-Joo
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.3
    • /
    • pp.15-22
    • /
    • 2008
  • The purpose of this study is to propose evaluation factors for elementary school facility in terms of educational adequacy. The focal point of this study is to clarify the proper measure of educational facility evaluation in the light of specific characteristics of facility. In order to improve the level of educational adequacy, more information is needed regarding school facility design and various factors which affect to the design. This is important works because such information is essential in implementing facility design to meet the needs of the new educational policy. To get the goal, first, it is attempted to analyse the meaning of design information which deeply affect on the school facility design. The design information is classified into three main aspects, such as human aspect, social aspect and physical aspect. The design information regarding the physical space verses human psychology and behavior belongs to category of human aspect. Pedagogic ideology which varies depend upon the time and regions is classified into the category of social aspect. The Physical aspect means efficient equipment performance of space to support educational activities effectively. Secondly, as for the educational adequacy evaluation concern, it is attempted to select more items which usually has been neglected by the existing evaluation criteria which mainly emphasized functional performances only. With the premise of the above, in this paper, it is attempted to propose proper evaluation factors in terms of educational adequacy for school facilities. As the research methods, researching of literature on this subject, field trip, interview, site analysis, and survey is used.

A Study on the direction for Facility Improvement of Nationally Designated Negative Pressure Isolation Ward through Post Occupancy Evaluation (거주 후 평가를 통한 국가지정 입원치료병상 시설 개선 방향 도출에 관한 연구)

  • Jeong, Dawoon;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.3
    • /
    • pp.39-49
    • /
    • 2021
  • Purpose: The negative pressure isolation ward is a key facility in preparedness and response to infectious diseases. For the sustainable operation of the facility, appropriate facility improvement is required. The experience of medical staff responding to infectious diseases in the COVID-19 pandemic provides effective informations for facility planning. Methods: The post occupancy evaluation (POE) was conducted by interviewing medical staff who is working on Nationally designated negative pressure isolation ward in general hospital. Floor plan analysis was conducted before field surveys for identifying facility characteristic and spatial composition. After that, field surveys were conducted at 3 hospitals, and interviews and fieldwork were conducted together. Results: It is necessary to increase the standard size of ward area from 15m2 to 20m2. The size of the doffing room has to be planned for accommodation of two or more people. Equipment storage, clean storage and waste storage also should be properly planned. There were almost no problems with the circulation in the ward. There was not enough space for medical staff. Implications: For a sustainable and safe negative pressure isolation ward planning, it is necessary to exploit learning from the medical staffs who have many experiences of coping with infectious diseases.