• Title/Summary/Keyword: face width

Search Result 251, Processing Time 0.041 seconds

A study of post-operative changes in facial height and width of mandibular prognathic patients (하악전돌증 환자의 수술후 안모길이 및 폭경의 변화에 관한 연구)

  • Kim, Eun-Joo;Moon, Cheol-Hyun
    • The korean journal of orthodontics
    • /
    • v.30 no.3 s.80
    • /
    • pp.367-375
    • /
    • 2000
  • If a mandibular prognathic patient has an extremely unnatural anteroposterior and vertical maxilla or keen esthetical perception for facial profile, orthognathic surgery must be performed along with orthodontic treatment, which alone cannot provide satisfactory results in this case. Esthetical improvement becomes an important factor in the satisfaction level of the patient's treatment result, but an attempt to objectively measure beauty holds many problems. Therefore, in the end, the patient submits the final esthetical evaluation based on his/her subjective viewpoint. Because Korean people have a tendency to prefer the facial appeareance of westerners, they favor an oval shaped face over the traditional round face. This research was conducted in response to the complaints raised by patients who claim that their face had become more round from widening of facial width after the orthognathic surgery for manidibular prognathism than before the surgery. The following results were obtained on the changes in facial appearance and patient satisfaction level by analyzing the skull P-A analysis of total of 14 patients (8 male and 6 female) who underwent orthognathic surgery primarily chief complaint for manidibular prognathism and from their responses on questionnaires. These results are to be used in the research on the pre- and post- operative changes in facial height and width from orthognatic surgery. 1. Three ($21.4\%$) of 14 patients said that their face had widened. 2. The A group showed no change in mandibular width but B group showed a 0.7mm reduction. The facial width increased by 0.45mm and 0.66mm in groups A and B, respectively, after the orthognathic surgery 3. After the surgery the facial length changed by an 0.52mm increase in upper facial height , 1.19mm reduction in lower facial height, and 0.7mm reduction in mandibular height in group A. In group B group, there was a 0.67mm reduction in upper facial height, 3.66mm reduction in lower facial height, and 5mm reduction in mandibular height. 4. In reference to facial width, the facial height showed $1.5\%$ reduction in group A and $3.6\%$ reduction in group B after the surgery. 5. In reference mandibular height-to-facial width ratio, there was a $1.3\%$ reduction in group A, and $4.4\%$ reduction in group B after the surgery. 6. In reference to the mandibular height-to-width ratio, there was a $1.3\%$ reduction in group A and $4.3\%$ reduction in group B after the surgery. 7. Although the change in the facial width due to surgery can be ignored, sufficient explanation should be Provided to the patient before surgery on the fact that the face can appear to be relatively wide because of the reduced facial length as result of the surgery.

  • PDF

The Comparison of Long-term Effect of Botox® injection on Lower Face Contouring after Single injection and Long-term Repeated injections by Standardized Photograph Analysis (Botox®를 이용한 하안면윤곽술에서 단일시술과 장기간 반복시술의 효과 지속 기간의 비교: 표준화된 사진 계측을 이용한 분석)

  • Park, Mee Young;Ahn, Ki Young
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.654-659
    • /
    • 2009
  • Purpose: A botulinum toxin type A (BoNT - A) injection has been used as a noninvasive management for lower face contouring since 2000. The aim of this study was to compare reduction rate of lower face width for a longtime according to repeated Botox$^{(R)}$ injections on masseter muscles for lower face contouring procedure. Methods: Forty - five patients were analyzed for single session of Botox$^{(R)}$ injection and 13 patients were evaluated for repeated Botox$^{(R)}$ injections for over two years. Single injection group was tracked regular intervals at 1, 3, 6, 10, 12 months after injection, and repeated injection group was measured at every injection time. Twenty - five to thirty units of Botox$^{(R)}$ was injected into each masseteric muscle at five to six points at the prominent portions of the mandibular angle. Standardized frontal view of digital photographs were analyzed by Adobe Photoshop$^{(R)}$ (version CS3) to measure an reduction rate of lower face width. Results: Reduction rate was 3.7%, 6.9%, 6.2%, 4%, 4% at 1, 3, 6, 10, 12 months post injection each other in single injection group. However, more than 8% reduction rate was found in repeated injection group persistently for more than two years. Conclusion: This study shows that effective duration of Botox$^{(R)}$ injection for lower face contouring is expected to continue over one year clinically. Moreover, repeated injections maintained lower reduction rate consistently for a long time. Therefore, repeated injections on masseter muscles at regular intervals are most effective procedure for lower face contouring.

Back-Face Strain Compliance Calibration for the Four-Point Bend Specimen

  • Huh, Yong-Hak;Song, Ji-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.314-319
    • /
    • 2000
  • Back-face strain compliance (BFS compliance) for the four-point bend specimen has been calibrated for various crack length ratios. Finite element technique was employed to simulate four-point loading and calculate back-face strain of the bend specimen. The numerically determined strain variation along the back face indicates that the sensitivity to gage placement increases with crack length and back-face strain at the gage length less than O.2W, where W is the width of the bend specimen, can be measured within 5% deviation of the maximum BFS. Non-dimensional back-face strain compliance, -E'BCW, was calibrated with FE analysis and experiment. The experimentally determined compliance indicates good agreement with the numerical compliance and can be expressed as a function of crack length ratio.

  • PDF

A study on Face Recognition Technology in the Dynamic Link Architecture (동적 링크 구조상에서의 얼굴 인식 기술에 관한 연구)

  • Lee, Seoung-Cheol;Kim, Hyun-Sool;Kim, Ji-Hun;Park, Sang-Hui
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3236-3238
    • /
    • 1999
  • This paper proposes a new face recognition technique in the dynamic link architecture which shows robustness against size variation and distortion. The face recognition technique in the dynamic link architecture so far was not appropriate for the recognition of various size of faces because of the fixed size of the graph and the fixed value of a of the Gabor filter not considering the size of the face. The proposed face recognition algorithm can represent the input facial image by a suitable size of labeled graph, and it can also adjust the dilation width and the height of the vibrating amplitude of the Gabor filter, thus face recognition in the dynamic link architecture is even applicable regardless of the size of the face.

  • PDF

Bending analysis of a micro sandwich skew plate using extended Kantorovich method based on Eshelby-Mori-Tanaka approach

  • Rajabi, Javad;Mohammadimehr, Mehdi
    • Computers and Concrete
    • /
    • v.23 no.5
    • /
    • pp.361-376
    • /
    • 2019
  • In this research, bending analysis of a micro sandwich skew plate with isotropic core and piezoelectric composite face sheets reinforced by carbon nanotube on the elastic foundations are studied. The classical plate theory (CPT) are used to model micro sandwich skew plate and to apply size dependent effects based on modified strain gradient theory. Eshelby-Mori-Tanaka approach is considered for the effective mechanical properties of the nanocomposite face sheets. The governing equations of equilibrium are derived using minimum principle of total potential energy and then solved by extended Kantorovich method (EKM). The effects of width to thickness ratio and length to width of the sandwich plate, core-to-face sheet thickness ratio, the material length scale parameters, volume fraction of CNT, the angle of skew plate, different boundary conditions and types of cores on the deflection of micro sandwich skew plate are investigated. One of the most important results is the reduction of the deflection by increasing the angle of the micro sandwich skew plate and decreasing the deflection by decreasing the thickness of the structural core. The results of this research can be used in modern construction in the form of reinforced slabs or stiffened plates and also used in construction of bridges, the wing of airplane.

Anthropometric Studies on the Analysis of Women's Beautiful Face (20대 여성의 미인형 분석을 위한 계측학적 연구)

  • Park, Oak-Reon;Song, Mi-Young
    • Korean Journal of Human Ecology
    • /
    • v.14 no.5
    • /
    • pp.813-820
    • /
    • 2005
  • The beauty itself cannot be changed by the time, but the concept of the beauty can be influence by the time and cultural background. The purpose of this study is to analyze the beautiful faces or ugly faces among the young women and to provide useful guideline to make up for the modem concept of beauty. The facial photographs of 180 adlut women(aged between 20 and 29) in Pusan and Ulsan area were sampled to be measured and classified as the beautiful or ordinary or ugly faces. Data were analyzed by Frequencies, Mean, Duncan's Multiple Range Test. The major results were as followings; the Beautiful face has a relatively small face with a broad forehead and a small lower face. It also has a wide palpebral fissure, narrow intercanthal distance, a narrow nose and a big mouth. Physiognomic face length was 182.38mm, the upper face length was 59.82mm, the middle face length 60.82mm, the lower face length 61.76mm, and the index of face length to face breadth was 1.35. And also the faces within the figures are considered as the beautiful or ordinary or ugly faces from those measurements like face length/bizygion breadth, intercanthal distance, mouth width, upper vermilion height, lower vermilion height.

  • PDF

Face Recognition and Notification System for Visually Impaired People (시각장애인을 위한 얼굴 인식 및 알림 시스템)

  • Jin, Yongsik;Lee, Minho
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.12 no.1
    • /
    • pp.35-41
    • /
    • 2017
  • We propose a face recognition and notification system that can transform visual face information into tactile signals in order to help visually impaired people. The proposed system consists of a glasses type camera, a mobile computer and an electronic cane. The glasses type camera captures the frontal view of the user, and sends this image to mobile computer. The mobile computer starts to search for human's face in the image when obstacles are detected by ultrasonic sensors. In a case that human's face is detected, the mobile computer identifies detected face. At this time, Adaboost and compressive sensing are used as a detector and a classifier, respectively. After the identification procedures of the detected face, the identified face information is sent to controller attached to a cane using a Bluetooth communication. The controller generates motor control signals using Pulse Width Modulation (PWM) according to the recognized face labels. The vibration motor generates vibration patterns to inform the visually impaired person of the face recognition result. The experimental results of face recognition and notification system show that proposed system is helpful for visually impaired people by providing person identification results in front of him/her.

Voice Coding Using Only the Features of the Face Image

  • Cho, Youn-Soo;Jang, Jong-Whan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.3E
    • /
    • pp.26-29
    • /
    • 1999
  • In this paper, we propose a new voice coding using only the features of the face image such as mouth height(H), width(W), rate(R=W/H), area(S), and ellipse's feature(P). It provides high security and is not affected by acoustic noise because we use only the features of face image for speech. In the proposed algorithm, the mean recognition rate for the vowels approximately rises between 70% and 96% after many tests.

  • PDF

Skin Color Based Facial Features Extraction

  • Alom, Md. Zahangir;Lee, Hyo Jong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.351-354
    • /
    • 2011
  • This paper discusses on facial features extraction based on proposed skin color model. Different parts of face from input image are segmented based on skin color model. Moreover, this paper also discusses on concept to detect the eye and mouth position on face. A height and width ratio (${\delta}=1.1618$) based technique is also proposed to accurate detection of face region from the segmented image. Finally, we have cropped the desired part of the face. This exactly exacted face part is useful for face recognition and detection, facial feature analysis and expression analysis. Experimental results of propose method shows that the proposed method is robust and accurate.

The Study of Standard Face Shape Analysis of Adult Women for Make-Up (메이크업을 위한 우리나라 성인 여성의 표준 얼굴 형태에 관한 연구)

  • Kim, Jeong-Hee
    • Journal of the Korean Society of Costume
    • /
    • v.57 no.5 s.114
    • /
    • pp.151-165
    • /
    • 2007
  • Appearance matters in society today. Women want to feel good and look their best. They do make-up, wear garment and accessory for their good looking. Doing make-up, we have to know how we are look and to consider face shape. But it is difficult to recognize face shape. Because there is no standard face shape of adult women of quantitative analysis. The purpose of this study was to offer standard face shape of adult women in Korea. Furthermore, the study was to determine and differentiate face shape of each age group to set the basic data for the Korean beauty industry. In this study, photographs of 600 Korean women, age between $20{\sim}50's$, were indirectly measured in Venus face2D program. The measurements were analyzed by statistical methods. As a result of basic statistical data analysis, the average lengths of face were 196mm, lengths of forehead-hairline between eyebrows were 62mm, lengths of eyebrow between noses were 68mm, length of nose between chin were 66mm, and width of face were 150mm. By comparing to each age group's face using ANOVA, the statistically noticeable differences were found in measurements.